37-031-24454

Well Details

Well ID: 37-031-24454
Loading map...
Country: United States
State: Pennsylvania
County: Clarion
Municipality: Toby Township
Operator Name: FREDERICK DRILLING CO & SONS INC
Well Pad ID:
Farm/Lease Name: FERGUSON 4
License Status:
Spud Date:
Permit Date: 2006-08-11
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.055220
Longitude: -79.594990

For data sources see[1][2][3]

Well History

Date Event
2006-08-11 New Permit Application

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 FREDERICK DRILLING CO & SONS INC 191.14 52 0.00 0 0.00 0
2010 FREDERICK DRILLING CO & SONS INC 0.36 365 0.00 0 0.00 0
2011 FREDERICK DRILLING CO & SONS INC 172.14 365 0.00 0 0.00 0
2012 FREDERICK DRILLING CO & SONS INC 0.14 365 0.00 0 0.00 0
2013 FREDERICK DRILLING CO & SONS INC 1.71 365 0.00 0 0.00 0
2014 FREDERICK DRILLING CO & SONS INC 2.00 365 0.00 0 0.00 0
2015 FREDERICK DRILLING CO & SONS INC 35,714.29 365 0.00 0 0.00 0
2016 FREDERICK DRILLING CO & SONS INC 0.71 365 0.00 0 0.00 0
2017 FREDERICK DRILLING CO & SONS INC 0.71 365 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2792409 Primary Facility 2018-08-22 Routine/Partial Inspection No Violations Noted At the time of inspection, well was leaking a significant amount of gas from the outside of the surface casing. Pressure on the well, from a gauge onsite, was reading 170 psi. The valve was open for production and was hooked up to a drip and regulator. The well was properly labeled. Production was reported in 2017.

Please refer to Chapter 78.86 which discusses defective casing or cementing. The Department requests that the leak be taken care of following this regulation.

§ 78.86 Defective casing or cementing In a well that has defective, insufficient or improperly cemented casing, the operator shall report the defect to the Department within 24 hours of discovery by the operator and shall correct the defect. The operator shall correct the defect or submit a plan to correct the defect for approval by the Department within 30 days. If the defect cannot be corrected or an alternate method is not approved by the Department, the well shall be plugged under § § 78.91 - 78.98 (relating to plugging).

2818533 Primary Facility 2018-12-19 Follow-up Inspection No Violations Noted This was a follow up inspection to check on the bubbling that had been occurring from the well. Operator had been notified and a call was received stating that it was fixed. This was confirmed. The well is no longer leaking. The well was producing and a gauge was reading 160 psi.

For data sources see[6]

References