X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-051-24517

Well Details

Well ID: 37-051-24517
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Nicholson Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 149173
Farm/Lease Name: REJISS UNIT 3H
License Status: Active
Spud Date: 2012-09-26
Permit Date: 2012-09-12
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 39.835514
Longitude: -79.884775

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-09-03 2014-10-02 7889 5,982,040.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 L058 Schlumberger Iron Stabilizer Sodium erythorbate 6381-77-7 100 0.00050206 0
EC6116A Nalco Biocide Dibromoacetonitrile 3252-43-5 5 0.00012873 0
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00077236 0
Polyethylene Glycol 25322-68-3 60 0.00154472 0
7.5% Acid Schlumberger Perf Cleanup Hydrocloric Acid 7647-01-0 8 0.017986 0
EC6673W Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00091213 0
D047 Schlumberger Antifoam Agent Polypropylene Glycol 25322-69-4 100 0.00000780 0
J624 Schlumberger Surfactant Gelling Agent Propan-2-ol 67-63-0 30 0.00012349 0
Fatty Acid Amidoalkyl Betaine Proprietary 60 0.00024698 0
J134 Schlumberger Gel Breaker Hemicellulase Enzyme 9012-54-8 100 0.00083885 0
J580 Schlumberger Gelling Agent Carbohydrate polymer Proprietary 100 0.0178325 0
J609W Schlumberger Friction Reducer Urea 57-13-6 5 0.0006224 0
Ammonium Sulfate 7783-20-2 30 0.00373439 0
Base Fluid Chevron Carrier/Base Fluid Water (Including Mix Water Supplied by Client) 7732-18-5 100 90.7115 0
A264 Schlumberger Corrosion Inhibitor Methanol 67-56-1 40 0.00004118 0
Aliphatic alcohols, ethoxylayed #1 Proprietary 30 0.00003089 0
Aliphatic acids Proprietary 30 0.00003089 0
Prop-2-yn-1-ol 107-19-7 10 0.00001030 0
EC6486A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00081906 0
Proppant Schlumberger Proppant Crystalline Silica 14808-60-7 100 9.12939 0
J567 Schlumberger Encapsulated Breaker Sulfonated Polystyrene Proprietary 100 0.00028065 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 31,292.00 9 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 1,178,317.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 859,916.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 642,071.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 499,289.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 106,453.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-S02 Drill Cuttings (in Tons) 629.10 Tons LANDFILL 100419
2012-S02 Drilling Fluid Waste (in Barrels) 4,094.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012-S02 Drilling Fluid Waste (in Barrels) 402.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S01 Drill Cuttings (in Tons) 511.40 Tons LANDFILL 100419
2013-S01 Drilling Fluid Waste (in Barrels) 439.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013-S02 Drill Cuttings (in Tons) 209.97 Tons LANDFILL 100419
2013-S02 Drilling Fluid Waste (in Barrels) 80.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Fracing Fluid Waste (in Barrels) 3,380.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015-S01 Fracing Fluid Waste (in Barrels) 5,461.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015-S01 Fracing Fluid Waste (in Barrels) 2,533.33 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Fracturing Fluid Waste (in Tons) 2.90 Tons LANDFILL 100172
2015-S01 Fracturing Fluid Waste (in Tons) 24.44 Tons LANDFILL 100277
2015-S01 Fracturing Fluid Waste (in Tons) 18.77 Tons RESIDUAL WASTE TRANSFER FACILITY MID074259565
2015-S01 Produced Fluid (in Barrels) 281.67 Bbl INJECTION DISPOSAL WELL 34-121-23995
2015-S01 Produced Fluid (in Barrels) 73.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015-S01 Produced Fluid (in Barrels) 4,700.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 1,280.32 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 1,447.67 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Produced Fluid (in Barrels) RWC 802 736.04 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-S02 Produced Fluid (in Barrels) RWC 802 151.67 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 148.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M02 Produced Fluid (in Barrels) RWC 802 111.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M03 Produced Fluid (in Barrels) RWC 802 41.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M03 Produced Fluid (in Barrels) RWC 802 36.67 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 36.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M04 Produced Fluid (in Barrels) RWC 802 40.00 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 1,540.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-M05 Produced Fluid (in Barrels) RWC 802 1,610.00 Bbl REUSE (AT WELL PAD)
2017-M06 Produced Fluid (in Barrels) RWC 802 78.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M07 Produced Fluid (in Barrels) RWC 802 37.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017-M07 Produced Fluid (in Barrels) RWC 802 36.67 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 74.67 Bbl REUSE (AT WELL PAD)
2017-M09 Produced Fluid (in Barrels) RWC 802 36.67 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 73.33 Bbl REUSE (AT WELL PAD)
2017-M11 Produced Fluid (in Barrels) RWC 802 28.33 Bbl INJECTION DISPOSAL WELL 34-119-28776
