If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-027-20763 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.092856,"lon":-78.016384,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Centre | |
Municipality: Burnside Township | |
Operator Name: ALLIANCE PETRO CO LLC | |
Well Pad ID: | |
Farm/Lease Name: STATE GAME LANDS NO 100 23 | |
License Status: ACTIVE | |
Spud Date: | |
Permit Date: 2001-08-03 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.092856 | |
Longitude: -78.016384 |
Date | Event |
---|---|
2001-08-03 | New Permit Application |
2001-09-27 | Performed Spud Operation |
2001-10-02 | Drilling Completion |
2001-10-09 | Perforation |
2002-04-27 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2004 | EXCO RESOURCES PA INC | 4879 | 365 | 0.00 | 0 | 0.00 | 0 |
2005 | EXCO RESOURCES PA INC | 8,076.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2006 | EXCO RESOURCES PA INC | 7,703.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2007 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2008 | EXCO RESOURCES PA INC | 5974.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2009 | EXCO RESOURCES PA INC | 5266.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2010 | EXCO RESOURCES PA INC | 4,908.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA INC | 4,557.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 4,210.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 4,036.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 3,712.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 3,311.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | ALLIANCE PETRO CO LLC | 967.00 | 183 | 0.00 | 0 | 0.00 | 0 |
2017 | ALLIANCE PETRO CO LLC | 3,011.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | ALLIANCE PETRO CO LLC | 2,547.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | ALLIANCE PETRO CO LLC | 2,384.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2006 | EXCO RESOURCES PA INC | Brine | 87.00 Bbl | Municipal Sewage Treatment Plant | PA0020486 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1071639 | Primary Facility | 2001-10-15 | Routine/Complete Inspection | No Violations Noted | Well is hooked up and operating. Drilling Pit and frac pit still exist. E&S ok |
2722109 | Primary Facility | 2018-04-24 | Routine/Complete Inspection | No Violations Noted | Department representative Sue Herzing conducted a routine site inspection at Alliance Petroleum Corporation's conventional well (027-20763) on April 24, 2018. The area surrounding the production equipment has been restored. Restored site is well vegetated. No signs of E&S issues. Brine tank is labeled with the well permit number. Chart recorder is dated 4/3/18. The well head and connecting pipes are being maintained; no corrosion or flakey paint were observed on this equipment. Department staff used an Altair 5x gas meter around the production equipment. No combustible gases were detected.
No violations noted. |