If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-073-22294 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.54849653,"lon":-82.38113045,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Hocking | |
Municipality: Green Township | |
Operator Name: HOCKING HILLS ENERGY AND WELL | |
Well Pad ID: | |
Farm/Lease Name: VAN SICKLE WM R | |
License Status: Producing | |
License Date: 1983-08-18 | |
Spud Date: 1980-05-11 | |
Spud Drilling Contractor: | |
Final Drill Date: 1980-05-16 | |
Well Total Depth: 3007 ft | |
Configuration: Vertical | |
Latitude: 39.548496530 | |
Longitude: -82.38113045 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-04-23 | 40 ORWIG CHAS DBA ORWIG OIL GeoDate 4/23/80 |
Oil and Gas | 1980-04-23 | Issued Date 4/23/80 Expired Date Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1980-05-11 | |
Completed | 1980-05-16 | |
Reached Total Depth | 1980-05-16 | |
Completion Report Received | 1980-08-11 | |
CO | 1983-08-18 | 1818 VAN SICKLE WILLIAM R GeoDate 8/18/83 |
Unknown | 1983-08-18 | Issued Date 8/18/83 Expired Date Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date |
Construction Permit Expires | 1984-02-14 | |
CO | 1992-12-04 | 1068 COSPER WELL/H COSPER GeoDate 8/18/83 |
CO | 1995-02-07 | 4074 OIL ENTERPRISES GeoDate 8/18/83 |
CO | 1997-02-18 | 5755 CHIEFTAIN ENERGY CORP. GeoDate 8/18/83 |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 2891 | 3007 | 13 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 25000 Gal | 80000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
005609i182 | 2001-05-02 | Annular Disposal | No Violations | A inspection of the well site and tank battery revealed that there had been an oil spill from the well , it appears the stuffing box had leaked , company has cleaned up all the oily soils. |
0071123865 | 2004-06-15 | Annular Disposal | Violations Noted | An inspection of the well revealed oily soil around tanks, ID not complete, needs rewrote, dike wall low, does not meet SPCC requirements. |
0199038726 | 2013-11-25 | Production Wells | No Violations | Compliance notice follow up. The well is being worked on. There is a motor on the pumping unit but is not hooked up. I have called Hocking Hills energy to determine a schedule to have the well back in production. The well is non compliant. |
0213563180 | 2006-07-26 | Annular Disposal | Violations Noted | An inspection was conducted at the facility owned by Chieftain Energy Corp on 7/26/2006. During the inspection, it was noted that a new ID is needed at the well and oily soil needs cleaned up around the tank battery. |
0289738252 | 2004-09-28 | Annular Disposal | No Violations | Follow-up, Non-Compliance, Doug Kiycken and Joe Hoerst on inspection. |
0485383043 | 2011-02-22 | Annular Disposal | No Violations | Accompanied Mr. Andy Thomas for the inspection of this well. Mr. Thomas will discuss the details of this inspection with Mr. Robert Stonerock, South Region Oil & Gas Supervisor. |
0700253062 | 2017-08-03 | Production Wells | No Violations | Compliance notice follow-up. The well has been worked on. The polish rod is shiny and the pulleys show the unit has been operated recently. I spoke with well owner Doug Kitchen and he said the electric motor failed and would be replaced by 8.8.17. |
0714048752 | 2011-02-22 | Production Wells | No Violations | FOLLOW UP TO NOV # -1311664821 Upon an inpection with Brent Bear, we found no motor on the pumpjack, and all valves closed. There was corrosion on the bottom of one of the two 100 bbl. tanks that showed a small amount of leakage. Tank needs to be repaired. |
0876308402 | 2014-05-12 | Production Wells | No Violations | Upon inspection, this well is now capable of production and appears to be producing. The gate valve on the 2.5 tubing is open and the pressure gauge on the tubing reads 30 p.s.i. The polish rod on the pumping unit shows signs of recent pumping. This satisfies the requirements of the compliance notice. Upon inspecting the tank battery, the northernmost 100 bbl. production tank has a slight leak from the bottom weld and is allowing small amounts of oil and brine to release into the containment dike. I contacted Hocking Hills Energy and notified them of the issue, and they stated that a well tender will fix the problem in short order. |
