PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-2011669052 2013-03-15 Jet Wire Line cut the tubing at a depth of 4038'. The cement top was at 4048'. The service rig crew is pulling the tubing.
-2089890117 2007-02-15 No change in status of well,owner has valid plug permit issued 11/30/06 in conversation with owner stating they were on service rig contractors list for service work needed. 9-9-05(A)10
-2089890117 2007-02-15 No change in status of well,owner has valid plug permit issued 11/30/06 in conversation with owner stating they were on service rig contractors list for service work needed. NONE
-2089890117 2007-02-15 No change in status of well,owner has valid plug permit issued 11/30/06 in conversation with owner stating they were on service rig contractors list for service work needed. NONE(B)
-2127596974 2013-03-27 I am onsite to check the casing for pressure test certification and to cement it in place. The service rig ran 2399' of 10.5# casing and Formation is on site to cement it in place with 190 sks of class A cement.
-860217450 2013-03-14 My inspection today finds the well is equipped with 4.5" casing and 2.375" tubing on a packer. The service company is unable to release the packer. An attempt to cut the pipe at 5415' failed, the tubing was not free. Another attempt cut was made. Jet Wire Line tried to cut the tubing again but could only get to a depth of 4873' they tried to bust a collar at that depth. The pipe was still not free. Cemenco tried to pump on the tubing and gain circulation, but they could not. Cemenco set a 30 sk plug at 4873'.
1177195934 2007-04-16 No change in status of well, it is still idle in conversation with company rep Bruce Kimbel stating they were waiting on service rig to plug said well.
1289489149 2013-03-20 Jet Wire Line perforated the casing at 4030' the previous day. Cemenco is onsite to set a 50sk plug at 4030'. Jet cut the casing at a depth of 2724'. The pipe is not free. The rig crew will continue to try to pull the pipe.
1363994615 2013-03-15 The plugging contractor ran the sand line to a depth of 4048' to check the top of the cement. Jet Wire Line cut the tubing at 4038'.
1364308485 2013-03-26 Cemnco is onsite to set a rip plug (57 sks of class A). Plug is placed at 2700' to 2500'.
1443191691 2006-11-13 Upon inspecting site along with landowner Phillip Saling found well to be idle last production reported in 2000 suspect hole in casing H2S odor noted well is equipped with 8" surface casing and 4.5" production casing and 1.5" tubing and 1-100 bbl tank in need of proper dike,no I.D.could be found for said well. 9-9-05(A)10
1443191691 2006-11-13 Upon inspecting site along with landowner Phillip Saling found well to be idle last production reported in 2000 suspect hole in casing H2S odor noted well is equipped with 8" surface casing and 4.5" production casing and 1.5" tubing and 1-100 bbl tank in need of proper dike,no I.D.could be found for said well. NONE
1443191691 2006-11-13 Upon inspecting site along with landowner Phillip Saling found well to be idle last production reported in 2000 suspect hole in casing H2S odor noted well is equipped with 8" surface casing and 4.5" production casing and 1.5" tubing and 1-100 bbl tank in need of proper dike,no I.D.could be found for said well. NONE(B)
1972207752 2009-01-20 Inspection revealed that well is back into production, noted domestic hookup and commercial sales line located along county rd 8 south of Sharon.