X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-059-25928

Well Details

Well ID: 37-059-25928
Loading map...
County: Greene
Municipality: Center Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148889
Farm/Lease Name: MILESKY UNIT 2H
First Permit Date: 2012-03-15
Last Permit Date: 2012-03-15
Spud Date: 2012-04-27
Unconventional: Yes
Horizontal: Yes
Well Status: ACTIVE
Violations: 0
Latitude: 39.8612
Longitude: -80.245302

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2012-1 0.0 0.0 0.0 0.0 0.0 0.0
2012-2 0.0 0.0 0.0 0.0 0.0 0.0
2013-1 395892.0 91.0 0.0 0.0 0.0 0.0
2013-2 567921.0 184.0 0.0 0.0 0.0 0.0
2014-1 487897.0 181.0 0.0 0.0 0.0 0.0
2014-2 470025.0 153.0 0.0 0.0 0.0 0.0
2015-02 88232.0 28.0 0.0 0.0 0.0 0.0
2015-01 65339.0 31.0 0.0 0.0 0.0 0.0
2015-03 101484.0 31.0 0.0 0.0 0.0 0.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2012-1 DRILLING FLUID WASTE 700.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2012-1 DRILLING FLUID WASTE 4.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2012-2 DRILL CUTTINGS 436.4 Tons LANDFILL 100419 ADVANCED DISPOSAL SERVICE CHESTNUT VALLEY LANDFILL MCCLELLANDTOWN PA
2012-2 DRILLING FLUID WASTE 55.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2012-2 FRACING FLUID WASTE 701.5 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-1 FRACING FLUID WASTE 16.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2013-1 FRACING FLUID WASTE 881.5 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-1 PRODUCED FLUID 325.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2013-1 PRODUCED FLUID 410.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-2 FRACING FLUID WASTE 50.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-2 PRODUCED FLUID 1.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2013-2 PRODUCED FLUID 54.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-1 PRODUCED FLUID 964.5 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-2 PRODUCED FLUID 1.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-2 PRODUCED FLUID 35.0 Bbl INJECTION DISPOSAL WELL 34-121-23995 WARREN DRILLING CO #1 (SWIW #6) DEXTER CITY OH

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
2067423 2012-05-11 No Violations Noted HIGHLANDS RIG 9 DRILLING FOR CHEVRON.LOST TOOLS IN HOLE CEMENTING KICK PLUG. CEMENT AND CASING INFO. LOOK GOOD. SITE LOOKED GOOD AT TIME OF INSPECTION.
2074563 2012-05-30 No Violations Noted HIGHLANDS RIG 9 FOR CHEVRON. REDBED ISSUES DRILLING SIDETRACK @ 2284' ON MUD. SITE LOOKED GOOD AT TIME OF INSPECTION.
2186992 2013-06-20 No Violations Noted This well site was inspected concurrently during inspection of the Milesky well pad (Site: 747628 n�e 748631, inspection number 2186892) in response to operator's request for a well site restoration extension. Site appeared to be equipped for production. No erosion or sedimentation issues were noted.
2211069 2013-09-10 No Violations Noted On September 10, 2013, I stopped at Chevronï¾’s Milesky pad for a routine inspection.

There was a good sign out front with all the pertinent Act 9 information. I found an adequate PPC plan in the mailbox as well as an E&S plan Although they are labeled, the wellheads were not tagged according to the regulations; Chevron needs to address this. The site is well-vegetated, but is not restricted and I saw evidence that a herd of cattle had wandered the pad recently. I am concerned that the cowï¾’s hooves may damage the wellhead containment. Because of the vegetation, some of the E&S controls have been removed and this should be noted on the E&S plan. I found good containment around the production tanks and the road appeared in good shape.

For data sources see[3]

References