If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
| Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-081-21081 | | Well ID: 37-081-21081 | ||
| − | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="14" | {{#display_map: 41.312442, -76.889214 | width=100% | height=100% }} |
|- | |- | ||
| − | | | + | | Country: United States |
|- | |- | ||
| − | | | + | | State: Pennsylvania |
|- | |- | ||
| − | | | + | | County: [[Lycoming_County,_Pennsylvania|Lycoming]] |
|- | |- | ||
| − | | | + | | Municipality: [[Upper Fairfield Township,_Lycoming_County,_Pennsylvania|Upper Fairfield Township]] |
|- | |- | ||
| − | | | + | | Operator Name: [[INFLECTION ENERGY (PA) LLC]] |
|- | |- | ||
| − | | | + | | Well Pad ID: [[145466]] |
|- | |- | ||
| − | | | + | | Farm/Lease Name: NATURE BOY EAST YODER 2V |
| − | |||
| − | |||
|- | |- | ||
| − | | | + | | License Status: Active |
|- | |- | ||
| − | | | + | | Spud Date: 06/11/2013 |
|- | |- | ||
| − | | | + | | Permit Date: 12/11/2012 |
|- | |- | ||
| − | | | + | | Unconventional Well: Y |
|- | |- | ||
| − | | | + | | Configuration: Horizontal Well |
|- | |- | ||
| − | | | + | | Latitude: 41.312442 |
|- | |- | ||
| + | | Longitude: -76.889214 | ||
|} | |} | ||
| + | For data sources see<ref>{{cite web | ||
| + | | title = Permits Issued Detail Report | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-05-20 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
| + | | title = Spud Data Report | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-04-30 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
| + | | title = Oil and Gas Well Pad Report | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-05-20 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-21 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
| − | !scope="col" | | + | !scope="col" | Period |
| − | !scope="col" | | + | !scope="col" | Operator Name |
| − | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
| − | !scope="col" | | + | !scope="col" | Gas Production Days |
| − | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
| − | !scope="col" | | + | !scope="col" | Oil Production Days |
| − | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
| − | + | !scope="col" | Water Production Days | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | | | + | | 2013 |
| − | | style="text-align:right;" | | + | | [[INFLECTION ENERGY LLC]] |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| + | | 2014 | ||
| + | | [[INFLECTION ENERGY LLC]] | ||
| + | | style="text-align: right;" | 1,819,320.00 | ||
| + | | style="text-align: right;" | 331 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| − | | | + | | 2015 |
| − | | style="text-align:right;" | | + | | [[INFLECTION ENERGY (PA) LLC]] |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 1,213,030.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 357 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| + | | 2016 | ||
| + | | [[INFLECTION ENERGY (PA) LLC]] | ||
| + | | style="text-align: right;" | 1,009,774.09 | ||
| + | | style="text-align: right;" | 360 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| − | | | + | | 2017 |
| − | | style="text-align:right;" | | + | | [[INFLECTION ENERGY (PA) LLC]] |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 1,051,838.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 364 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| + | | 2018 | ||
| + | | [[INFLECTION ENERGY (PA) LLC]] | ||
| + | | style="text-align: right;" | 828,640.00 | ||
| + | | style="text-align: right;" | 353 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| − | | 2019 | + | | 2019 |
| − | | style="text-align:right;" | | + | | [[INFLECTION ENERGY (PA) LLC]] |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 190,932.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 90 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
| − | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
| − | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
| − | + | | date = 2019-03-31 | |
| − | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
| − | + | | accessdate = 2019-05-21 }}</ref> | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| − | | accessdate = | ||
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
| − | !scope="col" | | + | !scope="col" | Period |
| − | !scope="col" | | + | !scope="col" | Waste Type |
| − | !scope="col" | | + | !scope="col" | Quantity |
| − | !scope="col" | | + | !scope="col" | Disposal Method |
| − | !scope="col" | | + | !scope="col" | Waste Facility ID |
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | | | + | | 2013-S02 |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| − | | style="text-align:right;" | 176.87 | + | | style="text-align: right;" | 176.87 Tons |
| − | |||
| LANDFILL | | LANDFILL | ||
| 301626 | | 301626 | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| + | | 2013-S02 | ||
| + | | Drilling Fluid Waste (in Barrels) | ||
| + | | style="text-align: right;" | 864.00 Bbl | ||
| + | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| + | | WMGR123SW018 | ||
|- | |- | ||
| − | | | + | | 2013-S02 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| − | | style="text-align:right;" | 590.13 | + | | style="text-align: right;" | 590.13 Tons |
| − | |||
| LANDFILL | | LANDFILL | ||
| 301626 | | 301626 | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| + | | 2014-S01 | ||
| + | | Drill Cuttings (in Tons) | ||
| + | | style="text-align: right;" | 176.87 Tons | ||
| + | | LANDFILL | ||
| + | | 301626 | ||
|- | |- | ||
| − | | 2014- | + | | 2014-S01 |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| − | | style="text-align:right;" | 864. | + | | style="text-align: right;" | 864.00 Bbl |
