X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-059-25687"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-059-25687
 
| Well ID: 37-059-25687
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.921961, -80.218236 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 39.921961, -80.218236 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Greene County, Pennsylvania|Greene]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Franklin Township, Greene County, Pennsylvania|Franklin Township]]
+
| State: Pennsylvania
 +
|-
 +
| County: [[Greene_County,_Pennsylvania|Greene]]
 +
|-
 +
| Municipality: [[Franklin Township,_Greene_County,_Pennsylvania|Franklin Township]]
 
|-
 
|-
 
| Operator Name: [[CHEVRON APPALACHIA LLC]]
 
| Operator Name: [[CHEVRON APPALACHIA LLC]]
 
|-
 
|-
| Well Pad ID: [[148450|148450]]
+
| Well Pad ID: [[148450]]
 
|-
 
|-
 
| Farm/Lease Name: GROOMS UNIT 9H
 
| Farm/Lease Name: GROOMS UNIT 9H
 
|-
 
|-
| First Permit Date: 2011-03-14
+
| License Status: Active
|-
 
| Last Permit Date: 2011-03-14
 
 
|-
 
|-
| Spud Date: 2011-08-28
+
| Spud Date: 08/28/2011
 
|-
 
|-
| Unconventional: Yes
+
| Permit Date: 3/14/2011
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Well Status: ACTIVE
+
| Configuration: Horizontal Well
|-
 
| Violations: 0
 
 
|-
 
|-
 
| Latitude: 39.921961
 
| Latitude: 39.921961
 
|-
 
|-
 
| Longitude: -80.218236
 
| Longitude: -80.218236
|-
 
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2011-1
+
| 2011
| style="text-align:right;" | 0.0
+
| [[ATLAS RESOURCES LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-1
+
| 2013
| style="text-align:right;" | 0.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 1,490,081.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 777,181.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 133.76
 +
| style="text-align: right;" | 184
 
|-
 
|-
| 2011-2
+
| 2015
| style="text-align:right;" | 0.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 570,798.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2016
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 452,278.00
 +
| style="text-align: right;" | 366
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-2
+
| 2017
| style="text-align:right;" | 0.0
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 323,929.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2018
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 239,631.00
 +
| style="text-align: right;" | 273
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2019
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| style="text-align: right;" | 84,845.00
 +
| style="text-align: right;" | 90
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Waste Type
 +
!scope="col" | Quantity
 +
!scope="col" | Disposal Method
 +
!scope="col" | Waste Facility ID
 
|-
 
|-
 
| 2012-1
 
| 2012-1
| style="text-align:right;" | 0.0
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 1,760.00 Bbl
| style="text-align:right;" | 0.0
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| style="text-align:right;" | 0.0
+
| WMGR123SW001
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2012-2
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 1,170.02 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123SW001
 
|-
 
|-
 
| 2012-2
 
| 2012-2
| style="text-align:right;" | 0.0
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 3,120.15 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
+
|-
| style="text-align:right;" | 0.0
+
| 2013-1
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 17.50 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123SW001
 
|-
 
|-
 +
| 2013-1
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 1,835.63 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| style="text-align:right;" | 828412.0
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 1,233.00 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2013-2
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 536.25 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 
|-
 
|-
 
| 2013-2
 
| 2013-2
| style="text-align:right;" | 661669.0
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 184.0
+
| style="text-align: right;" | 2,182.75 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2013-2
 +
| Fracturing Fluid Waste (in Tons)
 +
| style="text-align: right;" | 27.71 Tons
 +
| LANDFILL
 +
| 073 114 654
 +
|-
 +
| 2013-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 339.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| style="text-align:right;" | 403396.0
+
| Fracturing Fluid Waste (in Tons)
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 2.22 Tons
| style="text-align:right;" | 0.0
+
| LANDFILL
| style="text-align:right;" | 0.0
+
| 100172
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2014-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 8.75 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-121-23995
 
