{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
− | | Well ID: 37- | + | | Well ID: 37-035-21226 |
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 41.224586, -77.998044 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 9: | Line 9: | ||
| State: Pennsylvania | | State: Pennsylvania | ||
|- | |- | ||
− | | County: [[ | + | | County: [[Clinton_County,_Pennsylvania|Clinton]] |
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[West Keating Township,_Clinton_County,_Pennsylvania|West Keating Township]] |
|- | |- | ||
− | | Operator Name: [[ | + | | Operator Name: [[FRONTIER NATURAL RESOURCES]] |
|- | |- | ||
− | | Well Pad ID: | + | | Well Pad ID: [[144827]] |
|- | |- | ||
− | | Farm/Lease Name: | + | | Farm/Lease Name: WINNER 4 8HG |
|- | |- | ||
− | | License Status: | + | | License Status: Regulatory Inactive Status |
|- | |- | ||
− | | Spud Date: | + | | Spud Date: 2010-10-25 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2010-09-03 |
|- | |- | ||
− | | Unconventional Well: | + | | Unconventional Well: Y |
|- | |- | ||
− | | Configuration: | + | | Configuration: Horizontal Well |
|- | |- | ||
− | | Latitude: | + | | Latitude: 41.224586 |
|- | |- | ||
− | | Longitude: | + | | Longitude: -77.998044 |
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | <!--== Production Data == | + | <!--== Fracking Activities == |
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
+ | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
!scope="col" | Period | !scope="col" | Period | ||
Line 60: | Line 85: | ||
!scope="col" | Water Production Days | !scope="col" | Water Production Days | ||
|- | |- | ||
− | |}-- | + | | 2010 |
− | + | | [[ENERPLUS RES USA CORP]] | |
− | + | | style="text-align: right;" | 0.00 | |
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 2011 | ||
+ | | [[ENERPLUS RES USA CORP]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 2012 | ||
+ | | [[ENERPLUS RES USA CORP]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 2013 | ||
+ | | [[ENERPLUS RES USA CORP]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 2014 | ||
+ | | [[ENERPLUS RES USA CORP]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 2015 | ||
+ | | [[ENERPLUS RES USA CORP]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 2016 | ||
+ | | [[FRONTIER NATURAL RESOURCES]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 2017 | ||
+ | | [[FRONTIER NATURAL RESOURCES]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 2019 | ||
+ | | [[FRONTIER NATURAL RESOURCES]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Production Reports | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-03-31 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
!scope="col" | Period | !scope="col" | Period | ||
Line 70: | Line 181: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | |}-- | + | | 2010-S02 |
− | + | | Drill Cuttings (in Tons) | |
− | + | | style="text-align: right;" | 124.99 Tons | |
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | 301333 | ||
+ | |- | ||
+ | | 2010-S02 | ||
+ | | Drill Cuttings (in Tons) | ||
+ | | style="text-align: right;" | 1,405.73 Tons | ||
+ | | LANDFILL | ||
+ | | 101571 | ||
+ | |- | ||
+ | | 2011-S01 | ||
+ | | Spent Lubricant (in Barrels) | ||
+ | | style="text-align: right;" | 250.50 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | 301333 | ||
+ | |- | ||
+ | | 2011-S02 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 2,140.00 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | 301333 | ||
+ | |- | ||
+ | | 2011-S02 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 14,510.00 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | EPA ID: 748-163 | ||
+ | |- | ||
+ | | 2011-S02 | ||
+ | | Spent Lubricant (in Barrels) | ||
+ | | style="text-align: right;" | 240.00 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | EPA ID: 748-163 | ||
+ | |- | ||
+ | | 2011-S02 | ||
+ | | Spent Lubricant (in Barrels) | ||
+ | | style="text-align: right;" | 147.62 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | PAD014286009 | ||
+ | |- | ||
+ | | 2014-S01 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 12,920.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-119-28776 | ||
+ | |- | ||
+ | | 2014-S02 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 11,211.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-133-20525 | ||
+ | |- | ||
+ | | 2014-S02 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-151-21198 | ||
+ | |- | ||
+ | | 2014-S02 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 570.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-151-23420 | ||
+ | |- | ||
+ | | 2014-S02 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 95.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-155-2-3794 | ||
+ | |- | ||
+ | | 2014-S02 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 3,063.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-155-21893 | ||
+ | |- | ||
+ | | 2014-S02 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 560.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-155-22403 | ||
+ | |- | ||
+ | | 2014-S02 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 2,035.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-155-23795 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Waste Reports | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-03-31 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Inspection Data == | ||
==== Inspections Performed ==== | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 82: | Line 288: | ||
!scope="col" | Inspection Comments | !scope="col" | Inspection Comments | ||
