X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-063-36434

Well Details

Well ID: 063-36434
Loading map...
County: Indiana
Municipality: Center Township
Operator Name: XTO ENERGY INC
Farm/Lease Name: HOMER CITY POWER PLANT 8422H
First Permit Date: 2009-02-09
Last Permit Date: 2009-02-09
Spud Date: 2009-09-11
Unconventional: Yes
Horizontal: Yes
Producing: Yes
Violations: 2
Latitude: 40.510643
Longitude: -79.186638

Well Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
1835933 2009-10-01 No Violations Noted MARCELLUS - drilling @ 7,237ft/E&S ok/ID&pit ok
1840492 2009-10-27 No Violations Noted Marcellus well. Drilling crew rigging down and removing equipment at time of inspection. Well head only on site.

Site ID sign in place. E&S plan on site. Access road is stabilized with rock. No signs of accelerated erosion on access road. Access road entrance is rocked. No signs of accelerated erosion leaving well site. Frac pit appeared sound with proper compaction, embankment width, slopes, freeboard, etc.. Drill pit appeared sound. Freeboard was nearing the minimum 2' allowed. Contacted operator representative Ben Kissel about this as well as on-site personnell. Additional BMP's need to be installed in order to prevent any erosion/sedimentation issues, as reflected on the E&S plan on site. Spoke to Mr. Kissel about this who then requested an on site meeting

1840500 2009-10-28 No Violations Noted Marcellus well. Drilling crew rigging down and removing equipment at time of inspection. Well head only on site.

Site ID sign in place. E&S plan on site. Access road, site, and pits ok. Inspection conducted with operator representative Ben Kissel, site construction manager, and consultants in order to address concerns found during the inspection of this site on 10/27/09. Fluids had been removed from the drill pit to ensure 2' freeboard. Discussed additional BMP's needed to be installed in order to prevent any erosion/sedimentation issues, and to reflect the E&S plan on site. Mr. Kissel indicated that additional BMP's would be installed. Please contact this office upon completion.

1943220 2011-01-03 Violation(s) Noted Marcellus well. Well is equipped for production. Drilling completed 10/25/2009.

Site ID sign and well tag in place. ESCGP-1 approval, permit and E&S plan on site. Access road was stabilized, with no signs of accelerated erosion. Inspection revealed the following deficiencies:

 1)  Failure to restore site and impoundment within 9 months of completion of drilling.  Large impoundment on site has not been backfilled and restored. Not permitted as centralized impoundment. Many disturbed areas around the site and production equipment are not vegetated.  Rock pad is sediment laden, and does not appear to be constructed of durable rock. 2) Failure to minize accelerated erosion, implement and maintain E&S controls, and stabilize site.  Nearly all of the silt fence that was installed is collapsed. Some of the BMP's shown on ESCGP-1 were not installed. Evidence of erosion/sedimentation found on banks and around equipment. Impoundment fluids must be removed and properly disposed of. Site, pad, impoundment must be properly restored.  Temporary BMP's mainta
603070
1943220 2011-01-03 Violation(s) Noted Marcellus well. Well is equipped for production. Drilling completed 10/25/2009.

Site ID sign and well tag in place. ESCGP-1 approval, permit and E&S plan on site. Access road was stabilized, with no signs of accelerated erosion. Inspection revealed the following deficiencies:

