| Well ID: 37-111-20291 | | Well ID: 37-111-20291 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 40.033639, -79.184861 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 06 | + | | Spud Date: 2011-06-02 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2010-01-07 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2012-09-11 | ||
+ | | 2012-09-11 | ||
+ | | style="text-align: right;" | 7239.00 | ||
+ | | style="text-align: right;" | 5,851,923.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="13"| 1 | ||
+ | | rowspan="1"| ASP 900 | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Ammonium sulfate | ||
+ | | 7783-20-2 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| EC6673W | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Iron Control | ||
+ | | Ethylene glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.00676000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Proppant (lbs) | ||
+ | | rowspan="1"| | ||
+ | | rowspan="1"| Proppant | ||
+ | | | ||
+ | | | ||
+ | | style="text-align: right;" | 9.32 | ||
+ | | style="text-align: right;" | 10.36 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 7.5 Hcl Acid | ||
+ | | rowspan="1"| | ||
+ | | rowspan="1"| Used to open perfs | ||
+ | | Hydrochloric acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 7.50 | ||
+ | | style="text-align: right;" | 0.31 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| WG-36 GELLING AGENT | ||
+ | | rowspan="1"| Halliburton Energy Services | ||
+ | | rowspan="1"| Water Viscosifier | ||
+ | | Guar gum | ||
+ | | 9000-30-0 | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 0.00187000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| FR-66 Friction Reducer | ||
+ | | rowspan="1"| Halliburton Energy Services | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Distillates, petroleum, hydrotreated light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.03 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| EC6486A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.00704000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Clean Volume (gals) | ||
+ | | rowspan="1"| | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | | ||
+ | | | ||
+ | | style="text-align: right;" | 90.68 | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| Biocide EC 6116A | ||
+ | | rowspan="3"| Nalco | ||
+ | | rowspan="3"| Biocide | ||
+ | | 2,2-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.00676000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Polyethylene glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 60.00 | ||
+ | | style="text-align: right;" | 0.01 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5.00 | ||
+ | | style="text-align: right;" | 0.00113000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| GBW-30 BREAKER | ||
+ | | rowspan="2"| Halliburton Energy Services | ||
+ | | rowspan="2"| Gel Breaker | ||
+ | | Hemicellulase enzyme | ||
+ | | 9012-54-8 | ||
+ | | style="text-align: right;" | 15.00 | ||
+ | | style="text-align: right;" | 0.00011000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Carbohydrates | ||
+ | | | ||
+ | | style="text-align: right;" | 95.00 | ||
+ | | style="text-align: right;" | 0.00067000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 165: | Line 320: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | + | | 2011-S01 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2011- | ||
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 462.41 Tons | | style="text-align: right;" | 462.41 Tons | ||
Line 225: | Line 326: | ||
| 100081 | | 100081 | ||
|- | |- | ||
− | | 2011- | + | | 2011-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 130.00 Bbl | | style="text-align: right;" | 130.00 Bbl | ||
Line 231: | Line 332: | ||
| EPA ID: 748-163 | | EPA ID: 748-163 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 1,195.00 Bbl | | style="text-align: right;" | 1,195.00 Bbl | ||
Line 237: | Line 338: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 360.00 Bbl | | style="text-align: right;" | 360.00 Bbl | ||
Line 243: | Line 344: | ||
| | | | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 29.71 Tons | | style="text-align: right;" | 29.71 Tons | ||
Line 249: | Line 350: | ||
| 101421 | | 101421 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 825.00 Bbl | | style="text-align: right;" | 825.00 Bbl | ||
Line 255: | Line 356: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 8,438.00 Bbl | | style="text-align: right;" | 8,438.00 Bbl | ||
Line 261: | Line 362: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 7.24 Tons | | style="text-align: right;" | 7.24 Tons | ||
Line 267: | Line 368: | ||
| 100419 | | 100419 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 3,890.50 Bbl | | style="text-align: right;" | 3,890.50 Bbl | ||
Line 273: | Line 374: | ||
| | | | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 1.50 Tons | | style="text-align: right;" | 1.50 Tons | ||
Line 279: | Line 380: | ||
| 100419 | | 100419 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 5,226.00 Bbl | | style="text-align: right;" | 5,226.00 Bbl | ||
Line 285: | Line 386: | ||
| | | | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 270.42 Tons | | style="text-align: right;" | 270.42 Tons | ||
Line 291: | Line 392: | ||
| 100172 | | 100172 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 10.51 Tons | | style="text-align: right;" | 10.51 Tons | ||
Line 297: | Line 398: | ||
| 100419 | | 100419 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 4,310.00 Bbl | | style="text-align: right;" | 4,310.00 Bbl | ||