|- | |- | ||
− | | | + | | 1919997 |
− | + | | Primary Facility | |
+ | | 2010-10-14 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | Conductor is set and then drilled to 120'. UDI 121 perparing to move in. | ||
+ | |- | ||
+ | | 1923515 | ||
+ | | Primary Facility | ||
+ | | 2010-10-26 | ||
+ | | Routine/Partial Inspection | ||
+ | | Violation(s) Noted | ||
+ | | Cuttings and surfactant/defoamer on ground | ||
+ | |- | ||
+ | | 1926632 | ||
+ | | Primary Facility | ||
+ | | 2010-11-09 | ||
+ | | Follow-up Inspection | ||
+ | | Violation(s) Noted | ||
+ | | No Fencing Around impoundment which was nearly 3/4 full | ||
+ | |- | ||
+ | | 1926969 | ||
+ | | Primary Facility | ||
+ | | 2010-11-02 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | UDI 121 preparing to run in hole after BOP test and drillout 9 5/8" | ||
+ | |- | ||
+ | | 1928114 | ||
+ | | Primary Facility | ||
+ | | 2010-11-16 | ||
+ | | Follow-up Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 1932149 | ||
+ | | Primary Facility | ||
+ | | 2010-11-24 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | Kicking off @ 7354' | ||
+ | |- | ||
+ | | 1938752 | ||
+ | | Primary Facility | ||
+ | | 2010-12-14 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | UDI 121 drilling 8 1/2" hole @ 9135' | ||
+ | |- | ||
+ | | 1942763 | ||
+ | | Primary Facility | ||
+ | | 2011-01-04 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | UDI 121 rigging down. Well drilled to TD and production casing is cemented | ||
+ | |- | ||
+ | | 2034834 | ||
+ | | Primary Facility | ||
+ | | 2011-11-30 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2160157 | ||
+ | | Primary Facility | ||
+ | | 2013-04-22 | ||
+ | | Follow-up Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2181819 | ||
+ | | Primary Facility | ||
+ | | 2013-07-09 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2265450 | ||
+ | | Primary Facility | ||
+ | | 2014-04-24 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2287405 | ||
+ | | Primary Facility | ||
+ | | 2014-03-25 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2371995 | ||
+ | | Primary Facility | ||
+ | | 2015-05-19 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2410077 | ||
+ | | Primary Facility | ||
+ | | 2015-09-24 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2508341 | ||
+ | | Primary Facility | ||
+ | | 2016-07-29 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2702625 | ||
+ | | Primary Facility | ||
+ | | 2018-03-05 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | The weather is 50 Deg. F, partially cloudy and partially sunny at time of inspection. Routine inspection of Frontier Natural Resources, Winner 4 Pad, 8HG well on March 5, 2018. | ||
+ | There are 2 inactive and shut in wells on this pad. Annulus vents are open and vented at time of inspection. 40% LEL and 0% combustible gas was detected at the production by intermediate (5-1/2 X 9-5/8) annulus vent. Production casting pressure gauge reads 4400 psi. There are 2 gas separator units and 2 tanks stored on location. All equipment has been disconnected from these two wells. No obvious concerns or violations are noted at time of inspection. This well passed inspection for placing it for inactive status. | ||
+ | DEP Representative - Ulyana Trynovich, Oil and Gas Inspector. | ||
+ | |- | ||
+ | |} | ||
+ | ==== Violations Commited ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
!scope="col" | Inspection ID | !scope="col" | Inspection ID | ||
Line 93: | Line 420: | ||
!scope="col" | Violation Comments | !scope="col" | Violation Comments | ||
|- | |- | ||
− | | | + | | 1923515 |
+ | | 598236 | ||
+ | | 10/26/2010 | ||
+ | | 2010-10-26 | ||
+ | | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | ||
+ | | Administrative | ||
+ | | 78.56(a) | ||
+ | |- | ||
+ | | 1923515 | ||
+ | | 598237 | ||
+ | | 10/26/2010 | ||
+ | | 2010-10-26 | ||
+ | | 301CSL - Stream discharge of IW, includes drill cuttings, oil, brine and/or silt | ||
+ | | Environmental Health & Safety | ||
+ | | | ||
+ | |- | ||
+ | | 1923515 | ||
+ | | 598238 | ||
+ | | 10/26/2010 | ||
+ | | 2010-10-26 | ||
+ | | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | ||
+ | | Environmental Health & Safety | ||
+ | | | ||
+ | |- | ||
+ | | 1923515 | ||
+ | | 598239 | ||
+ | | 10/26/2010 | ||
+ | | 2010-10-26 | ||
+ | | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | ||
+ | | Environmental Health & Safety | ||
+ | | | ||
+ | |- | ||
+ | | 1926632 | ||
+ | | 599064 | ||
+ | | 11/09/2010 | ||
+ | | 2010-11-09 | ||
+ | | 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. | ||
+ | | Administrative | ||
+ | | | ||
+ | |- | ||
+ | |} | ||
<!--==== Penalties Applied ==== | <!--==== Penalties Applied ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 106: | Line 473: | ||
|- | |- | ||
|}--> | |}--> | ||
− | + | For data sources see<ref>{{cite web | |
− | < | + | | title =Oil and Gas Compliance Report |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | { | + | | date = 2019-05-20 |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
− | + | | accessdate = 2019-05-21 }}</ref> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Pennsylvania Wells]] | [[Category:Pennsylvania Wells]] |
Well ID: 37-035-21226 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.224586,"lon":-77.998044,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Clinton | |
Municipality: West Keating Township | |
Operator Name: FRONTIER NATURAL RESOURCES | |
Well Pad ID: 144827 | |
Farm/Lease Name: WINNER 4 8HG | |
