X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-105-21500

Well Details

Well ID: 37-105-21500
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Keating Township
Operator Name: PA GEN ENERGY CO LLC
Well Pad ID: 149166
Farm/Lease Name: REED RUN 2145
License Status:
Spud Date:
Permit Date: 2008-07-18
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.728198
Longitude: -78.168133

For data sources see[1][2][3]

Well History

Date Event
2008-07-18 New Permit Application
2008-09-12 Performed Spud Operation
2008-11-24 Drilling Completion
2009-01-22 DEVIATED
2009-06-29 Perforation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2009-06-29 2009-06-29 6,020 3,839,848

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 OptiKleen - WF Halliburton Energy Services Breaker / Biocide Sodium perborate tetrahydrate 10486-00-7 100.0 0.00485
BA-40L Halliburton Energy Services Buffer Potassium Carbonate 584-08-7 60.0 0.00787
Water* PGE Carrier/Base Fluid 7732-18-5 100.0 87.92031
LCA-1 Halliburton Energy Services Solvent Paraffinic Solvent Proprietary 100.0 None
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium Chloride 12125-02-9 10.0 0.00266
HAI-OS Halliburton Energy Services Corrosion Inhibitor Propargyl alcohol 107-19-7 10.0 0.00011
Hemicellulase Enzyme 9012-54-8 15.0 0.00009000
Naphtha, hydrotreated heavy 64742-48-9 60.0 0.00008000
Methanol 67-56-1 60.0 0.00067
Acid, Hydrochloric (3.0) Halliburton Energy Services Solvent Hydrochloric Acid 7647-01-0 3.0 0.03831
FR-46 Halliburton Energy Services Friction Reducer Ammonium bisulfate 7783-20-2 30.0 0.02508
LGC-35 Halliburton Energy Services Gelling Agent Guar Gum 9000-30-0 60.0 0.00008000
GBW-30 Halliburton Energy Services Gelling Agent Carbohydrates Proprietary 95.0 0.00001000
Sand Halliburton Energy Services Proppant Crystalline Silica (quartz) 14808-60-7 100.0 10.67341
SP Breaker Halliburton Energy Services Gel Breaker Sodium Persulfate 7775-27-1 100.0 0.00001000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 PA GEN ENERGY CO LLC 0.00 0 0.00 0 0.00 0
2009 PA GEN ENERGY CO LLC 0.00 0 0.00 0 0.00 0
2010 PA GEN ENERGY CO LLC 0.00 0 0.00 0 0.00 0
2011 PA GEN ENERGY CO LLC 0.00 0 0.00 0 0.00 0
2012 PA GEN ENERGY CO LLC 171,179.00 293 0.00 0 0.00 0
2013 PA GEN ENERGY CO LLC 71,970.00 227 0.00 0 0.00 0
2014 PA GEN ENERGY CO LLC 26,340.00 228 0.00 0 0.00 0
2015 PA GEN ENERGY CO LLC 102,895.00 331 0.00 0 0.00 0
2016 PA GEN ENERGY CO LLC 41,142.00 364 0.00 0 0.00 0
2017 PA GEN ENERGY CO LLC 81,289.00 360 0.00 0 0.00 0
2018 PA GEN ENERGY CO LLC 68,317.00 358 0.00 0 0.00 0
2019 PA GEN ENERGY CO LLC 57,514.00 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2008 PA GEN ENERGY CO LLC Drilling 493.00 Bbl Brine or Industrial Waste Treatment Plt PA0102784
2008 PA GEN ENERGY CO LLC Fracking Fluid 105.00 Bbl Brine or Industrial Waste Treatment Plt PA0102784
2009 PA GEN ENERGY CO LLC Drilling 926.00 Bbl Brine or Industrial Waste Treatment Plt PA0101508
2009 PA GEN ENERGY CO LLC Fracking Fluid 999.00 Bbl Brine or Industrial Waste Treatment Plt PA0101508
2009 PA GEN ENERGY CO LLC Fracking Fluid 14,840.00 Bbl Brine or Industrial Waste Treatment Plt PA0102784
2010 PA GEN ENERGY CO LLC Drilling Fluid Waste 14,091.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2010 PA GEN ENERGY CO LLC Drilling Fluid Waste 671.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 PA GEN ENERGY CO LLC Produced Fluid 4,862.78 Bbl REUSE OTHER THAN ROAD SPREADING
2012 PA GEN ENERGY CO LLC Produced Fluid 3,150.67 Bbl INJECTION DISPOSAL WELL 34-155-21447
2012 PA GEN ENERGY CO LLC Produced Fluid 416.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012 PA GEN ENERGY CO LLC Produced Fluid 989.00 Bbl INJECTION DISPOSAL WELL 34-151-23420
2012 PA GEN ENERGY CO LLC Fracturing Fluid Waste 0.88 Tons TREATED ON-SITE, NPDES DISCHARGE 301280
2012 PA GEN ENERGY CO LLC Fracturing Fluid Waste 7.35 Tons LANDFILL CID # 28726
