If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-051-24524 | | Well ID: 37-051-24524 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 40.035311, -79.773350 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 10 | + | | Spud Date: 2012-10-27 |
|- | |- | ||
− | | Permit Date: 10 | + | | Permit Date: 2012-10-10 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2013-10-24 | ||
+ | | 2013-10-30 | ||
+ | | style="text-align: right;" | 7649 | ||
+ | | style="text-align: right;" | 3,052,140.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="12"| 1 | ||
+ | | rowspan="1"| FR-66 | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Hydrotreated Light Distillite | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0003469 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Clean Volume | ||
+ | | rowspan="1"| Chevron Applachia, LLC | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | H20 | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 91.45 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| EC 6116a | ||
+ | | rowspan="3"| Nalco | ||
+ | | rowspan="3"| Biocide | ||
+ | | Polyethylene Glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.0001453 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00001210 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 1, 1-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00007270 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Proppant | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Proppant | ||
+ | | Crystalline Silica | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 8.55 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| GBW-30 | ||
+ | | rowspan="2"| Halliburton | ||
+ | | rowspan="2"| Gel Breaker | ||
+ | | Carbohydrates | ||
+ | | 87246-72-8 | ||
+ | | style="text-align: right;" | 95 | ||
+ | | style="text-align: right;" | 0.00000720 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Hemicellulase enzyme | ||
+ | | 9012-54-8 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.00000110 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 15% Hcl Acid | ||
+ | | rowspan="1"| Reagent/PPG | ||
+ | | rowspan="1"| Used to open perfs | ||
+ | | Hydrochloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.0009878 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| EC6673W | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Iron Control | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00006870 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| WG-36 | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Water Viscosifier | ||
+ | | Guar Gum | ||
+ | | 9000-30-0 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00002050 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| EC6486A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00006890 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 526: | Line 671: | ||
| 2113097 | | 2113097 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2012-10-31 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 533: | Line 678: | ||
| 2121762 | | 2121762 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2012-06-13 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 540: | Line 685: | ||
| 2147995 | | 2147995 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2013-03-15 |
| Administrative/File Review | | Administrative/File Review | ||
| In Compliance with Policy | | In Compliance with Policy | ||
Line 547: | Line 692: | ||
| 2151031 | | 2151031 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2013-03-08 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 554: | Line 699: | ||
| 2151032 | | 2151032 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2013-03-11 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 561: | Line 706: | ||
| 2151035 | | 2151035 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2013-03-12 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 568: | Line 713: | ||
| 2151054 | | 2151054 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2013-03-20 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 575: | Line 720: | ||
| 2164886 | | 2164886 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2013-04-23 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 582: | Line 727: | ||
| 2164889 | | 2164889 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2013-04-09 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 589: | Line 734: | ||
| 2164900 | | 2164900 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2013-04-03 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 596: | Line 741: | ||
| 2164910 | | 2164910 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2013-04-02 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 603: | Line 748: | ||
| 2164917 | | 2164917 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2013-03-25 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 610: | Line 755: | ||
| 2237163 | | 2237163 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2014-01-15 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 617: | Line 762: | ||
| 2252556 | | 2252556 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2014-03-11 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 624: | Line 769: | ||
| 2374024 | | 2374024 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2015-05-28 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 729: | Line 874: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-051-24524 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.035311,"lon":-79.77335,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Fayette | |
Municipality: Franklin Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 146724 | |
Farm/Lease Name: ROSA UNIT 11H | |
License Status: Active | |
Spud Date: 2012-10-27 | |
Permit Date: 2012-10-10 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 40.035311 | |
Longitude: -79.773350 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-10-24 | 2013-10-30 | 7649 | 3,052,140.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FR-66 | Halliburton | Friction Reducer | Hydrotreated Light Distillite | 64742-47-8 | 30 | 0.0003469 | 0 |
