X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-033-26466

Well Details

Well ID: 37-033-26466
Loading map...
Country: United States
State: Pennsylvania
County: Clearfield
Municipality: Brady Township
Operator Name: DEVONIAN RESOURCES INC
Well Pad ID:
Farm/Lease Name: SHAFFER NANCY 2
License Status: Active
Spud Date: 06/25/2007
Permit Date: 6/8/2007
Unconventional Well: N
Configuration: Vertical Well
Latitude: 41.030795
Longitude: -78.798990

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 DEVONIAN RESOURCES INC 8,278.00 365 0.00 0.00
2009 DEVONIAN RESOURCES INC 4,807.00 365 0.00 0.00
2010 DEVONIAN RESOURCES INC 3,597.00 365 0.00 0.00
2011 DEVONIAN RESOURCES INC 3,347.00 365 0.00 0.00
2012 DEVONIAN RESOURCES INC 2,481.00 365 0.00 0.00
2013 DEVONIAN RESOURCES INC 1,463.00 365 0.00 0.00
2014 DEVONIAN RESOURCES INC 1,649.00 365 0.00 0.00
2015 DEVONIAN RESOURCES INC 1,679.00 335 0.00 0.00
2016 DEVONIAN RESOURCES INC 1,708.00 365 0.00 0.00
2017 DEVONIAN RESOURCES INC 1,650.00 365 0.00 0.00
2018 DEVONIAN RESOURCES INC 1,079.00 365 0.00 0.00

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2008-A00 Brine 390.00 Bbl Municipal Sewage Treatment Plant
2009-A00 Brine 269.00 Bbl Municipal Sewage Treatment Plant PA0028207
2010-A00 Produced Fluid (in Barrels) 182.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2011-A00 Produced Fluid (in Barrels) 118.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2012-A00 Produced Fluid (in Barrels) 40.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2013-A00 Produced Fluid (in Barrels) 95.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2014-A00 Produced Fluid (in Barrels) 120.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2016-A00 Produced Fluid (in Barrels) RWC 802 73.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1668439 Primary Facility 11/02/2007 Site Restoration No Violations Noted WELL EQUIPPED FOR PRODUCTION. TANK SOUND. SITE RESTORED - FINAL STABILIZATION COMPLETE. ACCESS ROAD STABLE
2797557 Primary Facility 2018-10-29 Routine/Complete Inspection No Violations Noted Department representative Sue Herzing conducted a routine site inspection at Devonian Resources Inc. conventional well (033-26466) on October 29, 2018. The area surrounding the production equipment has been restored. Restored site is well vegetated. No signs of E&S issues. The chart recorder is labeled with the operators name, operators contact information, and well permit number. No date was observed on the chart recorder. Flakey paint and corrosion were observed on the well head, separator, and axillary piping. The Department recommends monitoring the production equipment and replacing and/or repainting the equipment if necessary.

Department staff used an Altair 5x gas meter during the inspection. Combustible gases were detected at 15% LEL on some of the axillary pipes connected to the well head (see photo). The Department recommends addressing the combustible gas issue.

This case will be referred to a Department Oil & Gas Inspector for further investigation.

2804933 Primary Facility 2018-11-13 Follow-up Inspection No Violations Noted The weather is 40 Deg. F and cloudy at time of inspection. Follow up inspection of Devonian Resources Inc., Shaffer Nancy Pad Well # 2 on November 13, 2018.

There is 1 producing well on this pad. Production processing equipment includes separator and production water tank, methanol bottle; measurement equipment - orifice meter station. Additional meter has been installed for the residential consumer. Annulus (7 x 4-1/2) was closed upon arrival to location. Company operator opened annulus during inspection, observed foam coming out of the vent. Left vent closed. Detected gas leak (55%LEL, 3% combustible gas) at the meter line. Verified pressures: casing pressure - 450 PSI, line pressure ¿ 90 PSI. No violations are noted at time of inspection, but discussed further repairs and follow up inspection with company owner that is present during this inspection. Devonian Resources Inc. Representatives ¿ Joe Thompson, Company Owner; Bill Mays, Well Tender. DEP Representative Ulyana Trynovich, Oil and Gas Inspector; Su

2854993 Primary Facility 2019-03-18 Routine/Complete Inspection No Violations Noted The weather is 42 Deg. F and cloudy at time of inspection. Follow up inspection of Devonian Resources Inc., Shaffer Nancy Pad Well # 2 on March 18, 2019.

There is 1 producing well on this pad. Production processing equipment includes separator and production water tank, methanol bottle; measurement equipment - orifice meter station. Additional meter has been installed for the residential consumer. Annulus (7 x 4-1/2) was closed upon arrival to location. Company operator opened annulus during inspection, observed foam coming out of the vent. Left vent closed. Gas leak at the meter line that was detected on November 13, 2018 has been fixed. No violations are noted at time of inspection. Devonian Resources Inc. - Representatives Bill Mays, Well Tender. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector.

For data sources see[6]

References