X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-051-24469"

m
m
 
(2 intermediate revisions by the same user not shown)
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-051-24469
 
| Well ID: 37-051-24469
| style="height=100%; align=center" rowspan="14" | {{#display_map: 39.947014, -79.743531 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 39.947014, -79.743531 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 19: Line 19:
 
| Farm/Lease Name: KIKTA UNIT 2H
 
| Farm/Lease Name: KIKTA UNIT 2H
 
|-
 
|-
| License Status: Active
+
| License Status:  
 
|-
 
|-
| Spud Date: 10/21/2011
+
| Spud Date:  
 
|-
 
|-
| Permit Date: 9/30/2011
+
| Permit Date: 2011-09-30
 +
|-
 +
| Well Type: GAS
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
 
|-
 
|-
 
| Configuration: Horizontal Well
 
| Configuration: Horizontal Well
 +
|-
 +
| Conservation: Yes
 
|-
 
|-
 
| Latitude: 39.947014
 
| Latitude: 39.947014
Line 49: Line 53:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2011-09-30
 +
| New Permit Application
 +
|-
 +
| 2011-10-21
 +
| Performed Spud Operation
 +
|-
 +
| 2012-05-08
 +
| Drilling Completion
 +
|-
 +
| 2012-12-05
 +
| Perforation
 +
|-
 +
| 2012-12-05
 +
| Performed Stimulation 
 +
|-
 +
| 2016-04-11
 +
| DEVIATED
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2012-12-05
 +
| 2012-12-05
 +
| style="text-align: right;" | 8,025
 +
| style="text-align: right;" | 3,265,849
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="12"| 1
 +
| rowspan="1"| Proppant (lbs)
 +
| rowspan="1"|
 +
| rowspan="1"| Proppant
 +
|
 +
|
 +
| style="text-align: right;" | 8.86
 +
| style="text-align: right;" | 9.80
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Clean Volume (gals)
 +
| rowspan="1"|
 +
| rowspan="1"| Carrier/Base Fluid
 +
|
 +
|
 +
| style="text-align: right;" | 91.14
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| GBL
 +
| rowspan="1"| Clearwater International
 +
| rowspan="1"| Gel Breaker
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Iron Control A
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Iron Control
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00693000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="3"| Biocide EC 6116A
 +
| rowspan="3"| Nalco
 +
| rowspan="3"| Biocide
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00692000
 +
| style="text-align: right;" |
 +
|-
 +
| Polyethylene glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
| Dibromoacetonitrile
 +
| 3252-43-5
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00115000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Scale Inhibitor A
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Scale Inhibitor
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00634000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| 7.5 Hcl Acid
 +
| rowspan="1"|
 +
| rowspan="1"| Used to open perfs
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 7.50
 +
| style="text-align: right;" | 0.28
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Unislik ST 50
 +
| rowspan="1"| CESI Chemical
 +
| rowspan="1"| Friction Reducer
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| CMHPG
 +
| rowspan="1"| Ashland
 +
| rowspan="1"| Water Viscosifier
 +
| Carboxymethylhydroxyporoyl guar blend
 +
|
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00168000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| ASP 900
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Friction Reducer
 +
| Ammonium sulfate
 +
| 7783-20-2
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
| 2012-12-05
 +
| style="text-align: right;" |
 +
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Completion Reports - Stimulations
 +
| publisher = Pennsylvania Department of Conservation and Natural Resources
 +
| date = 2020-03-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-03-02 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 134: Line 339:
 
| 2019
 
| 2019
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 32,678.00
+
| style="text-align: right;" | 122,193.00
| style="text-align: right;" | 90
+
| style="text-align: right;" | 365
 
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
Line 151: Line 356:
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Period
 
