X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-059-25857"

m
m
 
(3 intermediate revisions by the same user not shown)
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-059-25857
 
| Well ID: 37-059-25857
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.83825, -80.050544 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 39.838250, -80.050544 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Greene County, Pennsylvania|Greene]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Greene Township, Greene County, Pennsylvania|Greene Township]]
+
| State: Pennsylvania
 +
|-
 +
| County: [[Greene_County,_Pennsylvania|Greene]]
 +
|-
 +
| Municipality: [[Greene Township,_Greene_County,_Pennsylvania|Greene Township]]
 
|-
 
|-
 
| Operator Name: [[CHEVRON APPALACHIA LLC]]
 
| Operator Name: [[CHEVRON APPALACHIA LLC]]
 
|-
 
|-
| Well Pad ID: [[144874|144874]]
+
| Well Pad ID: [[144874]]
 
|-
 
|-
| Farm/Lease Name: NIED UNIT 2H
+
| Farm/Lease Name: NIED UNIT
 
|-
 
|-
| First Permit Date: 2011-10-07
+
| License Status: Active
 
|-
 
|-
| Last Permit Date: 2013-02-13
+
| Spud Date: 2012-09-22
 
|-
 
|-
| Spud Date: 2012-09-21
+
| Permit Date: 2011-10-07
 
|-
 
|-
| Unconventional: Yes
+
| Well Type: GAS
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Well Status: ACTIVE
+
| Configuration: Horizontal Well
 
|-
 
|-
| Violations: 0
+
| Conservation: Yes
 
|-
 
|-
| Latitude: 39.83825
+
| Latitude: 39.838250
 
|-
 
|-
 
| Longitude: -80.050544
 
| Longitude: -80.050544
|-
 
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Date
!scope="col" | GAS QUANTITY
+
!scope="col" | Event
!scope="col" | GAS PRODUCTION DAYS
 
!scope="col" | CONDENSATE QUANTITY
 
!scope="col" | CONDENSATE PRODUCTION DAYS
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 2011-2
+
| 2011-10-07
| style="text-align:right;" | 0.0
+
| New Permit Application
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2012-09-21
 +
| Performed Spud Operation
 
|-
 
|-
| 2012-1
+
| 2013-02-13
| style="text-align:right;" | 0.0
+
| New Permit Application
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2013-08-10
 +
| Drilling Completion
 
|-
 
|-
| 2012-2
+
| 2014-02-10
| style="text-align:right;" | 0.0
+
| Perforation
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2014-02-10
 +
| Performed Stimulation 
 
|-
 
|-
| 2013-1
+
| 2016-02-01
| style="text-align:right;" | 0.0
+
| DEVIATED
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2020-01-21
 +
| Newly Drilled
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|}-->
 +
 +
== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 
|-
 
|-
| 2013-2
+
| 2014-02-10
| style="text-align:right;" | 0.0
+
| style="text-align: right;" |  
| style="text-align:right;" | 0.0
+
 
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Completion Reports - Stimulations
 +
| publisher = Pennsylvania Department of Conservation and Natural Resources
 +
| date = 2020-03-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-03-02 }}</ref>
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2014-1
+
| 2011
| style="text-align:right;" | 0.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2014-2
+
| 2013
| style="text-align:right;" | 650777.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 128.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 156.67
+
| style="text-align: right;" | 0
| style="text-align:right;" | 128.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 650,777.00
 +
| style="text-align: right;" | 128
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 156.67
 +
| style="text-align: right;" | 128
 
|-
 
|-
| 2015-02
+
| 2015
| style="text-align:right;" | 108363.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 28.0
+
| style="text-align: right;" | 1,167,523.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2016
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 812,589.00
 +
| style="text-align: right;" | 366
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2015-01
+
| 2017
| style="text-align:right;" | 129937.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 638,165.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2018
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 535,082.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2015-03
+
| 2019
| style="text-align:right;" | 113821.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 464,669.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =Oil and Gas Production Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Operator
!scope="col" | QUANTITY
+
!scope="col" | Waste Type
!scope="col" | UNITS
+
!scope="col" | Quantity
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Disposal Method
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-2
+
| 2012
| DRILL CUTTINGS
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 833.99
+
| Drill Cuttings
| Tons
+
| style="text-align: right;" | 833.99 Tons
 
| LANDFILL
 
| LANDFILL
 
| 100419
 
| 100419
| ADVANCED DISPOSAL SERVICE CHESTNUT VALLEY LANDFILL
 
| MCCLELLANDTOWN
 
| PA
 
 
|-
 
|-
 +
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 67.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2012-2
+
| 2012
| DRILLING FLUID WASTE
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 1.0
+
| Drilling Fluid Waste
| Bbl
+
| style="text-align: right;" | 1,416.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW001
 
