If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
(8 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | __TOC__ | ||
== Well Details == | == Well Details == | ||
− | {| class="wikitable" width="95%" | + | {| class="wikitable welldetails" width="95%" |
| Well ID: 37-065-24705 | | Well ID: 37-065-24705 | ||
− | | style=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 41.006130, -78.9683 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | | + | | State: Pennsylvania |
|- | |- | ||
− | | | + | | County: [[Jefferson_County,_Pennsylvania|Jefferson]] |
|- | |- | ||
− | | | + | | Municipality: [[McCalmont Township,_Jefferson_County,_Pennsylvania|McCalmont Township]] |
|- | |- | ||
− | | | + | | Operator Name: [[DANNIC ENERGY CORP]] |
|- | |- | ||
− | | | + | | Well Pad ID: |
|- | |- | ||
− | | | + | | Farm/Lease Name: FERRARA 2 |
|- | |- | ||
− | | | + | | License Status: ACTIVE |
|- | |- | ||
− | | | + | | Spud Date: 2001-11-12 |
|- | |- | ||
− | | | + | | Permit Date: 2001-08-29 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | Well Type: COMB. OIL&GAS |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | Unconventional Well: N | ||
|- | |- | ||
− | | | + | | Configuration: Vertical Well |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | Conservation: No | ||
|- | |- | ||
− | | | + | | Latitude: 41.006130 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | Longitude: -78.9683 | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
|- | |- | ||
− | | | + | | 2001-08-29 |
− | + | | New Permit Application | |
− | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2001-11-09 | ||
+ | | Performed Spud Operation | ||
|- | |- | ||
− | | | + | | 2001-11-15 |
− | + | | Drilling Completion | |
− | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2001-12-07 | ||
+ | | Perforation | ||
|- | |- | ||
− | | | + | | 2002-05-18 |
− | + | | NEWLY DRILLED | |
− | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
+ | <!--== Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
|- | |- | ||
− | | | + | |}--> |
− | | | + | <!--==== Fluid Composition Data ==== |
− | | | + | {| class="wikitable sortable" width="95%" |
− | | | + | !scope="col" | Job Number |
− | | | + | !scope="col" | Trade Name |
− | + | !scope="col" | Supplier | |
− | + | !scope="col" | Purpose | |
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
|- | |- | ||
+ | |}--> | ||
+ | |||
+ | <!--== Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
|- | |- | ||
− | | | + | |}--> |
− | + | ||
− | + | == Production Data == | |
− | | | + | {| class="wikitable sortable" width="95%" |
− | + | !scope="col" | Period | |
− | + | !scope="col" | Operator Name | |
− | + | !scope="col" | Gas Quantity (mcf) | |
− | + | !scope="col" | Gas Production Days | |
− | + | !scope="col" | Oil Quantity (bbl) | |
− | + | !scope="col" | Oil Production Days | |
− | + | !scope="col" | Water Quantity (bbl) | |
− | + | !scope="col" | Water Production Days | |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2001 | ||
+ | | [[DANNIC ENERGY CORP]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2003 |
− | | style="text-align:right;" | | + | | [[DANNIC ENERGY CORP]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 16321 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2004 | ||
+ | | [[DANNIC ENERGY CORP]] | ||
+ | | style="text-align: right;" | 13,727.95 | ||
+ | | style="text-align: right;" | 366 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2005 |
− | | style="text-align:right;" | | + | | [[EXCO RESOURCES PA INC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2006 | ||
+ | | [[EXCO RESOURCES PA INC]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2007 |
− | | style="text-align:right;" | | + | | [[DANNIC ENERGY CORP]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 7767.04 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 304 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2008 | ||
+ | | [[DANNIC ENERGY CORP]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2009 |
− | | style="text-align:right;" | 0. | + | | [[DANNIC ENERGY CORP]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2010 | ||
+ | | [[DANNIC ENERGY CORP]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2011 |
− | | style="text-align:right;" | | + | | [[DANNIC ENERGY CORP]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2012 | ||
+ | | [[EXCO RESOURCES PA LLC]] | ||
+ | | style="text-align: right;" | 1,979.00 | ||
+ | | style="text-align: right;" | 213 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2013 |
