X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21676

Well Details

Well ID: 37-117-21676
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Chatham Township
Operator Name: SWEPI LP
Well Pad ID: 149542
Farm/Lease Name: WATKINS 820 23H
License Status: Active
Spud Date: 02/05/2014
Permit Date: 1/21/2014
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.893336
Longitude: -77.410253

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 SWEPI LP 82,002.90 9 0.00 0 0.00 0
2015 SWEPI LP 1,734,226.99 338 0.00 0 0.00 0
2016 SWEPI LP 739,588.58 349 0.00 0 0.00 0
2017 SWEPI LP 472,500.33 359 0.00 0 0.00 0
2018 SWEPI LP 321,546.51 339 0.00 0 0.00 0
2019 SWEPI LP 58,099.85 70 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2014-1 Drill Cuttings (in Tons) 549.69 Tons LANDFILL 301358
2014-1 Drilling Fluid Waste (in Barrels) 194.03 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-1 Drilling Fluid Waste (in Barrels) 17.43 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014-1 Drilling Fluid Waste (in Barrels) 439.60 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Fracing Fluid Waste (in Barrels) 90.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 646.19 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Drill Cuttings (in Tons) 323.85 Tons LANDFILL 301358
2014-2 Drilling Fluid Waste (in Barrels) 33.60 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Fracing Fluid Waste (in Barrels) 82.72 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-2 Fracing Fluid Waste (in Barrels) 0.63 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2014-2 Fracing Fluid Waste (in Barrels) 3,056.42 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 33.44 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-2 Produced Fluid (in Barrels) 16.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014-2 Produced Fluid (in Barrels) 95.94 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Fracing Fluid Waste (in Barrels) 13.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-1 Fracing Fluid Waste (in Barrels) 1,021.33 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 261.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-1 Produced Fluid (in Barrels) 3,459.20 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Fracing Fluid Waste (in Barrels) 0.20 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 239.85 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-2 Produced Fluid (in Barrels) 1,305.72 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015-2 Produced Fluid (in Barrels) 2,451.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 2,404.60 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Produced Fluid (in Barrels) RWC 802 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016-2 Produced Fluid (in Barrels) RWC 802 2,375.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Waste Water Treatment Sludge (in Tons) RWC 804 4.94 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-01 Produced Fluid (in Barrels) RWC 802 60.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-01 Produced Fluid (in Barrels) RWC 802 0.20 Bbl REUSE (AT WELL PAD)
2017-02 Produced Fluid (in Barrels) RWC 802 264.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-03 Produced Fluid (in Barrels) RWC 802 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-03 Produced Fluid (in Barrels) RWC 802 480.00 Bbl REUSE (AT WELL PAD)
2017-04 Produced Fluid (in Barrels) RWC 802 256.80 Bbl REUSE (AT WELL PAD)
2017-04 Waste Water Treatment Sludge (in Tons) RWC 804 2.26 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-05 Produced Fluid (in Barrels) RWC 802 240.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-05 Produced Fluid (in Barrels) RWC 802 40.00 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 20.00 Bbl REUSE (AT WELL PAD)
2017-07 Produced Fluid (in Barrels) RWC 802 80.00 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 240.00 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 58.31 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-09 Produced Fluid (in Barrels) RWC 802 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-09 Produced Fluid (in Barrels) RWC 802 128.00 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 381.20 Bbl REUSE (AT WELL PAD)
2017-10 Waste Water Treatment Sludge (in Tons) RWC 804 0.57 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-11 Produced Fluid (in Barrels) RWC 802 100.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-11 Produced Fluid (in Barrels) RWC 802 20.00 Bbl REUSE (AT WELL PAD)
2017-12 Produced Fluid (in Barrels) RWC 802 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-12 Produced Fluid (in Barrels) RWC 802 200.00 Bbl REUSE (AT WELL PAD)
2018-01 Produced Fluid (in Barrels) RWC 802 200.00 Bbl REUSE (AT WELL PAD)