| − | |||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR123SW018 | | WMGR123SW018 | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | |- | + | | 2014-S01 |
| − | |||
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| − | | style="text-align:right;" | 590.13 | + | | style="text-align: right;" | 590.13 Tons |
| − | |||
| LANDFILL | | LANDFILL | ||
| 301626 | | 301626 | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| + | | 2014-S02 | ||
| + | | Produced Fluid (in Barrels) | ||
| + | | style="text-align: right;" | 2,816.66 Bbl | ||
| + | | REUSE OTHER THAN ROAD SPREADING | ||
| + | | | ||
|- | |- | ||
| − | + | | 2015-M02 | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | | 2015- | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 381.30 Bbl |
| − | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| − | |||
| − | |||
| − | |||
| | | | ||
|- | |- | ||
| − | + | | 2015-S02 | |
| − | | 2015- | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 894.60 Bbl |
| − | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | | | + | | 2016-S01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 488.00 Bbl |
| − | + | | REUSE OTHER THAN ROAD SPREADING | |
| − | | REUSE | ||
| | | | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| + | | 2016-S01 | ||
| + | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
| + | | style="text-align: right;" | 4.83 Tons | ||
| + | | LANDFILL | ||
| + | | 301626 | ||
|- | |- | ||
| − | | | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 40.00 Bbl |
| − | + | | RESIDUAL WASTE PROCESSING FACILITY | |
| − | | | + | | WMGR123 |
| − | |||
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | | | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 582.00 Bbl |
| − | + | | REUSE OTHER THAN ROAD SPREADING | |
| − | | REUSE | ||
| − | |||
| − | |||
| | | | ||
| − | |||
|- | |- | ||
| − | + | | 2017-M01 | |
| − | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 157.70 Bbl |
| − | + | | RESIDUAL WASTE PROCESSING FACILITY | |
| − | | | + | | WMGR123 |
| − | |||
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | | 2017- | + | | 2017-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 61.23 Bbl |
| − | + | | RESIDUAL WASTE PROCESSING FACILITY | |
| − | | | + | | WMGR119 |
| − | |||
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | | 2017- | + | | 2017-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 37.71 Bbl |
| − | + | | RESIDUAL WASTE PROCESSING FACILITY | |
| − | | | + | | WMGR123NW005 |
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | + | | 2017-M03 | |
| − | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 62.85 Bbl |
| − | + | | RESIDUAL WASTE PROCESSING FACILITY | |
| − | | | + | | WMGR119 |
| − | |||
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 53.62 Bbl |
| − | + | | RESIDUAL WASTE PROCESSING FACILITY | |
| − | | | + | | WMGR123 |
| − | |||
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 83.71 Bbl |
| − | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| − | | | + | | WMGR123 |
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 35.31 Bbl |
| − | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| − | | | + | | WMGR123NC010 |
| − | |||
| − | |||
| − | |||
|- | |- | ||
| + | | 2017-M05 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 106.50 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
|- | |- | ||
| − | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | 48.57 | + | | style="text-align: right;" | 48.57 Bbl |
| − | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR119 | | WMGR119 | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 18.60 Bbl |
| − | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123NW005 | | WMGR123NW005 | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 15.40 Bbl |
| − | + | | REUSE (AT WELL PAD) | |
| − | | | + | | |
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | + | | 2017-M07 | |
| − | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 54.94 Bbl |
| − | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123 | | WMGR123 | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| + | | 2017-M07 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 30.57 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
|- | |- | ||
| − | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 94.28 Bbl |
| − | + | | REUSE (AT WELL PAD) | |
| − | | | + | | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 38.00 Bbl |
| − | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123 | | WMGR123 | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | + | | 2017-M10 | |
| − | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 114.00 Bbl |
| − | + | | REUSE (AT WELL PAD) | |
| − | | | + | | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | | 2017- | + | | 2017-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 97.00 Bbl |
| − | + | | REUSE (AT WELL PAD) | |
| − | | | + | | |
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | + | | 2017-M12 | |
| − | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 77.84 Bbl |
| − | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123NC010 | | WMGR123NC010 | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | |- | + | | 2018-M01 |
| − | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 37.71 Bbl |
| − | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| − | | | + | | WMGR123 |
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | + | | 2018-M02 | |
| − | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 80.00 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | + | | 2018-M03 | |
| − | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 80.00 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | | | + | |- |
| + | | 2018-M05 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 45.71 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | |||
| − | |||
|- | |- | ||
| − | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 139.71 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | | | + | |- |
| + | | 2018-M06 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 17.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | |||
|- | |- | ||
| − | + | | 2018-M06 | |
| − | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 51.00 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | | | + | |- |
| + | | 2018-M07 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 14.28 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | |||
|- | |- | ||
| − | + | | 2018-M07 | |
| − | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 74.29 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | | | + | |- |
| + | | 2018-M08 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 44.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | |||
|- | |- | ||
| − | + | | 2018-M08 | |
| − | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 62.00 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | | | + | |- |
| + | | 2018-M09 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 25.71 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | |||
| − | |||
|- | |- | ||
| − | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | 51. | + | | style="text-align: right;" | 51.43 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 82.00 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | | | + | |- |
| + | | 2018-M11 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 11.43 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | |||
|- | |- | ||
| − | + | | 2018-M11 | |
| − | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 34.29 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | | | + | |- |
| + | | 2018-M12 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 37.71 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | |||
| − | |||
|- | |- | ||
| − | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 62.85 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | |- | + | | 2019-M01 |
| − | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 45.70 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| + | | 2019-M02 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 71.42 Bbl | ||
| + | | RESIDUAL WASTE PROCESSING FACILITY | ||
| + | | WMGR123NW011 | ||
| + | |- | ||
| + | | 2019-M03 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 18.00 Bbl | ||
| + | | RESIDUAL WASTE PROCESSING FACILITY | ||
| + | | WMGR123NW011 | ||
|- | |- | ||
| − | | | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 79.00 Bbl |
| − | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
| − | | | + | |- |
| + | |} | ||
| + | For data sources see<ref>{{cite web | ||
| + | | title =Oil and Gas Waste Reports | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-03-31 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-21 }}</ref> | ||
| + | == Inspection Data == | ||
| + | ==== Inspections Performed ==== | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Inspection ID | ||
| + | !scope="col" | Inspection Category | ||
| + | !scope="col" | Inspection Date | ||
| + | !scope="col" | Inspection Type | ||
| + | !scope="col" | Inspection Result | ||
| + | !scope="col" | Inspection Comments | ||
| + | |- | ||
| + | | 2130018 | ||
| + | | Primary Facility | ||
| + | | 01/10/2013 | ||
| + | | Routine/Complete Inspection | ||
| + | | No Violations Noted | ||
| | | | ||
| − | |||
|- | |- | ||
| + | | 2184074 | ||
| + | | Primary Facility | ||
| + | | 07/08/2013 | ||
| + | | Routine/Complete Inspection | ||
| + | | No Violations Noted | ||
| + | | Brine/produced water spill. Sumps dug in the fill slope and are recovering spilled material. Violations cited ot the 081-21080 well | ||
|- | |- | ||
| − | | | + | | 2230427 |
| − | | | + | | Primary Facility |
| − | | | + | | 12/18/2013 |
| − | | | + | | Routine/Complete Inspection |
| − | | | + | | No Violations Noted |
| + | | | ||
| + | |- | ||
| + | | 2266779 | ||
| + | | Primary Facility | ||
| + | | 04/11/2014 | ||
| + | | Drilling/Alteration | ||
| + | | No Violations Noted | ||
| | | | ||
| − | | | + | |- |
| + | | 2444783 | ||
| + | | Primary Facility | ||
| + | | 2016-01-26 | ||
| + | | Routine/Complete Inspection | ||
| + | | No Violations Noted | ||
| | | | ||
| − | |||
|- | |- | ||
| + | | 2475899 | ||
| + | | Primary Facility | ||
| + | | 2016-04-07 | ||
| + | | Routine/Complete Inspection | ||
| + | | No Violations Noted | ||
| + | | Inspection to evaluate the FWI de-watering plan submitted on 3/29/2016. Plan indicates water will be discharged to the well pad surface then flow off the pad down a rock lined ditch and discharge into a small vegetated area down the slope. Erosion is a concern at several locations on the site. Along the access road and cut slope, the steep slopes are eroding. The fill slope is not stabilized and it is evident topsoil has been lost at the surface. Water flowing off the pad surface and down the fill slope has caused erosion down the fill slope east of the rock-lined ditch. The site is not permanently stabilized and has rather extensive erosion. It appears that the proposed discharge area does not meet Pa Code § 78.60(5) because the discharge area is not an undisturbed, vegetated area capable of absorbing the water. Also, the erosion caused by water flowing off the well pad raises the concern that Pa Code § 78.53 will not be met during the discharge. The Department does not recommend that the discharge | ||
| + | |- | ||
| + | | 2489715 | ||
| + | | Primary Facility | ||
| + | | 2016-06-02 | ||
| + | | Routine/Complete Inspection | ||
| + | | No Violations Noted | ||
| + | | Routine Inspection; 6/2/2016. | ||
| + | |||