Clean Volume | Chevron Applachia, LLC | Carrier/Base Fluid | H20 | 7732-18-5 | 100 | 91.45 | 0 | |
EC 6116a | Nalco | Biocide | Polyethylene Glycol | 25322-68-3 | 60 | 0.0001453 | 0 | |
Dibromoacetonitrile | 3252-43-5 | 5 | 0.00001210 | 0 | ||||
1, 1-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00007270 | 0 | ||||
Proppant | Halliburton | Proppant | Crystalline Silica | 14808-60-7 | 100 | 8.55 | 0 | |
GBW-30 | Halliburton | Gel Breaker | Carbohydrates | 87246-72-8 | 95 | 0.00000720 | 0 | |
Hemicellulase enzyme | 9012-54-8 | 15 | 0.00000110 | 0 | ||||
15% Hcl Acid | Reagent/PPG | Used to open perfs | Hydrochloric Acid | 7647-01-0 | 15 | 0.0009878 | 0 | |
EC6673W | Nalco | Iron Control | Ethylene Glycol | 107-21-1 | 30 | 0.00006870 | 0 | |
WG-36 | Halliburton | Water Viscosifier | Guar Gum | 9000-30-0 | 100 | 0.00002050 | 0 | |
EC6486A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00006890 | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 454,438.00 | 188 | 0.00 | 0 | 45.83 | 184 |
2015 | CHEVRON APPALACHIA LLC | 442,938.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 298,613.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 228,618.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 191,262.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 43,032.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2012-S02 | Drill Cuttings (in Tons) | 50.17 Tons | LANDFILL | 100419 |
2013-S01 | Drill Cuttings (in Tons) | 233.52 Tons | LANDFILL | 100419 |
2013-S01 | Drilling Fluid Waste (in Barrels) | 1,654.20 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013-S01 | Drilling Fluid Waste (in Barrels) | 2,660.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Drill Cuttings (in Tons) | 644.38 Tons | LANDFILL | 100419 |
2013-S02 | Drilling Fluid Waste (in Barrels) | 187.40 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 777.70 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 25.10 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Fracing Fluid Waste (in Barrels) | 678.33 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S01 | Fracing Fluid Waste (in Barrels) | 4,941.17 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Fracturing Fluid Waste (in Tons) | 3.95 Tons | LANDFILL | 100172 |
2014-S01 | Fracturing Fluid Waste (in Tons) | 4.46 Tons | LANDFILL | 100592 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 1,059.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 9,503.83 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Fracturing Fluid Waste (in Tons) | 2.91 Tons | LANDFILL | 76-00-08 |
2014-S02 | Fracturing Fluid Waste (in Tons) | 28.84 Tons | STORAGE PENDING DISPOSAL OR REUSE | MID0209062814 |
2014-S02 | Produced Fluid (in Barrels) | 45.83 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2014-S02 | Produced Fluid (in Barrels) | 2,087.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Fracturing Fluid Waste (in Tons) | 1.76 Tons | LANDFILL | 073 114 654 |
2015-S01 | Produced Fluid (in Barrels) | 925.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 596.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 439.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 336.18 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 56.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 37.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 39.60 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 19.17 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | REUSE (AT WELL PAD) | |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 1,540.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 19.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 19.17 Bbl | REUSE (AT WELL PAD) | |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 21.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 19.17 Bbl | REUSE (AT WELL PAD) | |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | REUSE (AT WELL PAD) | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 19.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 37.17 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 38.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 17.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | REUSE (AT WELL PAD) | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | REUSE (AT WELL PAD) | |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 16.67 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 19.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 30.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 18.33 Bbl | REUSE (AT WELL PAD) | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 38.33 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2113097 | Primary Facility | 2012-10-31 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS , ROCKY MOUNTAIN # 1 DRILLING 24" CONDUCTOR CASING @ 70' (10/29/2012). |
2121762 | Primary Facility | 2012-06-13 | Routine/Complete Inspection | No Violations Noted | Pre-op Inspection of well site. Perimeter E&S in place and functioning. |
2147995 | Primary Facility | 2013-03-15 | Administrative/File Review | In Compliance with Policy | Operator self reported a spill of water/foam on the pad surface. The operator performed the reporting and cleanup of the spill in compliance with the current Department spill policy. |
2151031 | Primary Facility | 2013-03-08 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, RIGGING - UP ON ROSA # 11 - H TODAY. |
2151032 | Primary Facility | 2013-03-11 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS,CROWN # 5 DRILLING ON AIR @ 141' (TD). RUNNING WATER PROTECTION CASING AND CEMENTING TODAY(3/10/2013). |
2151035 | Primary Facility | 2013-03-12 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, CROWN # 5 DRILLING ON AIR @ 247'(TD).RUNNING COAL PROTECTION CASING AND CEMENTING TONIGHT (3/11/2013). |
