X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-081-21026"

m
m
Line 265: Line 265:
 
|-
 
|-
 
| 2017
 
| 2017
| [[ANADARKO E&P ONSHORE LLC]]
+
| [[ARD OPR LLC]]
 
| style="text-align: right;" | 192,247.91
 
| style="text-align: right;" | 192,247.91
 
| style="text-align: right;" | 362
 
| style="text-align: right;" | 362
Line 301: Line 301:
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Period
 
!scope="col" | Period
 +
!scope="col" | Operator
 
!scope="col" | Waste Type
 
!scope="col" | Waste Type
 
!scope="col" | Quantity
 
!scope="col" | Quantity
Line 306: Line 307:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2012-S02
+
| 2012
 +
| [[ANADARKO E&P ONSHORE LLC]]
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 25.70 Tons
 
| style="text-align: right;" | 25.70 Tons
Line 312: Line 314:
 
| 100955
 
| 100955
 
|-
 
|-
| 2013-S01
+
| 2013
 +
| [[ANADARKO E&P ONSHORE LLC]]
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 932.09 Tons
 
| style="text-align: right;" | 932.09 Tons
Line 318: Line 321:
 
| 301626
 
| 301626
 
|-
 
|-
| 2014-S01
+
| 2014
 +
| [[ANADARKO E&P ONSHORE LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 6,052.96 Bbl
+
| style="text-align: right;" | 7,875.91 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2014-S02
+
| 2015
| Produced Fluid (in Barrels)
+
| [[ANADARKO E&P ONSHORE LLC]]
| style="text-align: right;" | 1,822.95 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,004.95 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2015-S02
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 41.13 Bbl
 
| style="text-align: right;" | 41.13 Bbl
Line 342: Line 335:
 
| WMGR119
 
| WMGR119
 
|-
 
|-
| 2015-S02
+
| 2015
 +
| [[ANADARKO E&P ONSHORE LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 159.42 Bbl
 
| style="text-align: right;" | 159.42 Bbl
Line 348: Line 342:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2016-M09
+
| 2015
| Produced Fluid (in Barrels) RWC 802
+
| [[ANADARKO E&P ONSHORE LLC]]
| style="text-align: right;" | 103.63 Bbl
+
| Produced Fluid (in Barrels)
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
| style="text-align: right;" | 1,004.95 Bbl
| WMGR119
+
| REUSE OTHER THAN ROAD SPREADING
|-
 
| 2016-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 69.00 Bbl
 
| STORAGE PENDING DISPOSAL OR REUSE
 
 
|  
 
|  
 
|-
 
|-
| 2016-M12
+
| 2016
 +
| [[ANADARKO E&P ONSHORE LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 36.00 Bbl
+
| style="text-align: right;" | 102.00 Bbl
| STORAGE PENDING DISPOSAL OR REUSE
 
|
 
|-
 
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 89.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123NW005
 
|-
 
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 259.00 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR119
 
|-
 
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2016-S02
+
| 2016
 +
| [[ANADARKO E&P ONSHORE LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 52.00 Bbl
+
| style="text-align: right;" | 362.63 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR123
+
| WMGR119
 
|-
 
|-
| 2017-M02
+
| 2016
 +
| [[ANADARKO E&P ONSHORE LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 13.00 Bbl
+
| style="text-align: right;" | 89.00 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| WMGR123NC010
+
| WMGR123NW005
 
|-
 
|-
| 2017-M04
+
| 2016
 +
| [[ANADARKO E&P ONSHORE LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 16.00 Bbl
+
| style="text-align: right;" | 105.00 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| STORAGE PENDING DISPOSAL OR REUSE
| WMGR123NC010
+
|  
 
|-
 
|-
| 2017-M09
+
| 2017
 +
| [[ARD OPR LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 16.00 Bbl
+
| style="text-align: right;" | 34.00 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| REUSE (AT WELL PAD)
| WMGR123NC010
+
|  
 
|-
 
|-
| 2017-M10
+
| 2017
 +
| [[ARD OPR LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 7.00 Bbl
 
| style="text-align: right;" | 7.00 Bbl
Line 414: Line 391:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2017-M10
+
| 2017
 +
| [[ARD OPR LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 20.00 Bbl
+
| style="text-align: right;" | 65.00 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2017-M12
+
| 2018
| Produced Fluid (in Barrels) RWC 802
+
| [[ARD OPR LLC]]
| style="text-align: right;" | 34.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 16.77 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 14.00 Bbl
 
| REUSE (AT WELL PAD)
 
|  
 
|-
 
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 23.13 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 3.57 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M10
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 7.76 Bbl
+
| style="text-align: right;" | 65.23 Bbl
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  

Revision as of 17:49, 21 August 2019

Well Details

Well ID: 37-081-21026
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Cascade Township
Operator Name: ARD OPR LLC
Well Pad ID: 146784
Farm/Lease Name: SALT RUN HC A 5H
License Status: Active
Spud Date: 2012-11-02
Permit Date: 2012-09-13
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.468422
Longitude: -76.869242