|-
 
|-
| 2014-2
+
| 2014-1
| style="text-align:right;" | 373785.0
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 184.0
+
| style="text-align: right;" | 257.00 Bbl
| style="text-align:right;" | 133.76
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| style="text-align:right;" | 184.0
+
| WMGR123SW001
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2014-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 973.25 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2015-02
+
| 2014-2
| style="text-align:right;" | 43888.0
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 28.0
+
| style="text-align: right;" | 15.00 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-121-23995
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2014-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 133.75 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 
|-
 
|-
| 2015-01
+
| 2014-2
| style="text-align:right;" | 55732.0
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 616.50 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 680.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2015-03
+
| 2015-2
| style="text-align:right;" | 53397.0
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 618.75 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
|}
+
| 2016-1
For data sources see<ref>{{cite web
+
| Produced Fluid (in Barrels) RWC 802
| title = Oil and Gas Historical Production Report
+
| style="text-align: right;" | 666.19 Bbl
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| REUSE OTHER THAN ROAD SPREADING
| date = 2015-05-26
+
|  
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
 
| accessdate = 2015-05-27 }}</ref>
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | PERIOD
 
!scope="col" | TYPE
 
!scope="col" | QUANTITY
 
!scope="col" | UNITS
 
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-1
+
| 2016-2
| DRILLING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 444.13 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| WMGR123SW001
+
| WMGR123SW019
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
|-
+
| 2016-2
| 2012-2
+
| Produced Fluid (in Barrels) RWC 802
| FRACING FLUID WASTE
+
| style="text-align: right;" | 90.38 Bbl
| style="text-align:right;" | 3.0
 
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR DRILLING OR PLUGGING
 
|
 
|
 
 
|-
 
|-
 +
| 2017-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 75.93 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2017-01
 +
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811
 +
| style="text-align: right;" | 0.03 Tons
 +
| RESIDUAL WASTE TRANSFER FACILITY
 +
| 101532
 
|-
 
|-
| 2012-2
+
| 2017-02
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 62.93 Bbl
| Bbl
+
| RESIDUAL WASTE PROCESSING FACILITY
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| WMGR123SW019
| WMGR123SW001
 
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 30.08 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 
|-
 
|-
| 2013-1
+
| 2017-03
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 30.63 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE FOR DRILLING OR PLUGGING
+
|-
 +
| 2017-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.63 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 577.50 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 43.75 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-157-25511
 
|-
 
|-
| 2013-1
+
| 2017-06
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 17.5
+
| style="text-align: right;" | 15.00 Bbl
| Bbl
+
| RESIDUAL WASTE PROCESSING FACILITY
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| WMGR123SW019
| WMGR123SW001
 
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
|-
+
| 2017-06
| 2013-1
+
| Produced Fluid (in Barrels) RWC 802
| PRODUCED FLUID
+
| style="text-align: right;" | 15.00 Bbl
| style="text-align:right;" | 1.0
+
| REUSE (AT WELL PAD)
| Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
| REUSE FOR DRILLING OR PLUGGING
 
|
 
 
|  
 
|  
 
|-
 
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.75 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 
|-
 
|-
| 2013-2
+
| 2017-08
| FLOWBACK FRACTURING SAND
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 27.71
+
| style="text-align: right;" | 11.25 Bbl
| Tons
+
| INJECTION DISPOSAL WELL
| LANDFILL
+
| 34-157-25511
| 073 114 654
 
| US ECOLOGY IDAHO, INC.
 
| GRAND VIEW
 
| ID
 
 
|-
 
|-
 +
| 2017-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 
|-
 
|-
| 2013-2
+
| 2017-08
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 2.0
+
| style="text-align: right;" | 12.50 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2017-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 27.50 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.75 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 27.50 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2013-2
+
| 2017-10
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 536.25
+
| style="text-align: right;" | 41.25 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
|  
| WMGR123SW001
 