!scope="col" | Period
 +
!scope="col" | Operator
 
!scope="col" | Waste Type
 
!scope="col" | Waste Type
 
!scope="col" | Quantity
 
!scope="col" | Quantity
Line 156: Line 362:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2011-S02
+
| 2011
| Drilling Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
 +
| Drilling Fluid Waste
 
| style="text-align: right;" | 1,795.00 Bbl
 
| style="text-align: right;" | 1,795.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW001
 
| WMGR123SW001
 
|-
 
|-
| 2011-S02
+
| 2011
| Fracing Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 
| style="text-align: right;" | 165.00 Bbl
 
| style="text-align: right;" | 165.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2012-S01
+
| 2012
| Drilling Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 2,263.50 Bbl
+
| Drilling Fluid Waste
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| style="text-align: right;" | 100.00 Bbl
| WMGR123SW001
 
|-
 
| 2012-S01
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 449.00 Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2012-S02
+
| 2012
| Drilling Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 50.00 Bbl
+
| Fracing Fluid Waste
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| style="text-align: right;" | 2,542.50 Bbl
| WMGR123SW001
 
|-
 
| 2012-S02
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 100.00 Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2012-S02
+
| 2012
| Fracing Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 
| style="text-align: right;" | 290.00 Bbl
 
| style="text-align: right;" | 290.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW001
 
| WMGR123SW001
 
|-
 
|-
| 2012-S02
+
| 2012
| Fracing Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 2,093.50 Bbl
+
| Drilling Fluid Waste
| REUSE OTHER THAN ROAD SPREADING
+
| style="text-align: right;" | 2,313.50 Bbl
|  
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123SW001
 
|-
 
|-
| 2013-S01
+
| 2013
| Fracing Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 
| style="text-align: right;" | 243.00 Bbl
 
| style="text-align: right;" | 243.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW001
 
| WMGR123SW001
 
|-
 
|-
| 2013-S01
+
| 2013
| Fracing Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 4,374.50 Bbl
+
| Fracturing Fluid Waste
| REUSE OTHER THAN ROAD SPREADING
+
| style="text-align: right;" | 54.87 Tons
|  
+
| LANDFILL
 +
| 073 114 654
 
|-
 
|-
| 2013-S02
+
| 2013
| Fracing Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste
 
| style="text-align: right;" | 2,737.50 Bbl
 
| style="text-align: right;" | 2,737.50 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123SW001
 
| WMGR123SW001
 
|-
 
|-
| 2013-S02
+
| 2013
| Fracing Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 25,730.75 Bbl
+
| Fracing Fluid Waste
 +
| style="text-align: right;" | 30,105.25 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2013-S02
+
| 2013
| Fracturing Fluid Waste (in Tons)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 54.87 Tons
+
| Produced Fluid
| LANDFILL
 
| 073 114 654
 
|-
 
| 2013-S02
 
| Produced Fluid (in Barrels)
 
 
| style="text-align: right;" | 1,210.00 Bbl
 
| style="text-align: right;" | 1,210.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-121-23995
 
| 34-121-23995
 
|-
 
|-
| 2014-S01
+
| 2014
| Drilling Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 75.00 Bbl
+
| Produced Fluid
 +
| style="text-align: right;" | 809.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2014-S01
+
| 2014
| Fracturing Fluid Waste (in Tons)
+
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracturing Fluid Waste
 
| style="text-align: right;" | 9.12 Tons
 
| style="text-align: right;" | 9.12 Tons
 
| STORAGE PENDING DISPOSAL OR REUSE
 
| STORAGE PENDING DISPOSAL OR REUSE
 
| MID074259565
 
| MID074259565
 
|-
 
|-
| 2014-S01
+
| 2014
| Produced Fluid (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 
| style="text-align: right;" | 978.75 Bbl
 
| style="text-align: right;" | 978.75 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-121-23995
 
| 34-121-23995
 
|-
 
|-
| 2014-S01
+
| 2014
| Produced Fluid (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 225.00 Bbl
+
| Drilling Fluid Waste
 +
| style="text-align: right;" | 75.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2014-S02
+
| 2015
| Produced Fluid (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 584.00 Bbl
+
| Produced Fluid
 +
| style="text-align: right;" | 722.50 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-S01
+
| 2016
| Produced Fluid (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 406.25 Bbl
+
| Produced Fluid
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 316.25 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 265.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2016-S02
 
