37-081-21731

Well Details

Well ID: 37-081-21731
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Cogan House Township
Operator Name: ARD OPR LLC
Well Pad ID: 145720
Farm/Lease Name: ELBOW F&G C-215H
License Status: Active
Spud Date: 03/22/2018
Permit Date: 2/28/2018
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.378253
Longitude: -77.229744

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2019 ARD OPR LLC 0.00 0 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2018-M07 Drill Cuttings (in Tons) RWC 810 514.38 Tons LANDFILL 100955
2018-M08 Drill Cuttings (in Tons) RWC 810 1,123.36 Tons LANDFILL 100955
2018-M09 Drill Cuttings (in Tons) RWC 810 1,173.38 Tons LANDFILL 100955
2018-M09 Synthetic Liner Materials (in Tons) RWC 806 34.30 Tons LANDFILL 100955
2018-M10 Synthetic Liner Materials (in Tons) RWC 806 0.17 Tons LANDFILL 100955
2019-M02 Servicing Fluid (in Barrels) RWC 808 15.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019-M02 Servicing Fluid (in Barrels) RWC 808 15.06 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019-M02 Servicing Fluid (in Barrels) RWC 808 15.71 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 17.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019-M03 Produced Fluid (in Barrels) RWC 802 14.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019-M03 Synthetic Liner Materials (in Tons) RWC 806 0.81 Tons LANDFILL 100955

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2754021 Primary Facility 2018-07-19 Routine/Complete Inspection No Violations Noted Weather was 70° and sunny at time of inspection. Met with Alta representative Bill Mitchel on location. At time of inspection rig had just started drilling the 17 1/2" hole for the surface casing. They are estimating a TD of 650'. Conducted a walk around inspection of location. No violations were noted at time of inspection.
2759493 Primary Facility 2018-07-27 Routine/Complete Inspection No Violations Noted Routine Inspection; 7/27/2018.

I entered the site at 15:25 and talked to Bill Mitchell (company man). The Flexrig 225 was onsite drilling the curve (oil based mud) on the Elbow F&G C-213H (081-21729) well at the time of the inspection. The containment was in good condition and i recommend continued vacuuming as water has accumulated from precipitation. Overall, the site and access road have also held up well from the significant rainfall recently. No violations noted.

2769700 Primary Facility 2018-08-30 Routine/Complete Inspection No Violations Noted I met R.D. Mann when I arrived. H&P 225 rig on location, drilling at 6300' on the 215H well. Overall condition of the containment and berms was good, but near the chemical containment area, the berm was completely covered by gravel, making it impossible to see. In the chemical containment area, I noted a rig wash tote set on a pallet that was not completely on the pallet and was leaning slightly as a result; I recommended to R.D that it be stabilized. Some water was present in secondary containments, but did not seem to be excessive. I also noted that the 6" drill mud line was vibrating and abrading the liner at a union near a 90 degree joint. R.D. told me he would see to these issues.
2776407 Primary Facility 2018-09-18 Drilling/Alteration No Violations Noted Seven wells recently drilled. Rig no longer on location. Rig matting removed. Primary felt containment remains at this time. The containment is covered in drilling mud from washing of the rig matting. The operator is reminded to remove standing water before removal of the containment. Three puddles on the pad surface returned 250 uS/cm of conductivity. No spills detected at this time. Site stable. No violations noted.

For data sources see[6]