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.16 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 
|-
 
|-
| 2013-2
+
| 2017-11
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 339.0
+
| style="text-align: right;" | 39.38 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28776
 +
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 41.75 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 42.50 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.13 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 2014-1
+
| 2018-03
| FLOWBACK FRACTURING SAND
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 2.22
+
| style="text-align: right;" | 26.88 Bbl
| Tons
+
| RESIDUAL WASTE PROCESSING FACILITY
| LANDFILL
+
| WMGR123SW005
| 100172
 
| ARDEN LANDFILL
 
| WASHINGTON
 
| PA
 
 
|-
 
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.75 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-1
+
| 2018-03
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 973.25
+
| style="text-align: right;" | 14.13 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.75 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 54.38 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 27.50 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 55.63 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-1
+
| 2018-07
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 257.0
+
| style="text-align: right;" | 28.13 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
|  
| WMGR123SW001
 
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.75 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 2014-1
+
| 2018-08
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 8.75
+
| style="text-align: right;" | 67.50 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| INJECTION DISPOSAL WELL
+
|  
| 34-121-23995
 
| WARREN DRILLING CO #1 (SWIW #6)
 
| DEXTER CITY
 
| OH
 
 
|-
 
|-
 +
| 2018-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 40.63 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 2014-2
+
| 2018-11
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 616.5
+
| style="text-align: right;" | 54.38 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 12.50 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 81.88 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
 +
| 2019-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 87.50 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-2
+
| 2019-02
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 133.75
+
| style="text-align: right;" | 57.50 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
|  
| WMGR123SW001
 
| RONCO WASTE PROCESSING FACILITY
 
| MASONTOWN
 
| PA
 
 
|-
 
|-
|-
+
| 2019-03
| 2014-2
+
| Produced Fluid (in Barrels) RWC 802
| PRODUCED FLUID
+
| style="text-align: right;" | 43.75 Bbl
| style="text-align:right;" | 15.0
+
| REUSE (AT WELL PAD)
| Bbl
+
|  
| INJECTION DISPOSAL WELL
 
| 34-121-23995
 
| WARREN DRILLING CO #1 (SWIW #6)
 
| DEXTER CITY
 
| OH
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-26 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| 2006244
 
| 2006244
| 2011-09-21
+
| Primary Facility
 +
| 09/21/2011
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| CONDUCTOR IS SET AT 100'. NO OTHER DRILLING.
 
| CONDUCTOR IS SET AT 100'. NO OTHER DRILLING.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2027571
 
| 2027571
| 2011-09-13
+
| Primary Facility
 +
| 09/13/2011
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| The Department was at the above referenced Marcellus Well to conduct a Routine Inspection.  The operator is finishing up construction of the pad and lining the pits.  The Department reviewed the E/S Plan on site.  The E/S controls appear to be in good condition.  The Operator is currently adding E/S controls to make sure all the sediment stays on site.  Temporary stabilization has been obtained on this site.  Grass is beginning to grow on the fill slopes.
 
| The Department was at the above referenced Marcellus Well to conduct a Routine Inspection.  The operator is finishing up construction of the pad and lining the pits.  The Department reviewed the E/S Plan on site.  The E/S controls appear to be in good condition.  The Operator is currently adding E/S controls to make sure all the sediment stays on site.  Temporary stabilization has been obtained on this site.  Grass is beginning to grow on the fill slopes.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2035020
 
| 2035020
| 2012-01-09
+
| Primary Facility
 +
| 01/09/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| WELL DRILLED TO KOP. WILL BE COMPLETED WITH A BIGGER RIG.
 
| WELL DRILLED TO KOP. WILL BE COMPLETED WITH A BIGGER RIG.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2051389
 
| 2051389
| 2012-03-13
+
| Primary Facility
 +
| 03/13/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| Patterson 334 drilling for Chevron.Rig had just skidded over getting ready to start driling Grooms 9-H.Site in good condition.
 
