X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-019-22579

Well Details

Well ID: 34-019-22579
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date:
Unconventional:
Horizontal:
Producing:
Violations:
Latitude:
Longitude:

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1234398146 2014-06-23 I was on location for the cementing of the intermediate casing. Nomac Rig 74 drilled a 12.25" Hole #3 to 2,525' from rig floor (KB) and set 9.625" casing to 2,510' KB with 15 centralizers. The rig floor height was 20'. The casing had a weight of 40 lbs/ft and rating of J-55. A float shoe and collar was installed on the casing. The float collar was between the second and third joints. Schlumberger rigged up and established circulation with 5 bbls of fresh water. The operator mixed and pumped 25 bbls of a gel spacer, 10 bbls of a water spacer and 197 bbls (900 sacks) of Class A cement with a yield of 1.23 and 15.6 PPG. Next, Schlumberger released the plug and displaced the cement to 2,421' with 183.5 bbls of fresh water. I witnessed 35 bbls of good cement returned to surface. Once the plug landed, O-Tex pressured up from 1,068 psi to 1,579 psi and held static for 5 minutes. Pressure on the plug was release and there was 1 bbl of flow back water.
1403634576 2014-06-21 I was on location for the cementing of the surface casing. Nomac Rig 74 drilled a 17.5" Hole #2 to 572' from rig floor (KB) and set 13.375" casing to 557' KB with 5 centralizers. The casing had a weight of 54.5 lbs/ft and rating of J-55. A float shoe and collar was installed onto the casing string. Schlumberger rigged up and established circulation with 5 bbls of fresh water. The operator mixed and pumped 30 bbls of a gel spacer, 10 bbls of a fresh water spacer and 109 bbls (500 sacks) of Class A cement with a yield of 1.22 and 15.6 PPG. Next, Schlumberger released the plug and displaced the cement to 514' with 79.5 bbls of fresh water. I witnessed 25 bbls of good cement returned to surface. Once the plug landed, O-Tex pressured up from 300 to 1300 psi and held static for 5 minutes. Pressure on the plug was release and there was 0.5 bbl of flow back water. Cement samples was taken and weighed at 15.6.
1897889412 2014-04-27