37-005-31302

Well Details

Well ID: 37-005-31302
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Boggs Township
Operator Name: SNYDER BROS INC
Well Pad ID: 154069
Farm/Lease Name: KUHNS
License Status:
Spud Date:
Permit Date: 2017-10-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.913975
Longitude: -79.373294

For data sources see[1][2][3]

Well History

Date Event
2017-10-11 New Permit Application
2018-03-15 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-09-04 2018-09-18 6,689 10,447,600 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid (15%) PVS Acidizing Water 7732-18-5 85 0.447523 441502
Hydrochloric Acid 7647-01-0 15 0.0789746 77912.1
Water Snyder Brothers Carrier/Base Fluid Water 7732-18-5 100 88.3741 87,185,100.0
Unihib G GeoSafe Acid Inhibitor Thiourea 62-56-6 1 0.00000452 4.457
Ethoxylated alcohol 68002-97-1 35 0.000158139 156.011
Formaldehyde 50-00-0 1 0.00000452 4.457
Short Chained Glycol Ether 112-34-5 60 0.000271095 267.448
Acetophenone 98-86-2 1 0.00000452 4.457
Methanol 67-56-1 5 0.00002259 22.287
Other Chemical(s) Listed Above See Trade Name(s) List Alcohols, C12-15 Branched/Linear, Ethoxylated Propoxylated 120313-48-6 5 0.00232757 2296.25
Poly(oxy-1,2-ethanediyl), a-(4-nonylphenyl)-w-hydroxy-branche
d
127087-87-0 3 0.00139654 1377.75
Methanol 67-56-1 5 0.00002259 22.287
Thiourea 62-56-6 1 0.00000452 4.457
Ethanol 64-17-5 0.3 0.00006813 67.214
Formaldehyde 50-00-0 1 0.00000452 4.457
Water 7732-18-5 83 0.0188494 18595.8
Water 7732-18-5 85 0.447523 441502
Ethoxylated alcohol 68002-97-1 35 0.000158139 156.011
Acetophenone 98-86-2 1 0.00000452 4.457
Quaternary ammonium compounds,
benzylC12-16-alkyldimethyl, chlorides
68424-85-1 2.5 0.000567753 560.114
Sand US Silica/RW Elliot/Unimin Proppant Silica Substrate 14808-60-7 100 10.998 10,850,000.0
FR-1 SNF Inc Friction Reducer Alcohols, C12-15 Branched/Linear, Ethoxylated Propoxylated 120313-48-6 5 0.00232757 2296.25
Poly(oxy-1,2-ethanediyl), a-(4-nonylphenyl)-w-hydroxy-branche
d
127087-87-0 3 0.00139654 1377.75
Petroleum distillates, hydrotreated light 64742-47-8 30 0.0139654 13777.5
Aqucar 714 The Dow Chemical Company Microbiocide Ethanol 64-17-5 0.3 0.00006813 67.214
Quaternary ammonium compounds,
benzylC12-16-alkyldimethyl, chlorides
68424-85-1 2.5 0.000567753 560.114
Glutaraldehyde 111-30-8 14 0.00317942 3136.64
Water 7732-18-5 83 0.0188494 18595.8
Scale Hib PE-18 Universal Pressure Pumping, Inc Scale Inhibitor Proprietary Scale Inhibitor PROPRIETARY 30 0.00294149 2901.92
Unislick E Flotek Chemistry, LLC Friction Reducer Petroleum distillates, hydrotreated light 64742-47-8 30 0.00658264 6494.08