| Patterson 334 drilling for Chevron.Rig had just skidded over getting ready to start driling Grooms 9-H.Site in good condition.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2051462
 
| 2051462
| 2012-03-13
+
| Primary Facility
 +
| 03/13/2012
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2108321
 
| 2108321
| 2012-09-25
+
| Primary Facility
 +
| 09/25/2012
 +
| Administrative/File Review
 
| In Compliance with Policy
 
| In Compliance with Policy
 
| The Department received a spill notification from the Operator on 9/25/12.  50 gallons of re-use water was spilled to the ground on secondary containment.  The Operator vacuumed up the re-use water and disposed.  The Department did not conduct a site inspection.  The Operator is in compliance with the spill policy.
 
| The Department received a spill notification from the Operator on 9/25/12.  50 gallons of re-use water was spilled to the ground on secondary containment.  The Operator vacuumed up the re-use water and disposed.  The Department did not conduct a site inspection.  The Operator is in compliance with the spill policy.
 +
|-
 +
| 2449064
 +
| Primary Facility
 +
| 2016-01-09
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
| On 01/09/16 at approximately 0800 hours I conducted a routine partial inspection of the Grooms Unit. The Act 9 sign was in place and all required documents were present at the site. I met with Nick Staffieri of Chevron to discuss changes at the site.
 +
 +
One of the forebays on the site (#3) was moved within the same drainage area as proposed, but without Departmental approval. This is a violation of 102.5(m)(4). It is recommended that Chevron submit for a minor modification to reflect current conditions at the site.
 +
|-
 +
| 2636961
 +
| Primary Facility
 +
| 2017-09-15
 +
| Site Restoration
 +
| No Violations Noted
 +
| A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and meets and exceeds 70% uniform vegetative cover. There were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. The site meets the requirements for permit termination. The NOT is approved.
 +
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 09/21/2012
 +
| 09/21/2012
 +
| style="text-align: right;" | 6491.00
 +
| style="text-align: right;" | 4,307,696.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="13"| 1
 +
| rowspan="2"| GBW-30 BREAKER
 +
| rowspan="2"| Halliburton Energy Services
 +
| rowspan="2"| Gel Breaker
 +
| Hemicellulase enzyme
 +
| 9012-54-8
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.00001000
 +
| style="text-align: right;" |
 +
|-
 +
| Carbohydrates
 +
|
 +
| style="text-align: right;" | 95.00
 +
| style="text-align: right;" | 0.00009000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| WG-36 GELLING AGENT
 +
| rowspan="1"| Halliburton Energy Services
 +
| rowspan="1"| Water Viscosifier
 +
| Guar gum
 +
| 9000-30-0
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00303000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| FR-66 Friction Reducer
 +
| rowspan="1"| Halliburton Energy Services
 +
| rowspan="1"| Friction Reducer
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| ASP 900
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Friction Reducer
 +
| Ammonium sulfate
 +
| 7783-20-2
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="3"| Biocide EC 6116A
 +
| rowspan="3"| Nalco
 +
| rowspan="3"| Biocide
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00748000
 +
| style="text-align: right;" |
 +
|-
 +
| Dibromoacetonitrile
 +
| 3252-43-5
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00125000
 +
| style="text-align: right;" |
 +
|-
 +
| Polyethylene glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Proppant (lbs)
 +
| rowspan="1"|
 +
| rowspan="1"| Proppant
 
|  
 
|  
 +
|
 +
| style="text-align: right;" | 8.71
 +
| style="text-align: right;" | 9.62
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Clean Volume (gals)
 +
| rowspan="1"|
 +
| rowspan="1"| Carrier/Base Fluid
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" | 91.29
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| EC6673W
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Iron Control
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00688000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| 7.5 Hcl Acid
 +
| rowspan="1"|
 +
| rowspan="1"| Used to open perfs
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 7.50
 +
| style="text-align: right;" | 0.30
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| EC6486A
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Scale Inhibitor
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00740000
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
==References==
== References ==
+
<references/>
{{reflist}}
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 16:20, 13 July 2019

