37-081-21043

Well Details

Well ID: 37-081-21043
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Gamble Township
Operator Name: DIVERSIFIED OIL & GAS LLC
Well Pad ID: 149186
Farm/Lease Name: RHODES 3H
License Status: Active
Spud Date: 09/27/2012
Permit Date: 9/19/2012
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.381581
Longitude: -76.977436

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2013 ATLAS RESOURCES LLC 1,498,535.00 155 0.00 0 0.00 0
2014 ATLAS RESOURCES LLC 2,354,977.00 365 0.00 0 0.00 0
2015 ATLAS RESOURCES LLC 1,238,035.00 365 0.00 0 0.00 0
2016 ATLAS RESOURCES LLC 1,068,655.00 340 0.00 0 0.00 0
2017 ATLAS RESOURCES LLC 895,411.00 365 0.00 0 0.00 0
2018 ATLAS RESOURCES LLC 1,042,419.00 365 0.00 0 0.00 0
2019 DIVERSIFIED OIL & GAS LLC 197,211.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-S02 Drill Cuttings (in Tons) 1,021.67 Tons LANDFILL 301626
2012-S02 Drilling Fluid Waste (in Barrels) 1,980.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013-S01 Fracing Fluid Waste (in Barrels) 2,569.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013-S01 Fracing Fluid Waste (in Barrels) 2,162.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013-S01 Fracing Fluid Waste (in Barrels) 987.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW008
2013-S01 Fracing Fluid Waste (in Barrels) 283.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Produced Fluid (in Barrels) 3,088.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013-S02 Produced Fluid (in Barrels) 405.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013-S02 Produced Fluid (in Barrels) 1,514.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014-S01 Produced Fluid (in Barrels) 3,583.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014-S02 Produced Fluid (in Barrels) 425.20 Bbl INJECTION DISPOSAL WELL 34-155-24063
2014-S02 Produced Fluid (in Barrels) 849.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015-S01 Produced Fluid (in Barrels) 158.70 Bbl INJECTION DISPOSAL WELL 34-155-24063
2015-S01 Produced Fluid (in Barrels) 626.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015-S01 Produced Fluid (in Barrels) 106.40 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 394.00 Bbl INJECTION DISPOSAL WELL 34-155-24063
2015-S02 Produced Fluid (in Barrels) 32.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 715.00 Bbl INJECTION DISPOSAL WELL 34-133-24462
2016-S01 Produced Fluid (in Barrels) RWC 802 139.00 Bbl INJECTION DISPOSAL WELL 34-155-24063
2016-S02 Produced Fluid (in Barrels) RWC 802 272.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016-S02 Produced Fluid (in Barrels) RWC 802 104.00 Bbl INJECTION DISPOSAL WELL 34-133-24462
2016-S02 Produced Fluid (in Barrels) RWC 802 104.00 Bbl INJECTION DISPOSAL WELL 34-155-24063
2016-S02 Produced Fluid (in Barrels) RWC 802 209.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 136.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M02 Produced Fluid (in Barrels) RWC 802 115.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M03 Produced Fluid (in Barrels) RWC 802 115.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M04 Produced Fluid (in Barrels) RWC 802 115.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M05 Produced Fluid (in Barrels) RWC 802 115.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M06 Produced Fluid (in Barrels) RWC 802 115.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M08 Produced Fluid (in Barrels) RWC 802 240.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017-M09 Produced Fluid (in Barrels) RWC 802 120.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017-M10 Produced Fluid (in Barrels) RWC 802 120.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M11 Produced Fluid (in Barrels) RWC 802 120.00 Bbl REUSE OTHER THAN ROAD SPREADING
