X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-081-21191"

m
m
 
(4 intermediate revisions by the same user not shown)
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-081-21191
 
| Well ID: 37-081-21191
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.31233, -76.889261 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.312447, -76.889442 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Lycoming County, Pennsylvania|Lycoming]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Upper Fairfield Township, Lycoming County, Pennsylvania|Upper Fairfield Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[INFLECTION ENERGY  LLC]]
+
| County: [[Lycoming_County,_Pennsylvania|Lycoming]]
 
|-
 
|-
| Well Pad ID: [[145466|145466]]
+
| Municipality: [[Upper Fairfield Township,_Lycoming_County,_Pennsylvania|Upper Fairfield Township]]
 +
|-
 +
| Operator Name: [[INFLECTION ENERGY (PA) LLC]]
 +
|-
 +
| Well Pad ID: [[145466]]
 
|-
 
|-
 
| Farm/Lease Name: NATURE BOY SOUTH YODER 1H
 
| Farm/Lease Name: NATURE BOY SOUTH YODER 1H
 
|-
 
|-
| First Permit Date: 2013-06-21
+
| License Status:
 +
|-
 +
| Spud Date:
 +
|-
 +
| Permit Date: 2013-06-21
 +
|-
 +
| Well Type: GAS
 +
|-
 +
| Unconventional Well: Y
 +
|-
 +
| Configuration: Horizontal Well
 
|-
 
|-
| Last Permit Date: 2013-06-21
+
| Conservation: Yes
 
|-
 
|-
| Spud Date: 2013-11-21
+
| Latitude: 41.312447
 
|-
 
|-
| Unconventional: Yes
+
| Longitude: -76.889442
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 
|-
 
|-
| Horizontal: Yes
+
| 2013-06-21
 +
| New Permit Application
 
|-
 
|-
| Well Status: ACTIVE
+
| 2013-11-21
 +
| Performed Spud Operation
 
|-
 
|-
| Violations: 0
+
| 2018-03-14
 +
| MOD
 
|-
 
|-
| Latitude: 41.31233
+
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|-
| Longitude: -76.889261
+
| 1
 +
| 2013-12-28
 +
| 2014-01-01
 +
| style="text-align: right;" | 8,579
 +
| style="text-align: right;" | 5,474,360
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
== Production Data ==
+
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Job Number
!scope="col" | GAS QUANTITY
+
!scope="col" | Trade Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Supplier
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Purpose
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Ingredient Name
!scope="col" | OIL QUANTITY
+
!scope="col" | CAS Number
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="32"| 1
 +
| rowspan="5"| AI-301
 +
| rowspan="5"| U.S. Well Services
 +
| rowspan="5"| Acid Corrosion Inhibitors
 +
| Hydrogen Chloride
 +
| 7647-01-0
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.0001
 +
| style="text-align: right;" | 49.3394
 +
|-
 +
| Diethylene Glycol
 +
| 111-46-6
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00028
 +
| style="text-align: right;" | 142.787
 +
|-
 +
| Polyethylene polyamine
 +
| 68603-67-8
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00008000
 +
| style="text-align: right;" | 42.8317
 +
|-
 +
| Coco amine
 +
| 61791-14-8
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00004000
 +
| style="text-align: right;" | 19.5656
 +
|-
 +
| Methenamine
 +
| 100-97-0
 +
| style="text-align: right;" | 20
 +
| style="text-align: right;" | 0.00022
 +
| style="text-align: right;" | 113.14
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand
 +
| rowspan="1"| U.S. Well Services, LLC
 +
| rowspan="1"| Proppant
 +
| Crystalline Silica, quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 11.2281
 +
| style="text-align: right;" | 5,791,360.0
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| WFRA-405e
 +
| rowspan="2"| U.S. Well Services
 +
| rowspan="2"| Friction Reducer
 +
| Petroleum Distillates
 +
| 64742-47-8
 +
| style="text-align: right;" | 20
 +
| style="text-align: right;" | 0.00987
 +
| style="text-align: right;" | 5090.33
 +
|-
 +
| Sodium Chloride
 +
| 7647-14-5
 +
| style="text-align: right;" | 20
 +
| style="text-align: right;" | 0.01233
 +
| style="text-align: right;" | 6361.33
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| AP One
 +
| rowspan="1"| U.S. Well Services
 +
| rowspan="1"| Gel Breakers
 +
| Ammonium Persulfate
 +
| 7727-54-0
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 0.00021
 +
| style="text-align: right;" | 106
 +
|-
 +
|- valign="top"
 +
| rowspan="5"| WFRA-405
 +
| rowspan="5"| U.S. Well Services
 +
| rowspan="5"| Friction Reducer
 +
| Ammonium Chloride
 +
| 12125-02-9
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00033
 +
| style="text-align: right;" | 168.051
 