| Produced Fluid (in Barrels) RWC 802
 
 
| style="text-align: right;" | 149.26 Bbl
 
| style="text-align: right;" | 149.26 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW019
 
| WMGR123SW019
 
|-
 
|-
| 2016-S02
+
| 2016
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 85.00 Bbl
+
| Produced Fluid
 +
| style="text-align: right;" | 350.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2017-M02
+
| 2017
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 81.25 Bbl
+
| Produced Fluid
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW019
 
|-
 
| 2017-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M04
 
| Produced Fluid (in Barrels) RWC 802
 
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW001
 
| WMGR123SW001
 
|-
 
|-
| 2017-M06
+
| 2017
| Drilling Fluid Waste (in Barrels) RWC 803
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 27.50 Bbl
+
| Produced Fluid
 +
| style="text-align: right;" | 108.75 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW019
 
| WMGR123SW019
 
|-
 
|-
| 2017-M06
+
| 2017
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 27.50 Bbl
+
| Produced Fluid
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW019
 
|-
 
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 28.75 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
 
| style="text-align: right;" | 57.75 Bbl
 
| style="text-align: right;" | 57.75 Bbl
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
| 2018-M01
+
| 2017
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
 +
| Drilling Fluid Waste
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
+
| RESIDUAL WASTE PROCESSING FACILITY
|  
+
| WMGR123SW019
 
|-
 
|-
| 2018-M02
+
| 2017
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 25.00 Bbl
+
| Produced Fluid
 +
| style="text-align: right;" | 138.75 Bbl
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
| 2018-M02
+
| 2018
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 56.25 Bbl
+
| Produced Fluid
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
+
| style="text-align: right;" | 162.25 Bbl
|
 
|-
 
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 53.50 Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
| 2018-M05
+
| 2018
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 28.75 Bbl
+
| Produced Fluid
| REUSE (AT WELL PAD)
+
| style="text-align: right;" | 192.50 Bbl
|
 
|-
 
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 52.50 Bbl
 
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
| 2018-M11
+
| 2019
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 56.25 Bbl
+
| Produced Fluid
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
+
| style="text-align: right;" | 325.00 Bbl
|
 
|-
 
| 2019-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2019-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.00 Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
Line 439: Line 563:
 
| 2026398
 
| 2026398
 
| Primary Facility
 
| Primary Facility
| 12/13/2011
+
| 2011-12-13
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 446: Line 570:
 
| 2026399
 
| 2026399
 
| Primary Facility
 
| Primary Facility
| 12/12/2011
+
| 2011-12-12
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 453: Line 577:
 
| 2026400
 
| 2026400
 
| Primary Facility
 
| Primary Facility
| 12/08/2011
+
| 2011-12-08
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 460: Line 584:
 
| 2026403
 
| 2026403
 
| Primary Facility
 
| Primary Facility
| 12/07/2011
+
| 2011-12-07
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 467: Line 591:
 
| 2038565
 
| 2038565
 
| Primary Facility
 
| Primary Facility
| 01/30/2012
+
| 2012-01-30
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 474: Line 598:
 
| 2039144
 
| 2039144
 
| Primary Facility
 
| Primary Facility
| 01/25/2012
+
| 2012-01-25
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 481: Line 605:
 
| 2055103
 
| 2055103
 
| Primary Facility
 
| Primary Facility
| 02/07/2012
+
| 2012-02-07
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 488: Line 612:
 
| 2055107
 
| 2055107
 
| Primary Facility
 
| Primary Facility
| 02/02/2012
+
| 2012-02-02
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 495: Line 619:
 
| 2055110
 
| 2055110
 
| Primary Facility
 
| Primary Facility
| 01/29/2012
+
| 2012-01-29
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 502: Line 626:
 