2012 PA GEN ENERGY CO LLC Produced Fluid 1,346.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012 PA GEN ENERGY CO LLC Produced Fluid 4,799.19 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012 PA GEN ENERGY CO LLC Produced Fluid 6,402.15 Bbl REUSE OTHER THAN ROAD SPREADING
2012 PA GEN ENERGY CO LLC Fracturing Fluid Waste 0.88 Tons TREATED ON-SITE, NPDES DI 301280
2012 PA GEN ENERGY CO LLC Produced Fluid 416.00 Bbl INJECTION DISPOSAL WELL 34-155-23203
2012 PA GEN ENERGY CO LLC Produced Fluid 1,150.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2012 PA GEN ENERGY CO LLC Drill Cuttings 2,052.25 Tons LANDFILL 100361
2012 PA GEN ENERGY CO LLC Produced Fluid 1,999.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2012 PA GEN ENERGY CO LLC Produced Fluid 416.00 Bbl INJECTION DISPOSAL WELL 34-155-21894
2012 PA GEN ENERGY CO LLC Produced Fluid 1,123.00 Bbl INJECTION DISPOSAL WELL 34-133-20525
2013 PA GEN ENERGY CO LLC Produced Fluid 2,504.21 Bbl REUSE OTHER THAN ROAD SPREADING
2013 PA GEN ENERGY CO LLC Produced Fluid 143.33 Bbl INJECTION DISPOSAL WELL 34-155-21447
2013 PA GEN ENERGY CO LLC Produced Fluid 2,868.34 Bbl INJECTION DISPOSAL WELL 34-155-23795
2013 PA GEN ENERGY CO LLC Produced Fluid 185.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2013 PA GEN ENERGY CO LLC Produced Fluid 899.71 Bbl INJECTION DISPOSAL WELL 34-155-23203
2013 PA GEN ENERGY CO LLC Produced Fluid 1,411.66 Bbl INJECTION DISPOSAL WELL 34-151-23420
2013 PA GEN ENERGY CO LLC Produced Fluid 899.71 Bbl INJECTION DISPOSAL WELL 34-155-21893
2013 PA GEN ENERGY CO LLC Produced Fluid 899.71 Bbl INJECTION DISPOSAL WELL 34-155-21894
2013 PA GEN ENERGY CO LLC Produced Fluid 1,446.67 Bbl INJECTION DISPOSAL WELL 34-133-20525
2014 PA GEN ENERGY CO LLC Produced Fluid 135.98 Bbl INJECTION DISPOSAL WELL 34-155-21894
2014 PA GEN ENERGY CO LLC Produced Fluid 73.33 Bbl INJECTION DISPOSAL WELL 34-007-24355
2014 PA GEN ENERGY CO LLC Produced Fluid 111.67 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 PA GEN ENERGY CO LLC Produced Fluid 73.33 Bbl INJECTION DISPOSAL WELL 34-155-23759
2014 PA GEN ENERGY CO LLC Produced Fluid 217.94 Bbl INJECTION DISPOSAL WELL 34-155-23732
2014 PA GEN ENERGY CO LLC Produced Fluid 1,989.60 Bbl REUSE OTHER THAN ROAD SPREADING
2014 PA GEN ENERGY CO LLC Produced Fluid 183.33 Bbl INJECTION DISPOSAL WELL 34-155-23223
2014 PA GEN ENERGY CO LLC Produced Fluid 3,305.66 Bbl INJECTION DISPOSAL WELL 34-007-21847
2014 PA GEN ENERGY CO LLC Produced Fluid 135.98 Bbl INJECTION DISPOSAL WELL 34-155-21893
2014 PA GEN ENERGY CO LLC Produced Fluid 113.33 Bbl INJECTION DISPOSAL WELL 34-151-23420
2014 PA GEN ENERGY CO LLC Produced Fluid 404.60 Bbl INJECTION DISPOSAL WELL 34-155-23795
2014 PA GEN ENERGY CO LLC Produced Fluid 36.67 Bbl INJECTION DISPOSAL WELL 34-155-22403
2014 PA GEN ENERGY CO LLC Produced Fluid 245.00 Bbl INJECTION DISPOSAL WELL 34-133-20525
2014 PA GEN ENERGY CO LLC Produced Fluid 135.98 Bbl INJECTION DISPOSAL WELL 34-155-23203
2015 PA GEN ENERGY CO LLC Produced Fluid 308.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 PA GEN ENERGY CO LLC Produced Fluid 247.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 PA GEN ENERGY CO LLC Produced Fluid 1,400.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015 PA GEN ENERGY CO LLC Produced Fluid 2,202.33 Bbl REUSE OTHER THAN ROAD SPREADING
2015 PA GEN ENERGY CO LLC Produced Fluid 1,388.66 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 PA GEN ENERGY CO LLC Produced Fluid 336.67 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 PA GEN ENERGY CO LLC Produced Fluid 7.00 Bbl INJECTION DISPOSAL WELL 34-007-23262
2016 PA GEN ENERGY CO LLC Produced Fluid 7.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3177