2018-M01 Produced Fluid (in Barrels) RWC 802 120.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M03 Produced Fluid (in Barrels) RWC 802 120.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018-M04 Produced Fluid (in Barrels) RWC 802 232.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M05 Produced Fluid (in Barrels) RWC 802 231.00 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 118.00 Bbl REUSE (AT WELL PAD)
2018-M08 Produced Fluid (in Barrels) RWC 802 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M09 Produced Fluid (in Barrels) RWC 802 114.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M10 Produced Fluid (in Barrels) RWC 802 115.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M11 Produced Fluid (in Barrels) RWC 802 194.00 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 169.00 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 177.00 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2110080 Primary Facility 10/17/2012 Drilling/Alteration No Violations Noted
2110522 Primary Facility 10/23/2012 Routine/Complete Inspection No Violations Noted
2119080 Primary Facility 11/28/2012 Routine/Complete Inspection No Violations Noted
2136426 Primary Facility 02/05/2013 Drilling/Alteration No Violations Noted
2137210 Primary Facility 01/24/2013 Routine/Complete Inspection No Violations Noted
2138347 Primary Facility 02/07/2013 Routine/Complete Inspection No Violations Noted
2139229 Primary Facility 02/13/2013 Drilling/Alteration No Violations Noted
2146896 Primary Facility 10/27/2015 Routine/Complete Inspection No Violations Noted At the time of inspection: arrived @ 15:26. Three wells were spudded, cellars were dry. Annuli were plumbed into production tanks. Also onsite were 2 production tanks, 3 production units, and a sand separator. A technician was calibrating gauges on the production units at the time of my inspection. No violations were noted during the inspection. Left location @ 15:35.
2147704 Primary Facility 03/08/2013 Drilling/Alteration No Violations Noted
2236774 Primary Facility 01/09/2014 Incident- Response to Accident or Event No Violations Noted TEG (Glycol) sprayed to the pad surface. VIOIC to 081-20889
2261527 Primary Facility 04/02/2014 Routine/Partial Inspection No Violations Noted 3 wells in production. No Vio
2263291 Primary Facility 03/19/2014 Routine/Complete Inspection No Violations Noted
2352364 Primary Facility 03/13/2015 Complaint Inspection No Violations Noted On 3/13/2015, the complaint contacted the Department concerning the odor allegedly coming from the Rhodes well pad. Ms. Beacker and I arrived onsite at 10:00 and spoke with the well tender (John Moltz). The well tender, Ms. Beacker, and I walked the site. The production equipment all appeared to be functioning properly but an odor similar to what the complainant described was evident. The well tender noted that the odor was a normal part of the operation of the well and specifically the dehydration unit. Approximately 10-20 barrels of spent glycol (Triethylene glycol) was being stored onsite in containment. The odor described by the complainant and noted by the Department is described as an odor but is not characterized as a mal-odor. As discussed on 3/16/2015, please review the O&M procedures for the dehydration unit and makes sure the unit is functioning properly. No Violations Noted.
2454131 Primary Facility 2016-02-25 Routine/Complete Inspection No Violations Noted At the time of the Well Site Restoration Report inspection, three wells onsite are in production.

