X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-099-22811

Well Details

Well ID: 34-099-22811
Loading map...
County: Mahoning
Municipality:
Operator Name: EVERFLOW EASTERN PTNS L P
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1998-10-09
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.05400141
Longitude: -80.65762282

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1998-0 0.0 0.0
1999-0 23659.0 67.0
2000-0 20911.0 72.0
2001-0 17497.0 47.0
2002-0 9255.0 0.0
2003-0 9498.0 21.0
2004-0 6377.0 25.0
2005-0 5408.0 20.0
2006-0 10641.0 38.0
2007-0 7953.0 30.0
2008-0 9644.0 20.0
2009-0 7851.0 8.0
2010-0 5295.0 0.0
2011-0 10082.0 18.0
2012-0 8382.0 13.0
2013-0 8939.0 12.0
2014-0 6942.0 260.0 0.0 260.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1084191817 2004-01-20 The tank battery consists of: 2-100 bbl storage tanks, 1-50 bbl salt water tank, 3-separators and a dike. The tank battery is shared with permits: 2951 and 2541.
-1336209423 2012-02-02 I conducted a status check on this site and found that the well head was fenced with chain link, and it is equipped with a plunger lift system. The tank battery consists of one 100 barrel stock tank, and three separators, no brine storage tank present. The thief hatch was closed and there was a bull plug installed in the draw valve. The tank battery was fenced with chain link, and the dike was free of vegetation and debris. The tank battery is shared with permits 2951, and 2541. Proper identification was posted, and I found no leaks or spills at the well head or the tank battery. I took new GPS coordinates of the well head and tank battery. No violations at this time.
145599317 2007-11-14 I preformed a random field inspection. GPS'd the well and the tank battery. ID signs were posted. The tank battery was in very good shape. I found no violations at this time.
-365187173 2012-09-11 On 9/11/2012, I performed a status check on the above well site. The tank battery is equipped with one, 100 barrel tank and one, horizontal separator. This is a plunger lift with 1.5 tubing. There is 0 psi on the 8.625. Identification signs are posted. No violation were noted at this time.
iDIAN001369 1999-04-30

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 