License Status: Regulatory Inactive Status | |
Spud Date: 2010-10-25 | |
Permit Date: 2010-09-03 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.224586 | |
Longitude: -77.998044 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | ENERPLUS RES USA CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | ENERPLUS RES USA CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | ENERPLUS RES USA CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | ENERPLUS RES USA CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | ENERPLUS RES USA CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | ENERPLUS RES USA CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | FRONTIER NATURAL RESOURCES | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | FRONTIER NATURAL RESOURCES | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2019 | FRONTIER NATURAL RESOURCES | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2010-S02 | Drill Cuttings (in Tons) | 124.99 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 301333 |
2010-S02 | Drill Cuttings (in Tons) | 1,405.73 Tons | LANDFILL | 101571 |
2011-S01 | Spent Lubricant (in Barrels) | 250.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 301333 |
2011-S02 | Produced Fluid (in Barrels) | 2,140.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 301333 |
2011-S02 | Produced Fluid (in Barrels) | 14,510.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2011-S02 | Spent Lubricant (in Barrels) | 240.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2011-S02 | Spent Lubricant (in Barrels) | 147.62 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAD014286009 |
2014-S01 | Fracing Fluid Waste (in Barrels) | 12,920.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 11,211.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20525 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-151-21198 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 570.00 Bbl | INJECTION DISPOSAL WELL | 34-151-23420 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-2-3794 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 3,063.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 560.00 Bbl | INJECTION DISPOSAL WELL | 34-155-22403 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 2,035.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1919997 | Primary Facility | 2010-10-14 | Drilling/Alteration | No Violations Noted | Conductor is set and then drilled to 120'. UDI 121 perparing to move in. |
1923515 | Primary Facility | 2010-10-26 | Routine/Partial Inspection | Violation(s) Noted | Cuttings and surfactant/defoamer on ground |
1926632 | Primary Facility | 2010-11-09 | Follow-up Inspection | Violation(s) Noted | No Fencing Around impoundment which was nearly 3/4 full |
1926969 | Primary Facility | 2010-11-02 | Drilling/Alteration | No Violations Noted | UDI 121 preparing to run in hole after BOP test and drillout 9 5/8" |
1928114 | Primary Facility | 2010-11-16 | Follow-up Inspection | No Violations Noted | |
1932149 | Primary Facility | 2010-11-24 | Drilling/Alteration | No Violations Noted | Kicking off @ 7354' |
1938752 | Primary Facility | 2010-12-14 | Drilling/Alteration | No Violations Noted | UDI 121 drilling 8 1/2" hole @ 9135' |
1942763 | Primary Facility | 2011-01-04 | Drilling/Alteration | No Violations Noted | UDI 121 rigging down. Well drilled to TD and production casing is cemented |
2034834 | Primary Facility | 2011-11-30 | Routine/Complete Inspection | No Violations Noted | |
2160157 | Primary Facility | 2013-04-22 | Follow-up Inspection | No Violations Noted | |
2181819 | Primary Facility | 2013-07-09 | Routine/Complete Inspection | No Violations Noted | |
2265450 | Primary Facility | 2014-04-24 | Routine/Complete Inspection | No Violations Noted | |
2287405 | Primary Facility | 2014-03-25 | Routine/Complete Inspection | No Violations Noted | |
2371995 | Primary Facility | 2015-05-19 | Routine/Complete Inspection | No Violations Noted | |
2410077 | Primary Facility | 2015-09-24 | Routine/Complete Inspection | No Violations Noted | |
2508341 | Primary Facility | 2016-07-29 | Routine/Complete Inspection | No Violations Noted | |
2702625 | Primary Facility | 2018-03-05 | Routine/Complete Inspection | No Violations Noted | The weather is 50 Deg. F, partially cloudy and partially sunny at time of inspection. Routine inspection of Frontier Natural Resources, Winner 4 Pad, 8HG well on March 5, 2018.
There are 2 inactive and shut in wells on this pad. Annulus vents are open and vented at time of inspection. 40% LEL and 0% combustible gas was detected at the production by intermediate (5-1/2 X 9-5/8) annulus vent. Production casting pressure gauge reads 4400 psi. There are 2 gas separator units and 2 tanks stored on location. All equipment has been disconnected from these two wells. No obvious concerns or violations are noted at time of inspection. This well passed inspection for placing it for inactive status. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1923515 | 598236 | 10/26/2010 | 2010-10-26 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | 78.56(a) |
1923515 | 598237 | 10/26/2010 | 2010-10-26 | 301CSL - Stream discharge of IW, includes drill cuttings, oil, brine and/or silt | Environmental Health & Safety | |
1923515 | 598238 | 10/26/2010 | 2010-10-26 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
1923515 | 598239 | 10/26/2010 | 2010-10-26 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
1926632 | 599064 | 11/09/2010 | 2010-11-09 | 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. | Administrative |
For data sources see[6]