X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-31304

Well Details

Well ID: 37-005-31304
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Boggs Township
Operator Name: SNYDER BROS INC
Well Pad ID: 154069
Farm/Lease Name: KUHNS
License Status:
Spud Date:
Permit Date: 2017-10-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.913972
Longitude: -79.373150

For data sources see[1][2][3]

Well History

Date Event
2017-10-11 New Permit Application
2018-03-15 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-09-04 2018-09-21 6,728 12,904,500 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand US Silica/RW Elliot/Unimin Proppant Silica Substrate 14808-60-7 100 10.599 12,865,100.0
Other Chemical(s) Listed Above See Trade Name(s) List Alcohols, C12-15 Branched/Linear, Ethoxylated Propoxylated 120313-48-6 5 0.00264314 3208.24
Quaternary ammonium compounds,
benzylC12-16-alkyldimethyl, chlorides
68424-85-1 2.5 0.000224679 272.716
Water 7732-18-5 85 0.506656 614979
Poly(oxy-1,2-ethanediyl), a-(4-nonylphenyl)-w-hydroxy-branche
d
127087-87-0 3 0.00158588 1924.94
Thiourea 62-56-6 1 0.00000512 6.215
Formaldehyde 50-00-0 1 0.00000512 6.215
Water 7732-18-5 83 0.00745936 9054.16
Acetophenone 98-86-2 1 0.00000512 6.215
Methanol 67-56-1 5 0.00002560 31.076
Ethanol 64-17-5 0.3 0.00002696 32.726
Ethoxylated alcohol 68002-97-1 35 0.000179216 217.532
Aqucar 714 The Dow Chemical Company Microbiocide Water 7732-18-5 83 0.00745936 9054.16
Quaternary ammonium compounds,
benzylC12-16-alkyldimethyl, chlorides
68424-85-1 2.5 0.000224679 272.716
Ethanol 64-17-5 0.3 0.00002696 32.726
Glutaraldehyde 111-30-8 14 0.0012582 1527.21
Unislick E Flotek Chemistry, LLC Friction Reducer Petroleum distillates, hydrotreated light 64742-47-8 30 0.00395181 4796.71
Unihib G GeoSafe Acid Inhibitor Acetophenone 98-86-2 1 0.00000512 6.215
Formaldehyde 50-00-0 1 0.00000512 6.215
Ethoxylated alcohol 68002-97-1 35 0.000179216 217.532
Methanol 67-56-1 5 0.00002560 31.076
Thiourea 62-56-6 1 0.00000512 6.215
Short Chained Glycol Ether 112-34-5 60 0.000307228 372.913
FR-1 SNF Inc Friction Reducer Petroleum distillates, hydrotreated light 64742-47-8 30 0.0158588 19249.4
Poly(oxy-1,2-ethanediyl), a-(4-nonylphenyl)-w-hydroxy-branche
d
127087-87-0 3 0.00158588 1924.94
Alcohols, C12-15 Branched/Linear, Ethoxylated Propoxylated 120313-48-6 5 0.00264314 3208.24
Water Snyder Brothers Carrier/Base Fluid Water 7732-18-5 100 88.7198 107,688,000.0
Scale Hib PE-18 Universal Pressure Pumping, Inc Scale Inhibitor Proprietary Scale Inhibitor PROPRIETARY 30 0.00286027 3471.79
Hydrochloric Acid (15%) PVS Acidizing Water 7732-18-5 85 0.506656 614979
Hydrochloric Acid 7647-01-0 15 0.0894099 108526

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2018 SNYDER BROS INC 43,384.00 7 0.00 0 0.00 0
2019 SNYDER BROS INC 1,396,207.00 330 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 SNYDER BROS INC Synthetic Liner Materials 5.32 Tons LANDFILL 100585
2018 SNYDER BROS INC Drill Cuttings 1,351.90 Tons LANDFILL 100585
2018 SNYDER BROS INC Produced Fluid 10,279.50 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018 SNYDER BROS INC Produced Fluid 400.50 Bbl INJECTION DISPOSAL WELL 34-155-24079
2018 SNYDER BROS INC Produced Fluid 61.47 Tons LANDFILL 100594
2018 SNYDER BROS INC Produced Fluid 5.73 Tons LANDFILL 100585
2019 SNYDER BROS INC Produced Fluid 14,148.50 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019 SNYDER BROS INC Produced Fluid 568.50 Bbl INJECTION DISPOSAL WELL 34-099-23171
2019 SNYDER BROS INC Filter Socks 2.10 Tons LANDFILL 100585
2019 SNYDER BROS INC Synthetic Liner Materials 3.73 Tons LANDFILL 100585
2019 SNYDER BROS INC Produced Fluid 3,412.90 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2707353 Primary Facility 2018-03-20 Drilling/Alteration No Violations Noted This well has a 6' cellar. The well was spudded to 40' with a 36" bit. The operator ran 40' of 30" conductor pipe and cemented it in using 5.5 yards of class A cement. There was no water encountered in the cellar. The cellar is covered over with a piece of steel plate for safety until the top hole drilling rig arrives to drill. All required paperwork is on site and the equipment on site looks ok.
2707394 Primary Facility 2018-03-20 Routine/Partial Inspection No Violations Noted Inspection conducted in response to spud notifications for wells 3H, 4H, and 5H.

