X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-081-21428"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-081-21428
 
| Well ID: 37-081-21428
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.59018, -76.822702 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.590181, -76.822703 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Lycoming County, Pennsylvania|Lycoming]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[McNett Township, Lycoming County, Pennsylvania|McNett Township]]
+
| State: Pennsylvania
 +
|-
 +
| County: [[Lycoming_County,_Pennsylvania|Lycoming]]
 +
|-
 +
| Municipality: [[McNett Township,_Lycoming_County,_Pennsylvania|McNett Township]]
 
|-
 
|-
 
| Operator Name: [[CHIEF OIL & GAS LLC]]
 
| Operator Name: [[CHIEF OIL & GAS LLC]]
 
|-
 
|-
| Well Pad ID: [[145293|145293]]
+
| Well Pad ID: [[145293]]
 
|-
 
|-
 
| Farm/Lease Name: COTTON HANLON UNIT 1H
 
| Farm/Lease Name: COTTON HANLON UNIT 1H
 
|-
 
|-
| First Permit Date: 2014-03-06
+
| License Status: Active
|-
 
| Last Permit Date: 2014-03-06
 
 
|-
 
|-
| Spud Date: 2014-04-17
+
| Spud Date: 04/17/2014
 
|-
 
|-
| Unconventional: Yes
+
| Permit Date: 3/6/2014
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Well Status: ACTIVE
+
| Configuration: Horizontal Well
 
|-
 
|-
| Violations: 0
+
| Latitude: 41.590181
|-
 
| Latitude: 41.59018
 
|-
 
| Longitude: -76.822702
 
 
|-
 
|-
 +
| Longitude: -76.822703
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
|-
+
!scope="col" | Water Production Days
| 2014-1
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2014-2
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2014
 +
| [[CHIEF OIL & GAS LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2015-02
+
| 2015
| style="text-align:right;" | 0.0
+
| [[CHIEF OIL & GAS LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 189,604.07
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 17
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2016
 +
| [[CHIEF OIL & GAS LLC]]
 +
| style="text-align: right;" | 3,111,620.54
 +
| style="text-align: right;" | 366
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2015-01
+
| 2017
| style="text-align:right;" | 0.0
+
| [[CHIEF OIL & GAS LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 1,363,177.82
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 363
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2018
 +
| [[CHIEF OIL & GAS LLC]]
 +
| style="text-align: right;" | 1,014,712.39
 +
| style="text-align: right;" | 342
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2015-03
+
| 2019
| style="text-align:right;" | 0.0
+
| [[CHIEF OIL & GAS LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 249,640.36
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 90
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =Oil and Gas Production Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Waste Type
!scope="col" | QUANTITY
+
!scope="col" | Quantity
!scope="col" | UNITS
+
!scope="col" | Disposal Method
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2014-1
+
| 2014-S01
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 961.28
+
| style="text-align: right;" | 961.28 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 301358
 
| 301358
| PHOENIX RESOURCES LANDFILL
 
| WELLSBORO
 
| PA
 
|-
 
 
|-
 
|-
| 2014-1
+
| 2014-S01
| DRILLING FLUID WASTE
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 220.0
+
| style="text-align: right;" | 220.00 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR119
 
| WMGR119
| EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
|-
+
| 2014-S01
| 2014-1
+
| Drilling Fluid Waste (in Barrels)
| DRILLING FLUID WASTE
+
| style="text-align: right;" | 1,980.00 Bbl
| style="text-align:right;" | 1.0
 
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR0123
+
| WMGR123
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
 
|-
 
|-
|-
+
| 2014-S02
| 2014-2
+
| Drill Cuttings (in Tons)
| DRILL CUTTINGS
+
| style="text-align: right;" | 30.66 Tons
| style="text-align:right;" | 30.66
 
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 301358
 
| 301358
| PHOENIX RESOURCES LANDFILL
 
| WELLSBORO
 
| PA
 
 
|-
 
|-
 +
| 2014-S02
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 480.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123
 
|-
 
|-
| 2014-2
+
| 2014-S02
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 480.0
+
| style="text-align: right;" | 13,654.00 Bbl
| Bbl
+
| REUSE OTHER THAN ROAD SPREADING
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
|  
| WMGR0123
 
