Well Details

Well ID: 34-083-24603
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2013-10-17
Unconventional:
Horizontal:
Producing: No
Violations: 0
Latitude: 40.2889016359
Longitude: -82.306735175

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1110738654 2013-11-14 Drilling during inspection 1020 feet no violations.
-1278618478 2014-02-21 Running tubing and packer today, with inspectors Thomas Benko and Tom Zacharyasz.
-1298694805 2013-12-30 Inspect Drill site. Operator installed 4.5 inch long string with 15 centralizers. Set a Sit-down packer at 2375 feet with 120 feet of 4.5 inch pipe with multiple slots below packer and two Flapper valves above the packer. Cemenco Services Inc. pumped 20 sacks of gel were run ahead of 180 sacks of cement. Cement displaced with rubber plug.
-1378601857 2014-09-02 Inspect facility. The pump was in operation during inspection.
-146156591 2014-02-24 Add inhibitor today tried to check pressure to much foam retry tomorrow.
-1471339562 2013-10-21 Drilling surface 204 feet deep no violations.
-1494276043 2013-12-26 Inspect well. Drilling is complete Total depth 2496 feet. Newburg at 2470 feet, Berea at 720 to 729 feet. Appalachian Well Surveys conducted an open hole log on the well.
-14961756 2014-05-29 Inspect well and facility at the request of the operator. Test injection line from pump house to this well. After tightening several fittings the line held pressure with no loss at 570 psi.
-1650094021 2013-11-05 Drilling 630 feet no violations.
-207197643 2014-08-21 Inspect well for pressure and integrity. Pump operating and well in production during inspection.
1164144926 2013-11-24 1430 feet no violations.
1293261664 2014-04-10 Inspect well for integrity and pressure. The drill rig is currently set up on well. The flow line has been laid and tied into the injection line. The line has not been connected to the pump house at the Moran #1. The valve for the annulus is open.
1375273575 2014-02-25 Tried pressure test again today, pressure held, acid injection treatment completed, see Inspector Thomas Benko's for detailed information.
1387472128 2013-12-19 Drilling during inspection 2400 feet hole still dry no violations.
1388494661 2013-12-30 Ran 4 1/2 casing today and cemented, with Tom Benko and Brittney Hupp. Cemenco on site for cementing.
1393170991 2014-02-21 Inspect well. Operator requested to install packer and tubing. New packer and used tubing tested to 3000 psi installed into well and hung on slips. Water with inhibitor will be circulated at a later date.
1500717730 2014-09-04 Inspect facility. Pump in operation during inspection.
174375808 2014-02-25 Inspect Well. Operator set up service rig on well to test the integrity of the 5.5 inch casing using the packer and tubing currently set in the well at various depts. Operator believed the perforations into the Utica Shale from 3788 feet to 3800 feet that were squeezed with cement prior to SWIW conversion were the cause of the pressure leak off on the packer and tubing. The packer was set and pressure tested at two depths above and below the perforations at 3762 feet and 3833 feet and loaded with water and pressured up to 1100 psi. There was no pressure loss at these depths. The Utica Shale Perforations are not causing the leak off. The operator set the packer and tested at two depth below a 5.5 inch cementing diversion (DV) tool set at 4100 feet. The depths tested were at 4143 feet and 4146 feet. The annulus was then pressured up to 1100 psi and shut in. The pressure rapidly leaked off. The determination was made that the DV tool has communication with the formation below 4100 feet and was not completely cemented off during installation and cementing of the 5.5 inch casing. A Cement bond log was performed July 11, 2013. the log indicates good cement above 4100 feet and no cement below this depth.
1940403574 2013-11-26 Inspect drill site. Current drilling depth at 1640 feet.
1972707639 2014-07-08 Inspect well for integrity and pressure. Well is shut in. The drilling pit is open.
2122131749 2014-02-25 Inspect well and test for mechanical casing integrity. One joint of tubing was pulled and the parmaco packer was set at 2337 feet below grade. Top annulus with water and inhibitor. Pressure test well at 700 psi. Test Passed. Operator pumped 100 gallons of 15% hydrochloric acid into injection zone to clean up formation.
229705780 2014-02-24 Inspect well. Operator has installed 4.5 inch Parmaco packer and 2 3/8 inch tubing in well. Cemenco onsite to circulate fresh water with inhibitor through the tubing. The packer was set and well pressure tested. The pressure test failed. The pressure leaked off due to foam and air bubbles. Testing rescheduled for next day.