If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-031-23473 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.3979795471,"lon":-81.7956367831,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1979-03-09 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 1 | |
Latitude: 40.3979795471 | |
Longitude: -81.7956367831 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1689501760 | 2013-03-20 | I received a request to inspect this well from landowner Carl McCoy (740-545-9920). On the day of my inspection I met Mark Fluharty of Northwood energy at the former well site. This well was plugged on 9/29/09 and the final restoration was passed on 10/5/09 by ODNR inspector Rocky King. Mr. McCoy was concerned with a meter near the old well site. Mark Fluharty claimed that the meter did not belong to Northwood Energy, it was used in the past by another company to supply gas to the nearby home. | ||||
-2023450264 | 2009-02-20 | Well disconnected from lead line . There are no storage tanks at site . Well has 2.7/8 casing shut in with valve at surface . There is no identification at well . | NONE | |||
-307482566 | 2009-05-26 | No change in well condition , well is idle shut in , no lead line or storage tank . Will call Mark with company to find out plans for well if there are no plans will request chiefs order to plug . | ||||
1253113828 | 2009-09-16 | Trying to plugged back to Oriskany formation if not productive will plug to surface . | ||||
1253641137 | 2009-09-22 | Ran 383' of 7" inside of 8" casing , 8" parted @ 40' . Cemented 7" casing back to surface . Going to drill bridge out and log Oriskany formation . If not productive well will be plugged back to surface . | ||||
1254231484 | 2009-09-29 | Plug to surface . Cemenco , Davis well service . | ||||
1286225130 | 2010-10-05 | Final restoration passed. |