2018-01 Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 0.01 Tons RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2018-02 Produced Fluid (in Barrels) RWC 802 240.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-03 Produced Fluid (in Barrels) RWC 802 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-03 Produced Fluid (in Barrels) RWC 802 10.00 Bbl REUSE (AT WELL PAD)
2018-04 Produced Fluid (in Barrels) RWC 802 186.00 Bbl REUSE (AT WELL PAD)
2018-05 Produced Fluid (in Barrels) RWC 802 185.91 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-06 Produced Fluid (in Barrels) RWC 802 19.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-06 Produced Fluid (in Barrels) RWC 802 60.00 Bbl REUSE (AT WELL PAD)
2018-06 Waste Water Treatment Sludge (in Tons) RWC 804 1.13 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-07 Produced Fluid (in Barrels) RWC 802 140.00 Bbl REUSE (AT WELL PAD)
2018-08 Produced Fluid (in Barrels) RWC 802 60.00 Bbl REUSE (AT WELL PAD)
2018-08 Waste Water Treatment Sludge (in Tons) RWC 804 2.26 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-09 Produced Fluid (in Barrels) RWC 802 180.00 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 38.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-10 Produced Fluid (in Barrels) RWC 802 113.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-11 Produced Fluid (in Barrels) RWC 802 144.65 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-11 Produced Fluid (in Barrels) RWC 802 0.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-11 Waste Water Treatment Sludge (in Tons) RWC 804 2.83 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-12 Produced Fluid (in Barrels) RWC 802 77.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-12 Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE (AT WELL PAD)
2019-01 Produced Fluid (in Barrels) RWC 802 350.25 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 387.25 Bbl REUSE (AT WELL PAD)
2019-03 Produced Fluid (in Barrels) RWC 802 19.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019-03 Produced Fluid (in Barrels) RWC 802 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2242851 Primary Facility 02/04/2014 Routine/Complete Inspection No Violations Noted
2252301 Primary Facility 02/12/2014 Routine/Complete Inspection No Violations Noted
2258279 Primary Facility 03/24/2014 Drilling/Alteration No Violations Noted
2297530 Primary Facility 08/19/2014 Drilling/Alteration No Violations Noted
2313023 Primary Facility 10/15/2014 Routine/Complete Inspection No Violations Noted
2316982 Primary Facility 10/29/2014 Complaint Inspection No Violations Noted The Department inspected the Watkins 820, permit# ESX11-117-0019, in Chatham Twp., Tioga Co. on 10/29/14 @ 1110 hours in response to a water supply complaint. The weather was 52 degrees and overcast. Present onsite were Jonathan Pennings, DEP WQS and Mike Parker, OSR Swepi LP. No oil and gas activity was taking place onsite during the inspection. A hydro excavator was onsite looking for utility lines buried beneath the pad surface. Mr. Parker stated staged fracking had been completed on the Watkins 820 23H and 25H wells, both Utica wells, between 9/28/14 and 10/18/14. They were hoping to frack the Watkins 21H in the next few days, also a Utica well. He also stated the two Marcellus wells, the Watkins 5H and 5HS were “shut in”. The Watkins 2H through 6H wells were listed as “operator reported not drilled”.
2328183 Primary Facility 12/08/2014 Incident- Response to Accident or Event No Violations Noted The SWEPI, LP Watkins 820 site in Chatham Twp., Tioga Co. was inspected by the Department @ 1230 hours on 12/8/14. The weather was 28 degrees with strong winds out of the southeast. Personnel onsite included Terra Tokarz, DEP WQS, AJ Lewis, onsite OSR, and Matt Bailey, AMEC. Rory Hunter, SWEPI LP contacted the Department at 0930 hours on 12/8/14 to report an environmental cleanup underway on the Watkins 820 pad. Swepi had performed a post-frac screening on the Watkins on 11/17/14. During this screening, soil conductivity readings greater than 1mS/cm were encountered in the vicinity of the tank battery. Field conductivity screenings were not completed until 12/3/14 when the tank battery had been removed, and additional areas of elevated conductivity above 1mS/cm were found. Violations were cited against the Watkins 820 21H well permt #2328155. Violations were immediately corrected.
2484931 Primary Facility 2016-05-17 Routine/Complete Inspection Pending The SWEPI, LP Watkins 820 site in Chatham Twp., Tioga Co. was inspected by the Department @ 1300 hours on 5/17/16. The weather was 59°, cloudy, winds WSW 8 mph. A valid site ID sign was observed at the entrace to the access road. The PPC Plan, onsite inspection log, well permits and a copy of the E&S plan were observed in the mailbox. The site was last inspected by company personnel on 5/11/2016 with “no change” noted in the comments.