| 2065713
 
| 2065713
 
| Primary Facility
 
| Primary Facility
| 04/23/2012
+
| 2012-04-23
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 509: Line 633:
 
| 2065715
 
| 2065715
 
| Primary Facility
 
| Primary Facility
| 05/03/2012
+
| 2012-05-03
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 516: Line 640:
 
| 2071922
 
| 2071922
 
| Primary Facility
 
| Primary Facility
| 05/07/2012
+
| 2012-05-07
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 523: Line 647:
 
| 2071923
 
| 2071923
 
| Primary Facility
 
| Primary Facility
| 04/23/2012
+
| 2012-04-23
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 530: Line 654:
 
| 2077302
 
| 2077302
 
| Primary Facility
 
| Primary Facility
| 06/20/2012
+
| 2012-06-20
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 537: Line 661:
 
| 2147964
 
| 2147964
 
| Primary Facility
 
| Primary Facility
| 03/14/2013
+
| 2013-03-14
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 544: Line 668:
 
| 2185048
 
| 2185048
 
| Primary Facility
 
| Primary Facility
| 07/19/2013
+
| 2013-07-19
 
| Site Restoration
 
| Site Restoration
 
| No Violations Noted
 
| No Violations Noted
Line 551: Line 675:
 
| 2209809
 
| 2209809
 
| Primary Facility
 
| Primary Facility
| 10/02/2013
+
| 2013-10-02
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 558: Line 682:
 
| 2273907
 
| 2273907
 
| Primary Facility
 
| Primary Facility
| 05/22/2014
+
| 2014-05-22
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 565: Line 689:
 
| 2316604
 
| 2316604
 
| Primary Facility
 
| Primary Facility
| 10/24/2014
+
| 2014-10-24
 
| Complaint Inspection
 
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 572: Line 696:
 
| 2379931
 
| 2379931
 
| Primary Facility
 
| Primary Facility
| 06/02/2015
+
| 2015-06-02
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 639: Line 763:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 12/05/2012
 
| 12/05/2012
 
| style="text-align: right;" | 8025.00
 
| style="text-align: right;" | 3,265,849.0
 
| style="text-align: right;" |
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="12"| 1
 
| rowspan="1"| Proppant (lbs)
 
| rowspan="1"|
 
| rowspan="1"| Proppant
 
|
 
|
 
| style="text-align: right;" | 8.86
 
| style="text-align: right;" | 9.80
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Clean Volume (gals)
 
| rowspan="1"|
 
| rowspan="1"| Carrier/Base Fluid
 
|
 
|
 
| style="text-align: right;" | 91.14
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| GBL
 
| rowspan="1"| Clearwater International
 
| rowspan="1"| Gel Breaker
 
| Ethylene glycol
 
| 107-21-1
 
| style="text-align: right;" | 60.00
 
| style="text-align: right;" | 0.00002000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Iron Control A
 
| rowspan="1"| Nalco
 
| rowspan="1"| Iron Control
 
| Ethylene glycol
 
| 107-21-1
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00693000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="3"| Biocide EC 6116A
 
| rowspan="3"| Nalco
 
| rowspan="3"| Biocide
 
| 2,2-Dibromo-3-nitrilopropionamide
 
| 10222-01-2
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00692000
 
| style="text-align: right;" |
 
|-
 
| Polyethylene glycol
 
| 25322-68-3
 
| style="text-align: right;" | 60.00
 
| style="text-align: right;" | 0.01
 
| style="text-align: right;" |
 
|-
 
| Dibromoacetonitrile
 
| 3252-43-5
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00115000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Scale Inhibitor A
 
| rowspan="1"| Nalco
 
| rowspan="1"| Scale Inhibitor
 
| Ethylene glycol
 
| 107-21-1
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00634000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| 7.5 Hcl Acid
 