 1)  Failure to restore site and impoundment within 9 months of completion of drilling.  Large impoundment on site has not been backfilled and restored. Not permitted as centralized impoundment. Many disturbed areas around the site and production equipment are not vegetated.  Rock pad is sediment laden, and does not appear to be constructed of durable rock. 2) Failure to minize accelerated erosion, implement and maintain E&S controls, and stabilize site.  Nearly all of the silt fence that was installed is collapsed. Some of the BMP's shown on ESCGP-1 were not installed. Evidence of erosion/sedimentation found on banks and around equipment. Impoundment fluids must be removed and properly disposed of. Site, pad, impoundment must be properly restored.  Temporary BMP's mainta
603071
2043141 2012-02-02 Outstanding Violations - No Viols Req'd During this inspection, well drilled and equipped for prodcution. Well sign ES plan present. According to records drilling completed on 10/25/09. Prevoius violations issed on 1/03/11 by WQS Curtis Small for failure to restore site and impoundment within nine months of completion of drilling. At the time of this inspection, "frac pond" still located on well site and currently full of water. Line of "frac pond" appears structurally compromised with various holes. Site has been seeded/mulch with minimal growth, does not appear to be at least 70% unfiorm vegeatative cover. Share access road, could be maintained as mud and rutting apepars to be a concern. Minor E/S issues noted on site due to lack of vegettative stabilization. No temporary bmp's observed.

Department is requested written response on what restoration efforts are being planned for i"frac pond" as well as time of when these events will commence.

During this inspection, no new violations noted previously issued violations ongoing.

2071675 2012-05-09 Outstanding Violations - No Viols Req'd During this inspection, well drilled and equipped for production. Well sign ES plan present. Two brine tanks located onsite located with metal secondary containment. Site has been seeded/mulch with growth.No accelerated erosion or sedimentation concerns noted at this time. According to records drilling completed on 10/25/09. At the time of this inspection, "frac pond" still located on well site and currently full of water. Liner of "frac pond" appears to have been repaired since last inspection- holes appear to have been patched. Since last inspection department noted settling of "sandy" material-possibly indicating flowback material??? Operator claims pit is being used for freshwater only. Department has a meeting planned for May 11 with operator to discuss outstanding violations at this location. Department had requested written response on what restoration efforts are being planned for i"frac pond" as well as time of when these events will commence. Dept requesting sample anlaysis and disposal records for materials disposed of from this site
2089729 2012-08-01 Outstanding Violations - No Viols Req'd At the time of this inspection, well ID sign, ES plan, ESCGP-1 present. Inspection follow up on reclamation and relining of impoundment as per agreement with department. Impoundment currently lined with minimal fluid, as operator actively pumping fluids out and hauling off site to an approval facility. Six roll off boxes located onsite in preparation for removal of impoundment liner and any contaminants that may have entered grounds of the commonwealth due to structural deficiencies in liner. At the time of this inspection, no new violations noted. A follow up inspection will be conducted when liner has been successfully removed and samples collected prior to relining impoundment for re-use as freshwater impoundment

NO NEW VIOLS, OUSTANDING VIOLS EXIST B/C IMPOUNDMENT NOT YET RELINED AS PER (WRITTEN) AGREEMENT BTW OPR AND DEPT

2090948 2012-08-01 No Violations Noted WELL TAG PRESENT. TANKS OK. NO ACC ES. NO IW OPERATOR REMOVED LINER FROM IMPOUNDMENT, AWAITING OPERATOR RESPONSE ON SAMPLING RESULTS BENEATH LINER- ONCE SAMPLES ARE CONFIRMED WITHIN "LIMITS" OPERATOR WILL RELINE IMPOUNDMENT AND UTLIZED AS FRESHWATER.

RESULT PENDING UNTIL FINAL CONFIRMATION OF SAMPLE RESULTS.

2109943 2012-10-16 No Violations Noted At the time of this inspection, well ID sign, ES plan, ESCGP-1 present. Inspection follow up on reclamation and relining of impoundment as per agreement with department. It appears that impoundment has been successfully relined, minimal "fluids" present in freshwater impoundment, possibly that of precipitation. Areas previously disturbed have been seeded and mulch with observed growth. No accelerated erosion or sedimentation issues noted. It appears that operator has responded to previously issued notice of violation and no new violations are noted.

Accompanied by Environmental Trainee Samantha Foulk during this inspection.