Line 303: | Line 404: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 3,460.00 Bbl | | style="text-align: right;" | 3,460.00 Bbl | ||
Line 309: | Line 410: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 26.66 Bbl | | style="text-align: right;" | 26.66 Bbl | ||
Line 315: | Line 416: | ||
| 34-121-23995 | | 34-121-23995 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 2,883.34 Bbl | | style="text-align: right;" | 2,883.34 Bbl | ||
Line 321: | Line 422: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 2,245.00 Bbl | | style="text-align: right;" | 2,245.00 Bbl | ||
Line 327: | Line 428: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 1,048.50 Bbl | | style="text-align: right;" | 1,048.50 Bbl | ||
Line 333: | Line 434: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 215.00 Bbl | | style="text-align: right;" | 215.00 Bbl | ||
Line 339: | Line 440: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 208.00 Bbl | | style="text-align: right;" | 208.00 Bbl | ||
Line 345: | Line 446: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 312.00 Bbl | | style="text-align: right;" | 312.00 Bbl | ||
Line 351: | Line 452: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 615.00 Bbl | | style="text-align: right;" | 615.00 Bbl | ||
Line 357: | Line 458: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 403.00 Bbl | | style="text-align: right;" | 403.00 Bbl | ||
Line 363: | Line 464: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 231.00 Bbl | | style="text-align: right;" | 231.00 Bbl | ||
Line 369: | Line 470: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M10 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 306.00 Bbl | | style="text-align: right;" | 306.00 Bbl | ||
Line 381: | Line 476: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 306.00 Bbl | | style="text-align: right;" | 306.00 Bbl | ||
Line 387: | Line 482: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016- | + | | 2016-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 307.00 Bbl | | style="text-align: right;" | 307.00 Bbl | ||
Line 393: | Line 488: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2016-S01 |
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 1,042.33 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2017-M01 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 202.00 Bbl | | style="text-align: right;" | 202.00 Bbl | ||
Line 399: | Line 500: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 335.00 Bbl | | style="text-align: right;" | 335.00 Bbl | ||
Line 405: | Line 506: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 102.00 Bbl | | style="text-align: right;" | 102.00 Bbl | ||
Line 411: | Line 512: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 101.00 Bbl | | style="text-align: right;" | 101.00 Bbl | ||
Line 417: | Line 518: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 207.00 Bbl | | style="text-align: right;" | 207.00 Bbl | ||
Line 423: | Line 524: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 104.00 Bbl | | style="text-align: right;" | 104.00 Bbl | ||
Line 429: | Line 530: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 306.00 Bbl | | style="text-align: right;" | 306.00 Bbl | ||
Line 435: | Line 536: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 205.00 Bbl | | style="text-align: right;" | 205.00 Bbl | ||
Line 441: | Line 542: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 102.00 Bbl | | style="text-align: right;" | 102.00 Bbl | ||
Line 447: | Line 548: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 203.00 Bbl | | style="text-align: right;" | 203.00 Bbl | ||
Line 453: | Line 554: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 102.00 Bbl | | style="text-align: right;" | 102.00 Bbl | ||
Line 459: | Line 560: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 408.00 Bbl | | style="text-align: right;" | 408.00 Bbl | ||
Line 465: | Line 566: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 204.00 Bbl | | style="text-align: right;" | 204.00 Bbl | ||
Line 471: | Line 572: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 102.00 Bbl | | style="text-align: right;" | 102.00 Bbl | ||
Line 477: | Line 578: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 204.00 Bbl | | style="text-align: right;" | 204.00 Bbl | ||
Line 483: | Line 584: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 101.00 Bbl | | style="text-align: right;" | 101.00 Bbl | ||
Line 489: | Line 590: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 102.00 Bbl | | style="text-align: right;" | 102.00 Bbl | ||
Line 495: | Line 596: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 408.00 Bbl | | style="text-align: right;" | 408.00 Bbl | ||
Line 501: | Line 602: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 100.00 Bbl | | style="text-align: right;" | 100.00 Bbl | ||
Line 507: | Line 608: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 302.00 Bbl | | style="text-align: right;" | 302.00 Bbl | ||
Line 513: | Line 614: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 410.00 Bbl | | style="text-align: right;" | 410.00 Bbl | ||
Line 519: | Line 620: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 412.00 Bbl | | style="text-align: right;" | 412.00 Bbl | ||
Line 525: | Line 626: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 307.00 Bbl | | style="text-align: right;" | 307.00 Bbl | ||
Line 531: | Line 632: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 307.00 Bbl | | style="text-align: right;" | 307.00 Bbl | ||