During the onsite inspection, fluid was osberved in the the containment surrounding the 500-barrel- tanks. The fluid was screened for conductivity using an Oakton Multi-Parameter PCSTestr 35. The field conductivity was measured at 2.98 mS/cm. A puddle was observed on the pad surface adjacent to the tank containment. This puddle measured 7.34 mS/cm. An additional puddle (it was not clear in the field if the two were connected) was also screened and the field conductivity measured 6.77 mS/cm. A sampled of the puddle measuring 7.34 mS/cm was obtained and submitted to the lab in

2494025 Primary Facility 2016-05-17 Administrative/File Review Violation(s) Noted An administrative report was generated for the SWEPI LP – Watkins 820 site in Chatham Twp., Tioga Co. (ESX11-117-0019). Sample results collected 5/17/2016 indicate the presence of a pollution substance on the ground outside of containment. This constitutes a violation of 25 Pa. Code 78.45 (relating to Oil and Gas Wells) against the Watkins 820 23H well, permit #117-21676, based on the laboratory sample results. In accordance with S 78.54 the well operator shall control and dispose of fluids, residual waste and rill cuttings, including tophole water, brines, drilling fluids, drilling muds, stimulation fluids, well servicing fluids, oil, production fluids and drill cuttings in a manner that prevents pollution of the waters of this Commonwealth and in accordance with §§ 78.55-78.58 and 78.60-78.63 and with the statutes under which this chapter is promulgated.

No violations were cited against eh ESCGP or remaining well permit numbers.

2494156 Primary Facility 2016-06-08 Follow-up Inspection No Violations Noted The Department of Environmental Protection (DEP) conducted an onsite Follow-up inspection at the SWEPI LP – Watkins 820 well site in Chatham Twp., Tioga Co. (ESX11-117-0019) on 6/8/2016 @ 1010 hours. The weather was 50° and raining. The DEP was notified SWEPI would be conducting additional remediation efforts to remove soil with an elevated conductivity related to an unknown/unreported release on 6/8/2016.

Background: A violation of 25 PA. Code 78.54 was issued 5/17/2016 based on sample results, collected from a puddle outside containment by the DEP, showing elevated chlorides and conductivity . On 5/18/2016 SWEPI investigated the DEP’s findings. Mr. Bernethy stated he found areas of elevated conductivity and sent a vacuum truck to the site to clean up the puddles. SWEPI was investigating the secondary containment and the reason no spill was reported.

As of today’s inspection, SWEPI has removed material from the affected area. Approximately ½ a roll-off waste container of material was removed. Please pr
2523517 Primary Facility 2016-09-22 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the Wakins 820 site in Chatham Twp., Tioga Co. on 9/22/2016 @1245 hours. The valid site ID sign is located at the entrance to the access road. The site was last inspected by company personnel on 9/10/2016 with “erosion on lease road. Erosion on back side of pad by frac tanks and gravel.” recorded in the comments section.