| WMGR123SW001
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Drilling Fluid Waste
 +
| style="text-align: right;" | 260.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 
|-
 
|-
| 2012-2
+
| 2013
| FRACING FLUID WASTE
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 67.0
+
| Drill Cuttings
| Bbl
+
| style="text-align: right;" | 600.45 Tons
| REUSE OTHER THAN ROAD SPREADING
 
|
 
| REUSE FOR DRILLING OR PLUGGING
 
|
 
|
 
|-
 
|-
 
| 2013-1
 
| DRILL CUTTINGS
 
| style="text-align:right;" | 25.38
 
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 100419
 
| 100419
| ADVANCED DISPOSAL SERVICE CHESTNUT VALLEY LANDFILL
 
| MCCLELLANDTOWN
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 8,177.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 
|-
 
|-
| 2013-2
+
| 2014
| DRILL CUTTINGS
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 575.07
+
| Fracturing Fluid Waste
| Tons
+
| style="text-align: right;" | 17.18 Tons
 
| LANDFILL
 
| LANDFILL
| 100419
+
| 100592
| ADVANCED DISPOSAL SERVICE CHESTNUT VALLEY LANDFILL
 
| MCCLELLANDTOWN
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 156.67 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-121-23995
 
|-
 
|-
| 2013-2
+
| 2014
| DRILLING FLUID WASTE
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 260.0
+
| Fracturing Fluid Waste
| Bbl
+
| style="text-align: right;" | 0.03 Tons
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
| STORAGE PENDING DISPOSAL OR REUSE
| WMGR123SW001
+
| MID0209062814
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracturing Fluid Waste
 +
| style="text-align: right;" | 26.93 Tons
 +
| LANDFILL
 +
| 100172
 
|-
 
|-
| 2014-1
+
| 2014
| FRACING FLUID WASTE
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 721.67
+
| Fracing Fluid Waste
| Bbl
+
| style="text-align: right;" | 31,132.34 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 5,235.67 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2015
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 66.67 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2015
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 93.33 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-121-23995
 
|-
 
|-
| 2014-1
+
| 2015
| FRACING FLUID WASTE
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 888.33
+
| Fracing Fluid Waste
| Bbl
+
| style="text-align: right;" | 2,822.00 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123SW001
 
| WMGR123SW001
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
|-
 
|-
 
| 2014-2
 
| FLOWBACK FRACTURING SAND
 
| style="text-align:right;" | 26.93
 
| Tons
 
| LANDFILL
 
| 100172
 
| ARDEN LANDFILL
 
| WASHINGTON
 
| PA
 
 
|-
 
|-
 +
| 2015
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 8,032.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2014-2
+
| 2015
| FLOWBACK FRACTURING SAND
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 0.03
+
| Fracturing Fluid Waste
| Tons
+
| style="text-align: right;" | 82.97 Tons
 
| STORAGE PENDING DISPOSAL OR REUSE
 
| STORAGE PENDING DISPOSAL OR REUSE
 
| MID0209062814
 
| MID0209062814
| NORTHERN A-1 SERVICES
 
| KALKASKA
 
| MI
 
 
|-
 
|-
 +
| 2016
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 43.34 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-059-24202
 
|-
 
|-
| 2014-2
+
| 2016
| FLOWBACK FRACTURING SAND
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 17.18
+
| Produced Fluid
| Tons
+
| style="text-align: right;" | 1,673.64 Bbl
| LANDFILL
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| 100592
+
| WMGR123SW019
| SOUTH HILLS LANDFILL
 
| SOUTH HILLS
 
| PA
 
 
|-
 
|-
|-
+
| 2016
| 2014-2
+
| [[CHEVRON APPALACHIA LLC]]
| FRACING FLUID WASTE
+
| Produced Fluid
| style="text-align:right;" | 30.0
+
| style="text-align: right;" | 2,489.12 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2017
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 655.04 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2017
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 350.77 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 +
|-
 +
| 2017
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 2,321.66 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 30.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-059-24202
 +
|-
 +
| 2017
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 208.33 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-157-25511
 
|-
 
|-
| 2014-2
+
| 2018
| FRACING FLUID WASTE
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 7.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 392.33 Bbl
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
| REUSE (AT WELL PAD)
| WMGR123SW001
+
|  
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2018
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 54.83 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 
|-
 
|-
| 2014-2
+
| 2018
| PRODUCED FLUID
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 5.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 665.66 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
|
 
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
 
 
|  
 
|  
 +
|-
 +
| 2018
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 75.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2019
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 40.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
 +
| 2019
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 80.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 
|-
 
|-
| 2014-2
+
| 2019
| PRODUCED FLUID
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 156.67
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 853.33 Bbl
| INJECTION DISPOSAL WELL
+
| REUSE (AT WELL PAD)
| 34-121-23995
+
|  
| WARREN DRILLING CO #1 (SWIW #6)
 
| DEXTER CITY
 
| OH
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-26 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| 2112723
 
| 2112723
 +
| Primary Facility
 
| 2012-10-31
 
| 2012-10-31
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| CROWN RIG 5 DRILLING FOR CHEVRON. TOP HOLE COMPLETE. SITE LOOKED GOOD AT TIME OF INSPECTION.
 