Line 537: | Line 638: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 309.00 Bbl | | style="text-align: right;" | 309.00 Bbl | ||
Line 543: | Line 644: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 205.00 Bbl | | style="text-align: right;" | 205.00 Bbl | ||
Line 549: | Line 650: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 307.00 Bbl | | style="text-align: right;" | 307.00 Bbl | ||
Line 555: | Line 656: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 102.00 Bbl | | style="text-align: right;" | 102.00 Bbl | ||
Line 561: | Line 662: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 307.00 Bbl | | style="text-align: right;" | 307.00 Bbl | ||
Line 567: | Line 668: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 205.00 Bbl | | style="text-align: right;" | 205.00 Bbl | ||
Line 573: | Line 674: | ||
| WMGR123SW010 | | WMGR123SW010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 104.00 Bbl | | style="text-align: right;" | 104.00 Bbl | ||
Line 579: | Line 680: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 307.00 Bbl | | style="text-align: right;" | 307.00 Bbl | ||
Line 585: | Line 686: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 307.00 Bbl | | style="text-align: right;" | 307.00 Bbl | ||
Line 591: | Line 692: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 207.00 Bbl | | style="text-align: right;" | 207.00 Bbl | ||
Line 597: | Line 698: | ||
| PAS2D561BSOM | | PAS2D561BSOM | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 311.00 Bbl | | style="text-align: right;" | 311.00 Bbl | ||
Line 622: | Line 723: | ||
| 1985943 | | 1985943 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2011-06-28 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 629: | Line 730: | ||
| 1986026 | | 1986026 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2011-06-09 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 636: | Line 737: | ||
| 2004283 | | 2004283 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2011-09-13 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 643: | Line 744: | ||
| 2006207 | | 2006207 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2011-09-28 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 650: | Line 751: | ||
| 2034177 | | 2034177 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2012-01-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 657: | Line 758: | ||
| 2069379 | | 2069379 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2012-05-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 664: | Line 765: | ||
| 2070076 | | 2070076 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2012-04-20 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 671: | Line 772: | ||
| 2082062 | | 2082062 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2012-07-03 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 678: | Line 779: | ||
| 2092742 | | 2092742 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2012-05-15 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 685: | Line 786: | ||
| 2092873 | | 2092873 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2012-06-01 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 692: | Line 793: | ||
| 2094651 | | 2094651 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2012-08-06 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 699: | Line 800: | ||
| 2141760 | | 2141760 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2013-02-19 |
| Incident- Response to Accident or Event | | Incident- Response to Accident or Event | ||
| In Compliance with Policy | | In Compliance with Policy | ||
Line 706: | Line 807: | ||
| 2145150 | | 2145150 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2013-02-25 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 713: | Line 814: | ||
| 2159322 | | 2159322 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2013-04-18 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 720: | Line 821: | ||
| 2169728 | | 2169728 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2013-05-22 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 727: | Line 828: | ||
| 2181817 | | 2181817 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2013-07-09 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 734: | Line 835: | ||
| 2196932 | | 2196932 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2013-08-20 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 741: | Line 842: | ||
| 2238794 | | 2238794 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2014-01-22 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 748: | Line 849: | ||
| 2297782 | | 2297782 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2014-08-20 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 755: | Line 856: | ||
| 2297815 | | 2297815 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2014-08-20 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 762: | Line 863: | ||
| 2323954 | | 2323954 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2014-11-24 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 769: | Line 870: | ||
| 2382918 | | 2382918 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2015-06-15 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 933: | Line 1,034: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-111-20291 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.033639,"lon":-79.184861,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Somerset | |
Municipality: Jefferson Township | |
Operator Name: LPR ENERGY LLC | |
Well Pad ID: 149131 | |
Farm/Lease Name: R MILLER UNIT 2H | |
License Status: Active | |