| + | I entered the site off Tallman Hollow Road at 09:02 and began the inspection. At the time of the inspection, the Nature Boy East Yoder 1H (081-20920), Nature Boy East Unit 2H (081-20921), Nature Boy East Yoder 1V (081-21080), Nature Boy East Yoder 2V (081-21081), Nature Boy East Yoder 3V (081-21082), Nature Boy South Yoder 1H (081-21191), and Nature Boy South Yoder 2H (081-21192) were all in production. | ||
| + | |||
| + | A contractor was onsite scarifying, seeding, and stabilizing areas onsite which lacked vegetative cover or showed signs of erosion. The contractor was also re-grading the well pad so that water flows into the rock-lined ditch as designed and not over the fill slope. A sprinkler was set up on the north side of the well pad and had been watering a small section of the cut slope as indicated in the dewatering plan for the Fresh Water Impoundment. No Violations Noted. | ||
| + | |- | ||
| + | | 2643310 | ||
| + | | Primary Facility | ||
| + | | 2017-10-03 | ||
| + | | Routine/Complete Inspection | ||
| + | | No Violations Noted | ||
| + | | Arrived at 15:00. Weather: sunny,nice. 7 producing wells onsite. Note: well labeled Nature Boy East Yoder 2V/4H. Routine inspection. No violations observed at this time. | ||
| + | |- | ||
| + | | 2699724 | ||
| + | | Primary Facility | ||
| + | | 2018-03-01 | ||
| + | | Routine/Complete Inspection | ||
| + | | No Violations Noted | ||
| + | | Weather was 47° and cloudy with a slight wind at time of inspection. Well has a digital gauge attached to the tubing and the production casing. The gauge on the tubing read 430 psi and the gauge on the casing read 599 psi at time of inspection. There were three anulus vents plumbed to surface. Two of the annulus vents were labeled 20 and 13 and the third annulus vent was unlabeled. There was 0% combustible gas discovered on any of the vents at time of inspection. No violations were noted at time of inspection. | ||
| + | |- | ||
| + | | 2776875 | ||
| + | | Primary Facility | ||
| + | | 2018-09-19 | ||
| + | | Routine/Complete Inspection | ||
| + | | No Violations Noted | ||
| + | | Seven wells staged for production phase. Seven each water separators within containment. Dump lines wrapped in insulating blanket. No leaks detected from production equipment. No violations noted. | ||
|- | |- | ||
| − | | | + | |} |
| − | | | + | <!--==== Violations Commited ==== |
| − | | style="text-align:right;" | | + | {| class="wikitable sortable" width="95%" |
| − | | | + | !scope="col" | Inspection ID |
| − | | | + | !scope="col" | Violation ID |
| − | | | + | !scope="col" | Violation Date |
| − | | | + | !scope="col" | Date Resolved |
| − | | | + | !scope="col" | Violation Code |
| − | | | + | !scope="col" | Violation Type |
| + | !scope="col" | Violation Comments | ||
| + | |- | ||
| + | |}--> | ||
| + | <!--==== Penalties Applied ==== | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Violation ID | ||
| + | !scope="col" | Penalty ID | ||
| + | !scope="col" | Penalty Code | ||
| + | !scope="col" | Penalty Status | ||
| + | !scope="col" | Penalty Date | ||
| + | !scope="col" | Enforcement Date | ||
| + | !scope="col" | Penalty Amount | ||
| + | !scope="col" | Amount Collected | ||
| + | |- | ||
| + | |}--> | ||
| + | For data sources see<ref>{{cite web | ||
| + | | title =Oil and Gas Compliance Report | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-05-20 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-21 }}</ref> | ||
| + | == Fracking Activities == | ||
| + | ==== Fracking Jobs ==== | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Job Number | ||
| + | !scope="col" | Job Start Date | ||
| + | !scope="col" | Job End Date | ||
| + | !scope="col" | True Vertical Depth (ft) | ||
| + | !scope="col" | Total Water Volume (gal) | ||
| + | !scope="col" | Total Non-Water Volume (gal) | ||
| + | |- | ||
| + | | 1 | ||
| + | | 12/13/2013 | ||
| + | | 12/19/2013 | ||
| + | | style="text-align: right;" | 8963 | ||
| + | | style="text-align: right;" | 6,960,870.0 | ||
| + | | style="text-align: right;" | 0 | ||
| + | |- | ||
| + | |} | ||
| + | ==== Fluid Composition Data ==== | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Job Number | ||
| + | !scope="col" | Trade Name | ||
| + | !scope="col" | Supplier | ||
| + | !scope="col" | Purpose | ||
| + | !scope="col" | Ingredient Name | ||
| + | !scope="col" | CAS Number | ||
| + | !scope="col" | Additive Percentage by Mass | ||
| + | !scope="col" | Job Percentage by Mass | ||
| + | !scope="col" | Mass Used (lb) | ||
| + | |- | ||
| + | |- valign="top" | ||
| + | | rowspan="35"| 1 | ||
| + | | rowspan="8"| SI-1100 | ||
| + | | rowspan="8"| U.S. Well Services | ||
| + | | rowspan="8"| Scale Inhibitor | ||
| + | | 2-Phosphonobutane 1,2,4 tricarboxylic salt | ||
| + | | 37971-36-1 | ||
| + | | style="text-align: right;" | 10 | ||
| + | | style="text-align: right;" | 0.00198 | ||
| + | | style="text-align: right;" | 1346.98 | ||
| + | |- | ||
| + | | Potassium salt of diethylene triamine penta (methylene phosphonic acid) | ||
| + | | 15827-60-8 | ||
| + | | style="text-align: right;" | 10 | ||
| + | | style="text-align: right;" | 0.00207 | ||
| + | | style="text-align: right;" | 1409.63 | ||
| + | |- | ||
| + | | Ethylene Glycol | ||
| + | | 107-21-1 | ||
| + | | style="text-align: right;" | 40 | ||
| + | | style="text-align: right;" | 0.00693 | ||
| + | | style="text-align: right;" | 4719.64 | ||
| + | |- | ||
| + | | hexamethylenediamine tetra (methylene phosphonic acid) | ||
| + | | 38820-59-6 | ||
| + | | style="text-align: right;" | 10 | ||
| + | | style="text-align: right;" | 0.00192 | ||
| + | | style="text-align: right;" | 1305.21 | ||
| + | |- | ||
| + | | Di Water | ||
| + | | 7732-18-5 | ||
| + | | style="text-align: right;" | 80 | ||
| + | | style="text-align: right;" | 0.01226 | ||
| + | | style="text-align: right;" | 8353.34 | ||
| + | |- | ||
| + | | bis (hexamethylene) tramine penta (methylene phosphonic acid) - phosphate acid | ||
