X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-093-21236

Well Details

Well ID: 34-093-21236
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1985-01-04
Unconventional:
Horizontal:
Producing: No
Violations: 10
Latitude: 41.326241674
Longitude: -81.994511616

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1475774975 2014-06-27 An inspection of the well and injection facility found no violations.
-150311222 2013-03-29 My inspection of the injection well and surface facility found no violations.
-1565146590 2005-10-20 FAILURE TO SUBMIT ANNUAL SALWATER INJECTION WELL REPORTS 9-3-07(E)
-1743232022 2004-02-05 No violations at site.Clean operation. 22 degrees, cloudy
-1804624156 2010-05-27 Well in compliance. Injection on vacuum.
-371666281 2007-02-07 Inspected injection and annulus pressure. Both readings are 0psi. Annual reports are delinquent since 10-20-2005. Called Gary Staggs to advise to update annual reports with Tom Tomastic. Annular pressure needs a mini-test on packer due to 0 psi. Gave 30 days to complete. Sun, 7 degrees. 9-3-04(B)
-371666281 2007-02-07 Inspected injection and annulus pressure. Both readings are 0psi. Annual reports are delinquent since 10-20-2005. Called Gary Staggs to advise to update annual reports with Tom Tomastic. Annular pressure needs a mini-test on packer due to 0 psi. Gave 30 days to complete. Sun, 7 degrees. 9-3-05(B)4
-372370045 2003-08-25 No violations sunny 75 degrees. Clean around well and inside dike. Well on vacume.
-415175895 2010-08-05 Inspect well and facility. No violations.
-489358385 2009-09-22 Tubing has been repaired and brine leak is corrected. NOV in compliance. Cloudy, 70 degrees.
-655749272 2013-09-25 There were no violations found at the time of my inspection.
-782495754 2009-01-22 100 barrel tank has been removed. MIT annulus. Pressured up annulus to 165 psi and tested for 15 minutes. Pressure dropped to 160 psi. Advised Gary Staggs to have larger compressor and check fluid level in annulus on next test. 20 degrees, sunny.
1037731972 2002-11-19 Well is on vacume. No pressure at this time on tubing or annulus. Well and loading area are clean. No violations. Rain,windy 40 degrees.
1055857212 2003-06-17 No violations. Cloudy 70 degrees. NOV of 12-6-2001 in compliance.
1070478377 2003-12-03 No violations, sunny 35 degrees.
1096036956 2004-09-24 Well is in operation with 3-210 and 2-100 barrel tanks in battery. Area is clean. Sun, 70 degrees.
1107795727 2005-02-07 Inspect facility and well. Truck unloading brine. No violations. Advised Gary Staggs injection packer needs tested. Set up date. Well is on vacume. Clean operation. Cloudy, 50 degrees.
1109271251 2005-02-24 MIT test on annulus. Pumped on annular space between injection tubing and 4.5" casing several times and did not build pressure. Advised S&H Water Service to install new valves and pump minimum of 200 psi on annulus. Injection tubing is on vacume. Fluid level in annulus is at ground level. 9-3-04(B)
1109860033 2005-03-03 Constucted new pressure valves and gauges on annulus between injection tubing and production casing. Put 200 psi on annulus on 3-2-2005. Reading on 3-3-2005 is 15 psi. Pump annular pressure to 200 psi and re- test annulus. After 15 minutes 0 decline in pressure. NOV in compliance. 9-3-04(B)
1157636511 2006-09-07 Well in operation. Truck unloading during inspection. No violations. Sun, 65 degrees.
1175173768 2007-03-29 Mini test on annulus is approved. Pressured up on packer at 200 psi and held for 15 minutes. Annual injection reports are updated with Tom Tomastic. NOV in compliance. Sun ,40 degrees.
1200062698 2008-01-11 Inspect annulus pressure on well. Holding at 70 psi. Operator pumped annular side to 200 psi on 01-08-2008. Pressure has dropped 130 psi in 3 days. I will continue to monitor packer pressure. Tubing is on vacume.