Spud Date: 2011-06-02 | |
Permit Date: 2010-01-07 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 40.033639 | |
Longitude: -79.184861 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-09-11 | 2012-09-11 | 7239.00 | 5,851,923.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | ASP 900 | Nalco | Friction Reducer | Ammonium sulfate | 7783-20-2 | 30.00 | ||
EC6673W | Nalco | Iron Control | Ethylene glycol | 107-21-1 | 30.00 | 0.00676000 | ||
Proppant (lbs) | Proppant | 9.32 | 10.36 | |||||
7.5 Hcl Acid | Used to open perfs | Hydrochloric acid | 7647-01-0 | 7.50 | 0.31 | |||
WG-36 GELLING AGENT | Halliburton Energy Services | Water Viscosifier | Guar gum | 9000-30-0 | 100.00 | 0.00187000 | ||
FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.03 | ||
EC6486A | Nalco | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00704000 | ||
Clean Volume (gals) | Carrier/Base Fluid | 90.68 | 100.00 | |||||
Biocide EC 6116A | Nalco | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00676000 | ||
Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | |||||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00113000 | |||||
GBW-30 BREAKER | Halliburton Energy Services | Gel Breaker | Hemicellulase enzyme | 9012-54-8 | 15.00 | 0.00011000 | ||
Carbohydrates | 95.00 | 0.00067000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 375,953.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 284,318.00 | 334 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 212,749.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 160,682.38 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | LPR ENERGY LLC | 134,297.00 | 354 | 0.00 | 0 | 0.00 | 0 |
2018 | LPR ENERGY LLC | 151,487.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | LPR ENERGY LLC | 31,409.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2011-S01 | Drill Cuttings (in Tons) | 462.41 Tons | LANDFILL | 100081 |
2011-S01 | Drilling Fluid Waste (in Barrels) | 130.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2012-S01 | Drilling Fluid Waste (in Barrels) | 1,195.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012-S01 | Drilling Fluid Waste (in Barrels) | 360.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-S02 | Drill Cuttings (in Tons) | 29.71 Tons | LANDFILL | 101421 |
2012-S02 | Drilling Fluid Waste (in Barrels) | 825.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012-S02 | Fracing Fluid Waste (in Barrels) | 8,438.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012-S02 | Fracturing Fluid Waste (in Tons) | 7.24 Tons | LANDFILL | 100419 |
2013-S01 | Fracing Fluid Waste (in Barrels) | 3,890.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S01 | Fracturing Fluid Waste (in Tons) | 1.50 Tons | LANDFILL | 100419 |
2013-S01 | Produced Fluid (in Barrels) | 5,226.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Drill Cuttings (in Tons) | 270.42 Tons | LANDFILL | 100172 |
2013-S02 | Fracturing Fluid Waste (in Tons) | 10.51 Tons | LANDFILL | 100419 |
2013-S02 | Produced Fluid (in Barrels) | 4,310.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Produced Fluid (in Barrels) | 3,460.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Produced Fluid (in Barrels) | 26.66 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2014-S02 | Produced Fluid (in Barrels) | 2,883.34 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Produced Fluid (in Barrels) | 2,245.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 1,048.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M04 | Produced Fluid (in Barrels) RWC 802 | 215.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M05 | Produced Fluid (in Barrels) RWC 802 | 208.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M06 | Produced Fluid (in Barrels) RWC 802 | 312.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M07 | Produced Fluid (in Barrels) RWC 802 | 615.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M08 | Produced Fluid (in Barrels) RWC 802 | 403.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M09 | Produced Fluid (in Barrels) RWC 802 | 231.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2016-M10 | Produced Fluid (in Barrels) RWC 802 | 306.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M11 | Produced Fluid (in Barrels) RWC 802 | 306.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-M12 | Produced Fluid (in Barrels) RWC 802 | 307.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 1,042.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 202.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 335.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 102.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 101.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 207.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 104.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 306.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 205.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 102.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 203.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 102.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 408.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 204.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 102.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 204.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 101.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 102.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 408.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 302.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 410.