X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-099-22930

Well Details

Well ID: 34-099-22930
Loading map...
County: Mahoning
Municipality:
Operator Name: OHIO VALLEY ENERGY SYSTEM CORP
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2002-08-07
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.02712139
Longitude: -80.71121104

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2003-0 39972.0 87.0
2004-0 25307.0 58.0
2005-0 18056.0 38.0
2006-0 12553.0 0.0
2007-0 14774.0 0.0
2008-0 17008.0 53.0
2009-0 11283.0 0.0
2010-0 10905.0 0.0
2011-0 7714.0 0.0
2012-0 11236.0 0.0
2013-0 8758.0 0.0
2014-0 7429.0 365.0 0.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1130182546 2003-06-04 Meets requirements for preliminary restoration. There is a dike, 1-100bbl and 1-separator.
-1140708046 2007-05-03 This inspection was due to the Boardman Township Fire Departments request. Well and tank battery were GPS'd Pine trees surround the tank battery. ID sign was posted. No violations at this time
1216i979 2002-10-18 Pits closed.
1328902096 2012-02-07 I conducted a status check on this site and found that the well head was fenced with chain link, and it is equipped with a plunger lift system. The tank battery consists of one 100 barrel stock tank equipped with flash arrestor and charcoal filter, and one separator, no brine storage tank present. The thief hatch was closed and there was a bull plug installed in the draw valve. The tank battery was fenced with chain link, and the dike was free of vegetation and debris. Proper identification was posted, and I found no leaks or spills at the well head or tank battery. I took new GPS coordinates of the well head and tank battery. No violations at this time.
1356366439 2012-12-19 On 12/19/2012, I performed a status check on the above location. The tank battery consist of one 140 barrel tank, one horizontal separator. The well is a 1.5' plunger lift. I D. signs are posted, dike is in good condition. No violations were noticed at this time.
1705791064 2010-10-13 I performed a random field inspection. I GPS'd both the tank battery and the wellhead. I continued to walk around both the wellhead and the tank battery. This inspection satisfies 1501:9-9-05. There were no violations at this time.
89877686 2002-08-29 Pits are now closed.

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 