2136165 2013-01-31 No Violations Noted At the time of this inspection, well ID sign, ES plan, ESCGP-1 present. Drilling completed 10/25/09, well currently in production. As per previous agreement (w/ dept.) operator has relined freshwater impoundment. All previously disturbed areas on and surrounding well site have been permanently stabilized with rock and/or vegetative growth. No accelerated erosion or sedimentation issues noted at the time of this inspection. Recommend that operator remove water (as per regulations) from metal containment dike surrounding production equipment and brine tank. Shared access road stable. No violations noted at the time of this inspection.


Accompanied by Environmental Trainee Samantha Foulk and OGI Rick Hoover.

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2012-2 64719.0 184.0 0.0 0.0 0.0 0.0
2012-1 67513.0 182.0 0.0 0.0 0.0 0.0
2011-2 71697.0 182.0 0.0 0.0 0.0 0.0
2011-1 88299.0 181.0 0.0 0.0 0.0 0.0
2010-2 104993.0 183.0 0.0 0.0 0.0 0.0
2010-3 126905.0 180.0 0.0 0.0 0.0 0.0
2009-0 0.0 0.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2012-2 PRODUCED FLUID 1651.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185 RESERVED ENVIRONMENTAL SERVICES MOUNT PLEASANT PA
2012-2 PRODUCED FLUID 111.0 Bbl INJECTION DISPOSAL WELL 34-133-20114 SALTY'S DISPOSAL - WILCOX #1 ROOTSTOWN OH
2012-2 PRODUCED FLUID 114.0 Bbl INJECTION DISPOSAL WELL 34-133-24096 SALTYS DISPOSAL - GROSELLE INECTION WELL # 2 GARRETTSVILLE OH
2010-3 DRILLING FLUID WASTE 7750.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273 PA BRINE TRT INC - JOSEPHINE PLT, INDIANA COUNTY JOSEPHINE PA
2010-3 PRODUCED FLUID 4640.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273 PA BRINE TRT INC - JOSEPHINE PLT, INDIANA COUNTY JOSEPHINE PA
2010-3 DRILLING FLUID WASTE 1771.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472 TUNNELTON LIQUIDS COMPANY SALTSBURG PA
2010-2 PRODUCED FLUID 1940.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273 PA BRINE TRT INC - JOSEPHINE PLT, INDIANA COUNTY JOSEPHINE PA
2011-1 PRODUCED FLUID 682.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273 PA BRINE TRT INC - JOSEPHINE PLT, INDIANA COUNTY JOSEPHINE PA
2011-1 PRODUCED FLUID 122.0 Bbl INJECTION DISPOSAL WELL 34-133-24096 SALTYS DISPOSAL - GROSELLE INECTION WELL # 2 GARRETTSVILLE OH
2011-1 PRODUCED FLUID 111.0 Bbl INJECTION DISPOSAL WELL 34-133-21076 SALTYS DISPOSAL - MYERS INECTION WELL #1 PARIS OH
2011-1 PRODUCED FLUID 148.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472 TUNNELTON LIQUIDS COMPANY SALTSBURG PA
2011-2 PRODUCED FLUID 100.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185 RESERVED ENVIRONMENTAL SERVICES MOUNT PLEASANT PA
2011-2 PRODUCED FLUID 654.0 Bbl INJECTION DISPOSAL WELL 34-133-24096 SALTYS DISPOSAL - GROSELLE INECTION WELL # 2 GARRETTSVILLE OH
2011-2 PRODUCED FLUID 348.0 Bbl INJECTION DISPOSAL WELL 34-133-21076 SALTYS DISPOSAL - MYERS INECTION WELL #1 PARIS OH
2012-1 PRODUCED FLUID 114.0 Bbl INJECTION DISPOSAL WELL 34-133-24096 GROSELLE #2 - SALTYS DISPOSAL WELLS LP GARRETTSVILLE OH
2012-1 PRODUCED FLUID 805.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185 RESERVED ENVIRONMENTAL SERVICES MOUNT PLEASANT PA
2012-1 PRODUCED FLUID 111.0 Bbl INJECTION DISPOSAL WELL 0114 WILCOX #1 ROOTSTOWN OH