If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-111-20315 | | Well ID: 37-111-20315 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 39.743522, -79.357636 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 11 | + | | Spud Date: 2012-11-28 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2012-07-23 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2014-07-26 | ||
+ | | 2014-07-30 | ||
+ | | style="text-align: right;" | 8853 | ||
+ | | style="text-align: right;" | 5,235,490.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="18"| 1 | ||
+ | | rowspan="4"| A264 | ||
+ | | rowspan="4"| Schlumberger | ||
+ | | rowspan="4"| Iron Control | ||
+ | | Aliphatic acids | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00002774 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 0.00003699 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Aliphatic alcohols, ethoxylayed #1 | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00002774 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Prop-2-yn-1-ol | ||
+ | | 107-19-7 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00000925 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Base Fluid | ||
+ | | rowspan="1"| Chevron | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | Water (Including Mix Water Supplied by Client) | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 87.9461 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| B466 | ||
+ | | rowspan="3"| Schlumberger | ||
+ | | rowspan="3"| Friction Reducer | ||
+ | | Ammonium Acetate | ||
+ | | 631-61-8 | ||
+ | | style="text-align: right;" | 6 | ||
+ | | style="text-align: right;" | 0.00015119 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Alcohol Ethoxylates | ||
+ | | Propietary | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00012599 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Distillates (petroleum), hydrotreated light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00075595 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| L058 | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Iron Stabilizer | ||
+ | | Sodium erythorbate | ||
+ | | 6381-77-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00045334 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Proppant | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Proppant | ||
+ | | Crystalline Silica | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 11.8853 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| J580 | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Gelling Agent | ||
+ | | Carboydrate polymer | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.033099 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 7.5% Acid | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Perf Cleanup | ||
+ | | Hydrocloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 8 | ||
+ | | style="text-align: right;" | 0.00761599 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| EC6116A | ||
+ | | rowspan="3"| Nalco | ||
+ | | rowspan="3"| Biocide | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.0001266 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 2,2-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00075959 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Polyethylene Glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00151918 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| EC6673W | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Iron Control | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0036866 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| J134 | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Gel Breaker | ||
+ | | Hemicellulase Enzyme | ||
+ | | 9012-54-8 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00156226 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| EC6486A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00079405 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 147: | Line 336: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | + | | 2013-S01 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2013- | ||
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 492.74 Tons | | style="text-align: right;" | 492.74 Tons | ||
Line 207: | Line 342: | ||
| 100419 | | 100419 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 1,005.00 Bbl | | style="text-align: right;" | 1,005.00 Bbl | ||
Line 213: | Line 348: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 848.00 Bbl | | style="text-align: right;" | 848.00 Bbl | ||
Line 219: | Line 354: | ||
| | | | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 472.78 Tons | | style="text-align: right;" | 472.78 Tons | ||
Line 225: | Line 360: | ||
| 100172 | | 100172 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 11.67 Bbl | | style="text-align: right;" | 11.67 Bbl | ||
Line 231: | Line 366: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 2,727.67 Bbl | | style="text-align: right;" | 2,727.67 Bbl | ||
Line 237: | Line 372: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 28.33 Bbl | | style="text-align: right;" | 28.33 Bbl | ||
Line 243: | Line 378: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 58.23 Tons | | style="text-align: right;" | 58.23 Tons | ||
Line 249: | Line 384: | ||
| 76-00-08 | | 76-00-08 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 70.83 Bbl | | style="text-align: right;" | 70.83 Bbl | ||