2016 PA GEN ENERGY CO LLC Produced Fluid 140.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2016 PA GEN ENERGY CO LLC Produced Fluid 285.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 PA GEN ENERGY CO LLC Produced Fluid 3,594.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 PA GEN ENERGY CO LLC Produced Fluid 7.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2016 PA GEN ENERGY CO LLC Produced Fluid 7.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2016 PA GEN ENERGY CO LLC Produced Fluid 7.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3692
2017 PA GEN ENERGY CO LLC Produced Fluid 4,642.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 PA GEN ENERGY CO LLC Produced Fluid 41.67 Bbl REUSE (AT WELL PAD)
2017 PA GEN ENERGY CO LLC Produced Fluid 179.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 PA GEN ENERGY CO LLC Other Oil & Gas Wastes 36.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 PA GEN ENERGY CO LLC Produced Fluid 2,906.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 PA GEN ENERGY CO LLC Produced Fluid 523.34 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018 PA GEN ENERGY CO LLC Produced Fluid 866.67 Bbl REUSE (AT WELL PAD)
2018 PA GEN ENERGY CO LLC Other Oil & Gas Wastes 36.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 PA GEN ENERGY CO LLC Produced Fluid 115.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 PA GEN ENERGY CO LLC Produced Fluid 1,063.34 Bbl INJECTION DISPOSAL WELL 34-007-21847
2019 PA GEN ENERGY CO LLC Produced Fluid 386.66 Bbl INJECTION DISPOSAL WELL 34-155-24079
2019 PA GEN ENERGY CO LLC Produced Fluid 1,251.33 Bbl INJECTION DISPOSAL WELL PAS2D215BWAR
2019 PA GEN ENERGY CO LLC Produced Fluid 36.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 PA GEN ENERGY CO LLC Produced Fluid 525.01 Bbl REUSE (AT WELL PAD)
2019 PA GEN ENERGY CO LLC Produced Fluid 256.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1819508 Primary Facility 2009-08-06 Routine/Complete Inspection Violation(s) Noted
1826567 Primary Facility 2009-09-01 Compliance Evaluation Violation(s) Noted Initially observed and subsequently referred to me by MAB (Insp ID 819508). Failure to obtain Chapter 105 permit for encroachment into EV wetland & associated headwater stream, referred to Nancy Mullens of US Army Corps Pittsburgh Dist. Cleared by EPA via 3/18/10 e-mail on file.
1875008 Primary Facility 2010-04-05 Compliance Evaluation De minimus Violations Noted
1928105 Primary Facility 2010-11-16 Complaint Inspection Violation(s) Noted Failure to submit site restoration report
1966380 Primary Facility 2011-04-13 Routine/Partial Inspection Outstanding Violations - No Viols Req'd Still waiting on corected restoration report on current well site restoration report form
1970563 Primary Facility 2011-04-25 Routine/Partial Inspection Outstanding Violations - No Viols Req'd
2029645 Primary Facility 2011-12-20 Routine/Complete Inspection No Violations Noted
2068199 Primary Facility 2012-04-30 Routine/Partial Inspection No Violations Noted A partial inspection was conducted at the Reed Run 2145 pad (105-21500) on April 30, 2012 in response to a concern forward to the Department by the landowner (DCNR) that an area where an unusual amount of deer activity was observed. It was determined by PGE that this area was where an encapsulated pit containing drill cuttings for the above referenced well, pea gravel and frac sand was buried. Prior to this inspection the decision was made by PGE to remove the pit. The area in question, as shown in the attached photos, had standing water in the location and there were many deer tracts present. Jeff Munksgard, from PGE, was onsite and the plan to remove the pit was discussed. The plan is to partially excavate the area in order to sample the material that would be disposed of, and once the laboratory results were received, the remaining material would be disposed at an appropriate landfill. No new violations were cited during this inpsection. A follow-up inspection will be conducted.