− | | style="text-align:right;" | | + | | [[EXCO RESOURCES PA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,414.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 275 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2014 | ||
+ | | [[EXCO RESOURCES PA LLC]] | ||
+ | | style="text-align: right;" | 1,169.00 | ||
+ | | style="text-align: right;" | 153 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2015 |
− | | style="text-align:right;" | | + | | [[EXCO RESOURCES PA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 999.64 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 212 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2016 | ||
+ | | [[DANNIC ENERGY CORP]] | ||
+ | | style="text-align: right;" | 6,729.00 | ||
+ | | style="text-align: right;" | 366 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | style="text-align:right;" | | + | | [[DANNIC ENERGY CORP]] |
− | | style="text-align:right;" | 365 | + | | style="text-align: right;" | 5,005.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2018 | ||
+ | | [[DANNIC ENERGY CORP]] | ||
+ | | style="text-align: right;" | 5,103.09 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2019 |
− | | style="text-align:right;" | | + | | [[DANNIC ENERGY CORP]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 5,228.69 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Production Reports | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-03-31 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator |
− | !scope="col" | | + | !scope="col" | Waste Type |
− | !scope="col" | | + | !scope="col" | Quantity |
− | !scope="col" | | + | !scope="col" | Disposal Method |
− | !scope="col" | | + | !scope="col" | Waste Facility ID |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2003 | ||
+ | | [[DANNIC ENERGY CORP]] | ||
+ | | Brine | ||
+ | | style="text-align: right;" | 120.00 Bbl | ||
+ | | Municipal Sewage Treatment Plant | ||
+ | | PA0028207 | ||
|- | |- | ||
− | | 2004 | + | | 2004 |
− | | | + | | [[DANNIC ENERGY CORP]] |
− | | style="text-align:right;" | 70. | + | | Brine |
− | + | | style="text-align: right;" | 70.00 Bbl | |
− | | | + | | Brine or Industrial Waste Treatment Plt |
− | + | | PA0101508 | |
− | |||
− | |||
− | | | ||
|- | |- | ||
+ | | 2008 | ||
+ | | [[EXCO RESOURCES PA INC]] | ||
+ | | Brine | ||
+ | | style="text-align: right;" | 80.00 Bbl | ||
+ | | Brine or Industrial Waste Treatment Plt | ||
+ | | PA0095273 | ||
|- | |- | ||
− | | 2008 | + | | 2008 |
− | + | | [[DANNIC ENERGY CORP]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 40.00 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | | ||
− | | style="text-align:right;" | 40. | ||
− | |||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| PA0095273 | | PA0095273 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2009 |
− | | | + | | [[EXCO RESOURCES PA INC]] |
− | | | + | | Brine |
− | | style="text-align:right;" | 40. | + | | style="text-align: right;" | 40.00 Bbl |
− | + | | Other | |
− | | | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Waste Reports | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-03-31 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Inspection Data == | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Inspection ID |
− | !scope="col" | | + | !scope="col" | Inspection Category |
− | !scope="col" | | + | !scope="col" | Inspection Date |
− | !scope="col" | | + | !scope="col" | Inspection Type |
− | !scope="col" | | + | !scope="col" | Inspection Result |
+ | !scope="col" | Inspection Comments | ||
|- | |- | ||
| 1075730 | | 1075730 | ||
+ | | Primary Facility | ||
| 2001-11-13 | | 2001-11-13 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| | | | ||
+ | |- | ||
+ | | 1202966 | ||
+ | | Primary Facility | ||
+ | | 2003-01-29 | ||
+ | | Administrative/File Review | ||
+ | | Violation(s) Noted | ||
| | | | ||
|- | |- | ||
+ | | 2771989 | ||
+ | | Primary Facility | ||
+ | | 2018-09-06 | ||
+ | | Routine/Partial Inspection | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, well was producing. Well integrity appeared to be in good condition, with no signs of any leaks. Corrosion was in the form of superficial rust. The well was properly labeled. There was a separator which had a gauge reading 50 psi. There was also a drip tank and a 50 bbl plastic tank hooked up. The chart onsite was changed on 8/30. Production was reported for 2017 as 5005 mcf for 365 days. | ||
+ | |- | ||
+ | |} | ||
+ | ==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Violation Date | ||
+ | !scope="col" | Date Resolved | ||
+ | !scope="col" | Violation Code | ||
+ | !scope="col" | Violation Type | ||
+ | !scope="col" | Violation Comments | ||
|- | |- | ||
| 1202966 | | 1202966 | ||
+ | | 333556 | ||
+ | | 01/29/2003 | ||
