X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-059-26014

Well Details

Well ID: 37-059-26014
Loading map...
County: Greene
Municipality: Morris Township
Operator Name: CNX GAS CO LLC
Well Pad ID: 148014
Farm/Lease Name: CONSOL MOR20ASH
First Permit Date: 2012-06-13
Last Permit Date: 2012-11-14
Spud Date: 2012-07-18
Unconventional: Yes
Horizontal: Yes
Well Status: ACTIVE
Violations: 0
Latitude: 39.953722
Longitude: -80.358444

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2012-1 0.0 0.0 0.0 0.0 0.0 0.0
2012-2 0.0 0.0 0.0 0.0 0.0 0.0
2013-1 0.0 0.0 0.0 0.0 0.0 0.0
2013-2 113593.5 184.0 0.0 0.0 0.0 0.0
2014-1 386121.81 181.0 0.0 0.0 0.0 0.0
2014-2 234364.56 184.0 0.0 0.0 0.0 0.0
2015-02 31542.07 28.0 0.0 0.0 0.0 0.0
2015-01 38664.56 31.0 0.0 0.0 0.0 0.0
2015-03 41473.46 31.0 0.0 0.0 0.0 0.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2012-2 DRILL CUTTINGS 1.0 Tons LANDFILL 100172 ARDEN LANDFILL WASHINGTON PA
2012-2 DRILL CUTTINGS 117.32 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2013-1 DRILL CUTTINGS 31.05 Tons LANDFILL 100172 ARDEN LANDFILL WASHINGTON PA
2013-2 FRACING FLUID WASTE 15.02 Bbl LANDFILL 100172 ARDEN LANDFILL WASHINGTON PA
2013-2 PRODUCED FLUID 84.4 Bbl INJECTION DISPOSAL WELL 34-031-27177 ADAMS #1 (SWIW #10) COSHOCTON OH
2013-2 PRODUCED FLUID 118.68 Bbl INJECTION DISPOSAL WELL 34-013-20609 BUCKEYE UIC BARNESVILLE #1 (SWIW#2) BARNESVILLE OH
2013-2 PRODUCED FLUID 4.38 Bbl INJECTION DISPOSAL WELL 34-119-28776 GOFF #1 (SWIW #27) NORWICH OH
2013-2 PRODUCED FLUID 4.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2013-2 PRODUCED FLUID 46.26 Bbl INJECTION DISPOSAL WELL 34-059-24202 SOS-D #1 (SWIW #12) CAMBRIDGE OH
2013-2 PRODUCED FLUID 330.35 Bbl INJECTION DISPOSAL WELL 34-105-23619 SWIW #19 MEIGS OH
2014-1 FLOWBACK FRACTURING SAND 20.58 Tons LANDFILL 100172 ARDEN LANDFILL WASHINGTON PA
2014-1 PRODUCED FLUID 74.0 Bbl INJECTION DISPOSAL WELL 34-013-20609 BUCKEYE UIC BARNESVILLE #1 (SWIW#2) BARNESVILLE OH
2014-1 PRODUCED FLUID 16.09 Bbl INJECTION DISPOSAL WELL 34-119-28776 GOFF #1 (SWIW #27) NORWICH OH
2014-1 PRODUCED FLUID 135.14 Bbl STORAGE PENDING DISPOSAL OR REUSE HUNTER DISPOSAL - NEW MATAMORAS NEW MATAMORAS OH
2014-1 PRODUCED FLUID 16.09 Bbl INJECTION DISPOSAL WELL 2D0859721 MASON WELL #1 (47-085-09721) ELLENBORO WV
2014-1 PRODUCED FLUID 821.28 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 PRODUCED FLUID 61.13 Bbl INJECTION DISPOSAL WELL 34-059-24202 SOS-D #1 (SWIW #12) CAMBRIDGE OH
2014-1 PRODUCED FLUID 19.31 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH
2014-2 PRODUCED FLUID 778.25 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
2087070 2012-07-24 No Violations Noted 30" CONDUCTOR SET TO 80'. WAITING ON TOP HOLE RIG TO COMMENCE DRILLING.SITE LOOKED GOOD AT TIME OF INSPECTION.
2107562 2012-09-27 No Violations Noted YOST RIG 5 DRILLED TOP HOLE TO COMPLETION FOR CONSOL. CEMENT AND CASING INFO GOOD. SITE LOOKED GOOD AT TIME OF INSPECTION.
2125845 2012-12-04 No Violations Noted TOP HOLE DRILLED. WAITING ON HORIZONTAL RIG TO COMPLETE DRILLING. SITE COMPLIANT AT TIME OF INSPECTION.
2198511 2013-07-30 In Compliance with Policy On July 26, 2013, the Department received a notification of a possible spill at CONSOL Energyï¾’s MOR 20 site. The event involved a rain puddle with a rainbow sheen on it, possible from heavy equipment parked there. CONSOL responded by excavating the dirt around the site and rechecking it.

On July 30, 2013, I checked the site but found nothing in conflict with CONSOLï¾’s description and response.

Upon review of all the information in relation to this spill incident, the operator performed the proper spill reporting requirements and has reported sufficient remediation at the area of release in compliance with the Departments current Spill Policy.

For data sources see[3]

References