If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 37-081-20284 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.345053,"lon":-77.267836,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Lycoming | |
| Municipality: Cummings Township | |
| Operator Name: ARD OPR LLC | |
| Well Pad ID: 148733 | |
| Farm/Lease Name: LARRYS CREEK F&G A 2H | |
| License Status: Active | |
| Spud Date: 06/25/2010 | |
| Permit Date: 4/13/2010 | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Latitude: 41.345053 | |
| Longitude: -77.267836 |
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2010 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2011 | ANADARKO E&P ONSHORE LLC | 547,842.00 | 84 | 0.00 | 0 | 0.00 | 0 |
| 2012 | ANADARKO E&P ONSHORE LLC | 2,004,394.00 | 366 | 0.00 | 0 | 0.00 | 0 |
| 2013 | ANADARKO E&P ONSHORE LLC | 1,019,507.00 | 346 | 0.00 | 0 | 0.00 | 0 |
| 2014 | ANADARKO E&P ONSHORE LLC | 716,704.00 | 274 | 0.00 | 0 | 0.00 | 0 |
| 2015 | ANADARKO E&P ONSHORE LLC | 748,296.00 | 352 | 0.00 | 0 | 0.00 | 0 |
| 2016 | ANADARKO E&P ONSHORE LLC | 530,697.00 | 366 | 0.00 | 0 | 0.00 | 0 |
| 2017 | ANADARKO E&P ONSHORE LLC | 428,820.84 | 363 | 0.00 | 0 | 0.00 | 0 |
| 2018 | ARD OPR LLC | 384,400.43 | 365 | 0.00 | 0 | 0.00 | 0 |
| 2019 | ARD OPR LLC | 81,635.30 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
| Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|
| 2010-A01 | Drilling Fluid Waste (in Barrels) | 1,068.00 Bbl | IDENTIFY METHOD IN COMMENTS | |
| 2010-S01 | Drilling Fluid Waste (in Barrels) | 534.00 Bbl | IDENTIFY METHOD IN COMMENTS | |
| 2012-S02 | Produced Fluid (in Barrels) | 815.20 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013-S01 | Produced Fluid (in Barrels) | 573.01 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013-S02 | Produced Fluid (in Barrels) | 375.46 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014-S01 | Produced Fluid (in Barrels) | 441.24 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014-S02 | Produced Fluid (in Barrels) | 150.63 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015-S01 | Produced Fluid (in Barrels) | 751.42 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015-S02 | Produced Fluid (in Barrels) | 194.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
| 2015-S02 | Produced Fluid (in Barrels) | 130.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2016-M09 | Produced Fluid (in Barrels) RWC 802 | 16.45 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
| 2016-M10 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
| 2016-M11 | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
| 2016-M12 | Produced Fluid (in Barrels) RWC 802 | 46.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2016-S01 | Produced Fluid (in Barrels) RWC 802 | 161.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
| 2016-S01 | Produced Fluid (in Barrels) RWC 802 | 43.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
| 2016-S01 | Produced Fluid (in Barrels) RWC 802 | 104.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2016-S02 | Produced Fluid (in Barrels) RWC 802 | 46.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2016-S02 | Produced Fluid (in Barrels) RWC 802 | 48.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
| 2017-M01 | Produced Fluid (in Barrels) RWC 802 | 46.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2017-M03 | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2017-M04 | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2017-M05 | Produced Fluid (in Barrels) RWC 802 | 53.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
| 2017-M08 | Produced Fluid (in Barrels) RWC 802 | 49.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2017-M09 | Produced Fluid (in Barrels) RWC 802 | 48.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2017-M10 | Produced Fluid (in Barrels) RWC 802 | 30.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2017-M10 | Produced Fluid (in Barrels) RWC 802 | 18.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
| 2017-M11 | Produced Fluid (in Barrels) RWC 802 | 49.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
| 2017-M12 | Produced Fluid (in Barrels) RWC 802 | 4.16 Bbl | REUSE (AT WELL PAD) | |
| 2018-M01 | Produced Fluid (in Barrels) RWC 802 | 12.84 Bbl | REUSE (AT WELL PAD) | |
| 2018-M02 | Produced Fluid (in Barrels) RWC 802 | 33.00 Bbl | REUSE (AT WELL PAD) | |
| 2018-M03 | Produced Fluid (in Barrels) RWC 802 | 49.00 Bbl | REUSE (AT WELL PAD) | |
| 2018-M04 | Produced Fluid (in Barrels) RWC 802 | 46.71 Bbl | REUSE (AT WELL PAD) | |
| 2018-M06 | Produced Fluid (in Barrels) RWC 802 | 47.42 Bbl | REUSE (AT WELL PAD) | |
| 2018-M07 | Produced Fluid (in Barrels) RWC 802 | 64.92 Bbl | REUSE (AT WELL PAD) | |
| 2018-M08 | Produced Fluid (in Barrels) RWC 802 | 55.24 Bbl | REUSE (AT WELL PAD) | |
| 2019-M02 | Produced Fluid (in Barrels) RWC 802 | 26.01 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 1902287 | Primary Facility | 07/19/2010 | Drilling/Alteration | No Violations Noted | |
| 1915767 | Primary Facility | 09/22/2010 | Routine/Partial Inspection | Violation(s) Noted | Cement returns, cuttings, oil, and grease on ground around cellars; litter lying around perimeter of site |
