37-115-21140

Well Details

Well ID: 37-115-21140
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: New Milford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 144552
Farm/Lease Name: FOLGER 2H
License Status: Active
Spud Date: 11/23/2011
Permit Date: 2/4/2013
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.827636
Longitude: -75.742419

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 SOUTHWESTERN ENERGY PROD CO 568,986.00 122 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 1,516,025.00 362 0.00 0 0.00 0
2015 SOUTHWESTERN ENERGY PROD CO 1,018,651.00 365 0.00 0 0.00 0
2016 SWN PROD CO LLC 792,427.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 480,143.00 364 0.00 0 0.00 0
2018 SWN PROD CO LLC 461,625.00 334 0.00 0 0.00 0
2019 SWN PROD CO LLC 128,710.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
16DECU Produced Fluid (in Barrels) RWC 802 69.50 Bbl REUSE OTHER THAN ROAD SPREADING
16FEBU Produced Fluid (in Barrels) RWC 802 2.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JANU Produced Fluid (in Barrels) RWC 802 1.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JULU Produced Fluid (in Barrels) RWC 802 1.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JUNU Produced Fluid (in Barrels) RWC 802 1.00 Bbl REUSE OTHER THAN ROAD SPREADING
16NOVU Produced Fluid (in Barrels) RWC 802 28.00 Bbl REUSE OTHER THAN ROAD SPREADING
16OCTU Produced Fluid (in Barrels) RWC 802 57.00 Bbl REUSE OTHER THAN ROAD SPREADING
16SEPU Produced Fluid (in Barrels) RWC 802 29.50 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Drill Cuttings (in Tons) 607.53 Tons LANDFILL 101247
2013-1 Fracing Fluid Waste (in Barrels) 3,116.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Drill Cuttings (in Tons) 26.53 Tons LANDFILL 101247
2013-2 Fracing Fluid Waste (in Barrels) 5,082.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Produced Fluid (in Barrels) 3,012.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 469.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 38.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 471.75 Bbl REUSE OTHER THAN ROAD SPREADING
2016-01 Produced Fluid (in Barrels) RWC 802 1.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-02 Produced Fluid (in Barrels) RWC 802 2.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-06 Produced Fluid (in Barrels) RWC 802 1.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-07 Produced Fluid (in Barrels) RWC 802 1.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-09 Produced Fluid (in Barrels) RWC 802 29.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-10 Produced Fluid (in Barrels) RWC 802 57.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-11 Produced Fluid (in Barrels) RWC 802 28.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-12 Produced Fluid (in Barrels) RWC 802 69.50 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Produced Fluid (in Barrels) RWC 802 220.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-02 Produced Fluid (in Barrels) RWC 802 389.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-03 Produced Fluid (in Barrels) RWC 802 204.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-05 Produced Fluid (in Barrels) RWC 802 116.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-06 Produced Fluid (in Barrels) RWC 802 114.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-07 Other Oil & Gas Wastes (in Barrels) RWC 899 26.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-07 Produced Fluid (in Barrels) RWC 802 28.75 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-08 Produced Fluid (in Barrels) RWC 802 55.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-10 Produced Fluid (in Barrels) RWC 802 28.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-11 Other Oil & Gas Wastes (in Barrels) RWC 899 23.75 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-11 Produced Fluid (in Barrels) RWC 802 57.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-01 Other Oil & Gas Wastes (in Barrels) RWC 899 28.75 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-01 Produced Fluid (in Barrels) RWC 802 56.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-02 Other Oil & Gas Wastes (in Barrels) RWC 899 21.73 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-02 Produced Fluid (in Barrels) RWC 802 55.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-03 Produced Fluid (in Barrels) RWC 802 56.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-04 Other Oil & Gas Wastes (in Barrels) RWC 899 27.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-04 Produced Fluid (in Barrels) RWC 802 65.00 Bbl SURFACE IMPOUNDMENT 826342
2018-05 Other Oil & Gas Wastes (in Barrels) RWC 899 27.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-05 Produced Fluid (in Barrels) RWC 802 28.25 Bbl SURFACE IMPOUNDMENT 826342
2018-07 Produced Fluid (in Barrels) RWC 802 111.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-08 Other Oil & Gas Wastes (in Barrels) RWC 899 72.35 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-08 Produced Fluid (in Barrels) RWC 802 83.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-09 Produced Fluid (in Barrels) RWC 802 70.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-10 Produced Fluid (in Barrels) RWC 802 28.50 Bbl REUSE (AT WELL PAD)
2018-11 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-12 Produced Fluid (in Barrels) RWC 802 30.00 Bbl REUSE (AT WELL PAD)
2019-01 Other Oil & Gas Wastes (in Barrels) RWC 899 3.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-01 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-02 Produced Fluid (in Barrels) RWC 802 27.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-03 Other Oil & Gas Wastes (in Barrels) RWC 899 12.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-03 Produced Fluid (in Barrels) RWC 802 30.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2152521 Primary Facility 03/29/2013 Routine/Partial Inspection No Violations Noted
2173999 Primary Facility 05/07/2013 Drilling/Alteration No Violations Noted 20-76'
2208531 Primary Facility 09/24/2013 Incident- Response to Accident or Event Violation(s) Noted On 9/24/13 at 11:05 AM SWN contacted the Department to report a release of approximately 105 gallons of ethylene glycol to the pad surface of the SWN RU 32 Folger Pad. Reported cause of release was a production equipment problem. Arrived on-site at approximately 12:30 PM. Mike Deming was on-site and explained that a well tender had identified the spill while responding to an automatic shut in of the Folger 2H (permit # 115-21140). The production unit which services the 2H had malfunctioned and overheated causing the fluid loss to the pad surface under the unit. The equipment failure caused the well and unit to automatically shut down. Equipment is being brought in to begin the cleanup of the spill. Explained to Mike that this case would probably be referred to the Department’s EC&B Program.
2208798 Primary Facility 09/24/2013 Routine/Complete Inspection No Violations Noted Refer to inspection ID # 2208782
2260926 Primary Facility 04/08/2014 Routine/Complete Inspection No Violations Noted On 4/8/14, the Department conducted a follow-up inspection of SWN RU 32 Folger Pad where violations had been noted by the Department during a 9/24/13 inspection. The cut slope has been effectively stabilized. As of this inspection, violations noted in the 9/24/13 inspection have been corrected/abated.
2359312 Primary Facility 04/07/2015 Routine/Complete Inspection No Violations Noted
2477438 Primary Facility 2016-04-22 Routine/Complete Inspection No Violations Noted
2488554 Primary Facility 2016-05-31 Routine/Complete Inspection No Violations Noted
2558044 Primary Facility 2017-02-01 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 15:25p.m., the cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the production tank was closed. There was 590psi on the production casing and 504psi on the production line. I took a walk around the location and noticed that the entire site was covered with snow except a section between the production tanks and the production units. I contacted Gene Rickard (DEP WQS) to let him know about the well site.

