X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20633

Well Details

Well ID: 42-115-20633
Loading map...
County: Susquehanna
Municipality: Lenox Township
Operator Name: SOUTHWESTERN ENERGY PROD CO
Well Pad ID: 148964
Farm/Lease Name: NORTH VALENTINE PRICE GU 1H
First Permit Date: 2011-08-31
Last Permit Date: 2011-08-31
Spud Date: 2011-09-06
Unconventional: Yes
Horizontal: Yes
Producing: Yes
Violations: None
Latitude: 41.715352
Longitude: -75.642094

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
2005417 2011-09-15 No Violations Noted
2020128 2011-11-16 No Violations Noted Desoto Rig 9. Follow up inspection as result of nearby water supply complaint. Currently at depth = 12784'. Drilling with SOBM. TD proposed = 13249'. Drillers log on site and up to date. Should be running 5 1.2" prod casing this weekend. And then skidding to 5H well. Drilled tophole on air. Drillers log shows conditions wet at 296'. Also Damp hole at 1040. Cement reports indicate good returns on cement for surface and intermediate casing strings. 20" set at 80', 13 3/8" set at 648', and 9 5/8" set at 1628'.
2126838 2012-12-18 No Violations Noted During the inspection I met with Tyler Parsons, Lead Flowhand of Rod’s Production Services. He informed me flowback operations commenced on 12/11/12 and thus far (5,400) barrels of flowback fluid has been filtered. Currently, flowback is in progress, but the filter system is not is in use. The filtration equipment has been supplied by Tetra Technologies Inc.

I used an an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen several areas of ponded water on the secondary containment liner, the surface of the ground on the Well Pad and off the Well Pad. The highest conductivity reading I recorded was (2) milliSiemens/cm behind the frac tanks used as part of the flowback filtration. All other conductivity readings were below (1,000) microSiemens/cm. I observed some rips and tears in the liner in some areas, mainly near where the alternative waste management practice took place, some petroleum like sheens and (1) light tower that did not have a drip pan/catchment basin under it. I departed from the site at 12:50.

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2012-2 0.0 0.0 0.0 0.0 0.0 0.0
2012-1 0.0 0.0 0.0 0.0 0.0 0.0
2011-2 0.0 0.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2012-2 FLOWBACK FRACTURING SAND 19.54 Tons LANDFILL 101247 KEYSTONE SANITARY LANDFILL DUNMORE PA

References