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2018 SNYDER BROS INC 188,149.00 42 0.00 0 0.00 0
2019 SNYDER BROS INC 875,110.00 336 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 SNYDER BROS INC Synthetic Liner Materials 5.30 Tons LANDFILL 100585
2018 SNYDER BROS INC Drill Cuttings 867.23 Tons LANDFILL 100585
2018 SNYDER BROS INC Produced Fluid 8,532.70 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018 SNYDER BROS INC Produced Fluid 332.40 Bbl INJECTION DISPOSAL WELL 34-155-24079
2018 SNYDER BROS INC Produced Fluid 51.01 Tons LANDFILL 100594
2018 SNYDER BROS INC Produced Fluid 4.76 Tons LANDFILL 100585
2019 SNYDER BROS INC Produced Fluid 11,744.30 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019 SNYDER BROS INC Produced Fluid 471.80 Bbl INJECTION DISPOSAL WELL 34-099-23171
2019 SNYDER BROS INC Filter Socks 2.20 Tons LANDFILL 100585
2019 SNYDER BROS INC Synthetic Liner Materials 3.74 Tons LANDFILL 100585
2019 SNYDER BROS INC Produced Fluid 2,833.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2707347 Primary Facility 2018-03-20 Drilling/Alteration No Violations Noted This well has a 6' cellar. The well was spudded to 40' with a 36" bit. The operator ran 40' of 30" conductor pipe and cemented it in using 5.5 yards of class A cement. There was no water encountered in the cellar. The cellar is covered over with a piece of steel plate for safety until the top hole drilling rig arrives to drill. All required paperwork is on site and the equipment on site looks ok.
2707392 Primary Facility 2018-03-20 Routine/Partial Inspection No Violations Noted Inspection conducted in response to spud notifications for wells 3H, 4H, and 5H.

At time of inspection, well 3H drilled to 40 feet and covered with steel plate. Wells 4H and 5H drilled to 40 feet and covered with steel plates. Wells 1H and 2H drilled and frac'd.

Department unable to adequately inspect the entire location due to ongoing high pressure testing occurring on part of the well pad.

2724449 Primary Facility 2018-04-18 Routine/Partial Inspection No Violations Noted At time of inspection, well 3H spudded, not yet completed, covered with steel plate. Wells 4H and 5H spudded, not yet completed, covered with steel plates. Wells 1H and 2H drilled and frac'd.
2732749 Primary Facility 2018-05-22 Drilling/Alteration No Violations Noted This well has a 6' cellar. The well was spudded to 40' with a 36" bit. The operator ran 40' of 30" conductor pipe and cemented it in using 5.5 yards of class A cement. There was no water encountered in the cellar. The rig ran 152' of 20", cemented with 337 sks of cement and saw a 7 bbl return on cement. Drilled to 890', ran 888' of 13 3/8" pipe, cemented it with 691 sks of cement and saw a 31 bbl return on cement. The Rig had drilled to 2006', ran 1986' of 9 5/8" casing and was getting ready to cement at the time of this inspection. The drilling log information and all equipment on site looked ok.
2743290 Primary Facility 2018-06-13 Routine/Partial Inspection No Violations Noted At time of inspection, drilling rig currently on-site. Wells 3H, 4H, and 5H previously spudded, not yet frac'd. Wells 1H and 2H drilled and frac'd.
2748144 Primary Facility 2018-07-03 Drilling/Alteration No Violations Noted On this date the Patterson rig has been set up, the BOP has just been tested and the crew was getting ready to start drilling. All equipment on site looked ok.
2818053 Primary Facility 2018-12-17 Routine/Complete Inspection No Violations Noted At time of inspection well appears to be in production. Well head surrounded by cement barriers. Three brine tanks on site.

No activity taking place on site at this time.

2823170 Primary Facility 2019-01-08 Routine/Complete Inspection No Violations Noted This well is tagged, in production and temporarily shut in for a sales line upgrade which is taking place at the time of this inspection in order to provide additional pipeline capacity for the 5 wells on this unconventional well pad. The well head casing, piping, production set equipment, containment dike and tank battery look ok.
2828387 Primary Facility 2019-01-17 Routine/Complete Inspection No Violations Noted On 1/17/19 at 0903 hrs., I conducted a routine inspection of Snyder Brothers, Inc.'s Kuhns well pad and associated wells in Boggs Twp., Armstrong Co. Five wells have been drilled and are equipped for production, including well 3H (API 005-31302). Well tags are present at the well heads. There are no violations noted for this inspection.
2853263 Primary Facility 2019-03-05 Routine/Partial Inspection No Violations Noted At the time of inspection, well was producing. Well integrity was in good condition, with no signs of any leaks or spills onsite. The well did not have any corrosion. The cellar was below ground level, with water inside. No bubbles were seen. The digital gauges on the well showed the tubing pressure to be 1707 psi and the casing pressure was 2015 psi. The well was properly labeled and the Emergency Response sign was posted at the site entrance. There were 3 dual line heaters and 5 separators onsite. The 1H & 2H wells had smaller separators than the rest of the wells. There were also 3 tall tanks and a smaller horizontal tank contained within a lined, steel dike.

For data sources see[8]