34-031-27221

Well Details

Well ID: 34-031-27221
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2014-01-09
Unconventional:
Horizontal:
Producing: No
Violations: 0
Latitude: 40.1886761761
Longitude: -82.1521718864

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-109178416 2014-02-06 On the day of my inspection I found that Wheeler Drilling was drilling at a depth of 2310' with a 6.5" bit. The permit was posted and I found no leaks or spills. There were no sags or tears in the pit liner.
-1385716914 2014-02-20 On the day of my inspection I found that Wheeler Drilling was drilling at a depth of 2860' with a 6.5" bit. The permit was posted and I found no leaks or spills. There were no sags or tears in the pit liner.
-1390914943 2013-12-23 On the day of my inspection I found that Wheeler Drilling was rigged up but not drilling. They had not spudded the well yet. The lease road was still under construction.
-179221657 2014-01-10 On the day of my inspection I found that Wheeler Drilling had set 45' of 11.75" conductor. They were drilling at a depth of 60' with a 10.875" bit. The permit was posted and I found no leaks or spills. There were no sags or tears in the pit liner. No violations at this time.
1049865265 2014-02-27 On the day of my inspection I found that Wheeler Drilling was drilling at a depth of 3040' with a 6.5" bit. The permit was posted and I found no leaks or spills. There were no sags or tears in the pit liner.
1051810004 2014-03-05 On the day of my inspection I found that Wheeler Drilling had set 3084' of used, tested and drifted 4.5" casing cemented with 55 sacks of class A cement by Cemenco on 3/3/14. There were no sags or tears in the pit liner and I found no leaks or spills around the drill site.
1389023705 2014-01-06 On the day of my inspection I found that Wheeler Drilling was not drilling. The well will tentatively be spudded on Jan 8, 2014. The drilling operation is currently on hold due to inclement weather.
1389816109 2014-01-15 On the day of my inspection Wheeler Drilling ran 473' of used, tested and drifted 8.625" casing. Cemenco pumped 500 lbs of gel and 100 lbs of cotton seed hulls, followed by 135 sacks of class A cement. Circulation was established during displacement and was maintained through the remainder of the job. There were approximately 20 barrels of cement returns.
1389881290 2014-01-16 On the day of my inspection I witnessed the surface casing pressure test. The casing was pressured up to 300 psi and shut in for 30 minutes. Approximately 28 psi was lost during the test. The casing passed. Mackenco was authorized to resume drilling operations.
1390315887 2014-01-21 On the day of my inspection I found that Wheeler Drilling ran new 7" intermediate casing to 883'. Cemenco power-mudded the casing to surface. The permit was posted, there were no sags in the pit liner and I found no leaks or spills.
1390920801 2014-01-27 On the day of my inspection I found that Wheeler Drilling was drilling at a depth of 1500' with a 6.5" bit. The permit was posted and I found no leaks or spills. There were no sags or tears in the pit liner. No violations at this time.
1661613488 2013-12-12 On the day of my inspection I found that the location and lease road were cut. Wheeler Drilling was moving the drilling equipment into position, preparing to rig up. The drilling pit was not dug.
172215884 2014-02-12 On the day of my inspection I found that Wheeler Drilling was drilling at a depth of 2600' with a 6.5" bit. The permit was posted and I found no leaks or spills. There were no sags or tears in the pit liner.