| + | | 40623-75-4 | ||
| + | | style="text-align: right;" | 10 | ||
| + | | style="text-align: right;" | 0.00176 | ||
| + | | style="text-align: right;" | 1200.79 | ||
| + | |- | ||
| + | | Copolymer of Maleic and Acrylic acid | ||
| + | | 26677-99-6 | ||
| + | | style="text-align: right;" | 10 | ||
| + | | style="text-align: right;" | 0.00181 | ||
| + | | style="text-align: right;" | 1232.12 | ||
| + | |- | ||
| + | | Acrylic polymer | ||
| + | | 52255-49-9 | ||
| + | | style="text-align: right;" | 5 | ||
| + | | style="text-align: right;" | 0.00077 | ||
| + | | style="text-align: right;" | 522.084 | ||
| + | |- | ||
| + | |- valign="top" | ||
| + | | rowspan="1"| Water | ||
| + | | rowspan="1"| Inflection Energy | ||
| + | | rowspan="1"| Base Fluid | ||
| + | | Water | ||
| + | | 7732-18-5 | ||
| + | | style="text-align: right;" | 100 | ||
| + | | style="text-align: right;" | 85.1063 | ||
| + | | style="text-align: right;" | 57,995,600.0 | ||
| + | |- | ||
| + | |- valign="top" | ||
| + | | rowspan="3"| K-BAC 1020 | ||
| + | | rowspan="3"| U.S. Well Services | ||
| + | | rowspan="3"| Anti-Bacterial Agent | ||
| + | | Polyethylene Glycol | ||
| + | | 25322-68-3 | ||
| + | | style="text-align: right;" | 50 | ||
| + | | style="text-align: right;" | 0.01082 | ||
| + | | style="text-align: right;" | 7374.56 | ||
| + | |- | ||
| + | | 2,2-dibromo-3-nitrilopropionamide | ||
| + | | 10222-01-2 | ||
| + | | style="text-align: right;" | 20 | ||
| + | | style="text-align: right;" | 0.00947 | ||
| + | | style="text-align: right;" | 6455.38 | ||
|- | |- | ||
| + | | Water | ||
| + | | 7732-18-5 | ||
| + | | style="text-align: right;" | 20 | ||
| + | | style="text-align: right;" | 0.00386 | ||
| + | | style="text-align: right;" | 2633.77 | ||
|- | |- | ||
| − | | | + | |- valign="top" |
| − | | | + | | rowspan="5"| AI-301 |
| − | | style="text-align:right;" | | + | | rowspan="5"| U.S. Well Services |
| − | | | + | | rowspan="5"| Acid Corrosion Inhibitors |
| − | | | + | | Diethylene Glycol |
| − | | | + | | 111-46-6 |
| − | + | | style="text-align: right;" | 30 | |
| − | | | + | | style="text-align: right;" | 0.00017 |
| − | + | | style="text-align: right;" | 117.589 | |
|- | |- | ||
| + | | Hydrogen Chloride | ||
| + | | 7647-01-0 | ||
| + | | style="text-align: right;" | 10 | ||
| + | | style="text-align: right;" | 0.00006000 | ||
| + | | style="text-align: right;" | 40.6325 | ||
|- | |- | ||
| − | | | + | | Methenamine |
| − | | | + | | 100-97-0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 20 |
| − | | | + | | style="text-align: right;" | 0.00014 |
| − | | | + | | style="text-align: right;" | 93.1745 |
| − | | | ||
| − | |||
| − | | | ||
| − | |||
|- | |- | ||
| + | | Polyethylene polyamine | ||
| + | | 68603-67-8 | ||
| + | | style="text-align: right;" | 10 | ||
| + | | style="text-align: right;" | 0.00005000 | ||
| + | | style="text-align: right;" | 35.2732 | ||
|- | |- | ||
| − | | | + | | Coco amine |
| − | | | + | | 61791-14-8 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 5 |
| − | | | + | | style="text-align: right;" | 0.00002000 |
| − | | | + | | style="text-align: right;" | 16.1129 |
| − | | | ||
| − | |||
| − | | | ||
| − | |||
|- | |- | ||
| + | |- valign="top" | ||
| + | | rowspan="2"| HCL Acid (12.6%-17.5%) | ||
| + | | rowspan="2"| U.S. Well Services, LLC | ||
| + | | rowspan="2"| Bulk Acid | ||
| + | | Water | ||
| + | | 7732-18-5 | ||
| + | | style="text-align: right;" | 87.4 | ||
| + | | style="text-align: right;" | 0.11229 | ||
| + | | style="text-align: right;" | 76518 | ||
|- | |- | ||
| − | | | + | | Hydrogen Chloride |
| − | | | + | | 7647-01-0 |
| − | | style="text-align:right;" | 17. | + | | style="text-align: right;" | 17.5 |
| − | | | + | | style="text-align: right;" | 0.04671 |
| − | | | + | | style="text-align: right;" | 31828.3 |
| − | | | ||
| − | |||
| − | | | ||
| − | |||
|- | |- | ||
| + | |- valign="top" | ||
| + | | rowspan="4"| LGC-15 | ||
| + | | rowspan="4"| U.S. Well Services | ||
| + | | rowspan="4"| Gelling Agents | ||
| + | | Petroleum Distillates | ||
| + | | 64742-47-8 | ||
| + | | style="text-align: right;" | 60 | ||
| + | | style="text-align: right;" | 0.00071 | ||
| + | | style="text-align: right;" | 483.386 | ||
|- | |- | ||
| − | | | + | | Surfactant |
| − | | | + | | 68439-51-0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 3 |
| − | | | + | | style="text-align: right;" | 0.00004000 |
| − | | | + | | style="text-align: right;" | 30.6245 |
| − | | | ||
| − | |||
| − | | | ||
| − | |||
|- | |- | ||
| + | | Suspending agent (solid) | ||
| + | | 14808-60-7 | ||
| + | | style="text-align: right;" | 3 | ||
| + | | style="text-align: right;" | 0.00001000 | ||
| + | | style="text-align: right;" | 3.6 | ||
|- | |- | ||
| − | | | + | | Guar Gum |
| − | | | + | | 9000-30-0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 50 |
| − | | | + | | style="text-align: right;" | 0.00009000 |
| − | | | + | | style="text-align: right;" | 60 |
| − | | | ||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| + | |- valign="top" | ||
| + | | rowspan="1"| AP One | ||
| + | | rowspan="1"| U.S. Well Services | ||
| + | | rowspan="1"| Gel Breakers | ||
| + | | Ammonium Persulfate | ||
| + | | 7727-54-0 | ||
| + | | style="text-align: right;" | 100 | ||
| + | | style="text-align: right;" | 0.00003000 | ||
| + | | style="text-align: right;" | 20 | ||
|- | |- | ||
| − | | | + | |- valign="top" |
| − | | | + | | rowspan="2"| WFRA-405e |
| − | | style="text-align:right;" | | + | | rowspan="2"| U.S. Well Services |
| − | | | + | | rowspan="2"| Friction Reducer |
| − | | | + | | Petroleum Distillates |
| − | | | + | | 64742-47-8 |
| − | + | | style="text-align: right;" | 20 | |
| − | | | + | | style="text-align: right;" | 0.00953 |
| − | + | | style="text-align: right;" | 6490.81 | |