Well Details

Well ID: 37-059-25687
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Franklin Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148450
Farm/Lease Name: GROOMS UNIT 9H
License Status: Active
Spud Date: 08/28/2011
Permit Date: 3/14/2011
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 39.921961
Longitude: -80.218236

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 1,490,081.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 777,181.00 365 0.00 0 133.76 184
2015 CHEVRON APPALACHIA LLC 570,798.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 452,278.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 323,929.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 239,631.00 273 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 84,845.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-1 Drilling Fluid Waste (in Barrels) 1,760.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012-2 Fracing Fluid Waste (in Barrels) 1,170.02 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012-2 Fracing Fluid Waste (in Barrels) 3,120.15 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Fracing Fluid Waste (in Barrels) 17.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013-1 Fracing Fluid Waste (in Barrels) 1,835.63 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Produced Fluid (in Barrels) 1,233.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Fracing Fluid Waste (in Barrels) 536.25 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013-2 Fracing Fluid Waste (in Barrels) 2,182.75 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Fracturing Fluid Waste (in Tons) 27.71 Tons LANDFILL 073 114 654
2013-2 Produced Fluid (in Barrels) 339.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Fracturing Fluid Waste (in Tons) 2.22 Tons LANDFILL 100172
2014-1 Produced Fluid (in Barrels) 8.75 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014-1 Produced Fluid (in Barrels) 257.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014-1 Produced Fluid (in Barrels) 973.25 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 15.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014-2 Produced Fluid (in Barrels) 133.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014-2 Produced Fluid (in Barrels) 616.50 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 680.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 618.75 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 666.19 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Produced Fluid (in Barrels) RWC 802 444.13 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-2 Produced Fluid (in Barrels) RWC 802 90.38 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Produced Fluid (in Barrels) RWC 802 75.93 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-01 Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 0.03 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017-02 Produced Fluid (in Barrels) RWC 802 62.93 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-03 Produced Fluid (in Barrels) RWC 802 30.08 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-03 Produced Fluid (in Barrels) RWC 802 30.63 Bbl REUSE (AT WELL PAD)
2017-04 Produced Fluid (in Barrels) RWC 802 15.63 Bbl REUSE (AT WELL PAD)
2017-05 Produced Fluid (in Barrels) RWC 802 577.50 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 43.75 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017-06 Produced Fluid (in Barrels) RWC 802 15.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-06 Produced Fluid (in Barrels) RWC 802 15.00 Bbl REUSE (AT WELL PAD)
2017-07 Produced Fluid (in Barrels) RWC 802 13.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-08 Produced Fluid (in Barrels) RWC 802 11.25 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017-08 Produced Fluid (in Barrels) RWC 802 13.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-08 Produced Fluid (in Barrels) RWC 802 12.50 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 13.75 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-10 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 41.25 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-11 Produced Fluid (in Barrels) RWC 802 13.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-11 Produced Fluid (in Barrels) RWC 802 39.38 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-12 Produced Fluid (in Barrels) RWC 802 15.00 Bbl INJECTION DISPOSAL WELL 34-119-28776
2017-12 Produced Fluid (in Barrels) RWC 802 41.75 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-02 Produced Fluid (in Barrels) RWC 802 42.50 Bbl REUSE (AT WELL PAD)