|-
 
|-
| 2013-2
+
| Petroleum Distillates
| style="text-align:right;" | 0.0
+
| 64742-47-8
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 22
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00115
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 595.237
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| Anionic Polyacrylamide
 +
| 62649-23-4
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 0.00261
 +
| style="text-align: right;" | 1344.41
 
|-
 
|-
| 2014-1
+
| Water
| style="text-align:right;" | 652909.0
+
| 7732-18-5
| style="text-align:right;" | 146.0
+
| style="text-align: right;" | 40
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00261
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 1344.41
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| Ethoxylate Alcohol
 +
| 68551-12-2
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00033
 +
| style="text-align: right;" | 168.051
 
|-
 
|-
| 2014-2
+
|- valign="top"
| style="text-align:right;" | 671931.0
+
| rowspan="2"| HCL Acid (12.6%-17.5%)
| style="text-align:right;" | 181.0
+
| rowspan="2"| U.S. Well Services, LLC
| style="text-align:right;" | 0.0
+
| rowspan="2"| Bulk Acid
| style="text-align:right;" | 0.0
+
| Water
| style="text-align:right;" | 0.0
+
| 7732-18-5
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 87.4
 +
| style="text-align: right;" | 0.17884
 +
| style="text-align: right;" | 92242.9
 
|-
 
|-
 +
| Hydrogen Chloride
 +
| 7647-01-0
 +
| style="text-align: right;" | 17.5
 +
| style="text-align: right;" | 0.07439
 +
| style="text-align: right;" | 38369.3
 
|-
 
|-
| 2015-02
+
|- valign="top"
| style="text-align:right;" | 86982.45
+
| rowspan="8"| SI-1100
| style="text-align:right;" | 28.0
+
| rowspan="8"| U.S. Well Services
| style="text-align:right;" | 0.0
+
| rowspan="8"| Scale Inhibitor
| style="text-align:right;" | 0.0
+
| Di Water
| style="text-align:right;" | 0.0
+
| 7732-18-5
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 80
 +
| style="text-align: right;" | 0.0138
 +
| style="text-align: right;" | 7119.02
 
|-
 
|-
 +
| 2-Phosphonobutane 1,2,4 tricarboxylic salt
 +
| 37971-36-1
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00223
 +
| style="text-align: right;" | 1147.94
 
|-
 
|-
| 2015-01
+
| bis (hexamethylene) tramine penta<br/> (methylene phosphonic acid) - phosphate acid
| style="text-align:right;" | 94823.69
+
| 40623-75-4
| style="text-align:right;" | 30.0
+
| style="text-align: right;" | 10
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00198
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 1023.36
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| hexamethylenediamine tetra (methylene phosphonic acid)
 +
| 38820-59-6
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00216
 +
| style="text-align: right;" | 1112.35
 