Line 255: | Line 390: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 4,304.17 Bbl | | style="text-align: right;" | 4,304.17 Bbl | ||
Line 261: | Line 396: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 13.33 Bbl | | style="text-align: right;" | 13.33 Bbl | ||
Line 267: | Line 402: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 23.48 Tons | | style="text-align: right;" | 23.48 Tons | ||
Line 273: | Line 408: | ||
| 100592 | | 100592 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 0.11 Tons | | style="text-align: right;" | 0.11 Tons | ||
Line 279: | Line 414: | ||
| MID0209062814 | | MID0209062814 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 16.67 Bbl | | style="text-align: right;" | 16.67 Bbl | ||
Line 285: | Line 420: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 5,986.17 Bbl | | style="text-align: right;" | 5,986.17 Bbl | ||
Line 291: | Line 426: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 13.33 Bbl | | style="text-align: right;" | 13.33 Bbl | ||
Line 297: | Line 432: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 4,930.67 Bbl | | style="text-align: right;" | 4,930.67 Bbl | ||
Line 303: | Line 438: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 106.00 Bbl | | style="text-align: right;" | 106.00 Bbl | ||
Line 309: | Line 444: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 40.00 Bbl | | style="text-align: right;" | 40.00 Bbl | ||
Line 315: | Line 450: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 49.00 Bbl | | style="text-align: right;" | 49.00 Bbl | ||
Line 321: | Line 456: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 133.00 Bbl | | style="text-align: right;" | 133.00 Bbl | ||
Line 327: | Line 462: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 65.00 Bbl | | style="text-align: right;" | 65.00 Bbl | ||
Line 333: | Line 468: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 74.00 Bbl | | style="text-align: right;" | 74.00 Bbl | ||
Line 339: | Line 474: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M10 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 56.00 Bbl | | style="text-align: right;" | 56.00 Bbl | ||
Line 351: | Line 480: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 129.00 Bbl | | style="text-align: right;" | 129.00 Bbl | ||
Line 357: | Line 486: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 181.00 Bbl | | style="text-align: right;" | 181.00 Bbl | ||
Line 363: | Line 492: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2016-S01 |
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 1,521.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2017-M01 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 219.00 Bbl | | style="text-align: right;" | 219.00 Bbl | ||
Line 369: | Line 504: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 199.00 Bbl | | style="text-align: right;" | 199.00 Bbl | ||
Line 375: | Line 510: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 95.00 Bbl | | style="text-align: right;" | 95.00 Bbl | ||
Line 381: | Line 516: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 148.00 Bbl | | style="text-align: right;" | 148.00 Bbl | ||
Line 387: | Line 522: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 176.00 Bbl | | style="text-align: right;" | 176.00 Bbl | ||
Line 393: | Line 528: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 14.00 Bbl | | style="text-align: right;" | 14.00 Bbl | ||
Line 399: | Line 534: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 108.00 Bbl | | style="text-align: right;" | 108.00 Bbl | ||
Line 405: | Line 540: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 177.00 Bbl | | style="text-align: right;" | 177.00 Bbl | ||
Line 411: | Line 546: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 95.00 Bbl | | style="text-align: right;" | 95.00 Bbl | ||
Line 417: | Line 552: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 68.00 Bbl | | style="text-align: right;" | 68.00 Bbl | ||
Line 423: | Line 558: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 109.00 Bbl | | style="text-align: right;" | 109.00 Bbl | ||
Line 429: | Line 564: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 14.00 Bbl | | style="text-align: right;" | 14.00 Bbl | ||
Line 435: | Line 570: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 106.00 Bbl | | style="text-align: right;" | 106.00 Bbl | ||
Line 441: | Line 576: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 17.00 Bbl | | style="text-align: right;" | 17.00 Bbl | ||
Line 447: | Line 582: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 69.00 Bbl | | style="text-align: right;" | 69.00 Bbl | ||
Line 453: | Line 588: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 10.00 Bbl | | style="text-align: right;" | 10.00 Bbl | ||
Line 459: | Line 594: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 129.00 Bbl | | style="text-align: right;" | 129.00 Bbl | ||
Line 465: | Line 600: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 39.00 Bbl | | style="text-align: right;" | 39.00 Bbl | ||
Line 471: | Line 606: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 30.00 Bbl | | style="text-align: right;" | 30.00 Bbl | ||
Line 477: | Line 612: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 149.00 Bbl | | style="text-align: right;" | 149.00 Bbl | ||
Line 483: | Line 618: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 79.00 Bbl | | style="text-align: right;" | 79.00 Bbl | ||
Line 489: | Line 624: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 60.00 Bbl | | style="text-align: right;" | 60.00 Bbl | ||