| CROWN RIG 5 DRILLING FOR CHEVRON. TOP HOLE COMPLETE. SITE LOOKED GOOD AT TIME OF INSPECTION.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2125875
 
| 2125875
 +
| Primary Facility
 
| 2012-12-21
 
| 2012-12-21
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| TOP HOLE DRILLING COMPLETE. SITE COMPLIANT AT TIME OF INSPECTION.
 
| TOP HOLE DRILLING COMPLETE. SITE COMPLIANT AT TIME OF INSPECTION.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2195693
 
| 2195693
 +
| Primary Facility
 
| 2013-08-07
 
| 2013-08-07
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| Patterson 339 drilling for Chevron. Were drilling lateral at 12063' at time of inspection.
 
| Patterson 339 drilling for Chevron. Were drilling lateral at 12063' at time of inspection.
 +
|-
 +
| 2262082
 +
| Primary Facility
 +
| 2014-04-14
 +
| Administrative/File Review
 +
| In Compliance with Policy
 +
| SPILL.  Apx. 8 barrels of frac fluid released onto secondary containment.  Currently vacuuming material for disposal.
 +
|-
 +
| 2268709
 +
| Primary Facility
 +
| 2014-04-14
 +
| Incident- Response to Accident or Event
 +
| In Compliance with Policy
 +
| Spill
 +
|-
 +
| 2285005
 +
| Primary Facility
 +
| 2014-06-11
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Well in compliance
 +
|-
 +
| 2294337
 +
| Primary Facility
 +
| 2014-07-30
 +
| Routine/Complete Inspection
 +
| Violation(s) Noted
 +
| CHEVRON HAD RECENTLY FRACKED THIS WELL AND HAS GAS COMING TO SURFACE BETWEEN THERE 8-5/8 AND 11-3/4 CASING SETS. CHEVRONS CONTRACTOR WAS ON SITE TO INSTALL A PACK OFF ON THE 8-5/8 CASING AT SURFACE. THEY WILL THEN PLUMB A 1" LINE INTO THERE PRODUTION TANK AND INSTALL A VALVE AND GAUGE IN LINE FOR MONITORING SURFACE GAS PRESSURES. I SCHEDULED A FOLLOW UP VISIT TO CONFIRM PACK OFF IS FUNCTIONAL
 +
|-
 +
| 2294431
 +
| Primary Facility
 +
| 2014-08-05
 +
| Compliance Evaluation
 +
| No Violations Noted
 +
| FOLLOW UP VISIT FROM 7/30/2014 IN REGARDS TO SURFACE GAS FROM WELL. PACK OFF IN PLACE. MONITORING GAUGE HAD A READING OF 75 PSI. SURFACE GAS PLUMBED INTO PRODUCTION TANK AND  APPEARED TO BE FUNCTIONAL BY OPENING RELIEF VALVE.
 +
|-
 +
| 2309450
 +
| Primary Facility
 +
| 2014-07-31
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| he well casing near the surface of the ground continues to leak gas, but the operator was in process of installing a casing plug on the well during the inspection.
 +
|-
 +
| 2318456
 +
| Primary Facility
 +
| 2014-09-04
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Wells being flowed back to put the well in production.
 +
|-
 +
| 2564877
 +
| Primary Facility
 +
| 2017-02-24
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The Act 9 sign was in place and required documentation was present. After a phone conversation with Chevron it was determined that the Department had issued a major modification approval in October 2016. It is recommended that a new E&S plan and major modification approval letter be place in the mail box. The equipment appeared to be in good condition. The site was well vegetated and Chevron indicated restoration of the site is planned for 2017. There were no signs of erosion observed at the time of inspection nor were violations observed.
 +
|-
 +
|}
 +
==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
| 2294337
 +
| 702417
 +
| 07/30/2014
 +
| 2014-07-30
 +
| 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days
 +
| Administrative
 +
|
 +
|-
 +
|}
 +
==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
| 702417
 +
| 314051
 +
| NOV - Notice of Violation
 
|  
 
|  
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =Oil and Gas Compliance Report
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-05-20
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]

Latest revision as of 21:25, 14 May 2020

Well Details

Well ID: 37-059-25857
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Greene Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 144874
Farm/Lease Name: NIED UNIT
License Status: Active
Spud Date: 2012-09-22
Permit Date: 2011-10-07
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.838250
Longitude: -80.050544

For data sources see[1][2][3]