2068202 Primary Facility 2012-05-14 Routine/Partial Inspection No Violations Noted A partial inspection was conducted at the Reed Run 2145 pad (105-21500) on May 14, 2012. A containment area was being constructed to allow trucks to park while the excavated drill cuttings will be loaded during the excavation. The freshwater impoundment has been drained and the impoundment removed and area backfilled. The excavation of the drill pit is on-hold at this time until road bonding issues have been resolved. No new violations were cited during this inspection.
2070506 Primary Facility 2012-05-23 Routine/Partial Inspection No Violations Noted A partial inspection was conducted at the Reed Run 2145 pad (105-21500) on May 23, 2012. A containment area was constructed to allow trucks to park while the excavated drill cuttings will be loaded during the excavation. The excavation of the drill pit began Monday 5/21/12 and at the time of this inspection was approximately 80% complete. Liquids present in the excavated area as a result of heavy rains the day before this inspection were being absorbed with wood pellet material. The excavated material was being loaded into lined dump trucks that were parked on containment. Approximately 40 trucks have been loaded so far. Jeff Munksgard from PGE was on-site and indicated a filed meter would be used to measure the conductivity of the soil in order to determine the extent of excavation. It was estimated that the excavation would be completed by the end of the day. PGE stated they expect to collect confirmatory samples on Friday 5/25/12. No new violations were cited during this inspection. - MRN
2071406 Primary Facility 2012-05-29 Routine/Partial Inspection No Violations Noted A partial inspection was conducted at the Reed Run 2145 pad (105-21500) on May 29, 2012. The drill cuttings and liner have been removed. PGE had confirmatory soil samples collected by DMS Environmental Services on Friday 25, 2012. During today’s inspection, a soil sample was collected near the west corner of the excavated area and submitted for SAC 960 analysis. No unusually staining of the soil was observed. No new violations were cited during this inspection. - MRN
2077762 Primary Facility 2012-06-21 Follow-up Inspection No Violations Noted A follow-up inspection was conducted at the Reed Run 2145 pad (105-21500) on June 21, 2012. The pit was nearly full of water during this inspection. The water was screened and no elevated conductivity was noted. An excavator was on site and disabled. There was staining observed on the soil directly below the bucket. This material and any contaminated soil should be collected and disposed of properly. No new violations were cited during this inspection.
2083328 Primary Facility 2012-07-16 Follow-up Inspection No Violations Noted A follow-up inspection was conducted at the Reed Run 2145 pad (105-21500) on July 16, 2012. The excavation of the drill cuttings pit has been completed. Soil samples were collected on behalf of PGE and the results submitted to the Department. The area has been returned to grade and is awaiting further stabilization. A minimum uniform 70% perennial vegetative cover, with a density capable of resisting accelerated erosion and sedimentation should be established. A follow-up inspection will be conducted at a later date to verify this has occurred. A final report is being prepared and will be submitted to the Department. No new violations were cited during this inspection. - MRN
2513348 Primary Facility 2016-08-22 Routine/Complete Inspection No Violations Noted Routine inspection. Reed Run Keating Pad A. Site is restored and wells are in production. TLT
2609331 Primary Facility 2017-06-12 Routine/Complete Inspection No Violations Noted
2648622 Primary Facility 2017-10-17 Routine/Complete Inspection No Violations Noted On 10/17/17 at 1036 hrs I conducted an inspection at the Reed Run Keating Pad A well site. It was sunny and 37 degrees F. No one was present during my inspection.