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-10-20 2013-11-01 8011 3,460,320.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-15 Trican Well Service Friction Reducer Proprietary Amide Proprietary 2.5 0.00184658 644.63
Paraffinic, Naphthenic Solvent 64742-47-8 25 0.0184658 6446.3
Water Anadarko Carrier/Base Fluid Water 7732-18-5 100 82.7178 28,876,300.0
Sand (Proppant) Trican Well Service Proppant Quartz 14808-60-7 99 16.1941 5,653,260.0
Hexamethylenetretramine 100-97-0 1 0.163576 57103.6
FEAC-20 Trican Well Service Iron Control Acetic Acid 64-19-7 50 0.00361057 1260.43
Citric Acid 77-92-9 30 0.00216634 756.257
Bio-Clear 1000 Trican Well Service Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 98 0.000109483 38.22
Hydrochloric Acid (7.5%) Trican Well Service Acidizing Water 7732-18-5 92.5 0.735882 256892
Hydrochloric Acid 7647-01-0 7.5 0.0596661 20829.1
Aqucar DB 5 Trican Well Service Biocide Sodium bromide 7647-15-6 1.5 0.000670921 234.215
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 5 0.0022364 780.716
Polyethylene glycol 25322-68-3 65.2 0.0291627 10180.5
Dibromoacetonitrile 3252-43-5 50 0.022364 7807.17
AI-7NR Trican Well Service Corrosion Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00003060 10.682

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2013 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2014 ANADARKO E&P ONSHORE LLC 1,701,352.00 336 0.00 0 0.00 0
2015 ANADARKO E&P ONSHORE LLC 438,142.00 192 0.00 0 0.00 0
2016 ANADARKO E&P ONSHORE LLC 373,038.00 365 0.00 0 0.00 0
2017 ARD OPR LLC 192,247.91 362 0.00 0 0.00 0
2018 ARD OPR LLC 146,291.24 357 0.00 0 0.00 0
2019 ARD OPR LLC 32,792.58 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 ANADARKO E&P ONSHORE LLC Drill Cuttings (in Tons) 25.70 Tons LANDFILL 100955
2013 ANADARKO E&P ONSHORE LLC Drill Cuttings (in Tons) 932.09 Tons LANDFILL 301626
2014 ANADARKO E&P ONSHORE LLC Produced Fluid (in Barrels) 7,875.91 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ANADARKO E&P ONSHORE LLC Produced Fluid (in Barrels) 41.13 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 ANADARKO E&P ONSHORE LLC Produced Fluid (in Barrels) 159.42 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 ANADARKO E&P ONSHORE LLC Produced Fluid (in Barrels) 1,004.95 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ANADARKO E&P ONSHORE LLC Produced Fluid (in Barrels) RWC 802 102.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 ANADARKO E&P ONSHORE LLC Produced Fluid (in Barrels) RWC 802 362.63 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016 ANADARKO E&P ONSHORE LLC Produced Fluid (in Barrels) RWC 802 89.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 ANADARKO E&P ONSHORE LLC Produced Fluid (in Barrels) RWC 802 105.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 ARD OPR LLC Produced Fluid (in Barrels) RWC 802 34.00 Bbl REUSE (AT WELL PAD)
2017 ARD OPR LLC Produced Fluid (in Barrels) RWC 802 7.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 ARD OPR LLC Produced Fluid (in Barrels) RWC 802 65.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 ARD OPR LLC Produced Fluid (in Barrels) RWC 802 65.23 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2110490 Primary Facility 2012-10-23 Routine/Complete Inspection No Violations Noted
2116684 Primary Facility 2012-11-19 Drilling/Alteration No Violations Noted
2117093 Primary Facility 2012-11-14 Routine/Partial Inspection No Violations Noted
2138365 Primary Facility 2013-02-11 Routine/Complete Inspection No Violations Noted
2145963 Primary Facility 2013-03-07 Drilling/Alteration No Violations Noted
2146891 Primary Facility 2013-03-08 Routine/Complete Inspection No Violations Noted
2219646 Primary Facility 2013-11-05 Incident- Response to Accident or Event No Violations Noted VIOIC cited to 081-21025; 25 barrel brine spill to containment approx. 5 gallons off containment
2221225 Primary Facility 2013-11-13 Routine/Complete Inspection No Violations Noted
2568241 Primary Facility 2017-03-06 Routine/Complete Inspection No Violations Noted

Arrived @ 14:25. Weather: sunny, cold. There were 5 completed wells on location in a linear array. No personnel were onsite. Each well had two annular vents. The 9-5/8” x 5-1/2” annulus was fitted with a digital pressure gauge. The wells were not in production. A-5H: 5-1/2”: 1030 psi A-4H: 5-1/2”: 1041 psi A-3H: 5-1/2” : 1035 psi A-2H: 5-1/2”: 1037 psi A-1H: 5-1/2”: 1037 psi Left @ 14:35.

2785881 Primary Facility 2018-10-09 Routine/Complete Inspection No Violations Noted Five wells staged for production phase. Five each sand and water separators. Two separate sand and water separators. No leaks detected from production equipment. Methanol tank located near well heads. No violations noted.

For data sources see[7]

References