Well History

Date Event
2011-10-07 New Permit Application
2012-09-21 Performed Spud Operation
2013-02-13 New Permit Application
2013-08-10 Drilling Completion
2014-02-10 Perforation
2014-02-10 Performed Stimulation
2016-02-01 DEVIATED
2020-01-21 Newly Drilled

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-02-10 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 650,777.00 128 0.00 0 156.67 128
2015 CHEVRON APPALACHIA LLC 1,167,523.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 812,589.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 638,165.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 535,082.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 464,669.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Drill Cuttings 833.99 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 67.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 1,416.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste 260.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Drill Cuttings 600.45 Tons LANDFILL 100419
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 8,177.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 17.18 Tons LANDFILL 100592
2014 CHEVRON APPALACHIA LLC Produced Fluid 156.67 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 0.03 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 26.93 Tons LANDFILL 100172
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 31,132.34 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid 5,235.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Fracing Fluid Waste 66.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 93.33 Bbl INJECTION DISPOSAL WELL 34-121-23995
2015 CHEVRON APPALACHIA LLC Fracing Fluid Waste 2,822.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 CHEVRON APPALACHIA LLC Produced Fluid 8,032.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 82.97 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2016 CHEVRON APPALACHIA LLC Produced Fluid 43.34 Bbl INJECTION DISPOSAL WELL 34-059-24202
2016 CHEVRON APPALACHIA LLC Produced Fluid 1,673.64 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 2,489.12 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 655.04 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 350.77 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 2,321.66 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Produced Fluid 30.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2017 CHEVRON APPALACHIA LLC Produced Fluid 208.33 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018 CHEVRON APPALACHIA LLC Produced Fluid 392.33 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 54.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 665.66 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 75.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 40.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 80.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 853.33 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2112723 Primary Facility 2012-10-31 Drilling/Alteration No Violations Noted CROWN RIG 5 DRILLING FOR CHEVRON. TOP HOLE COMPLETE. SITE LOOKED GOOD AT TIME OF INSPECTION.
2125875 Primary Facility 2012-12-21 Drilling/Alteration No Violations Noted TOP HOLE DRILLING COMPLETE. SITE COMPLIANT AT TIME OF INSPECTION.
2195693 Primary Facility 2013-08-07 Drilling/Alteration No Violations Noted Patterson 339 drilling for Chevron. Were drilling lateral at 12063' at time of inspection.
2262082 Primary Facility 2014-04-14 Administrative/File Review In Compliance with Policy SPILL. Apx. 8 barrels of frac fluid released onto secondary containment. Currently vacuuming material for disposal.
2268709 Primary Facility 2014-04-14 Incident- Response to Accident or Event In Compliance with Policy Spill
2285005 Primary Facility 2014-06-11 Routine/Complete Inspection No Violations Noted Well in compliance
2294337 Primary Facility 2014-07-30 Routine/Complete Inspection Violation(s) Noted CHEVRON HAD RECENTLY FRACKED THIS WELL AND HAS GAS COMING TO SURFACE BETWEEN THERE 8-5/8 AND 11-3/4 CASING SETS. CHEVRONS CONTRACTOR WAS ON SITE TO INSTALL A PACK OFF ON THE 8-5/8 CASING AT SURFACE. THEY WILL THEN PLUMB A 1" LINE INTO THERE PRODUTION TANK AND INSTALL A VALVE AND GAUGE IN LINE FOR MONITORING SURFACE GAS PRESSURES. I SCHEDULED A FOLLOW UP VISIT TO CONFIRM PACK OFF IS FUNCTIONAL
2294431 Primary Facility 2014-08-05 Compliance Evaluation No Violations Noted FOLLOW UP VISIT FROM 7/30/2014 IN REGARDS TO SURFACE GAS FROM WELL. PACK OFF IN PLACE. MONITORING GAUGE HAD A READING OF 75 PSI. SURFACE GAS PLUMBED INTO PRODUCTION TANK AND APPEARED TO BE FUNCTIONAL BY OPENING RELIEF VALVE.
2309450 Primary Facility 2014-07-31 Routine/Complete Inspection No Violations Noted he well casing near the surface of the ground continues to leak gas, but the operator was in process of installing a casing plug on the well during the inspection.
2318456 Primary Facility 2014-09-04 Routine/Complete Inspection No Violations Noted Wells being flowed back to put the well in production.
2564877 Primary Facility 2017-02-24 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and required documentation was present. After a phone conversation with Chevron it was determined that the Department had issued a major modification approval in October 2016. It is recommended that a new E&S plan and major modification approval letter be place in the mail box. The equipment appeared to be in good condition. The site was well vegetated and Chevron indicated restoration of the site is planned for 2017. There were no signs of erosion observed at the time of inspection nor were violations observed.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2294337 702417 07/30/2014 2014-07-30 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
702417 314051 NOV - Notice of Violation

For data sources see[8]