At time of inspection, well 5H drilled to 40 feet and covered with steel plate. Wells 3H and 4H drilled to 40 feet and covered with steel plates. Wells 1H and 2H drilled and frac'd.

Department unable to adequately inspect the entire location due to ongoing high pressure testing occurring on part of the well pad.

2724442 Primary Facility 2018-04-18 Routine/Partial Inspection No Violations Noted At time of inspection, well 5H spudded, not yet completed, covered with steel plate. Wells 3H and 4H spudded, not yet completed, covered with steel plates. Wells 1H and 2H drilled and frac'd.
2736985 Primary Facility 2018-06-04 Drilling/Alteration No Violations Noted This well has a 6' cellar. The well was spudded to 40' with a 36" bit. The operator ran 40' of 30" conductor pipe and cemented it in using 5.5 yards of class A cement. There was no water encountered in the cellar. The rig was just starting to drill the 20" hole section at the time of this inspection. All required paperwork is on site and the equipment on site looks ok.
2738710 Primary Facility 2018-06-07 Drilling/Alteration No Violations Noted This well has a 6' cellar. The well was spudded to 40' with a 36" bit. The operator ran 40' of 30" conductor pipe and cemented it in using 5.5 yards of class A cement. There was no water encountered in the cellar. The rig Drilled to 895', set 875' of 13 3/8" pipe and cemented with 687 sks of cement and saw a 30 bbl return on cement. At the time of this inspection the rig was nippling up to drill the intermediate 12 3/8' section of the hole. All required paperwork is on site and the equipment on site looks ok.
2739609 Primary Facility 2018-06-11 Drilling/Alteration No Violations Noted This well has a 6' cellar. The well was spudded to 40' with a 36" bit. The operator ran 40' of 30" conductor pipe and cemented it in using 5.5 yards of class A cement. There was no water encountered in the cellar. The rig Drilled to 895', set 875' of 13 3/8" pipe and cemented with 687 sks of cement and saw a 30 bbl return on cement. The rig drilled and set 1972' of 9 5/8" casing and cemented with 591 sks cement and saw a 28 bbl return.

At the time of this inspection the rig was drilling at 3837'. All required paperwork is on site and the equipment on site looks ok.

2742397 Primary Facility 2018-06-18 Drilling/Alteration No Violations Noted This well has a 6' cellar. The well was spudded to 40' with a 36" bit. The operator ran 40' of 30" conductor pipe and cemented it in using 5.5 yards of class A cement. There was no water encountered in the cellar. The rig Drilled to 895', set 875' of 13 3/8" pipe and cemented with 687 sks of cement and saw a 30 bbl return on cement. The rig drilled and set 1972' of 9 5/8" casing and cemented with 591 sks cement and saw a 28 bbl return.

At the time of this inspection the rig was stacked at the edge of the location and the top hole portion of the well was drilled and waiting on the big rig. All equipment on site looked ok.

2743286 Primary Facility 2018-06-13 Routine/Partial Inspection No Violations Noted At time of inspection, drilling rig currently on-site. Wells 3H, 4H, and 5H previously spudded, not yet frac'd. Wells 1H and 2H drilled and frac'd.
2755217 Primary Facility 2018-07-24 Drilling/Alteration No Violations Noted At the time of this inspection the Rig had finished drilling this well to a TD of 13,250' and was being moved off location. The crew had put down a coat of water for dust control and the road and all equipment looked ok.
2770806 Primary Facility 2018-09-05 Drilling/Alteration No Violations Noted The fracking contractor Universal Well Services was fracking stage 2 at the time of my inspection. All paperwork and equipment on site looked ok.
2782469 Primary Facility 2018-10-02 Drilling/Alteration No Violations Noted The rig was drilling out frac plugs on this well at the time of this inspection. All paperwork, well log information and equipment on site looked ok.
2818059 Primary Facility 2018-12-17 Routine/Complete Inspection No Violations Noted At time of inspection well appears to be in production. Well head surrounded by cement barriers. Three brine tanks on site.

No activity taking place on site at this time.

2823181 Primary Facility 2019-01-08 Routine/Complete Inspection No Violations Noted This well is tagged, in production and temporarily shut in for a sales line upgrade which is taking place at the time of this inspection in order to provide additional pipeline capacity for the 5 wells on this unconventional well pad. The well head casing, piping, production set equipment, containment dike and tank battery look ok.
2828396 Primary Facility 2019-01-17 Routine/Complete Inspection No Violations Noted On 1/17/19 at 0903 hrs., I conducted a routine inspection of Snyder Brothers, Inc.'s Kuhns well pad and associated wells in Boggs Twp., Armstrong Co. Five wells have been drilled and are equipped for production, including well 5H (API 005-31304). Well tags are present at the well heads. There are no violations noted for this inspection.
2853273 Primary Facility 2019-03-05 Routine/Partial Inspection No Violations Noted At the time of inspection, well was producing. Well integrity was in good condition, with no signs of any leaks or spills onsite. The well did not have any corrosion. The cellar was below ground level, with water inside. No bubbles were seen. The digital gauges on the well showed the tubing pressure to be 2345 psi and the casing pressure was 2663 psi. The well was properly labeled and the Emergency Response sign was posted at the site entrance. There were 3 dual line heaters and 5 separators onsite. The 1H & 2H wells had smaller separators than the rest of the wells. There were also 3 tall tanks and a smaller horizontal tank contained within a lined, steel dike.

For data sources see[8]

References