I left the site at 16:05p.m.

2564075 Primary Facility 2017-02-02 Routine/Complete Inspection No Violations Noted Today’s inspection was conducted after a Department Oil and Gas Inspector noticed a large area of unfrozen standing water on the well pad surface near the production tanks and production units. The unfrozen water is unusual in respect to the fact that recent and current temperatures have been and are well below freezing. The Department employed an Extech Instruments ExStik 2 Conductivity Meter, tested the water and found the conductivity to be around 90 microsiemens, a relatively low number. Of note is the fact that algae was present and thriving in the standing water. The presence of the algae suggests that the water is probably an expression of ground water which would also explain the temperatures recorded of the standing water of 9 degrees Celsius. Overall, the pad site looked good with no E&S violations observed.
2564094 Primary Facility 2017-02-06 Routine/Complete Inspection No Violations Noted Today’s inspection is being conducted after having consulted with a Department Geologist and a Department Oil and Gas Inspector in reference to the standing water observed on the SWN RU 32 Folger Pad. The consensus was that it would be prudent for the Department to collect samples, soil and water, of the standing unfrozen water and associated contact soil on the pad to ensure that the presence of the standing unfrozen water is a natural phenomenon. Present during the inspection was myself, Jon Sassi, Department EPS, Eric Rooney, Department LPG, David Schoonover, Department OGI, and Mike Deming, SWN Senior Regulatory Analyst. Mr. Deming did state that SWN has always been aware of the standing water and that its presence has been attributed to the theory that the water is a natural expression of ground water. The Department collected 3 separate samples, one soil sample and two water samples. The soil sample, 0257238, will be tested for glycol and methanol. One of the water samples, 0257239 will be tested
2651853 Primary Facility 2017-10-25 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violation noted.

2753335 Primary Facility 2018-07-18 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2855698 Primary Facility 2019-03-19 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 3/4/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2208531 679315 09/24/2013 10/31/2013 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety NERO EC&B granted Alt Rem Rev memo 10/31/13, MBC data clean-up 4/15/15. Spill of 120 gallons ethylene glycol to well pad surface
2208531 682088 09/24/2013 10/31/2013 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety NERO EC&B granted Alt Rem Rev memo 10/31/13, MBC data clean-up 4/15/15. SWMA 6018.610 Ethylene glycol was allowed to impact the surface of the ground
2208531 682090 09/24/2013 10/31/2013 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution Environmental Health & Safety NERO EC&B granted Alt Rem Rev memo 10/31/13, MBC data clean-up 4/15/15. Spill of 120 gallons ethylene glycol to well pad surface

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
679315 302928 NOV - Notice of Violation Comply/Closed 10/31/2013
682088 302928 NOV - Notice of Violation Comply/Closed 10/31/2013
682090 302928 NOV - Notice of Violation Comply/Closed 10/31/2013

For data sources see[6]