0927301349 | 2014-06-04 | Production Wells | No Violations | Upon inspection, it was observed that the oily soil around the production tanks within the containment dike has been treated with oil absorbent material and gravel, but the leaky tank does not appear to have been repaired. I will check on this site again in a few weeks to see if the tank has been repaired and/or removed. |
1151816469 | 2014-06-18 | Production Wells | No Violations | Production well inspection. The well consists of a pumping unit and 2-100 barrel tanks. No violations noted. |
1244148633 | 2017-08-09 | Production Wells | No Violations | Compliance notice follow-up. The well has a new electric motor, the polish rod is shiny and the pulleys show the well has been in operation. Legible identification has been posted. This satisfies the compliance notice. |
1269i12450 | 2000-10-30 | Production Wells | No Violations | No violations at this time. |
1311664821 | 2011-02-22 | Production Wells | Violations Noted | Upon an inpection with Brent Bear, we found no motor on the pumpjack, and all valves closed. There was corrosion on the bottom of one of the two 100 bbl. tanks that showed a small amount of leakage. Tank needs to be repaired. |
1333918066 | 2006-10-03 | Production Wells | No Violations | A follow-up inpsection was conducted on 10/3/2006. During the inspection, it was noted that the previously noted violations have not been resolved. |
1368943600 | 2008-03-10 | Production Wells | No Violations | No violations were noted. |
1374017671 | 2011-11-23 | Production Wells | Violations Noted | Well not in compliance. Nothing changed from last inspection. Production reports for 2010 are 0. Brine tank needs repaired or replaced. Well must be placed back in production. |
1486566768 | 2017-02-08 | Production Wells | Violations Noted | I received a request from landowner William Robert Vansickle. I met with Mr. Vansickle today at 0938 hours. Mr. Vansickle stated he wanted the well to be plugged because the well is not capable of production. He stated that the well only produces water. Production reporting shows 4740 barrels of brine in 2012, 1120 barrels of brine in 2013 and 1120 barrels of brine in 2014. The last reported production was in 2009. The valve on the tubing is open, the valve on the casing was closed. The pumping unit does not have a motor. The polish rod is dull and the pulleys on the pumping unit are rusty. The well consists of a pumping unit, 2- |
1909820222 | 2006-10-19 | Production Wells | No Violations | A follow-up inspection revealed that the previously noted violations have been resolved. |
1916841151 | 2004-11-23 | Annular Disposal | No Violations | Follow-up on NOV, In-Compliance. |
1944019393 | 2004-07-28 | Annular Disposal | No Violations | Non-Compliance |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0071123865 | US-OH-128051 | 2004-06-15 | Well operation causing pollution and contamination | |
0071123865 | US-OH-128052 | 2004-06-15 | Failure to legibly identify well | |
0071123865 | US-OH-128053 | 2004-06-15 | Equipment pressure rated below operating pressure | |
0071123865 | US-OH-128054 | 2004-06-15 | No SPCC dike/or failure to keep dike free of water or oil | |
0213563180 | US-OH-121888 | 2006-08-04 | Failure to legibly identify well | |
0213563180 | US-OH-121889 | 2006-08-04 | No SPCC dike/or failure to keep dike free of water or oil | |
1311664821 | US-OH-108828 | 2011-03-15 | Equipment pressure rated below operating pressure | |
1374017671 | US-OH-111075 | 2011-11-28 | Nonproduction; well shall be plugged or placed in temporary inactive status | |
1486566768 | US-OH-113816 | 2017-08-11 | NONE | Well shall be plugged |