Line 495: | Line 630: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 102.00 Bbl | | style="text-align: right;" | 102.00 Bbl | ||
Line 501: | Line 636: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 34.00 Bbl | | style="text-align: right;" | 34.00 Bbl | ||
Line 507: | Line 642: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 17.00 Bbl | | style="text-align: right;" | 17.00 Bbl | ||
Line 513: | Line 648: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 128.00 Bbl | | style="text-align: right;" | 128.00 Bbl | ||
Line 519: | Line 654: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 18.00 Bbl | | style="text-align: right;" | 18.00 Bbl | ||
Line 525: | Line 660: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 186.00 Bbl | | style="text-align: right;" | 186.00 Bbl | ||
Line 531: | Line 666: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 116.00 Bbl | | style="text-align: right;" | 116.00 Bbl | ||
Line 537: | Line 672: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 62.00 Bbl | | style="text-align: right;" | 62.00 Bbl | ||
Line 543: | Line 678: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 125.00 Bbl | | style="text-align: right;" | 125.00 Bbl | ||
Line 549: | Line 684: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 36.00 Bbl | | style="text-align: right;" | 36.00 Bbl | ||
Line 555: | Line 690: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 36.00 Bbl | | style="text-align: right;" | 36.00 Bbl | ||
Line 561: | Line 696: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 110.00 Bbl | | style="text-align: right;" | 110.00 Bbl | ||
Line 567: | Line 702: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 6.00 Bbl | | style="text-align: right;" | 6.00 Bbl | ||
Line 573: | Line 708: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 130.00 Bbl | | style="text-align: right;" | 130.00 Bbl | ||
Line 579: | Line 714: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 121.00 Bbl | | style="text-align: right;" | 121.00 Bbl | ||
Line 585: | Line 720: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 102.00 Bbl | | style="text-align: right;" | 102.00 Bbl | ||
Line 610: | Line 745: | ||
| 2120892 | | 2120892 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2012-11-30 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 617: | Line 752: | ||
| 2121599 | | 2121599 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2012-11-28 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 624: | Line 759: | ||
| 2123110 | | 2123110 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2012-12-12 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 631: | Line 766: | ||
| 2128474 | | 2128474 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2012-12-17 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 638: | Line 773: | ||
| 2128635 | | 2128635 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2013-01-08 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 645: | Line 780: | ||
| 2128642 | | 2128642 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2013-01-08 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 652: | Line 787: | ||
| 2130321 | | 2130321 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2013-01-14 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 659: | Line 794: | ||
| 2143502 | | 2143502 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2013-02-11 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 666: | Line 801: | ||
| 2143519 | | 2143519 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2013-02-22 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 673: | Line 808: | ||
| 2144644 | | 2144644 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2013-02-25 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 680: | Line 815: | ||
| 2151592 | | 2151592 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2013-03-13 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 687: | Line 822: | ||
| 2173650 | | 2173650 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2013-06-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 694: | Line 829: | ||
| 2181334 | | 2181334 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2013-05-22 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 701: | Line 836: | ||
| 2228157 | | 2228157 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2013-11-26 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 708: | Line 843: | ||
| 2228274 | | 2228274 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2013-10-31 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 715: | Line 850: | ||
| 2228740 | | 2228740 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2013-10-09 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 722: | Line 857: | ||
| 2229869 | | 2229869 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2013-09-26 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 729: | Line 864: | ||
| 2235866 | | 2235866 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2014-01-13 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 736: | Line 871: | ||
| 2244514 | | 2244514 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2014-02-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 743: | Line 878: | ||
| 2251005 | | 2251005 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2014-03-05 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 750: | Line 885: | ||