The wells have been drilled, tagged and equipped for production. The production equipment has built-in containment, which appeared to be in good condition. Three production tanks are staged in containment. The containment held several inches of water; field measured specific conductance was 2.72 mS/cm. No staining or evidence of spills was noted on the pad surface.

The freshwater impoundment located north of the well site was observed. The access road entrance off of Card Creek Road was gated. The perimeter of the impoundment site is fenced, however a portion of the fence has fallen down and should be re-erected. It appeared that the impoundment held about a foot of water. The liner was patched in numerous places and several holes were observed. The holes were above the current water level, although a few would be below the water if the impoundm

2685907 Primary Facility 2018-01-23 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly all fittings and flow lines were tested for gas. Results of this testing was no gas was detected on the wellhead assembly or the well area.
2747751 Primary Facility 2018-06-29 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. No violations were noted at this inspection.
2826526 Primary Facility 2019-01-14 Routine/Complete Inspection No Violations Noted At the time of this inspection this well appeared to be in production. A mechanical gauge on the well was reading 1100 psi ( pounds per square inch) at this inspection. The annular vents are not vented to surface at the well and are hard piped (plumbed) from the well to a production/ waste tank (s) on the pad. No violations were noted at this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1819508 569102 08/06/2009 2009-08-06 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety See Insp ID 1826567, US EPA Enf cleared via 3/18/10 e-mail, case closed. 102.4(b)(1) failure to implement and maintain erosion and control BMPs required to minimixe the potential for acclerated erosion. MBC 8/13/09
1819508 569103 08/06/2009 2009-08-06 102.4INADPLN - E&S Plan not adequate Administrative See Insp ID 1826567, US EPA Enf cleared via 3/18/10 e-mail, case closed. 102.4(b)(5) Failure to adequately depict site conditions on E&S plan. MBC 8/13/09
1826567 570996 09/01/2009 2009-09-01 105NOPERMIT - Encroachment without Permit or Waiver Environmental Health & Safety Addressed thru EPA enforcement. Viol cleared via EPA e-mail dated 3/18/10.
1928105 599541 11/16/2010 2010-11-16 78.65(3)* - Failure to submit or submitting an inadequate well site restoration report within 60 days of restoration of the well site Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
569102 249008 NOV - Notice of Violation Comply/Closed 2010-03-18
569103 249008 NOV - Notice of Violation Comply/Closed 2010-03-18

For data sources see[8]

References