| 1918242 | Primary Facility | 10/04/2010 | Follow-up Inspection | Outstanding Violations - Viols Req'd | Cuttings,Oil,Grease, and cemenet returns on ground |
| 1926570 | Primary Facility | 11/03/2010 | Drilling/Alteration | No Violations Noted | |
| 1928422 | Primary Facility | 11/04/2010 | Follow-up Inspection | No Violations Noted | |
| 1941557 | Primary Facility | 01/04/2011 | Routine/Partial Inspection | Violation(s) Noted | |
| 1955170 | Primary Facility | 02/22/2011 | Routine/Partial Inspection | No Violations Noted | |
| 1971925 | Primary Facility | 05/06/2011 | Routine/Complete Inspection | No Violations Noted | |
| 1989873 | Primary Facility | 07/21/2011 | Routine/Partial Inspection | No Violations Noted | |
| 1992470 | Primary Facility | 07/26/2011 | Routine/Partial Inspection | No Violations Noted | |
| 2054478 | Primary Facility | 03/19/2012 | Follow-up Inspection | Viol(s) Noted & Immediately Corrected | Responded to a reported spill of production water. clean-up has been completed |
| 2504512 | Primary Facility | 2016-07-19 | Routine/Complete Inspection | No Violations Noted | |
| 2675691 | Primary Facility | 2017-12-21 | Routine/Complete Inspection | No Violations Noted | Weather was 33° and sunny at time of inspection. There were no ARD representatives on location at time of inspection. Well has a digital pressure gauge attached above swab valve, on the 5 1/2 x 9 5/8 annulus and on the production casing. Tubing pressure read 304 psi, casing pressure was 396 and annulus pressure was 1380 psi at time of inspection. |
| 2776184 | Primary Facility | 2018-09-18 | Routine/Complete Inspection | No Violations Noted | Five wells in production stage. One well in regulatory inactive stage. No bubbles in well cellars. Five water separators. No leaks detected from production equipment. No restoration of site noted. No violations noted |
| Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
|---|---|---|---|---|---|---|
| 1915767 | 595981 | 09/22/2010 | 11/04/2010 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | 78.56(a) |
| 1915767 | 595982 | 09/22/2010 | 11/04/2010 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
| 1915767 | 595983 | 09/22/2010 | 11/04/2010 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
| 1918242 | 596672 | 10/04/2010 | 11/04/2010 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | |
| 1918242 | 596673 | 10/04/2010 | 11/04/2010 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
| 1918242 | 596674 | 10/04/2010 | 11/04/2010 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
| 1918242 | 596688 | 10/04/2010 | 11/04/2010 | 78.65(1)* - Rat hole not filled | Environmental Health & Safety | |
| 1941557 | 602591 | 01/04/2011 | 01/10/2011 | 307CSL - Discharge of industrial waste to waters of Commonwealth without a permit. | Environmental Health & Safety | Diesel spill on pad |
| 1941557 | 602592 | 01/04/2011 | 01/10/2011 | 402POTNLPOLL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit. | Environmental Health & Safety | |
| 2054478 | 635490 | 03/19/2012 | 03/19/2012 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
| 2054478 | 635491 | 03/19/2012 | 03/19/2012 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | |
| 2054478 | 635492 | 03/19/2012 | 03/19/2012 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety |
For data sources see[6]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 07/22/2011 | 07/22/2011 | 8285.00 | 4,097,355.0 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | Water | Anadarko | Carrier/Base Fluid | Water | 7732-18-5 | 100.00 | 85.50 | |
| TXP-10 | Trican Well Service | Scale Inhibitor | Acrylate phosphonate copolymer | 40.00 | 0.00419000 | |||
| Neutralized organic acid | 20.00 | 0.00210000 | ||||||
| Water | 7732-18-5 | 70.00 | 0.00734000 | |||||
| 1,2-Propylene glycol | 57-55-6 | 10.00 | 0.00105000 | |||||
| TXP-11 | Trican Well Service | Clay Control | Water | 7732-18-5 | 60.00 | 0.06 | ||
| Poly Electrolyte | 40.00 | 0.04 | ||||||
| Chloride | 16887-00-6 | 30.00 | 0.03 | |||||
| Inorganic Chemical | 20.00 | 0.02 | ||||||
| TXP-8 | Trican Well Service | Friction Reducer | ||||||
| WG-111L | Trican Well Service | Viscosifier/Gelant | Distillates, petroleum, hydrotreated light | 64742-47-8 | 60.00 | 0.00520000 | ||
| Polysaccharide blend | 60.00 | 0.00520000 | ||||||
| AI-7NR | Trican Well Service | Corrosion Inhibitor | Propargyl alcohol | 107-19-7 | 1.00 | 0.00003000 | ||
| Acid, Hydrochloric (7.5) | Trican Well Service | Solvent | Hydrochloric acid | 7647-01-0 | 7.50 | 0.04 | ||
| WBO-2 | Trican Well Service | Gel Breaker | Sodium persulfate | 7775-27-1 | 100.00 | 0.00039000 | ||
| Sand (Proppant) | Trican Well Service | Proppant | Quartz | 14808-60-7 | 100.00 | 13.58 | ||
| TXP-8 | Friction Reducer | Cationic water-soluble polymer emulsion | 100.00 | 0.08 | ||||
| BioClear 5000 | Trican Well Service | Biocide | Polyethylene glycol | 25322-68-3 | 70.00 | 0.01 | ||
| 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 10.00 | 0.00260000 | |||||
| FEAC-20 | Trican Well Service | Iron Control | Acetic acid | 64-19-7 | 50.00 | 0.00313000 | ||
| Citric acid | 77-92-9 | 30.00 | 0.00188000 |
For data sources see[7]