34-035-21910

Well Details

Well ID: 34-035-21910
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2006-11-30
Unconventional:
Horizontal:
Producing: No
Violations: 0
Latitude: 41.5154539752
Longitude: -81.4107203872

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-2034643203 2006-11-22 drilling
-261264215 2007-12-12
-653927922 2006-11-30 surface
-731576880 2014-06-18 I inspected this producing unit as part of regular site check and inspection activity. The well was completed in 07/06/2007. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger lift system. The wellhead is located in a closed and locked board-on-board enclosure. The 8.625-inch casing is valved to surface but is not gauged. There are no signs of leakage or problems at the wellhead. The aboveground storage tank battery is located southeast and adjacent to the wellhead. The battery is comprised of 1 steel 100-barrel production tank, 1 50-barrel poly brine tank, and a horizontal separator. The battery is located in a separate board-on-board enclosure which is gated and locked. The load-outs are bull-plugged and locked. There is process safety equipment in use (carbon filter, low-pressure relief valve, and spark arrestor). The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery and wellhead which are legible and in good condition. The area of the well is generally level with a rapid topographic drop to the south and east towards the Chagrin River which lies approximately 1/4 mile to the east. I did not observe any signs of gully formation or washouts. Access to the unit is afforded by a dedicated gravel-paved access road which is partially shared with the Oppmann residence The short access road is currently in good condition and free of washout or erosional deficits. Beyond the area cleared for the wellhead and tank battery, the areas surrounding the unit are heavily wooded with one single-family residential home bordering to the northwest, and no other residential structures within eyesight.
-881834633 2007-01-31
1063877537 2008-05-20
1371818208 2006-11-30 set surface