| rowspan="1"|
 
| rowspan="1"| Used to open perfs
 
| Hydrochloric acid
 
| 7647-01-0
 
| style="text-align: right;" | 7.50
 
| style="text-align: right;" | 0.28
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Unislik ST 50
 
| rowspan="1"| CESI Chemical
 
| rowspan="1"| Friction Reducer
 
| Distillates, petroleum, hydrotreated light
 
| 64742-47-8
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.03
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| CMHPG
 
| rowspan="1"| Ashland
 
| rowspan="1"| Water Viscosifier
 
| Carboxymethylhydroxyporoyl guar blend
 
|
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 0.00168000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| ASP 900
 
| rowspan="1"| Nalco
 
| rowspan="1"| Friction Reducer
 
| Ammonium sulfate
 
| 7783-20-2
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Latest revision as of 12:49, 16 May 2020

Well Details

Well ID: 37-051-24469
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: North Union Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148680
Farm/Lease Name: KIKTA UNIT 2H
License Status:
Spud Date:
Permit Date: 2011-09-30
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.947014
Longitude: -79.743531

For data sources see[1][2][3]

Well History

Date Event
2011-09-30 New Permit Application
2011-10-21 Performed Spud Operation
2012-05-08 Drilling Completion
2012-12-05 Perforation
2012-12-05 Performed Stimulation
2016-04-11 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-12-05 2012-12-05 8,025 3,265,849

