INSPECTION ID
|
DATE
|
DESCRIPTION
|
COMMENT
|
VIOLATION ID
|
VIOLATION CODE
|
VIOLATION_COMMENT
|
-1386970195
|
2012-11-01
|
|
Inspect well. Site ok. Rabbit well on 1.5 inch tubing.
|
|
|
|
-1388129223
|
2014-05-07
|
|
Inspection to witness top up of surface plug with grout. Cement was tagged at 117ft down. The well was filled from surface with 9 sack grout. See the plug report for details.
|
|
|
|
-1549280622
|
2014-05-06
|
|
Inspection to witness surface plug.
|
|
|
|
-580872277
|
2014-05-05
|
|
Inspection to witness bottom through Berea plugging of the well. See the plug report for details.
|
|
|
|
-675728790
|
2011-03-29
|
|
Well is in production and equipped with rabbit and tubing. 1-100 barrel tank and separator in battery. Sun, 40 degrees.
|
|
|
|
-869161998
|
2014-04-30
|
|
The operator has a plug permit on the well. The operator advised that plugging would start Thursday or Friday this week. Columbia Gas personnel were on site disconnecting sales line from the well. Portable tanks have been dropped at the well location. The operator has to dig pits yet. There is a Columbia Gas Transmission line near the well. The operator needs approval from Columbia Gas engineers to work in the vicinity of the line. They may have to build a pad over the line or place protective mats over it.
|
|
|
|
1399044598
|
2014-05-02
|
|
Utilities have been marked. The operator hasn't moved any machinery onto the location yet. Per last contact they were going to start plugging on Monday, 5/5/14.
|
|
|
|
514856756
|
2014-05-08
|
|
The operator cut off the drive pipe below grade. The tank battery is removed and the production equipment is removed. The pit has been backfilled. The location has been finish graded, seeded and mulched. Final restoration is approved.
|
|
|
|