2151054 | Primary Facility | 2013-03-20 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, CROWN # 5 DRILLING ON AIR @ 1601' WHEN MAKING A CONNECTION THE DRILL COLLARS, MOTOR,AND BIT TWISTED OFF (3/15/2013). PLANNING TO GO FISHING TODAY. RECIEVED A CALL ON SUNDAY(3/17/2013)MORNING TO BE ADVISED THEY LOST FISHING TOOLS IN THE HOLE. PLAN TO MOVE OFF AND LET TRIPPLE RIG FOLLOW -UP . |
2164886 | Primary Facility | 2013-04-23 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, PATTERSON # 334 DRILLING ON OIL BASE MUDD @ 12,208' (TD). RUNNING 51/2" PROD. CASING AND CEMENTING TONIGHT (4/22/2013). |
2164889 | Primary Facility | 2013-04-09 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, PATTERSON # 334 DRILLING ON OIL BASE MUDD @ 5430' TODAY. |
2164900 | Primary Facility | 2013-04-03 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, PATTERSON # 334 DRILLING ON FLOC FLUID @ 2209' (TD). RUNNING INTERMEDIATE CASING AND CEMENTING TONIGHT. |
2164910 | Primary Facility | 2013-04-02 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, FISHING MOTOR & DRILL BIT LEFT BY TOP HOLE RIG LAST WEEK.FISH IS OUT ,START DRILLING ON FLOC FLUIDS TODAY. |
2164917 | Primary Facility | 2013-03-25 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS,PATTERSON #334MOVING ON TO LOCATION (ROSA # 11 - H ) THIS WEEK (3/25/2013). |
2237163 | Primary Facility | 2014-01-15 | Routine/Complete Inspection | No Violations Noted | On 1/15/2014, the Department conducted an inspection of the Chevron Appalachia Rosa 6H to 11H well site in Franklinn Twp., Fayette County. |
2252556 | Primary Facility | 2014-03-11 | Routine/Complete Inspection | No Violations Noted | On 3/11/2014, the Department conducted an inspection at the Chevron Appalachia's Rosa 6H - 11H well site in Franklin Twp., Fayette County. The reason for the inspection was a request by the operator for an extension on the date that the site needed to be restored by. The original restoration date was 3/20/2014 and an extension to 3/20/16 is being requested. |
2374024 | Primary Facility | 2015-05-28 | Routine/Complete Inspection | No Violations Noted | |
2487020 | Primary Facility | 2016-05-05 | Routine/Complete Inspection | No Violations Noted | On 05/05/16 at approximately 0730 hours I conducted a routine complete inspection of the Rosa Unit. The Act 9 sign was in place and visible. All required documents were present in the mail box. The site overall was well vegetated. There were no violations observed at the time of inspection. |
2487045 | Primary Facility | 2016-05-13 | Routine/Complete Inspection | No Violations Noted |
On 05/05/16 at approximately 1300 hours I conducted a routine complete inspection of the Rosa Unit. The Act 9 sign was in place and visible. All required documents were present in the mail box. The site overall was well vegetated. The purpose of the site visit was to meet with Mr. Blaney, landowner of part of the area permitted, and Nick Staffieri of Chevron to discuss Mr. Blaney farming a portion of the area under permit to the north east and east of the pad. The area has traditionally been farmed and there were no waters of the Commonwealth present in the immediate area or downslope of the area to be farmed observed. Approval was granted to Mr. Blaney to begin farming his land. |
2566328 | Primary Facility | 2017-03-01 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present. The site was well vegetated and there were no signs of erosion observed. Despite heavy rains, stormwater controls appeared to be properly functioning. The on pad equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2584850 | Primary Facility | 2017-04-20 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. BMPs appeared to be well-maintained. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2603174 | Primary Facility | 2017-06-12 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place, but the E&S plans reflecting the major mod were not present on site. I contacted Chevron and a set of plans will be placed on the site. The site was well vegetated except the recently disturbed locations. PCSM had recently been added to the site and the disturbed areas appeared to have been seeded and mulched. There were no signs of erosion observed at the time of inspection. |
2617908 | Primary Facility | 2017-06-30 | Routine/Complete Inspection | No Violations Noted | Representatives of Chevron requested an on site meeting at the location to discuss the installation of a drainage channel. Since the site was constructed, a landowner constructed a home and graded the land adjacent to the access road to the south east. Chevron recently installed a drainage channel and rain garden on the opposite side of the access road and were to begin construction of the channel of interest when the landowner voiced their concerns that they did not want the channel installed.
The location where the channel is to be installed is well vegetated and there were no signs of erosion observed. Chevron is seeking guidance if the channel could not be installed and the plan amended by red line changes or if a major or minor modification would need to be submitted to DEP Environmental Engineering staff. This WQS is requesting guidance from Department Environmental Engineering staff regarding the issue. Once a determination has been made Chevron will be notified. |
2682065 | Primary Facility | 2018-01-10 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2734125 | Primary Facility | 2018-05-24 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2771492 | Primary Facility | 2018-08-27 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion were observed. The access road showed signs of washout. It is recommended the road receive maintenance.
Installed PCSM features appeared to be in good condition. The roadside ditch along the right side of the access road adjacent to a property owner's yard was still not installed. The property owner requested the ditch not be installed to allow them to mow their yard more easily. Chevron is currently preparing a modification to submit to the Department to address the issue. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
For data sources see[7]