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
 
|-
 
|-
 +
| 2015-S02
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 1,042.59 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2014-2
+
| 2016-S01
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 13.0
+
| style="text-align: right;" | 21,115.36 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2016-S02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13,777.47 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2017-M01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 508.52 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 494.32 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 820.01 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 242.56 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 175.52 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 138.05 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 113.98 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 131.10 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 368.24 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 300.40 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 297.54 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-M12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 564.06 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 272.21 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 924.37 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 383.06 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 177.23 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 181.20 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 272.65 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 236.73 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 151.14 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 136.11 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,083.85 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 352.37 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-M12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 338.74 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2019-M01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 413.33 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2019-M02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 265.53 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2019-M03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 334.85 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-26 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
| 2306282
+
| 2269142
| 2014-09-18
+
| Primary Facility
 +
| 05/08/2014
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
| Routine Inspection; 9/18/2014. At the time of the inspection Halliburton was onsite conducting active completions (perf. and frac.) on both wells onsite. They were under pressure on stage 28 of 29 on the Weiler 1H (081-21429). The Cotton Hanlon 1H (081-21428) was on stage 29 of 32. Water was being pumped from a temporary tank at the beginning of the access road up the mountain to the well pad. Overall
 
 
|  
 
|  
 +
|-
 +
| 2271940
 +
| Primary Facility
 +
| 05/13/2014
 +
| Drilling/Alteration
 +
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2275786
 +
| Primary Facility
 +
| 06/03/2014
 +
| Drilling/Alteration
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
 +
| 2306282
 +
| Primary Facility
 +
| 09/18/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Routine Inspection; 9/18/2014.
 
|-
 
|-
 
| 2307011
 
| 2307011
| 2014-09-25
+
| Primary Facility
 +
| 09/25/2014
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|  
+
|-
|  
+
| 2566533
|  
+
| Primary Facility
 +
| 2017-02-24
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Routine Complete Inspection 2/24/2017.
 +
I entered the site at 12:05. At the time of the inspection, the Cotton Hanlon 1H (081-21428) and the Weiler 1H (081-21429) wells were in production.  The fresh water tank pad at the access road remains installed but the tank has been removed.  The PCSM (Post Construction Stormwater Management) is permitted for this site has not been implemented. 
 +
The roadside ditch leading to the first stilling basin (Approximately 575’ south of Barnes Hill Road) has erosion which is causing water to flow around the basin.  The well pad was constructed as designed but the permitted plan has an impoundment located south of the well pad.  Stormwater is handled by an infiltration berm which has not yet been implemented.  The latest restoration schedule, submitted on 11/16/016, indicates Chief is planning to restore the site on 6/10/2017.  Currently, the site has not been restored as per 3216(c) of the Oil and Gas Act as amended by Act 13.  I recommend implementing the PCSM designed for th
 +
|-
 +
| 2793512
 +
| Primary Facility
 +
| 2018-10-24
 +
| Site Restoration
 +
| No Violations Noted
 +
| Two wells staged for production phase. Two each water separators. No leaks detected from production equipment. No violations noted. Property is owned by Cotton Hanlon Incorporated c/o Forestry Dept.
 +
 
 +
The eSubmission Post Drilling Site Restoration Report was submitted to the DEP on 10/23/2018. Based on this inspection report the Post Drilling Restoration report was accepted on 5/24/2018.
 +
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 09/07/2014
 +
| 09/19/2014
 +
| style="text-align: right;" | 8853
 +
| style="text-align: right;" | 14,274,200.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="6"| 1
 +
| rowspan="1"| Water
 +
| rowspan="1"| Provided by Customer
 +
| rowspan="1"| Base Fluid
 +
| Fresh Water
 +
| 0000-00-0
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 99.9
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| MCS-2510T
 +
| rowspan="1"| MULTI-CHEM
 +
| rowspan="1"| Scale Inhibitor
 +
| ETHYLENE GLYCOL
 +
| 107-21-1
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| MCB-8614
 +
| rowspan="2"| MULTI-CHEM
 +
| rowspan="2"| BIOCIDE
 +
| GLUTARALDEHYDE
 +
| 111-30-8
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" | 0
 +
|-
 +
| ALKYL (C12-16) DIMETHYLBENZXYLAMMONIUM CHLORIDE
 +
| 68424-85-1
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.003
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| FR-66
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Friction Reducer
 +
| Hydrotreated Light Petroleum Distillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Hydrochloric Acid 10-30%
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Acid
 +
| Hydrochloric Acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.04
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
==References==
== References ==
+
<references/>
{{reflist}}
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 21:18, 17 July 2019

Well Details

Well ID: 37-081-21428
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: McNett Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 145293
Farm/Lease Name: COTTON HANLON UNIT 1H
License Status: Active
Spud Date: 04/17/2014
Permit Date: 3/6/2014
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.590181
Longitude: -76.822703