|- | |- | ||
| + | | Sodium Chloride | ||
| + | | 7647-14-5 | ||
| + | | style="text-align: right;" | 20 | ||
| + | | style="text-align: right;" | 0.0119 | ||
| + | | style="text-align: right;" | 8111.49 | ||
|- | |- | ||
| − | | | + | |- valign="top" |
| − | | | + | | rowspan="3"| 30/50 EconoProp |
| − | | style="text-align:right;" | | + | | rowspan="3"| U.S. Well Services |
| − | + | | rowspan="3"| Ceramic Proppant | |
| − | | | + | | Mullite |
| − | | | + | | 1302-93-8 |
| − | | | + | | style="text-align: right;" | 85 |
| − | | | + | | style="text-align: right;" | 1.9006 |
| − | + | | style="text-align: right;" | 1,295,160.0 | |
|- | |- | ||
| + | | Silicon Dioxide | ||
| + | | 7631-86-9 | ||
| + | | style="text-align: right;" | 35 | ||
| + | | style="text-align: right;" | 0.09384 | ||
| + | | style="text-align: right;" | 63945 | ||
|- | |- | ||
| − | | | + | | Silica Crystalline-Cristobalite |
| − | | | + | | 14464-46-1 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 20 |
| − | | | + | | style="text-align: right;" | 0.4472 |
| − | | | + | | style="text-align: right;" | 304744 |
| − | | | ||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| + | |- valign="top" | ||
| + | | rowspan="5"| WFRA-405 | ||
| + | | rowspan="5"| U.S. Well Services | ||
| + | | rowspan="5"| Friction Reducer | ||
| + | | Ethoxylate Alcohol | ||
| + | | 68551-12-2 | ||
| + | | style="text-align: right;" | 5 | ||
| + | | style="text-align: right;" | 0.00037 | ||
| + | | style="text-align: right;" | 250.2 | ||
|- | |- | ||
| − | | | + | | Petroleum Distillates |
| − | | | + | | 64742-47-8 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 22 |
| − | | | + | | style="text-align: right;" | 0.0013 |
| − | | | + | | style="text-align: right;" | 886.208 |
| − | | | ||
| − | |||
| − | | | ||
| − | |||
|- | |- | ||
| + | | Water | ||
| + | | 7732-18-5 | ||
| + | | style="text-align: right;" | 40 | ||
| + | | style="text-align: right;" | 0.00294 | ||
| + | | style="text-align: right;" | 2001.6 | ||
|- | |- | ||
| − | | | + | | Anionic Polyacrylamide |
| − | | | + | | 62649-23-4 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 40 |
| − | | | + | | style="text-align: right;" | 0.00294 |
| − | | | + | | style="text-align: right;" | 2001.6 |
| − | | | ||
| − | | | ||
| − | |||
| − | |||
|- | |- | ||
| + | | Ammonium Chloride | ||
| + | | 12125-02-9 | ||
| + | | style="text-align: right;" | 5 | ||
| + | | style="text-align: right;" | 0.00037 | ||
| + | | style="text-align: right;" | 250.2 | ||
|- | |- | ||
| − | | | + | |- valign="top" |
| − | | | + | | rowspan="1"| Sand |
| − | | style="text-align:right;" | | + | | rowspan="1"| U.S. Well Services, LLC |
| − | + | | rowspan="1"| Proppant | |
| − | | | + | | Crystalline Silica, quartz |
| − | | | + | | 14808-60-7 |
| − | | | + | | style="text-align: right;" | 100 |
| − | | | + | | style="text-align: right;" | 12.2088 |
| − | + | | style="text-align: right;" | 8,319,640.0 | |
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
| − | | title = | + | | title =FracFocus Fracking Chemicals Database |
| − | + | | date = 2019-04-02 | |
| − | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
| − | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | accessdate = 2019-06-19 }}</ref> |
| − | | accessdate = | + | ==References== |
| − | == References == | + | <references/> |
| − | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
| − | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
| + | [[Category:FracFocus]] | ||
| Well ID: 37-081-21081 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.312442,"lon":-76.889214,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Lycoming | |
| Municipality: Upper Fairfield Township | |
| Operator Name: INFLECTION ENERGY (PA) LLC | |
| Well Pad ID: 145466 | |
| Farm/Lease Name: NATURE BOY EAST YODER 2V | |
| License Status: Active | |
| Spud Date: 06/11/2013 | |
| Permit Date: 12/11/2012 | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Latitude: 41.312442 | |
| Longitude: -76.889214 |
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2013 | INFLECTION ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2014 | INFLECTION ENERGY LLC | 1,819,320.00 | 331 | 0.00 | 0 | 0.00 | 0 |
| 2015 | INFLECTION ENERGY (PA) LLC | 1,213,030.00 | 357 | 0.00 | 0 | 0.00 | 0 |
| 2016 | INFLECTION ENERGY (PA) LLC | 1,009,774.09 | 360 | 0.00 | 0 | 0.00 | 0 |
| 2017 | INFLECTION ENERGY (PA) LLC | 1,051,838.00 | 364 | 0.00 | 0 | 0.00 | 0 |
| 2018 | INFLECTION ENERGY (PA) LLC | 828,640.00 | 353 | 0.00 | 0 | 0.00 | 0 |
| 2019 | INFLECTION ENERGY (PA) LLC | 190,932.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
| Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|
| 2013-S02 | Drill Cuttings (in Tons) | 176.87 Tons | LANDFILL | 301626 |
| 2013-S02 | Drilling Fluid Waste (in Barrels) | 864.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
| 2013-S02 | Fracturing Fluid Waste (in Tons) | 590.13 Tons | LANDFILL | 301626 |
| 2014-S01 | Drill Cuttings (in Tons) | 176.87 Tons | LANDFILL | 301626 |
| 2014-S01 | Drilling Fluid Waste (in Barrels) | 864.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
| 2014-S01 | Fracturing Fluid Waste (in Tons) | 590.13 Tons | LANDFILL | 301626 |
| 2014-S02 | Produced Fluid (in Barrels) | 2,816.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015-M02 | Produced Fluid (in Barrels) | 381.30 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015-S02 | Produced Fluid (in Barrels) | 894.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016-S01 | Produced Fluid (in Barrels) RWC 802 | 488.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016-S01 | Waste Water Treatment Sludge (in Tons) RWC 804 | 4.83 Tons | LANDFILL | 301626 |