|-
 
|-
| 2015-03
+
| Copolymer of Maleic and Acrylic acid
| style="text-align:right;" | 96267.0
+
| 26677-99-6
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 10
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00204
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 1050.06
| style="text-align:right;" | 0.0
+
|-
| style="text-align:right;" | 0.0
+
| Acrylic polymer
 +
| 52255-49-9
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00086
 +
| style="text-align: right;" | 444.939
 +
|-
 +
| Potassium salt of diethylene triamine<br/> penta (methylene phosphonic acid)
 +
| 15827-60-8
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00233
 +
| style="text-align: right;" | 1201.34
 +
|-
 +
| Ethylene Glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 0.0078
 +
| style="text-align: right;" | 4022.25
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"| Inflection Energy
 +
| rowspan="1"| Base Fluid
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 88.4279
 +
| style="text-align: right;" | 45,610,500.0
 +
|-
 +
|- valign="top"
 +
| rowspan="3"| K-BAC 1020
 +
| rowspan="3"| U.S. Well Services
 +
| rowspan="3"| Anti-Bacterial Agent
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 20
 +
| style="text-align: right;" | 0.00367
 +
| style="text-align: right;" | 1891.51
 +
|-
 +
| 2,2-dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 20
 +
| style="text-align: right;" | 0.00899
 +
| style="text-align: right;" | 4636.1
 +
|-
 +
| Polyethylene Glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 50
 +
| style="text-align: right;" | 0.01027
 +
| style="text-align: right;" | 5296.23
 +
|-
 +
|- valign="top"
 +
| rowspan="4"| LGC-15
 +
| rowspan="4"| U.S. Well Services
 +
| rowspan="4"| Gelling Agents
 +
| Petroleum Distillates
 +
| 64742-47-8
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00381
 +
| style="text-align: right;" | 1965.77
 +
|-
 +
| Surfactant
 +
| 68439-51-0
 +
| style="text-align: right;" | 3
 +
| style="text-align: right;" | 0.00024
 +
| style="text-align: right;" | 124.54
 +
|-
 +
| Guar Gum
 +
| 9000-30-0
 +
| style="text-align: right;" | 50
 +
| style="text-align: right;" | 0.00047
 +
| style="text-align: right;" | 244
 +
|-
 +
| Suspending agent (solid)
 +
| 14808-60-7
 +
| style="text-align: right;" | 3
 +
| style="text-align: right;" | 0.00003000
 +
| style="text-align: right;" | 14.64
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
| title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
| accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 +
|-
 +
| 2013
 +
| [[INFLECTION ENERGY LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2014
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| style="text-align: right;" | 1,324,840.00
 +
| style="text-align: right;" | 327
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2015
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| style="text-align: right;" | 928,242.41
 +
| style="text-align: right;" | 356
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2016
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| style="text-align: right;" | 739,817.71
 +
| style="text-align: right;" | 360
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2017
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| style="text-align: right;" | 804,807.00
 +
| style="text-align: right;" | 364
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2018
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| style="text-align: right;" | 611,381.00
 +
| style="text-align: right;" | 354
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2019
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| style="text-align: right;" | 527,333.04
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
  | title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
  | accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Operator
!scope="col" | QUANTITY
+
!scope="col" | Waste Type
!scope="col" | UNITS
+
!scope="col" | Quantity
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Disposal Method
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2013-2
+
| 2013
| DRILLING FLUID WASTE
+
| [[INFLECTION ENERGY LLC]]
| style="text-align:right;" | 864.0
+
| Drilling Fluid Waste
| Bbl
+
| style="text-align: right;" | 864.00 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR123D001X
+
| WMGR123SW018
| TERRAQUA RESOURCE MANAGEMENT
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 3.17 Tons
 +
| LANDFILL
 +
| 301626
 +
|-
 +
| 2014
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 2,816.66 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2014-1
+
| 2014
| DRILLING FLUID WASTE
+
| [[INFLECTION ENERGY LLC]]
| style="text-align:right;" | 864.0
+
| Drilling Fluid Waste
| Bbl
+
| style="text-align: right;" | 864.00 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR123D001X
+
| WMGR123SW018
| TERRAQUA RESOURCE MANAGEMENT
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
 +
| 2015
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,275.90 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,070.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2014-2
+
| 2016
| DRILL CUTTINGS
+
| [[INFLECTION ENERGY (PA) LLC]]
| style="text-align:right;" | 3.17
+
| Produced Fluid
| Tons
+
| style="text-align: right;" | 40.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 +
|-
 +
| 2016
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Waste Water Treatment Sludge
 +
| style="text-align: right;" | 4.83 Tons
 
| LANDFILL
 
| LANDFILL
 
| 301626
 
| 301626
| WHITE PINES LANDFILL
 
| MILLVILLE
 
| PA
 
 
|-
 
|-
 +
| 2017
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 113.16 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2017
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 172.65 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR119
 +
|-
 +
| 2017
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 458.75 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 386.95 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 +
|-
 +
| 2017
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 56.31 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW005
 
|-
 
|-
| 2014-2
+
| 2017
| PRODUCED FLUID
+
| [[INFLECTION ENERGY (PA) LLC]]
| style="text-align:right;" | 2.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 685.81 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 591.59 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 290.84 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 37.71 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 
|-
 
|-
| 15FEBU
+
| 2019
| PRODUCED FLUID
+
| [[INFLECTION ENERGY (PA) LLC]]
| style="text-align:right;" | 381.3
+
| Synthetic Liner Materials
| Bbl
+
| style="text-align: right;" | 4.41 Tons
| REUSE OTHER THAN ROAD SPREADING
+
 