All permanent PCSM control features identified in the permitted plans have been installed. But, the infiltration basin slopes lack vegetative cover and have noticeable erosion. Silt sock around the site was cut open but the synthetic fabric has not been removed. Silt sock above the access road was left intact and was not removed. Plastic netting from erosion control blanketing was left at several locations. On the fill slope at the northwest side of the pad, the slopes show signs of recent (the last 24 hours) and historic erosion. Overall, the site lack 70% uniform perennial vegetative cover, shows signs of accelerated erosion, and has plastic material from erosion control blanketing and silt sock that have not been removed. I recommend the Well Site Restoration Report be denied.

2537916 Primary Facility 2016-11-14 Routine/Complete Inspection No Violations Noted Arrived @ 12:30, weather sunny, warm. All three wells onsite were in production. Annuli were plumbed into production tanks. Cellars were filled with gravel. Met with lease operator Jon Moltz. (all psi readings digital).

Rhodes 1H: tubing: 1223.7 psi, casing: 1130.8 psi Rhodes 2H: tubing 1217 psi, casing: 1021 psi Rhodes 3H: tubing 1507.9 psi, casing: 1139.3 psi. A slope slip was evident near the entrance gate. Moltz said that Atlas was aware of this and planning to fix it. Confirmed this with WQS on return to the office. No violations were noted during the inspection. Left location @ 13:00.

2696602 Primary Facility 2018-02-21 Routine/Complete Inspection No Violations Noted Weather was 53° and cloudy at time of inspection. Met with Atlas representative John Moltz on location. Well had 3 annulus vents plumbed to surface with analog pressure gauges on them. All 3 gauges read 0 psi at time of inspection. Well had a digital pressure gauge attached to the tubing and the production casing. The casing pressure was 1460 psi and the tubing pressure was 1295 psi. No violations were noted at time of inspection.
2782569 Primary Facility 2018-10-02 Routine/Complete Inspection No Violations Noted Three wells stage for production. Three water separators. One sand separator. No leaks detected from production equipment. No violations noted.
2809713 Primary Facility 2018-12-04 Routine/Complete Inspection No Violations Noted Weather was 34° and cloudy at time of inspection. There were no Diversified Oil and Gas representatives on location at time of inspection. Well hard digital pressure monitoring equipment attached to the production casing in the production tubing. Production casing was 1279 psi and production tubing was 1204 psi at time of inspection. There were 3 annulus vents plumbed to surface at time of inspection. All 3 vents were plumbed together and ran to the production tanks. No violations were noted at time of inspection.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 03/31/2013 03/31/2013 8366.0 5176626.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Alpha 1427 Baker Hughes Biocide Didecyl Dimethyl Ammonium Chloride 7173-51-5 10.0 0.00222
Ferrotrol 300L Baker Hughes Iron Control Citric Acid 77-92-9 60.0 0.00264
CI-14 Baker Hughes Corrosion Inhibitor Fatty Acids Trade Secret 10.0 0.00015
Water Operator Carrier Water 7732-18-5 100.0 88.4703
FRW-18 Baker Hughes Friction Reducer Petroleum Distillates 64742-47-8 30.0 0.01546
Water 7732-18-5 None 0.0484498772
Quaternary Ammonium Compound 68424-85-1 5.0 0.00111
Hydrochloric Acid 7647-01-0 None 0.00001516
Methanol 67-56-1 None 0.0015157844
Sorbitan Monooleate Trade Secret None 0.002576851
Propargyl Alcohol 107-19-7 5.0 0.00008000
Poly (acrylamide-co-acrylic acid) Trade Secret None 0.0154611062
Formaldehyde 50-00-0 None 0.00001516
Salt Trade Secret None 0.002576851
Water 7732-18-5 92.5 0.93448
Polyacrylate Trade Secret None 0.0030302878
Glutaraldehyde 111-30-8 30.0 0.00667
Ethylene Glycol 107-21-1 30.0 0.00455
Olefin Trade Secret 5.0 0.00008000
Ethanol 64-17-5 5.0 0.00111
Ethoxylated Alcohol Trade Secret None 0.0010307404
Sodium Chloride 7647-14-5 None 0.00000455
Potassium Chloride 7447-40-7 None 0.00000758
Polyoxyalkylenes Trade Secret 30.0 0.00045
Modified Thiorea Polymer 68527-49-1 None 0.0001061049
Scaletrol 720 Baker Hughes Scale Inhibitor Calcium Chloride 10043-52-4 5.0 0.00076
Ingredients shown above are subject to 29 CFR 1910.1200(i) and appear on Material Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS. None None
HCl, 5.1 - 7.5 Baker Hughes Acidizing Hydrochloric Acid 7647-01-0 7.5 0.07577
Sand, White, 40/70 Baker Hughes Proppant Crystalline Silica (Quartz) 14808-60-7 100.0 10.40939

For data sources see[7]