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Proppant (lbs) Proppant 8.86 9.80
Clean Volume (gals) Carrier/Base Fluid 91.14 100.00
GBL Clearwater International Gel Breaker Ethylene glycol 107-21-1 60.00 0.00002000
Iron Control A Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00693000
Biocide EC 6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00692000
Polyethylene glycol 25322-68-3 60.00 0.01
Dibromoacetonitrile 3252-43-5 5.00 0.00115000
Scale Inhibitor A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00634000
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.28
Unislik ST 50 CESI Chemical Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
CMHPG Ashland Water Viscosifier Carboxymethylhydroxyporoyl guar blend 100.00 0.00168000
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-12-05 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 359,787.00 306 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 329,063.00 365 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 232,145.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 177,227.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 157,229.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 134,880.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 122,193.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 1,795.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2011 CHEVRON APPALACHIA LLC Fracing Fluid Waste 165.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 100.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 2,542.50 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 290.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 2,313.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 243.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 54.87 Tons LANDFILL 073 114 654
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 2,737.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 30,105.25 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Produced Fluid 1,210.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Produced Fluid 809.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 9.12 Tons STORAGE PENDING DISPOSAL OR REUSE MID074259565
2014 CHEVRON APPALACHIA LLC Produced Fluid 978.75 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Drilling Fluid Waste 75.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 722.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 149.26 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 350.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 108.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 57.75 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Drilling Fluid Waste 27.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 138.75 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 162.25 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 192.50 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 325.00 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2026398 Primary Facility 2011-12-13 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,RIG MOVING OVER TO (KIKTA 1 - H ) TODAY.
2026399 Primary Facility 2011-12-12 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 2508',RUNNING INTERMEDIATE CASING AND CEMENTING TONIGHT. COAL PROTECTION CASING (TD) @ 978' (12/9/2011)AND CEMENTED.
2026400 Primary Facility 2011-12-08 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 302'. RUNNING WATER PROTECTION CASING AND CEMENTING TONIGHT.
2026403 Primary Facility 2011-12-07 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, MOVED ON (12/6/2011) RIGGING UP TODAY.
2038565 Primary Facility 2012-01-30 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,DRILLING ON AIR @ 3363' TODAY.
2039144 Primary Facility 2012-01-25 Routine/Complete Inspection No Violations Noted The Department was at the above referenced Marcellus Well to conduct an inspection after being notified of stream contamination down gradient of this well site. The Department observed impacts to an unnamed tributary down gradient of this Well. The stream was gray/reddish in color. The Department took samples of the stream and also took samples of the drilling mud on site. The Driller on site said that they were drilling on air until 3:00AM in the morning. Apparently the stream had turned colors the day before on 1/24/12 at approximately 1:30PM. The Driller also said they have casing set at a depth of 2,534 ft. The Department grabbed a sample of the black drill mud to determine who was at fault for the stream contamination. The Department will provide sample results to the Operator. Another company is conducting a HDD bore adjacent to this Marcellus Operation. All parties will receive sample results and will be notified of the Department's final determination to the cause of the stream contamination.
2055103 Primary Facility 2012-02-07 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING @ 6948' (2/6/2012). CEMENTING PLUG BACK TO 6754' (KOP) .
2055107 Primary Facility 2012-02-02 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON AIR @ 5811' TODAY.
2055110 Primary Facility 2012-01-29 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, MOVING ON LOCATION TODAY.
2065713 Primary Facility 2012-04-23 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 325 MOVED ON (4/22/2012). STARTED DRILLING @ 6274'.(KOP) @ 6293'.
2065715 Primary Facility 2012-05-03 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON 325 DRILLING ON FLUID @ 10,687' TODAY. PLANNING TO DO OPEN HOLE SIDE TRACK, (ENCOUNTER A FAULT).
2071922 Primary Facility 2012-05-07 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,PATTERSON # 325 DRILLING ON FLUID @ 11.187'(TD). RUNNING 51?2" PROD. CASING AND CEMENTING TONIGHT.
2071923 Primary Facility 2012-04-23 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 325 MOVE ON DATE (4/22/2012).
2077302 Primary Facility 2012-06-20 Routine/Complete Inspection No Violations Noted Rig off site, pit being dug out but still on site, E&S ok.
2147964 Primary Facility 2013-03-14 Routine/Complete Inspection No Violations Noted Site ID sign up and E&S, PPC and permits in box. Flow back work going on, 3 tanks in containment in, 4 heater units in, pipeline connected, E&S in place and functioning. Two pits/impoundments good freeboard, strong smell of frack water from one impoundment. Three sed traps in place. Site stable.
2185048 Primary Facility 2013-07-19 Site Restoration No Violations Noted Site restoration extension requested. Site stable and has good vegetative growth. Extension approved until the new date of 12/5/2014.
2209809 Primary Facility 2013-10-02 Routine/Complete Inspection No Violations Noted Act 9 sign up, permits and plans in box, last pit being removed, wells labeled, no E&S issues.
2273907 Primary Facility 2014-05-22 Routine/Complete Inspection No Violations Noted On 5/22/2014, the Department conducted an inspection of Chevron Appalachia’s Kikta Unit 1, 2, 3, 4H well site in North Union Twp., Fayette County.
2316604 Primary Facility 2014-10-24 Complaint Inspection No Violations Noted 4 wells drilled and producing. Site graded and vegetation started.
2379931 Primary Facility 2015-06-02 Routine/Complete Inspection No Violations Noted
2446484 Primary Facility 2016-02-01 Routine/Complete Inspection No Violations Noted

On 02/01/16 at approximately 1330 hours I conducted a site restoration inspection in response to an NOT submittal by Chevron Appalachia LLC. The Act 9 sign was in place and all required documents were present at the site.

The site was well vegetated and met the requirements of uniform 70% growth. All temporary BMPs had been removed from the site and there was no unnecessary equipment present at the site. The NOT is approved.

2563784 Primary Facility 2017-02-22 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present. The site was well vegetated and there were no signs of erosion observed at the time of inspection. The equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2666273 Primary Facility 2017-11-20 Complaint Inspection No Violations Noted An inspection was conducted in response to a water supply complaint. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition and there were no signs of leaks or spills. There were no violations observed at the time of inspection.
2825635 Primary Facility 2019-01-11 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The well head casing, piping, production set equipment, containment dike and tank battery look ok.

For data sources see[9]

References