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 412.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 307.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 307.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 309.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 205.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 307.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 102.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 307.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 205.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 104.00 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 307.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 307.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 207.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 311.00 Bbl | INJECTION DISPOSAL WELL | PAS2D561BSOM |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1985943 | Primary Facility | 2011-06-28 | Drilling/Alteration | No Violations Noted | At the time of inspection, drilling equipment was removed from site. No E&S or IW issues. Well head was completed with well head manifold. No pressure on the gauge at the manifold. |
1986026 | Primary Facility | 2011-06-09 | Drilling/Alteration | No Violations Noted | Chief contracted UDI 5 to install gas well. Chief contact person was Dewayne Pauley. Conductor pipe (20¿) installed to 60 ft and grouted to surface. Second stringer was 13 3/8¿ installed to 462 ft with 330 sks of gas blocks with 11 bbl return. Current depth was 1781. At the time of inspection, no E&S issues or IW issues at the site. Chief proposing to install 9 5/8¿ pipe to 1811 ft. |
2004283 | Primary Facility | 2011-09-13 | Routine/Complete Inspection | No Violations Noted | During this inspection, Chevron Regulatory Compliance Personnel and WQS Marc Maestra present. Well ID sign, ES plan w/ PPC plan, and ESCGP-1 onsite. Well drilled not yet in production. Access road/entrance and well pad adequately rocked. BMPs installed and functioning according to ES Control Plan and appear properly maintained. No accelerated erosion or sedimentation issues noted during inspection. Previously disturbed areas have been seeded/mulched with growth observed. R Miller 6H recently spudded and drilled. No pits or tanks present on site. No violations noted during this inspection. |
2006207 | Primary Facility | 2011-09-28 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, drilling equipment was removed from site. No E&S or IW issues. Well head was completed with well head manifold. No pressure reading on the gauge located at the manifold. Annulus valve was closed. |
2034177 | Primary Facility | 2012-01-10 | Routine/Complete Inspection | No Violations Noted | During this inspection; well sign, ES plan, ESCGP-1, and PPC plan onsite. Well tag present, although recommend operator update well tags to include current operator information. |
2069379 | Primary Facility | 2012-05-10 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection, site Id sign, Es plan, ESCGP-1, and PPC plan onsite. Site gated and monitored by 24hr security. Multi well pad. Said well previously drilled. Crown Rig # 8 actively drilling 6H. Charles, DSM onsite during this inspection. Secondary containment in place beneath rig and onsite tanks. No pits installed by Chevron for drilling operations. Tanks and secondary containment look structurally sound. Appears bmp's are installed and functioning according to plan. No accelerated erosion or sedimentation issues noted with site or access road. Access road adequately rocked.Noted a "small" leak coming from Residual waste box on site, notified DSM whom stated the problem would be addressed immediately. Absorbent pads were placed in location of leak. Department also noted to DSM of a possible safety concern near back side of rig, where it appears shale was placed over top electric lines and drilling equipment (see picture). DSM stated that matter would be addressed immediately no violations noted. |
2070076 | Primary Facility | 2012-04-20 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Chevron had contracted Highland #2. Conductor pipe was set at 60 ft. (20’’pipe) and was grouted in place. 13 3/8” pipe was set at 457’ (surface pipe) and the 9 5/8” pipe was set at 1807 feet. Chevron current depth was 5,663 feet. Chevron was planning to TD at 7500 feet and set the kick off point. DEP personnel performed a site walk and did not find any issues. |
2082062 | Primary Facility | 2012-07-03 | Routine/Complete Inspection | No Violations Noted | |
2092742 | Primary Facility | 2012-05-15 | Drilling/Alteration | No Violations Noted | Well 2H was completed and Chevron was setting up on 6H. |
2092873 | Primary Facility | 2012-06-01 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Chevron had contracted Highland #2. Conductor pipe was set at 60 ft. (20’’pipe) and was grouted in place. 13 3/8” pipe was set at 457’ (surface pipe) and the 9 5/8” pipe was set at 1807 feet. Chevron current depth was 14,255 feet. Chevron set the kick off point at 7829 ft. DEP personnel performed a site walk and did not find any issues. |
2094651 | Primary Facility | 2012-08-06 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no site activity and no E&S issues were present. |