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 189,604.07 17 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 3,111,620.54 366 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 1,363,177.82 363 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 1,014,712.39 342 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 249,640.36 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2014-S01 Drill Cuttings (in Tons) 961.28 Tons LANDFILL 301358
2014-S01 Drilling Fluid Waste (in Barrels) 220.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014-S01 Drilling Fluid Waste (in Barrels) 1,980.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-S02 Drill Cuttings (in Tons) 30.66 Tons LANDFILL 301358
2014-S02 Fracing Fluid Waste (in Barrels) 480.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-S02 Fracing Fluid Waste (in Barrels) 13,654.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 1,042.59 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 21,115.36 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Produced Fluid (in Barrels) RWC 802 13,777.47 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 508.52 Bbl REUSE (AT WELL PAD)
2017-M02 Produced Fluid (in Barrels) RWC 802 494.32 Bbl REUSE (AT WELL PAD)
2017-M03 Produced Fluid (in Barrels) RWC 802 820.01 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 242.56 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 175.52 Bbl REUSE (AT WELL PAD)
2017-M06 Produced Fluid (in Barrels) RWC 802 138.05 Bbl REUSE (AT WELL PAD)
2017-M07 Produced Fluid (in Barrels) RWC 802 113.98 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 131.10 Bbl REUSE (AT WELL PAD)
2017-M09 Produced Fluid (in Barrels) RWC 802 368.24 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 300.40 Bbl REUSE (AT WELL PAD)
2017-M11 Produced Fluid (in Barrels) RWC 802 297.54 Bbl REUSE (AT WELL PAD)
2017-M12 Produced Fluid (in Barrels) RWC 802 564.06 Bbl REUSE (AT WELL PAD)
2018-M01 Produced Fluid (in Barrels) RWC 802 272.21 Bbl REUSE (AT WELL PAD)
2018-M02 Produced Fluid (in Barrels) RWC 802 924.37 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 383.06 Bbl REUSE (AT WELL PAD)
2018-M04 Produced Fluid (in Barrels) RWC 802 177.23 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 181.20 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 272.65 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 236.73 Bbl REUSE (AT WELL PAD)
2018-M08 Produced Fluid (in Barrels) RWC 802 151.14 Bbl REUSE (AT WELL PAD)
2018-M09 Produced Fluid (in Barrels) RWC 802 136.11 Bbl REUSE (AT WELL PAD)
2018-M10 Produced Fluid (in Barrels) RWC 802 1,083.85 Bbl REUSE (AT WELL PAD)
2018-M11 Produced Fluid (in Barrels) RWC 802 352.37 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 338.74 Bbl REUSE (AT WELL PAD)
2019-M01 Produced Fluid (in Barrels) RWC 802 413.33 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 265.53 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 334.85 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2269142 Primary Facility 05/08/2014 Routine/Complete Inspection No Violations Noted
2271940 Primary Facility 05/13/2014 Drilling/Alteration No Violations Noted
2275786 Primary Facility 06/03/2014 Drilling/Alteration No Violations Noted
2306282 Primary Facility 09/18/2014 Routine/Complete Inspection No Violations Noted Routine Inspection; 9/18/2014.
2307011 Primary Facility 09/25/2014 Routine/Complete Inspection No Violations Noted
2566533 Primary Facility 2017-02-24 Routine/Complete Inspection No Violations Noted Routine Complete Inspection 2/24/2017.

I entered the site at 12:05. At the time of the inspection, the Cotton Hanlon 1H (081-21428) and the Weiler 1H (081-21429) wells were in production. The fresh water tank pad at the access road remains installed but the tank has been removed. The PCSM (Post Construction Stormwater Management) is permitted for this site has not been implemented. The roadside ditch leading to the first stilling basin (Approximately 575’ south of Barnes Hill Road) has erosion which is causing water to flow around the basin. The well pad was constructed as designed but the permitted plan has an impoundment located south of the well pad. Stormwater is handled by an infiltration berm which has not yet been implemented. The latest restoration schedule, submitted on 11/16/016, indicates Chief is planning to restore the site on 6/10/2017. Currently, the site has not been restored as per 3216(c) of the Oil and Gas Act as amended by Act 13. I recommend implementing the PCSM designed for th

2793512 Primary Facility 2018-10-24 Site Restoration No Violations Noted Two wells staged for production phase. Two each water separators. No leaks detected from production equipment. No violations noted. Property is owned by Cotton Hanlon Incorporated c/o Forestry Dept.

The eSubmission Post Drilling Site Restoration Report was submitted to the DEP on 10/23/2018. Based on this inspection report the Post Drilling Restoration report was accepted on 5/24/2018.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 09/07/2014 09/19/2014 8853 14,274,200.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Provided by Customer Base Fluid Fresh Water 0000-00-0 100 99.9 0
MCS-2510T MULTI-CHEM Scale Inhibitor ETHYLENE GLYCOL 107-21-1 60 0.01 0
MCB-8614 MULTI-CHEM BIOCIDE GLUTARALDEHYDE 111-30-8 30 0.02 0
ALKYL (C12-16) DIMETHYLBENZXYLAMMONIUM CHLORIDE 68424-85-1 5 0.003 0
FR-66 Halliburton Friction Reducer Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.02 0
Hydrochloric Acid 10-30% Halliburton Acid Hydrochloric Acid 7647-01-0 30 0.04 0

For data sources see[7]

References