| 2003-01-29 | | 2003-01-29 | ||
− | | | + | | 78.65(3)* - Failure to submit or submitting an inadequate well site restoration report within 60 days of restoration of the well site |
+ | | Administrative | ||
+ | | Site restoration report not submitted to the Department within 60 days of site restoration. | ||
+ | |- | ||
+ | |} | ||
+ | ==== Penalties Applied ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Penalty ID | ||
+ | !scope="col" | Penalty Code | ||
+ | !scope="col" | Penalty Status | ||
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
+ | |- | ||
+ | | 333556 | ||
+ | | 108396 | ||
+ | | NOV - Notice of Violation | ||
+ | | Administrative Close Out | ||
| | | | ||
− | | | + | | 2011-01-14 |
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Compliance Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
==References== | ==References== | ||
− | + | <references/> | |
− | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
+ | [[Category:Pennsylvania Wells]] |
Well ID: 37-065-24705 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.00613,"lon":-78.9683,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Jefferson | |
Municipality: McCalmont Township | |
Operator Name: DANNIC ENERGY CORP | |
Well Pad ID: | |
Farm/Lease Name: FERRARA 2 | |
License Status: ACTIVE | |
Spud Date: 2001-11-12 | |
Permit Date: 2001-08-29 | |
Well Type: COMB. OIL&GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.006130 | |
Longitude: -78.9683 |
Date | Event |
---|---|
2001-08-29 | New Permit Application |
2001-11-09 | Performed Spud Operation |
2001-11-15 | Drilling Completion |
2001-12-07 | Perforation |
2002-05-18 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2001 | DANNIC ENERGY CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2003 | DANNIC ENERGY CORP | 16321 | 365 | 0.00 | 0 | 0.00 | 0 |
2004 | DANNIC ENERGY CORP | 13,727.95 | 366 | 0.00 | 0 | 0.00 | 0 |
2005 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2006 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2007 | DANNIC ENERGY CORP | 7767.04 | 304 | 0.00 | 0 | 0.00 | 0 |
2008 | DANNIC ENERGY CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2009 | DANNIC ENERGY CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | DANNIC ENERGY CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | DANNIC ENERGY CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 1,979.00 | 213 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 1,414.00 | 275 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 1,169.00 | 153 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 999.64 | 212 | 0.00 | 0 | 0.00 | 0 |
2016 | DANNIC ENERGY CORP | 6,729.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | DANNIC ENERGY CORP | 5,005.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | DANNIC ENERGY CORP | 5,103.09 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | DANNIC ENERGY CORP | 5,228.69 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2003 | DANNIC ENERGY CORP | Brine | 120.00 Bbl | Municipal Sewage Treatment Plant | PA0028207 |
2004 | DANNIC ENERGY CORP | Brine | 70.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0101508 |
2008 | EXCO RESOURCES PA INC | Brine | 80.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0095273 |
2008 | DANNIC ENERGY CORP | Produced Fluid | 40.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2009 | EXCO RESOURCES PA INC | Brine | 40.00 Bbl | Other |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1075730 | Primary Facility | 2001-11-13 | Drilling/Alteration | No Violations Noted | |
1202966 | Primary Facility | 2003-01-29 | Administrative/File Review | Violation(s) Noted | |
2771989 | Primary Facility | 2018-09-06 | Routine/Partial Inspection | No Violations Noted | At the time of inspection, well was producing. Well integrity appeared to be in good condition, with no signs of any leaks. Corrosion was in the form of superficial rust. The well was properly labeled. There was a separator which had a gauge reading 50 psi. There was also a drip tank and a 50 bbl plastic tank hooked up. The chart onsite was changed on 8/30. Production was reported for 2017 as 5005 mcf for 365 days. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1202966 | 333556 | 01/29/2003 | 2003-01-29 | 78.65(3)* - Failure to submit or submitting an inadequate well site restoration report within 60 days of restoration of the well site | Administrative | Site restoration report not submitted to the Department within 60 days of site restoration. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
333556 | 108396 | NOV - Notice of Violation | Administrative Close Out | 2011-01-14 |
For data sources see[7]