No puddles were observed on the pad surface. Standing water was observed in the secondary containment surrounding the roll off tanks. The field conductivity was measured at 800µS/cm. Erosion was observed on the access road as noted in the E&S log. An area on the back side of the tank pad appears to have a mound of sawdust like material. Shredded ECB matting is visible on top of it. No vegetation was observed, but the pile does not appear to be eroding. All E&S controls appear to be functional. No violations are noted at this time. I departed the site @ 1330 hours. This inspection report references the following well permits – 117-

2548023 Primary Facility 2016-12-28 Routine/Complete Inspection No Violations Noted
2557553 Primary Facility 2017-02-01 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the SWEPI LP Watkins 820 well site in Chatham Twp., Tioga Co. on 2/1/2017. The weather was partly sunny, 30°, fresh snow accumulation of ~3". No activity was observed onsite. No puddles observed on the pad surface. No vegetation was observed, but the site appears to be stable. Erosion and sediment controls were not observed due to snow cover, but no issues were detected. No violations were issued during this inspection. Please contact me with any questions.
2633466 Primary Facility 2017-09-06 Routine/Partial Inspection No Violations Noted EC readings with Oakton PCSTestr 35 (mS/cm): containment--0.27, pad--0.22.
2722373 Primary Facility 2018-04-24 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection inspected the Watkins 820 Well Site located in Chatham Twp, Tioga Co. on 4/25/2018 @ 1415 hours. The weather was 60 degrees and partly sunny . No activity was observed onsite.

There are five producing wells onsite. Production fluids are contained in Highland tanks. Water was observed in the secondary containment surrounding the Rolloff tank. The water exhibited conductivity within normal range. Two puddles on the pad service were also screened for conductivity and found to be within normal range.

No violations were noted. I departed the site at 1315 hours.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2494025 761714 2016-05-17 2016-06-08 78.54 Environmental Health & Safety An administrative report was generated for the SWEPI LP – Watkins 820 site in Chatham Twp., Tioga Co. (ESX11-117-0019). Sample results collected 5/17/2016 indicate the presence of a pollution substance on the ground outside of containment. This constitutes a violation of 25 Pa. Code 78.45 (relatin

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
761714 343948 NOV - Notice of Violation 2016-09-02

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 10/18/2014 10/18/2014 10859 4,576,930.0 32110

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 100 Mesh, Bulk (over 20K lbs)* Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 3.32617 1,447,180.0
SI-7 (Scale Inhibitor) Trican Scale Inhibitor Ethylene Glycol 107-21-1 30 0.008354 3634.91
FR-15 (Friction Reducer) Trican Friction Reducer Alcohols, C12-16, ethoxylated 68551-12-2 5 0.004779 2079.31
Mineral oil/ light hydrotreated pet. distillate 64742-47-8 25 0.023895 10396.5
Proprietary Amide Proprietary 2.5 0.00239 1039.65
Water Customer Carrier Water 7732-18-5 100 87.7897 38,196,300.0
Other Chemicals Copolymer of acrylamide-AETAC 69418-26-4 0 0 0
Water 7732-18-5 0 0 0
Organic acid derivatives Proprietary 0 0 0
Sorbitan monooleate 1338-43-8 0 0 0
Inorganic phosphate 7632-05-5 0 0 0
Sodium Chloride 7647-14-5 0 0 0
Trade Secret Proprietary 0 0 0
MBC 516 (Biocide) Trican Biocide Ethanol 64-17-5 2.8 0.000633 275.534
Didecyl dimethyl ammonium chloride 7173-51-5 8.3 0.001877 816.76
N-alkyl dimethyl benzyl ammonium chloride 68424-85-1 5.5 0.001244 541.227
Gluteraraldehyde 111-30-8 27 0.006107 2656.93
15% HCL Trican Carrier Hydrochloric acid 7647-01-0 15 0.098852 43009.3
AI-7NR (Acid Inhibitor) Trican Acid Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00002500 10.7188
White 40/70 Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 8.07665 3,514,060.0

For data sources see[7]

References