| 2252451 | | 2252451 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2014-03-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 757: | Line 892: | ||
| 2298122 | | 2298122 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2014-08-20 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 764: | Line 899: | ||
| 2311288 | | 2311288 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2014-10-08 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 771: | Line 906: | ||
| 2408937 | | 2408937 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2015-09-18 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 908: | Line 1,043: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-111-20315 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.743522,"lon":-79.357636,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Somerset | |
Municipality: Addison Township | |
Operator Name: LPR ENERGY LLC | |
Well Pad ID: 149069 | |
Farm/Lease Name: PMG ALLEN UNIT 6H | |
License Status: Active | |
Spud Date: 2012-11-28 | |
Permit Date: 2012-07-23 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.743522 | |
Longitude: -79.357636 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-07-26 | 2014-07-30 | 8853 | 5,235,490.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | A264 | Schlumberger | Iron Control | Aliphatic acids | Proprietary | 30 | 0.00002774 | 0 |
Methanol | 67-56-1 | 40 | 0.00003699 | 0 | ||||
Aliphatic alcohols, ethoxylayed #1 | Proprietary | 30 | 0.00002774 | 0 | ||||
Prop-2-yn-1-ol | 107-19-7 | 10 | 0.00000925 | 0 | ||||
Base Fluid | Chevron | Carrier/Base Fluid | Water (Including Mix Water Supplied by Client) | 7732-18-5 | 100 | 87.9461 | 0 | |
B466 | Schlumberger | Friction Reducer | Ammonium Acetate | 631-61-8 | 6 | 0.00015119 | 0 | |
Alcohol Ethoxylates | Propietary | 5 | 0.00012599 | 0 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 30 | 0.00075595 | 0 | ||||
L058 | Schlumberger | Iron Stabilizer | Sodium erythorbate | 6381-77-7 | 100 | 0.00045334 | 0 | |
Proppant | Schlumberger | Proppant | Crystalline Silica | 14808-60-7 | 100 | 11.8853 | 0 | |
J580 | Schlumberger | Gelling Agent | Carboydrate polymer | Proprietary | 100 | 0.033099 | 0 | |
7.5% Acid | Schlumberger | Perf Cleanup | Hydrocloric Acid | 7647-01-0 | 8 | 0.00761599 | 0 | |
EC6116A | Nalco | Biocide | Dibromoacetonitrile | 3252-43-5 | 5 | 0.0001266 | 0 | |
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00075959 | 0 | ||||
Polyethylene Glycol | 25322-68-3 | 60 | 0.00151918 | 0 | ||||
EC6673W | Nalco | Iron Control | Ethylene Glycol | 107-21-1 | 30 | 0.0036866 | 0 | |
J134 | Schlumberger | Gel Breaker | Hemicellulase Enzyme | 9012-54-8 | 100 | 0.00156226 | 0 | |
EC6486A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00079405 | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 320,490.00 | 324 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 192,448.86 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | LPR ENERGY LLC | 159,486.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | LPR ENERGY LLC | 172,724.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | LPR ENERGY LLC | 54,967.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2013-S01 | Drill Cuttings (in Tons) | 492.74 Tons | LANDFILL | 100419 |
2013-S01 | Drilling Fluid Waste (in Barrels) | 1,005.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013-S01 | Drilling Fluid Waste (in Barrels) | 848.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Drill Cuttings (in Tons) | 472.78 Tons | LANDFILL | 100172 |
2014-S01 | Produced Fluid (in Barrels) | 11.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Fracing Fluid Waste (in Barrels) | 2,727.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 28.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Fracturing Fluid Waste (in Tons) | 58.23 Tons | LANDFILL | 76-00-08 |
2014-S02 | Produced Fluid (in Barrels) | 70.83 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Fracing Fluid Waste (in Barrels) | 4,304.17 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-S01 | Fracing Fluid Waste (in Barrels) | 13.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Fracturing Fluid Waste (in Tons) | 23.48 Tons | LANDFILL | 100592 |
2015-S01 | Fracturing Fluid Waste (in Tons) | 0.11 Tons | STORAGE PENDING DISPOSAL OR REUSE | MID0209062814 |
2015-S01 | Produced Fluid (in Barrels) | 16.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-S01 | Produced Fluid (in Barrels) | 5,986.17 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 13.33 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-S02 | Produced Fluid (in Barrels) | 4,930.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M04 | Produced Fluid (in Barrels) RWC 802 | 106.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M05 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M06 | Produced Fluid (in Barrels) RWC 802 | 49.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M07 | Produced Fluid (in Barrels) RWC 802 | 133.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M08 | Produced Fluid (in Barrels) RWC 802 | 65.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M09 | Produced Fluid (in Barrels) RWC 802 | 74.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2016-M10 | Produced Fluid (in Barrels) RWC 802 | 56.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M11 | Produced Fluid (in Barrels) RWC 802 | 129.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M12 | Produced Fluid (in Barrels) RWC 802 | 181.