| Well ID: 37-081-21325 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.434475,"lon":-77.038742,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Lycoming | |
| Municipality: Lewis Township | |
| Operator Name: SENECA RESOURCES CO LLC | |
| Well Pad ID: 150186 | |
| Farm/Lease Name: DCNR 100 46H 50860 | |
| License Status: Active | |
| Spud Date: 2013-10-19 | |
| Permit Date: 2013-09-30 | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Latitude: 41.434475 | |
| Longitude: -77.038742 |
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2014-07-20 | 2014-07-26 | 8916 | 6,187,020.0 | 0 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | MBC 516 | Trican | Biocide | N-alkyl dimethyl benzyl ammonium chloride | 68424-85-1 | 5.5 | 0.00052777 | 0 |
| Glutaraldehyde | 111-30-8 | 27 | 0.00259087 | 0 | ||||
| Didecyl dimethyl ammonium chloride | 7173-51-5 | 8.3 | 0.00079645 | 0 | ||||
| Ethanol | 64-17-5 | 2.8 | 0.00026868 | 0 | ||||
| FEAC 20 | Trican | Iron Control | Acetic acid | 64-19-7 | 50 | 0.00075029 | 0 | |
| Citric acid | 77-92-9 | 30 | 0.00045018 | 0 | ||||
| Proppant 40/70 Ottawa | Trican | Proppant | Crystalline silica (quartz) | 14808-60-7 | 100 | 5.19619 | 0 | |
| Sl-7 | Trican | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30 | 0.00822898 | 0 | |
| 7.5% HydroChloric Acid | Trican | Acid | Hydrochloric Acid HCl | 7647-01-0 | 7.5 | 0.0739527 | 0 | |
| FR-15 | Trican | Friction Reducer | Proprietary Amide | Proprietary | 2.5 | 0.0022771 | 0 | |
| Distillates (petroleum), Hydrotreated Light | 64742-47-8 | 25 | 0.022771 | 0 | ||||
| Proppant 30/50 Ottawa | Trican | Proppant | Crystalline silica (quartz) | 14808-60-7 | 100 | 4.98955 | 0 | |
| AL-7NR | Trican | Corrosion Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1 | 0.00002119 | 0 | |
| Proppant 80/100 Oklahoma | Trican | Proppant | Silica | 14808-60-7 | 100 | 0.798547 | 0 | |
| Water | Seneca Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.9031 | 0 |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2013 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2014 | SENECA RESOURCES CO LLC | 740,455.40 | 86 | 0.00 | 0 | 0.00 | 0 |
| 2015 | SENECA RESOURCES CO LLC | 1,894,706.72 | 363 | 0.00 | 0 | 0.00 | 0 |
| 2016 | SENECA RESOURCES CO LLC | 1,254,644.72 | 278 | 0.00 | 0 | 0.00 | 0 |
| 2017 | SENECA RESOURCES CO LLC | 966,570.41 | 355 | 0.00 | 0 | 0.00 | 0 |
| 2018 | SENECA RESOURCES CO LLC | 670,813.97 | 363 | 0.00 | 0 | 0.00 | 0 |
| 2019 | SENECA RESOURCES CO LLC | 136,662.92 | 88 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
| Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|
| 2013-S02 | Drill Cuttings (in Tons) | 81.85 Tons | LANDFILL | 301358 |
| 2013-S02 | Drill Cuttings (in Tons) | 1,162.56 Tons | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR097R017 |
| 2014-S02 | Produced Fluid (in Barrels) | 28.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
| 2014-S02 | Produced Fluid (in Barrels) | 10.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
| 2014-S02 | Produced Fluid (in Barrels) | 8.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
| 2014-S02 | Produced Fluid (in Barrels) | 98.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
| 2014-S02 | Produced Fluid (in Barrels) | 7,905.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015-S01 | Produced Fluid (in Barrels) | 132.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
| 2015-S01 | Produced Fluid (in Barrels) | 33.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
| 2015-S01 | Produced Fluid (in Barrels) | 2,621.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015-S02 | Drilling Fluid Waste (in Barrels) | 72.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2015-S02 | Fracing Fluid Waste (in Barrels) | 1,008.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2015-S02 | Produced Fluid (in Barrels) | 873.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2015-S02 | Produced Fluid (in Barrels) | 360.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016-M01 | Produced Fluid (in Barrels) RWC 802 | 165.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016-M02 | Produced Fluid (in Barrels) RWC 802 | 152.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016-M03 | Produced Fluid (in Barrels) RWC 802 | 85.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016-M04 | Produced Fluid (in Barrels) RWC 802 | 102.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016-M05 | Produced Fluid (in Barrels) RWC 802 | 63.89 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016-M06 | Produced Fluid (in Barrels) RWC 802 | 102.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016-M07 | Produced Fluid (in Barrels) RWC 802 | 38.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016-M07 | Produced Fluid (in Barrels) RWC 802 | 23.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016-M08 | Produced Fluid (in Barrels) RWC 802 | 38.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016-M09 | Produced Fluid (in Barrels) RWC 802 | 107.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016-M10 | Produced Fluid (in Barrels) RWC 802 | 27.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016-M11 | Produced Fluid (in Barrels) RWC 802 | 108.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2016-M12 | Produced Fluid (in Barrels) RWC 802 | 69.