| 2016-S02 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2016-S02 | Produced Fluid (in Barrels) RWC 802 | 582.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2017-M01 | Produced Fluid (in Barrels) RWC 802 | 157.70 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2017-M02 | Produced Fluid (in Barrels) RWC 802 | 61.23 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
| 2017-M02 | Produced Fluid (in Barrels) RWC 802 | 37.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
| 2017-M03 | Produced Fluid (in Barrels) RWC 802 | 62.85 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
| 2017-M03 | Produced Fluid (in Barrels) RWC 802 | 53.62 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2017-M04 | Produced Fluid (in Barrels) RWC 802 | 83.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2017-M04 | Produced Fluid (in Barrels) RWC 802 | 35.31 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2017-M05 | Produced Fluid (in Barrels) RWC 802 | 106.50 Bbl | REUSE (AT WELL PAD) | |
| 2017-M06 | Produced Fluid (in Barrels) RWC 802 | 48.57 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
| 2017-M06 | Produced Fluid (in Barrels) RWC 802 | 18.60 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
| 2017-M06 | Produced Fluid (in Barrels) RWC 802 | 15.40 Bbl | REUSE (AT WELL PAD) | |
| 2017-M07 | Produced Fluid (in Barrels) RWC 802 | 54.94 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2017-M07 | Produced Fluid (in Barrels) RWC 802 | 30.57 Bbl | REUSE (AT WELL PAD) | |
| 2017-M08 | Produced Fluid (in Barrels) RWC 802 | 94.28 Bbl | REUSE (AT WELL PAD) | |
| 2017-M09 | Produced Fluid (in Barrels) RWC 802 | 38.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2017-M10 | Produced Fluid (in Barrels) RWC 802 | 114.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-M11 | Produced Fluid (in Barrels) RWC 802 | 97.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-M12 | Produced Fluid (in Barrels) RWC 802 | 77.84 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2018-M01 | Produced Fluid (in Barrels) RWC 802 | 37.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2018-M02 | Produced Fluid (in Barrels) RWC 802 | 80.00 Bbl | REUSE (AT WELL PAD) | |
| 2018-M03 | Produced Fluid (in Barrels) RWC 802 | 80.00 Bbl | REUSE (AT WELL PAD) | |
| 2018-M05 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 45.71 Bbl | REUSE (AT WELL PAD) | |
| 2018-M05 | Produced Fluid (in Barrels) RWC 802 | 139.71 Bbl | REUSE (AT WELL PAD) | |
| 2018-M06 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 17.00 Bbl | REUSE (AT WELL PAD) | |
| 2018-M06 | Produced Fluid (in Barrels) RWC 802 | 51.00 Bbl | REUSE (AT WELL PAD) | |
| 2018-M07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 14.28 Bbl | REUSE (AT WELL PAD) | |
| 2018-M07 | Produced Fluid (in Barrels) RWC 802 | 74.29 Bbl | REUSE (AT WELL PAD) | |
| 2018-M08 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 44.00 Bbl | REUSE (AT WELL PAD) | |
| 2018-M08 | Produced Fluid (in Barrels) RWC 802 | 62.00 Bbl | REUSE (AT WELL PAD) | |
| 2018-M09 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 25.71 Bbl | REUSE (AT WELL PAD) | |
| 2018-M09 | Produced Fluid (in Barrels) RWC 802 | 51.43 Bbl | REUSE (AT WELL PAD) | |
| 2018-M10 | Produced Fluid (in Barrels) RWC 802 | 82.00 Bbl | REUSE (AT WELL PAD) | |
| 2018-M11 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 11.43 Bbl | REUSE (AT WELL PAD) | |
| 2018-M11 | Produced Fluid (in Barrels) RWC 802 | 34.29 Bbl | REUSE (AT WELL PAD) | |
| 2018-M12 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 37.71 Bbl | REUSE (AT WELL PAD) | |
| 2018-M12 | Produced Fluid (in Barrels) RWC 802 | 62.85 Bbl | REUSE (AT WELL PAD) | |
| 2019-M01 | Produced Fluid (in Barrels) RWC 802 | 45.70 Bbl | REUSE (AT WELL PAD) | |
| 2019-M02 | Produced Fluid (in Barrels) RWC 802 | 71.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2019-M03 | Produced Fluid (in Barrels) RWC 802 | 18.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2019-M03 | Produced Fluid (in Barrels) RWC 802 | 79.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2130018 | Primary Facility | 01/10/2013 | Routine/Complete Inspection | No Violations Noted | |
| 2184074 | Primary Facility | 07/08/2013 | Routine/Complete Inspection | No Violations Noted | Brine/produced water spill. Sumps dug in the fill slope and are recovering spilled material. Violations cited ot the 081-21080 well |
| 2230427 | Primary Facility | 12/18/2013 | Routine/Complete Inspection | No Violations Noted | |
| 2266779 | Primary Facility | 04/11/2014 | Drilling/Alteration | No Violations Noted | |
| 2444783 | Primary Facility | 2016-01-26 | Routine/Complete Inspection | No Violations Noted | |
| 2475899 | Primary Facility | 2016-04-07 | Routine/Complete Inspection | No Violations Noted | Inspection to evaluate the FWI de-watering plan submitted on 3/29/2016. Plan indicates water will be discharged to the well pad surface then flow off the pad down a rock lined ditch and discharge into a small vegetated area down the slope. Erosion is a concern at several locations on the site. Along the access road and cut slope, the steep slopes are eroding. The fill slope is not stabilized and it is evident topsoil has been lost at the surface. Water flowing off the pad surface and down the fill slope has caused erosion down the fill slope east of the rock-lined ditch. The site is not permanently stabilized and has rather extensive erosion. It appears that the proposed discharge area does not meet Pa Code § 78.60(5) because the discharge area is not an undisturbed, vegetated area capable of absorbing the water. Also, the erosion caused by water flowing off the well pad raises the concern that Pa Code § 78.53 will not be met during the discharge. The Department does not recommend that the discharge |
| 2489715 | Primary Facility | 2016-06-02 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 6/2/2016.
