If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-115-24337 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.6789364614,"lon":-81.7537469097,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1993-06-29 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 7 | |
Latitude: 39.6789364614 | |
Longitude: -81.7537469097 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1078015490 | 2013-11-25 | Compliance Action Follow-up -977515138: I called and talked to Bob Masters and he stated he will get the gas contract from Artex within the next week and should have the wells on line in the next 30-60 days. He will call when the wells are in production. | ||||
-1675490538 | 2003-12-17 | Well is in compliance to NOV issued 4/7/03 for non production and ID well was recently reworked by Century Well Service for Ohio Energy Asetts(Nancy Melville) then DaveAtha was going to have well transferred to his bond. | ||||
-1800868868 | 2014-03-31 | Compliance Action Follow-up -977515138: The well is still shut in and there is an old chart on the meter in the dike. I called and left a message with Bob Masters explaining that the well needs to be in commercial production or it will be sent to supervisor for legal review. There was also a leak in Artex's transmission line near their gas meter. I relayed the info to Jason Ritchie and John Schneider. | ||||
-1994296951 | 2003-12-17 | Restoration complete | ||||
-610382174 | 2013-12-02 | Compliance Action Follow-up -977515138: The well is shut in and waiting on gas contract with Artex. Bob Masters will call when well is back in commercial production. | ||||
-812823721 | 2003-10-21 | stopped by service rig for update they were at 3600' trying to knock out bridge plugs | ||||
-977515138 | 2013-07-03 | Upon inspection, I found well to be shut in. Inspector, Dave Ball accompanied me at this well. The dike was overgrown with vegetation and there was no chart in the meter. The wellhead had H2S scaling and odor, and there appeared to be a leak in the surface casing head. I spoke with Bob Atha and he stated they will have someone out there soon to take care of the issues. He said the well was in the process of being transferred over to someone with Cortland Energy. Operator must fix wellhead leak and operator must make well capable of production within 30 days; or plugging is required in 30 days. | 9-9-05(A)1 | |||
-977515138 | 2013-07-03 | Upon inspection, I found well to be shut in. Inspector, Dave Ball accompanied me at this well. The dike was overgrown with vegetation and there was no chart in the meter. The wellhead had H2S scaling and odor, and there appeared to be a leak in the surface casing head. I spoke with Bob Atha and he stated they will have someone out there soon to take care of the issues. He said the well was in the process of being transferred over to someone with Cortland Energy. Operator must fix wellhead leak and operator must make well capable of production within 30 days; or plugging is required in 30 days. | NONE | |||
-977515138 | 2013-07-03 | Upon inspection, I found well to be shut in. Inspector, Dave Ball accompanied me at this well. The dike was overgrown with vegetation and there was no chart in the meter. The wellhead had H2S scaling and odor, and there appeared to be a leak in the surface casing head. I spoke with Bob Atha and he stated they will have someone out there soon to take care of the issues. He said the well was in the process of being transferred over to someone with Cortland Energy. Operator must fix wellhead leak and operator must make well capable of production within 30 days; or plugging is required in 30 days. | NONE_ | |||
1050031450 | 2003-04-07 | found well to be idle will issue N.O.V. #30103 Slight leak at tubing head,no production reported since 1998.No I.D. on tanks or at wellhead
|
9-9-05(A)1 | |||
1050031450 | 2003-04-07 | found well to be idle will issue N.O.V. #30103 Slight leak at tubing head,no production reported since 1998.No I.D. on tanks or at wellhead
|
NONE | |||
1055164838 | 2003-06-09 | non-compliance to NOV#30103
Recommend chiefs order |
||||
1066493933 | 2003-10-17 | stopped by service rig for update on plugging Centry Well Service on location tubing pulled 3600'+or- waiting on more tubing well is 7250'+or-they are going in hole with sand line drill to knock out bridge plugs. | ||||
1068509934 | 2003-11-06 | stopped by service rig for up-date on plugging status rig was @6956'awaiting orders from co.rep
Iwas told that Dave Atha was going to put well back into production,advised him to get well transferred on to his companys bond. |
||||
1089499062 | 2004-07-07 | No violations noted on the day of my inspection,stopped by site to check restoration of pitsite due to fact of recent work preformed at site. Pit was filled in and restoration satisfactory. | ||||
1099492711 | 2004-11-02 | No violations noted on the day of my inspection,well was pumping during my inspection. | ||||
1399040301 | 2014-05-02 | Bob Masters with Cortland Energy called and stated that Artex was completing the gas contract this week in order for them to sell gas off of this well. He stated that Joe Schneider, of Artex, required everything to be in working order. They plan on charging the system with an Amine solution in order to deal with the H2S and should have the well in production within 6 weeks. He will continue to keep me posted as the work to getting the well back into commercial production. | ||||
1475491394 | 2003-12-18 | Restoration passed. | ||||
1527977082 | 2003-04-07 | FOLLOW UP TO NOV # 1050031450 found well to be idle will issue N.O.V. #30103 Slight leak at tubing head,no production reported since 1998.No I.D. on tanks or at wellhead
Well is producingfrom Beekmantown formation.
In reference to Mr. VanHorn's complaint. |
9-9-05(A)1 | |||
1527977082 | 2003-04-07 | FOLLOW UP TO NOV # 1050031450 found well to be idle will issue N.O.V. #30103 Slight leak at tubing head,no production reported since 1998.No I.D. on tanks or at wellhead
Well is producingfrom Beekmantown formation.
In reference to Mr. VanHorn's complaint. |
NONE | |||
785415685 | 2013-09-05 | Compliance Action Follow-up -977515138: There has been no resolution to any of the issues. Tanks have been painted and there is a new motor on pumpjack, however well is shut in and the 4.5" lines are disconnected at the wellhead. Well tender, John Pryor, stated the well has issues and they had a hard time getting the unit to pump. I talked with Bob Masters and he was unaware that there was a compliance action on the well. He said they are doing everything they can to get the well back in production, and that he needs to secure enough money to get a service rig on location. He asked for an extension in order to get resolution to the issues. |