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 1,521.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 219.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 199.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 95.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 148.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 176.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 14.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 108.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 177.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 95.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 68.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 109.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 14.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 106.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 17.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 69.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 10.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 129.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 39.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 30.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 149.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 79.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 60.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 102.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 34.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 17.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 128.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 18.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 186.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 116.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 62.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 125.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 36.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 36.00 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 6.00 Bbl | REUSE (AT WELL PAD) | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 121.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 102.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2120892 | Primary Facility | 2012-11-30 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Surface casing was currently at 20feet from grade. |
2121599 | Primary Facility | 2012-11-28 | Routine/Complete Inspection | No Violations Noted | Inspection result of spud notification. Multi-well pad. |
2123110 | Primary Facility | 2012-12-12 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Conductor was set in well and Chevron was drilling 2H well. |
2128474 | Primary Facility | 2012-12-17 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Conductor was set in well and Chevron was drilling 2H well. |
2128635 | Primary Facility | 2013-01-08 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Conductor was set in well and Chevron was drilling 5H well. |
2128642 | Primary Facility | 2013-01-08 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Conductor was set in well and Chevron was drilling 5H well. |
2130321 | Primary Facility | 2013-01-14 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Conductor was set in well and Chevron was drilling 5H well. |
2143502 | Primary Facility | 2013-02-11 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Conductor was set in well and Chevron was drilling 4H well. |
2143519 | Primary Facility | 2013-02-22 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Conductor (24”) was cemented in to a depth of 66 feet. Water protection pipe (20”) was set at 409 feet. The pipe was cemented with 329 sacks of Class A with 22 bbl. return. Mining protection pipe (11 ¾”) was set at 676 feet. The cement basket was set at 552 feet. No void was encountered. The pipe was cemented with 329 sacks of Class A with 16 bbl. The surface pipe (8 5/8”) was set at 1903 feet. The pipe was cemented with 503 sacks of Class A with 25 bbl. Return. |
2144644 | Primary Facility | 2013-02-25 | Routine/Complete Inspection | No Violations Noted | Multi-well pad. Site ID sign, valid permit, E&S plan, ESCGPI, PPC plan all present. Security on-site.At time of inspection, in process of skidding rig to resume drilling. 6H spudded, TD not yet reached. 1H had been drilled. 2H, 3H, 4H, 5H also all spudded, TDs not yet reached.Observed small staining on gravel on front edge of rig containment when standing at DSM trailer and noted large snow/gravel pile against brine tanks in back corner of pad which could lead to a potential pollution event by falling into ditches after thawing. Spoke to DSM Ken Silvis who agreed to place the affected gravel on containment and agreed to remove the snow pile.Noted erosion issue from previous inspection on 11/28/12 (ID 2121599) was addressed by utilizing an erosion blanket for stabilization and removing sediment from ditch.Rig and on-site tanks on containment. Tanks and containment appear structurally sound. Access road adequately rocked and no accelerated E&S issues were noted.Department recommends that Operator remove debris from rock-lined ditches. |
2151592 | Primary Facility | 2013-03-13 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Chevron was drilling well 3H. |
2173650 | Primary Facility | 2013-06-10 | Routine/Complete Inspection | No Violations Noted | Routine inspection no issues noted. |