2017-M11 Produced Fluid (in Barrels) RWC 802 35.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-M11 Produced Fluid (in Barrels) RWC 802 38.33 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M12 Produced Fluid (in Barrels) RWC 802 24.16 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M01 Produced Fluid (in Barrels) RWC 802 37.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018-M01 Produced Fluid (in Barrels) RWC 802 80.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M02 Produced Fluid (in Barrels) RWC 802 73.33 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 35.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M03 Produced Fluid (in Barrels) RWC 802 38.33 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M04 Produced Fluid (in Barrels) RWC 802 35.00 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 40.00 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 39.33 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 38.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M07 Produced Fluid (in Barrels) RWC 802 36.67 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 38.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M08 Produced Fluid (in Barrels) RWC 802 36.67 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M09 Produced Fluid (in Barrels) RWC 802 73.33 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M11 Produced Fluid (in Barrels) RWC 802 78.33 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M12 Produced Fluid (in Barrels) RWC 802 38.33 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M01 Produced Fluid (in Barrels) RWC 802 76.67 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 36.67 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 80.00 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2113092 Primary Facility 2012-09-26 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,CONDUCTOR SET @ 50' ON (9/26/2012).
2121933 Primary Facility 2012-08-23 Routine/Complete Inspection No Violations Noted Pre-op Inspection of well site. Perimeter E&S in place and functioning.
2126373 Primary Facility 2012-11-22 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 9 MOVING ON TO REJISS # 3 -- H TODAY.
2126385 Primary Facility 2012-11-27 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 9 DRILLING ON AIR @ 300' (TD) (11/24/2012). RAN WATER PRODUCTION CASING AND CEMENTING TODAY.ON (11/26/2012)DRILLING TO (TD).525' RUNNING COAL PROTECTION CASING AND CEMENTING TONIGHT.
2126392 Primary Facility 2012-11-29 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 9 DRILLING ON AIR @ 2620' (TD).RUNNING INTERMEDIATE CASING AND CEMENTING TONIGHT.
2134428 Primary Facility 2012-12-03 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 9 DRILLING ON AIR @ 6888' (TD) .RUNNING BRIDGE PLUG AND LOADING HOLE WITH OIL BASE MUD. CAPPING AND MOVING TO REJISS # 1 - H .
2139680 Primary Facility 2013-02-14 Routine/Complete Inspection No Violations Noted Site Id sign up, guarded, plans and permits in box, E&S in place and functioning, some slopes may need to be monitored to ensure stability-stable now.
2162637 Primary Facility 2013-04-30 Routine/Complete Inspection No Violations Noted Sign up, E&S, PPC, permits in box. E&S in place and functioning. Good growth on site. No activity recently.
2178435 Primary Facility 2013-06-19 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 339 DRILLING ON FLUID @ 13,546' (TD). RUNNING 5 1/2" PROD. CASING AND CEMENTING TONIGHT.
2178438 Primary Facility 2013-06-07 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 339 MOVED ON TO LOCATION REJISS # 3 - H (6/8/2013).
2205667 Primary Facility 2013-09-17 Routine/Complete Inspection No Violations Noted Act 9 sign up, three wells in not fracked yet, area stable, plans and permits in box.
2252488 Primary Facility 2014-03-11 Routine/Complete Inspection No Violations Noted On 3/11/2014, I conducted an inspection at the Chevron Appalachia’s Rejiss 1H, 2H, 3H Well Unit site in Nicholson Twp., Fayette County. The reason for the inspection was a request by the operator for an extension on the date that the site needed to be restored by. The original restoration date was 3/19/2014 and an extension to 3/19/16 is being requested.
2358708 Primary Facility 2015-01-27 Routine/Complete Inspection No Violations Noted
2467655 Primary Facility 2016-03-16 Complaint Inspection No Violations Noted On 03/16/16 at approximately 0930 hours I conducted a complaint inspection of the Rejiss well site. The Act 9 sign was in place and all required documents were present at the site.
The site overall was well vegetated and there were no signs of erosion & sedimentation at the site. A significant amount of stone was also present on the slope of the topsoil stock pile at the southern corner of the well site. It is recommended that this be removed.

The complaint against the site alleged that it was not built to the specifications of the approved E&S plans and that the stockpiles were causing environmental concerns. No environmental harm was observed due to the stock piles. The site appears to have been built to plan with the exception of two locations of gravel that appear to be gravel pull offs. One is located near the main site entrance on the northeast side of the access road and the second is near the debris pile on the southwestern access road. This is a violation of 102.5(m)(4).

2731513 Primary Facility 2018-05-14 Compliance Evaluation No Violations Noted The Act 9 sign was in place and all required documents were present at the site. Previously, an NOV had been issued for two gravel pull offs along the access road that were not permitted. The gravel pull offs have been removed and the site has been restored. The site was well vegetated and there were no signs of erosion observed. There were no violations observed at the time of inspection.

For data sources see[7]

References