1215183630 2008-07-02 Quarterly inspection. Site is active and no violations at this time. Sun, 70 degrees.
1220i173 2002-03-20 Well is on vacume at this time. Inside Dike is clean and no oder of crude oil. 40 degrees and raining at time of inspection. A 300 barrel storage tank and two service rigs are stored 100' from well. Well site is in compliance with 1509.
1220i70 2001-07-18 Repair electric box to sump pump. Lime 10' x 20' area north of dike. Brine leak has been repaired. 9-3-07(H)
1220i98 2001-10-02 ELECTRIC SWITCH IS REPAIRED ADVISED GARY STAGGS TO REMEDIATE BRINE SCALD AREA. 9-3-05(A)6
1223476134 2008-10-08 Inspection of well and facility. No violations. Noticed injection tubing is holding 50 psi. Normally on vacume. Rain, 65 degrees.
1231262824 2009-01-06 Complaint called by Zoning Inspector Keith Tolbert of Eaton township, Lorain county. Met with Mr. Tolbert on site and inspected facility and well. Citizens are complaining of odor, noise, and truck traffic. Township zoning stated a permit was not issued to have an injection facility in Eaton township. I advised him to refer to HB 278/299. I advised S&H to remove 100 barrel tank from outside dike. Pump up annulus to 200 psi and call for test. 9-5-09[C]
1239209710 2009-04-08 Check annulus pressure and quarterly inspection. No violations at this time. Sun, 45 degrees.
1248193783 2009-07-21 No violations at facility or well. Replaced injection line from well to pump. Very well maintained. Sun, 80 degrees.
1264091556 2010-01-21 No violations at this time. Truck unloading brine.
1271776201 2010-04-20 Well is in operation. Pump running and injecting fluid at 20 psi. No violations. Sun, 50 degrees.
1285764271 2010-09-29 Injection in operation. Replaced 2-210 barrel and 2-100 barrel brine storage tanks inside dike area. New paint on all tanks. No violations. Sun, fog, 50 degrees.
12878812 2001-12-06 Grass growing in scald area. Well in compliance.
1296832183 2011-02-04 Well is in operation. Trucks unloading brine. No violations at this time. Advised Leroy Gibert to pump up annulus pressure to 200 psi. Sun, 20 degrees.12 snow on ground.
1302219870 2009-09-09 During inspection located a brine leak at well under tubing valve. Called Leroy Gilbert and he advise me to shut flow valve and pump would shut down. Leak has stopped. Scheduled to have repaired 9-10-2009. 9-3-07(H)
1541829851 2007-12-27 Inspect well and tank battery. Well tubing is on vacume and annular side reads 0 psi. Called Leroy Gilbert to schedule a test on packer. I advised him to pressure annular side to 200 psi. Call when ready for test. Cloudy, 40 degrees
2019044091 2012-07-13 My inspection of the well and injection facility found no violations.
299845525 2005-10-20 FOLLOW UP TO NOV # -1565146590 FAILURE TO SUBMIT ANNUAL SALWATER INJECTION WELL REPORTS 9-3-07(E)
302118459 2006-05-16 Quarterly inspection of facility and well. Met with Roy Gilbert on site.Unloaded 70 barrels of brine. No violations at facility but reminded company brine injection reports are due. Well remains on vacume. Rain, 60 degrees.
333045039 2006-02-16 No violations at site or well. Clean operation. Well is on vacume. Well and storage facility are fenced. Rain, 45 degrees.
474916201 2014-03-31 The were no violations found at the time of inspection.
600473038 2005-09-14 No violations at well or dumping site. Area is maintained very well. Annular gauge reads 75 psi. Tubing is on vacume. Sun, 80 degrees.
PL13360 Preliminary Restoration done information from Data Point
UIC1110 1991-06-21 1501:9-3-07 (E) & (F) 1ST.QTR.1991 RPT.
UIC1744 1998-11-10 1509.22 STORAGE & DISPOSAL