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2017-M01 | Produced Fluid (in Barrels) RWC 802 | 62.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2017-M01 | Produced Fluid (in Barrels) RWC 802 | 25.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-M02 | Produced Fluid (in Barrels) RWC 802 | 62.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2017-M03 | Produced Fluid (in Barrels) RWC 802 | 46.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2017-M03 | Produced Fluid (in Barrels) RWC 802 | 66.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-M04 | Produced Fluid (in Barrels) RWC 802 | 14.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2017-M04 | Produced Fluid (in Barrels) RWC 802 | 69.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-M05 | Produced Fluid (in Barrels) RWC 802 | 74.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2017-M05 | Produced Fluid (in Barrels) RWC 802 | 13.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-M06 | Produced Fluid (in Barrels) RWC 802 | 76.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-M07 | Produced Fluid (in Barrels) RWC 802 | 27.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2017-M07 | Produced Fluid (in Barrels) RWC 802 | 25.50 Bbl | REUSE (AT WELL PAD) | |
| 2017-M07 | Synthetic Liner Materials (in Tons) RWC 806 | 4.78 Tons | LANDFILL | 301358 |
| 2017-M10 | Produced Fluid (in Barrels) RWC 802 | 83.33 Bbl | REUSE (AT WELL PAD) | |
| 2017-M11 | Produced Fluid (in Barrels) RWC 802 | 57.78 Bbl | REUSE (AT WELL PAD) | |
| 2017-M12 | Produced Fluid (in Barrels) RWC 802 | 41.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2017-M12 | Produced Fluid (in Barrels) RWC 802 | 14.44 Bbl | REUSE (AT WELL PAD) | |
| 2018-M01 | Produced Fluid (in Barrels) RWC 802 | 43.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2018-M01 | Produced Fluid (in Barrels) RWC 802 | 27.22 Bbl | REUSE (AT WELL PAD) | |
| 2018-M02 | Produced Fluid (in Barrels) RWC 802 | 14.44 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2018-M02 | Produced Fluid (in Barrels) RWC 802 | 14.44 Bbl | REUSE (AT WELL PAD) | |
| 2018-M03 | Produced Fluid (in Barrels) RWC 802 | 31.11 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2018-M03 | Produced Fluid (in Barrels) RWC 802 | 12.78 Bbl | REUSE (AT WELL PAD) | |
| 2018-M04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 12.22 Bbl | REUSE (AT WELL PAD) | |
| 2018-M04 | Produced Fluid (in Barrels) RWC 802 | 16.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2018-M04 | Produced Fluid (in Barrels) RWC 802 | 24.44 Bbl | REUSE (AT WELL PAD) | |
| 2018-M05 | Produced Fluid (in Barrels) RWC 802 | 31.11 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2018-M05 | Produced Fluid (in Barrels) RWC 802 | 11.11 Bbl | REUSE (AT WELL PAD) | |
| 2018-M06 | Produced Fluid (in Barrels) RWC 802 | 44.44 Bbl | REUSE (AT WELL PAD) | |
| 2018-M07 | Produced Fluid (in Barrels) RWC 802 | 16.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2018-M07 | Produced Fluid (in Barrels) RWC 802 | 14.44 Bbl | REUSE (AT WELL PAD) | |
| 2018-M08 | Produced Fluid (in Barrels) RWC 802 | 64.44 Bbl | REUSE (AT WELL PAD) | |
| 2018-M09 | Produced Fluid (in Barrels) RWC 802 | 57.78 Bbl | REUSE (AT WELL PAD) | |
| 2018-M10 | Produced Fluid (in Barrels) RWC 802 | 57.78 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2018-M11 | Produced Fluid (in Barrels) RWC 802 | 72.22 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2018-M12 | Produced Fluid (in Barrels) RWC 802 | 32.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2018-M12 | Produced Fluid (in Barrels) RWC 802 | 32.50 Bbl | REUSE (AT WELL PAD) | |
| 2019-M01 | Produced Fluid (in Barrels) RWC 802 | 25.56 Bbl | REUSE (AT WELL PAD) | |
| 2019-M02 | Produced Fluid (in Barrels) RWC 802 | 14.44 Bbl | REUSE (AT WELL PAD) | |
| 2019-M03 | Produced Fluid (in Barrels) RWC 802 | 14.44 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC003 |
| 2019-M03 | Produced Fluid (in Barrels) RWC 802 | 28.89 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
For data sources see[6]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2240326 | Primary Facility | 2014-01-27 | Drilling/Alteration | No Violations Noted | |
| 2601607 | Primary Facility | 2017-05-18 | Routine/Complete Inspection | No Violations Noted | Routine inspection of unconventional well in production. Well tag noted as being incorrect in inspection report. No violations noted at time of inspection. |
| 2713793 | Primary Facility | 2018-03-26 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 3/26/2018.
At the time of the inspection, 9 wells were in production. The PCSM has been implemented but is not functioning as designed. The fresh water impoundment has been removed and the area reclaimed. I recommend reviewing the implementation of the PCSM. No violations noted. |
| 2810184 | Primary Facility | 2018-11-29 | Routine/Complete Inspection | No Violations Noted | Nine wells staged for production. Nine GPUs within 10 inch polyurethane coated Styrofoam containment. No leaks from production equipment.
A well site restoration period extension request was submitted on 10/26/2018. The request will be returned due to PCSM issues. |
For data sources see[7]