2141760 | Primary Facility | 2013-02-19 | Incident- Response to Accident or Event | In Compliance with Policy | Admin Inspt. Spoke to Chevron representative B.A. Lambie via phone on 2/19/13. According to Mr. Lambie, on 2/18/13 as truck was loading production brine, truck tank began leaking due to failed tank seam. Resulted in approximately 10 gallons of brine released to ground, impacting an approximate area of 15 square feet. Impacted materials immediately excavated into drum. Samples taken, will dispose of in landfill. It appears Operator handled situation according to policy and a follow-up inspection will be conducted in future to ensure full compliance. |
2145150 | Primary Facility | 2013-02-25 | Routine/Complete Inspection | No Violations Noted | Regulatory inactive status. Multi-well pad. |
2159322 | Primary Facility | 2013-04-18 | Routine/Complete Inspection | No Violations Noted | Routine inspection. 5 unmarked drums found on site. |
2169728 | Primary Facility | 2013-05-22 | Routine/Complete Inspection | No Violations Noted | |
2181817 | Primary Facility | 2013-07-09 | Routine/Complete Inspection | No Violations Noted | Inspectd site. No issues noted other than there are 5 un marked drums on site. These drums were noted on a 5/22/13 inspection. |
2196932 | Primary Facility | 2013-08-20 | Routine/Complete Inspection | No Violations Noted | Inspected the site on 8/20/13. There was not any activity on the restored well pad. The road going into the site was well graveled. The welll pad was well graveled. The Well pad signs were properly marked. This pad has three producing Marcelus gas wells. The three wells were properly marked.The drums observed in the past inspection were removed from the pad.There were two dumpsters on the well pad that contained Demo waste. No staining on the well pad was observed. The fresh water impoundment is now fenced in. No E&S issues were observed. During the inspection no issues were observed that need to be addresed |
2238794 | Primary Facility | 2014-01-22 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S issues were present. Well was in production. |
2297782 | Primary Facility | 2014-08-20 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S issues were present. Well was in production. |
2297815 | Primary Facility | 2014-08-20 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S issues were present. Well was in production. |
2323954 | Primary Facility | 2014-11-24 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S issues were present. Well was in production. |
2382918 | Primary Facility | 2015-06-15 | Routine/Complete Inspection | No Violations Noted | no issues. system running |
2443387 | Primary Facility | 2016-01-12 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2486198 | Primary Facility | 2016-05-19 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2493461 | Primary Facility | 2016-06-13 | Routine/Complete Inspection | No Violations Noted | Multi-well Marcellus pad.
At time of inspection site ID sign on site. ERP, PPC plan, ESCGP1 and well permit on site. Site surrounded by security fence. Gate locked. It appears well tag is present. Brine tank located in secondary containment appears structurally sound. Access road and pad rocked. No E&S issues observed on access road or on well pad. |
2532144 | Primary Facility | 2016-10-05 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2580970 | Primary Facility | 2017-04-10 | Routine/Complete Inspection | No Violations Noted | Well appears to be in production. Well pad surrounded by security fence. |
2594458 | Primary Facility | 2017-04-25 | Routine/Complete Inspection | No Violations Noted | system running no issues |
2605005 | Primary Facility | 2017-06-15 | Routine/Complete Inspection | No Violations Noted | Wells active 1H, 6H, 2H in production. no issues |
2624208 | Primary Facility | 2017-08-02 | Routine/Complete Inspection | No Violations Noted | system running. no issues. no loud sounds coming from Miller pad and no heavy equipment running. |
2626020 | Primary Facility | 2017-08-16 | Routine/Complete Inspection | No Violations Noted | 1H, 2H and 6H wells are in production. No issues at the site. Wells 3H, 4H, and 5H were not drilled. |
2672260 | Primary Facility | 2017-12-18 | Routine/Partial Inspection | In Compliance with Policy | Routine partial inspection due to snow cover. At time of inspection it appears well is in production. |
2673674 | Primary Facility | 2017-12-21 | Routine/Complete Inspection | No Violations Noted | System running. No issues. .well tag present |
2683418 | Primary Facility | 2018-01-18 | Routine/Complete Inspection | No Violations Noted | System running no issues. Well tag present. Emergency contact sign present. |
2700591 | Primary Facility | 2018-03-05 | Routine/Complete Inspection | No Violations Noted | Well tag present and emergency contact information present. No issues at the site |
2710352 | Primary Facility | 2018-03-26 | Routine/Complete Inspection | No Violations Noted | Well tag and emergency contact number present at the site. No issues at the site |
2719668 | Primary Facility | 2018-04-18 | Routine/Complete Inspection | No Violations Noted | Well appears equipped for production. Well pad surrounded by security fence. Well tender on site during inspection. |
2728427 | Primary Facility | 2018-05-09 | Routine/Complete Inspection | No Violations Noted | Well was in production. Well tag and emergency contact present. No issues at the site |
2827771 | Primary Facility | 2019-01-16 | Routine/Complete Inspection | No Violations Noted | Wells are in production. No issues at the site |
2853753 | Primary Facility | 2019-03-14 | Routine/Complete Inspection | No Violations Noted | System running. Well in production. Production reports submitted to state. |
For data sources see[7]