37-051-24443

Well Details

Well ID: 37-051-24443
Loading map...
County: Fayette
Municipality: Bullskin Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148470
Farm/Lease Name: HAMBORSKY UNIT 13H
First Permit Date: 2011-05-16
Last Permit Date: 2011-05-16
Spud Date: 2011-06-14
Unconventional: Yes
Horizontal: Yes
Well Status: ACTIVE
Violations: 0
Latitude: 40.07278
Longitude: -79.577325

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2011-1 0.0 0.0 0.0 0.0 0.0 0.0
2011-2 0.0 0.0 0.0 0.0 0.0 0.0
2012-1 0.0 0.0 0.0 0.0 0.0 0.0
2012-2 0.0 0.0 0.0 0.0 0.0 0.0
2013-1 287053.0 181.0 0.0 0.0 0.0 0.0
2013-2 251924.0 184.0 0.0 0.0 0.0 0.0
2014-1 195106.0 181.0 0.0 0.0 0.0 0.0
2014-2 154775.0 106.0 0.0 0.0 0.0 0.0
2015-02 20139.0 28.0 0.0 0.0 0.0 0.0
2015-01 31521.0 31.0 0.0 0.0 0.0 0.0
2015-03 31928.0 31.0 0.0 0.0 0.0 0.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2011-2 DRILLING FLUID WASTE 115.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2012-1 DRILLING FLUID WASTE 6.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2012-1 FRACING FLUID WASTE 25.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2012-2 DRILL CUTTINGS 2.85 Tons LANDFILL 100419 ADVANCED DISPOSAL SERVICE CHESTNUT VALLEY LANDFILL MCCLELLANDTOWN PA
2012-2 FLOWBACK FRACTURING SAND 109.47 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2012-2 FRACING FLUID WASTE 5.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2012-2 FRACING FLUID WASTE 1.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2012-2 PRODUCED FLUID 2.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2013-1 DRILLING FLUID WASTE 90.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-1 FLOWBACK FRACTURING SAND 68.61 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2013-1 PRODUCED FLUID 1.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING
2013-2 PRODUCED FLUID 560.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 PRODUCED FLUID 413.5 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-2 PRODUCED FLUID 167.5 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
2004968 2011-08-02 No Violations Noted HORIZONTAL MARCELLUS, E&S & PITS IN GOOD CONDITION. YOST # 5 DRILLING ON AIR TO 259' . CEMENTING WATER PROTECTIVE CASING ON 8/2/2011.
2004986 2011-08-04 No Violations Noted HORIZONTAL MARCELLUS, E&S & PITS IN GOOD CONDITION. YOST # 5 DRILLING ON AIR TO 1172'. CEMENTING COAL PROTECTIVE CASING ON 8/4/2011.
2005001 2011-08-11 No Violations Noted HORIZONTAL MARCELLUS, E&S & PITS IN GOOD CONDITION. YOST # 5 DRILLING ON AIR TO 2664'. CEMENTING INTERMEDIATE CASING ON 8/11/2011. RETURNS TO SURFACE OF 10 SACKS.
2005005 2011-09-12 No Violations Noted HORIZONTAL MARCELLUS,E& S & PITS IN GOOD CONDITION.CROWN # 5 DRILLING ON FLUID TO 6500'. MUDDED -UP AND CAPPED.
2025468 2011-11-22 No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 339 TD ON FLUID @ 13,257' TODAY, RUNNING PROD. CASING AND CEMENTING TONIGHT.
2025519 2011-11-09 No Violations Noted HORIZONTAL MARCELLUS,PATTERSON # 339 DRILLING ON FLUID @ 7257' TODAY.
2025524 2011-11-07 No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 339 RIGGING UP TODAY,TESTING (BOP).
2088711 2012-08-02 No Violations Noted Site ID sign in place, E&S plan, PPC plan, and well permits on site, Road good, E&S controls in place and fuctioning, good vegetative growth on site.
2107521 2012-09-27 No Violations Noted Operator requested restoration extension. Site is stable, actively being reclaimed at this time. Pits already filled in and being regraded. Extension approved until 8/29/2013.
2146011 2013-03-05 No Violations Noted Site has had pits and impoundments reclaimed. Two sed traps still present. Site locked but not guarded. Wells labeled, two tanks in containment. Area may need new round of mulch and seed this spring.
2205805 2013-09-18 No Violations Noted Act 9 sign up, permits and plans in box, wells in production, no leaks, wells labeled. Area of sed trap needs touched up with seed and mulch.
2218003 2013-10-30 No Violations Noted On 10/30/2013, I conducted an inspection of the Chevron Appalachiaï¾’s Hamborsky 12 - 13H unit wells in Bullskin Twp., Fayette County.

The site hs a Act 9 sign up a the entrance of the site. The mailbox at the ID sign contained the E&S plan and well permits.

The access road was in good shape and had a gate that was locked.

Both wells were labeled and were hooked up to production.

Two brine tanks are on site and are located inside secondary containment. The flow line to the two heater/separator units are underground. No leaks were observed.

The site area has been reclaimed and has good growth on it except where the sed traps used to be located. The small gullies and wash outs observed in Septmeber have been removed, but there are areas of no growth in the old sed trap locations. The area of the old access road to the sed traps is also lacking the 70% uniform vegetative growth.

The site looks to be stable.

2223621 2013-11-20 No Violations Noted On 11/20/2013, the Department conducted an Notice of Termination inspection at the Chevron Appalachiaï¾’s Hamborsky 12 - 13H unit well site in Bullskin Twp., Fayette County. The NOT inspection is being done for ESCGP permit ESX09-051-0044.

The site had an Act 9 ID sign up at the entrance to the access road. The mailbox at the ID sign contained the E&S plan and well permits.

The access road was in good shape and was gated and locked.

There are two tanks on site located inside containment. There are two heater/separator units on site. Both wells were labeled. No leaks were observed today.

The site has been reclaimed and all drilling equipment and supplies not needed for production have been removed.

The vegetation on the reclaimed site looks good.

The NOT is approved but it is suggested that the Operator check the vegetative growth in the Spring of 2014, in the area where the sed traps were reclaimed to be sure it continues to have the required 70% uniform coverage.

For data sources see[3]

References