2181334 | Primary Facility | 2013-05-22 | Routine/Complete Inspection | No Violations Noted | Met on site with Chevron. Signed off on a minor modification to the restoration plan. |
2228157 | Primary Facility | 2013-11-26 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Chevron was drilling well 4H. |
2228274 | Primary Facility | 2013-10-31 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Chevron was drilling well 3H. |
2228740 | Primary Facility | 2013-10-09 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Chevron was drilling well 6H. Well was drilled to 13,065 ft TD, and casing of 13,046 ft. The production pipe was cemented with 1255 sks lead and 545 sks tail to surface. Chevron was moving to 4H-A well. |
2229869 | Primary Facility | 2013-09-26 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Chevron was setting up drilling for well 4H. |
2235866 | Primary Facility | 2014-01-13 | Routine/Complete Inspection | No Violations Noted | On 1/13/14 inspected this 6 well, well pad. The weather the day of the inspection was unusually warm and wet. |
2244514 | Primary Facility | 2014-02-10 | Routine/Complete Inspection | No Violations Noted | Met with Curtis Small and inspected the well pad. Chevron was setting up on the well pad to frack a number of wells. The frack tanks will block access to the the pipeline companies access to their pipeline controls. Chevron propsed adding an additional ramp tp allow the pipeline company access to their well controls. The access road will only be temporary. |
2251005 | Primary Facility | 2014-03-05 | Routine/Complete Inspection | No Violations Noted | On 3/5/14 met with Joe Brusco with Chevron and inspected the site. |
2252451 | Primary Facility | 2014-03-10 | Routine/Complete Inspection | No Violations Noted | On 3/10/14 met with Alex Grant with Chevron and inspected the site. |
2298122 | Primary Facility | 2014-08-20 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Chevron was in process of fracking well 5H. Well 1H was temporary shut in. Wells 4HA, 3H and 6H have been completed. Well 2H will be completed the following week. |
2311288 | Primary Facility | 2014-10-08 | Routine/Complete Inspection | No Violations Noted | Work was underway to equip a well for production. A coil tubing rig was located onsite. Secondary containment was located on the well pad and there were 10 green and 4 red trailer tanks located onsite on top of the containment. There was no observed accelerated erosion or sedimentation in relation to the site or access road. It was noted that above and on either side of the site there was a cultivated crop field with soybeans. |
2408937 | Primary Facility | 2015-09-18 | Routine/Complete Inspection | No Violations Noted | At time of inspection, well tag present and legible. |
2486268 | Primary Facility | 2016-05-19 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2532225 | Primary Facility | 2016-10-05 | Routine/Complete Inspection | No Violations Noted | system running |
2549718 | Primary Facility | 2016-12-29 | Routine/Complete Inspection | No Violations Noted | Multi-well Marcellus pad.
Site ID sign, E&S plan, PPC plan and ERP on site. At time of inspection no E&S issues observed on access road. Well pad gated. Pad rocked. Well tag present and legible. Brine tank located in secondary containment appears structurally sound. Department observed discharge from tank secondary containment onto well pad. See Inspection Record #2549692. |
2594472 | Primary Facility | 2017-04-25 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2594595 | Primary Facility | 2017-05-16 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2626059 | Primary Facility | 2017-08-16 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2656147 | Primary Facility | 2017-11-02 | Routine/Complete Inspection | No Violations Noted | System running. No,issues |
2672040 | Primary Facility | 2017-12-18 | Routine/Complete Inspection | No Violations Noted | System running. No,issues. |
2672072 | Primary Facility | 2017-12-18 | Routine/Complete Inspection | No Violations Noted | Well appears to be in production. Well tender Matt Gary on site during inspection. DEP OGI P Wyrwas on site during inspection. |
2685391 | Primary Facility | 2018-01-23 | Routine/Complete Inspection | No Violations Noted | System producing. Emergency contact present. Well tag present. |
2700775 | Primary Facility | 2018-03-05 | Routine/Complete Inspection | No Violations Noted | Well tag present and emergency contact information present. No issues at the site |
2700824 | Primary Facility | 2018-03-05 | Routine/Complete Inspection | No Violations Noted | Multi-well site. Well pad gated. Well appears to be in production. Three brine tanks on site. Water truck on site during inspection. |
2719558 | Primary Facility | 2018-04-18 | Routine/Complete Inspection | No Violations Noted | Well appears equipped for production. Three brine tanks on site. Barrell located near brine tank labeled spill kit. Container labeled methanol located in secondary containment. |
2766922 | Primary Facility | 2018-08-23 | Routine/Complete Inspection | No Violations Noted | Well appears equipped for production. Three brine tanks on site. Department contacted operator rep Matt Gary by phone regarding potential E and S issues on access road and well pad. Mr. Gary states the access road and well pad areas will be inspected and any E and S issues will be addressed. |
For data sources see[7]