X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-22121

Well Details

Well ID: 34-055-22121
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2010-09-04
Unconventional:
Horizontal:
Producing: No
Violations: 0
Latitude: 41.5156224126
Longitude: -81.3485983751

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1094898692 2010-09-04 The conductor pipe was installed and cemented. All conditions were satisfactory.
-1882905779 2010-09-05 Surface casing was installed and cemented. Adequate cement returns were observed. Cement operation met all requirements.
-391689665 2012-01-04 Well and battery are in good repair and all man doors are locked. An identification sign needs posted.
-831195134 2010-10-08 Operator was flowing well back. Site was in good repair. Lease road was stable. Pits were closed. Bull plugs were in frac Tanks.
-833779958 2011-07-13 Well is a rabbit well, the catcher is red in color. Zero psi on the annulus. Locks on load lines. Identification is posted. Valve on dike drain. 2 100Bbl production tanks 1500 gallon poly tank and a mechincal separator are in the battery. Lease road is stable. Locks on man doors. Spacing is correct.
1286378280 2010-10-05 Frac crew was moving off site. Frac job per the operator went well. Operator submitted Bond/cement log for the GCC#2. The 5 day annulus test result was 66psi. Lockport Top is 3114 top of the cement is 3050. Operator has 64' of coverage above the Lockport.
1973566843 2013-05-28 My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open and plumbed into a pop off valve that is plumbed into the production tank. The tank battery and well are in good repair and surrounded by a chain link fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL poly brine tank, and a mechanical separator. The vent stack on the production tank is plumbed into a 55 gallon charcoal filter. The vent stack is then plumbed up and topped with a spark arrestor. The proper identification is located on the tank battery. The lease road is in stable condition.