I entered the site off Tallman Hollow Road at 09:02 and began the inspection. At the time of the inspection, the Nature Boy East Yoder 1H (081-20920), Nature Boy East Unit 2H (081-20921), Nature Boy East Yoder 1V (081-21080), Nature Boy East Yoder 2V (081-21081), Nature Boy East Yoder 3V (081-21082), Nature Boy South Yoder 1H (081-21191), and Nature Boy South Yoder 2H (081-21192) were all in production. A contractor was onsite scarifying, seeding, and stabilizing areas onsite which lacked vegetative cover or showed signs of erosion. The contractor was also re-grading the well pad so that water flows into the rock-lined ditch as designed and not over the fill slope. A sprinkler was set up on the north side of the well pad and had been watering a small section of the cut slope as indicated in the dewatering plan for the Fresh Water Impoundment. No Violations Noted. |
| 2643310 | Primary Facility | 2017-10-03 | Routine/Complete Inspection | No Violations Noted | Arrived at 15:00. Weather: sunny,nice. 7 producing wells onsite. Note: well labeled Nature Boy East Yoder 2V/4H. Routine inspection. No violations observed at this time. |
| 2699724 | Primary Facility | 2018-03-01 | Routine/Complete Inspection | No Violations Noted | Weather was 47° and cloudy with a slight wind at time of inspection. Well has a digital gauge attached to the tubing and the production casing. The gauge on the tubing read 430 psi and the gauge on the casing read 599 psi at time of inspection. There were three anulus vents plumbed to surface. Two of the annulus vents were labeled 20 and 13 and the third annulus vent was unlabeled. There was 0% combustible gas discovered on any of the vents at time of inspection. No violations were noted at time of inspection. |
| 2776875 | Primary Facility | 2018-09-19 | Routine/Complete Inspection | No Violations Noted | Seven wells staged for production phase. Seven each water separators within containment. Dump lines wrapped in insulating blanket. No leaks detected from production equipment. No violations noted. |
For data sources see[6]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 12/13/2013 | 12/19/2013 | 8963 | 6,960,870.0 | 0 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | SI-1100 | U.S. Well Services | Scale Inhibitor | 2-Phosphonobutane 1,2,4 tricarboxylic salt | 37971-36-1 | 10 | 0.00198 | 1346.98 |
| Potassium salt of diethylene triamine penta (methylene phosphonic acid) | 15827-60-8 | 10 | 0.00207 | 1409.63 | ||||
| Ethylene Glycol | 107-21-1 | 40 | 0.00693 | 4719.64 | ||||
| hexamethylenediamine tetra (methylene phosphonic acid) | 38820-59-6 | 10 | 0.00192 | 1305.21 | ||||
| Di Water | 7732-18-5 | 80 | 0.01226 | 8353.34 | ||||
| bis (hexamethylene) tramine penta (methylene phosphonic acid) - phosphate acid | 40623-75-4 | 10 | 0.00176 | 1200.79 | ||||
| Copolymer of Maleic and Acrylic acid | 26677-99-6 | 10 | 0.00181 | 1232.12 | ||||
| Acrylic polymer | 52255-49-9 | 5 | 0.00077 | 522.084 | ||||
| Water | Inflection Energy | Base Fluid | Water | 7732-18-5 | 100 | 85.1063 | 57,995,600.0 | |
| K-BAC 1020 | U.S. Well Services | Anti-Bacterial Agent | Polyethylene Glycol | 25322-68-3 | 50 | 0.01082 | 7374.56 | |
| 2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20 | 0.00947 | 6455.38 | ||||
| Water | 7732-18-5 | 20 | 0.00386 | 2633.77 | ||||
| AI-301 | U.S. Well Services | Acid Corrosion Inhibitors | Diethylene Glycol | 111-46-6 | 30 | 0.00017 | 117.589 | |
| Hydrogen Chloride | 7647-01-0 | 10 | 0.00006000 | 40.6325 | ||||
| Methenamine | 100-97-0 | 20 | 0.00014 | 93.1745 | ||||
| Polyethylene polyamine | 68603-67-8 | 10 | 0.00005000 | 35.2732 | ||||
| Coco amine | 61791-14-8 | 5 | 0.00002000 | 16.1129 | ||||
| HCL Acid (12.6%-17.5%) | U.S. Well Services, LLC | Bulk Acid | Water | 7732-18-5 | 87.4 | 0.11229 | 76518 | |
| Hydrogen Chloride | 7647-01-0 | 17.5 | 0.04671 | 31828.3 | ||||
| LGC-15 | U.S. Well Services | Gelling Agents | Petroleum Distillates | 64742-47-8 | 60 | 0.00071 | 483.386 | |
| Surfactant | 68439-51-0 | 3 | 0.00004000 | 30.6245 | ||||
| Suspending agent (solid) | 14808-60-7 | 3 | 0.00001000 | 3.6 | ||||
| Guar Gum | 9000-30-0 | 50 | 0.00009000 | 60 | ||||
| AP One | U.S. Well Services | Gel Breakers | Ammonium Persulfate | 7727-54-0 | 100 | 0.00003000 | 20 | |
| WFRA-405e | U.S. Well Services | Friction Reducer | Petroleum Distillates | 64742-47-8 | 20 | 0.00953 | 6490.81 | |
| Sodium Chloride | 7647-14-5 | 20 | 0.0119 | 8111.49 | ||||
| 30/50 EconoProp | U.S. Well Services | Ceramic Proppant | Mullite | 1302-93-8 | 85 | 1.9006 | 1,295,160.0 | |
| Silicon Dioxide | 7631-86-9 | 35 | 0.09384 | 63945 | ||||
| Silica Crystalline-Cristobalite | 14464-46-1 | 20 | 0.4472 | 304744 | ||||
| WFRA-405 | U.S. Well Services | Friction Reducer | Ethoxylate Alcohol | 68551-12-2 | 5 | 0.00037 | 250.2 | |
| Petroleum Distillates | 64742-47-8 | 22 | 0.0013 | 886.208 | ||||
| Water | 7732-18-5 | 40 | 0.00294 | 2001.6 | ||||
| Anionic Polyacrylamide | 62649-23-4 | 40 | 0.00294 | 2001.6 | ||||
| Ammonium Chloride | 12125-02-9 | 5 | 0.00037 | 250.2 | ||||
| Sand | U.S. Well Services, LLC | Proppant | Crystalline Silica, quartz | 14808-60-7 | 100 | 12.2088 | 8,319,640.0 |
For data sources see[7]