2018-02 Produced Fluid (in Barrels) RWC 802 13.13 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-03 Produced Fluid (in Barrels) RWC 802 26.88 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-03 Produced Fluid (in Barrels) RWC 802 13.75 Bbl REUSE (AT WELL PAD)
2018-03 Produced Fluid (in Barrels) RWC 802 14.13 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-04 Produced Fluid (in Barrels) RWC 802 13.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-04 Produced Fluid (in Barrels) RWC 802 54.38 Bbl REUSE (AT WELL PAD)
2018-05 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 55.63 Bbl REUSE (AT WELL PAD)
2018-07 Produced Fluid (in Barrels) RWC 802 28.13 Bbl REUSE (AT WELL PAD)
2018-07 Produced Fluid (in Barrels) RWC 802 13.75 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-08 Produced Fluid (in Barrels) RWC 802 67.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-09 Produced Fluid (in Barrels) RWC 802 40.63 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-11 Produced Fluid (in Barrels) RWC 802 54.38 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-12 Produced Fluid (in Barrels) RWC 802 12.50 Bbl REUSE (AT WELL PAD)
2018-12 Produced Fluid (in Barrels) RWC 802 81.88 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-01 Produced Fluid (in Barrels) RWC 802 87.50 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 57.50 Bbl REUSE (AT WELL PAD)
2019-03 Produced Fluid (in Barrels) RWC 802 43.75 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2006244 Primary Facility 09/21/2011 Drilling/Alteration No Violations Noted CONDUCTOR IS SET AT 100'. NO OTHER DRILLING.
2027571 Primary Facility 09/13/2011 Routine/Complete Inspection No Violations Noted The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The operator is finishing up construction of the pad and lining the pits. The Department reviewed the E/S Plan on site. The E/S controls appear to be in good condition. The Operator is currently adding E/S controls to make sure all the sediment stays on site. Temporary stabilization has been obtained on this site. Grass is beginning to grow on the fill slopes.
2035020 Primary Facility 01/09/2012 Drilling/Alteration No Violations Noted WELL DRILLED TO KOP. WILL BE COMPLETED WITH A BIGGER RIG.
2051389 Primary Facility 03/13/2012 Drilling/Alteration No Violations Noted Patterson 334 drilling for Chevron.Rig had just skidded over getting ready to start driling Grooms 9-H.Site in good condition.
2051462 Primary Facility 03/13/2012 Drilling/Alteration No Violations Noted
2108321 Primary Facility 09/25/2012 Administrative/File Review In Compliance with Policy The Department received a spill notification from the Operator on 9/25/12. 50 gallons of re-use water was spilled to the ground on secondary containment. The Operator vacuumed up the re-use water and disposed. The Department did not conduct a site inspection. The Operator is in compliance with the spill policy.
2449064 Primary Facility 2016-01-09 Routine/Partial Inspection No Violations Noted On 01/09/16 at approximately 0800 hours I conducted a routine partial inspection of the Grooms Unit. The Act 9 sign was in place and all required documents were present at the site. I met with Nick Staffieri of Chevron to discuss changes at the site.

One of the forebays on the site (#3) was moved within the same drainage area as proposed, but without Departmental approval. This is a violation of 102.5(m)(4). It is recommended that Chevron submit for a minor modification to reflect current conditions at the site.

2636961 Primary Facility 2017-09-15 Site Restoration No Violations Noted A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and meets and exceeds 70% uniform vegetative cover. There were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. The site meets the requirements for permit termination. The NOT is approved.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 09/21/2012 09/21/2012 6491.00 4,307,696.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 GBW-30 BREAKER Halliburton Energy Services Gel Breaker Hemicellulase enzyme 9012-54-8 15.00 0.00001000
Carbohydrates 95.00 0.00009000
WG-36 GELLING AGENT Halliburton Energy Services Water Viscosifier Guar gum 9000-30-0 100.00 0.00303000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00
Biocide EC 6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00748000
Dibromoacetonitrile 3252-43-5 5.00 0.00125000
Polyethylene glycol 25322-68-3 60.00 0.01
Proppant (lbs) Proppant 8.71 9.62
Clean Volume (gals) Carrier/Base Fluid 91.29 100.00
EC6673W Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00688000
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.30
EC6486A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00740000

For data sources see[7]

References