|
 
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
 
|
 
 
|  
 
|  
 
|-
 
|-
 +
| 2019
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 2.57 Tons
 +
| LANDFILL
 +
| 100955
 +
|-
 +
| 2019
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Synthetic Liner Materials
 +
| style="text-align: right;" | 1.26 Tons
 +
| LANDFILL
 +
| 100955
 +
|-
 +
| 2019
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 3.52 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 +
|-
 +
| 2019
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 89.42 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW011
 
|-
 
|-
| 15FEBU
+
| 2019
| PRODUCED FLUID
+
| [[INFLECTION ENERGY (PA) LLC]]
| style="text-align:right;" | 381.3
+
| Synthetic Liner Materials
| Bbl
+
| style="text-align: right;" | 4.41 Tons
| REUSE OTHER THAN ROAD SPREADING
+
| BENEFICIAL REUSE ?PERMIT
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2019
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 57.14 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 404.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 20.00 Bbl
 +
| RESIDUAL WASTE TRANSFER FACILITY
 +
| WMGR123NC039
 +
|-
 +
| 2019
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 60.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC018
 +
|-
 +
| 2019
 +
| [[INFLECTION ENERGY (PA) LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 18.57 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR119
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-26 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| 2230430
 
| 2230430
 +
| Primary Facility
 
| 2013-12-18
 
| 2013-12-18
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2266766
 +
| Primary Facility
 +
| 2014-04-11
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2445329
 +
| Primary Facility
 +
| 2016-01-26
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2475900
 +
| Primary Facility
 +
| 2016-04-07
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Inspection to evaluate the FWI de-watering plan submitted on 3/29/2016.  Plan indicates water will be discharged to the well pad surface then flow off the pad down a rock lined ditch and discharge into a small vegetated area down the slope.  Erosion is a concern at several locations on the site.  Along the access road and cut slope, the steep slopes are eroding.  The fill slope is not stabilized and it is evident topsoil has been lost at the surface.  Water flowing off the pad surface and down the fill slope has caused erosion down the fill slope east of the rock-lined ditch. The site is not permanently stabilized and has rather extensive erosion.  It appears that the proposed discharge area does not meet Pa Code § 78.60(5) because the discharge area is not an undisturbed, vegetated area capable of absorbing the water.  Also, the erosion caused by water flowing off the well pad raises the concern that Pa Code § 78.53 will not be met during the discharge.  The Department does not recommend that the discharge
 +
|-
 +
| 2489719
 +
| Primary Facility
 +
| 2016-06-02
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Routine Inspection; 6/2/2016.
 +
 +
I entered the site off Tallman Hollow Road at 09:02 and began the inspection.  At the time of the inspection, the Nature Boy East Yoder 1H (081-20920), Nature Boy East Unit 2H (081-20921), Nature Boy East Yoder 1V (081-21080), Nature Boy East Yoder 2V (081-21081), Nature Boy East Yoder 3V (081-21082), Nature Boy South Yoder 1H (081-21191), and Nature Boy South Yoder 2H (081-21192) were all in production. 
 +
 +
A contractor was onsite scarifying, seeding, and stabilizing areas onsite which lacked vegetative cover or showed signs of erosion.  The contractor was also re-grading the well pad so that water flows into the rock-lined ditch as designed and not over the fill slope.  A sprinkler was set up on the north side of the well pad and had been watering a small section of the cut slope as indicated in the dewatering plan for the Fresh Water Impoundment.  No Violations Noted.
 +
|-
 +
| 2605770
 +
| Primary Facility
 +
| 2017-06-20
 +
| Administrative/File Review
 +
| Violation(s) Noted
 +
| Administrative Inspection entered for the purpose of entering an Enforcement Record (NOV).
 +
 +
VIOLS closed (CRCTD) 3/14/2018 upon issuance of permit modification.
 +
|-
 +
| 2643332
 +
| Primary Facility
 +
| 2017-10-03
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Arrived at 15:00. Weather: sunny,nice. 7 producing wells onsite. Routine inspection. No violations observed at this time.
 +
|-
 +
| 2699738
 +
| Primary Facility
 +
| 2018-03-01
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Weather was 47° and cloudy with a slight wind at time of inspection. Well has a digital gauge attached to the tubing and the production casing. The gauge on the tubing read 326 psi and the gauge on the casing read 492 psi at time of inspection. There were three anulus vents plumbed to surface. Two of the annulus vents were labeled 20 and 13 and the third annulus vent was unlabeled. There was 0% combustible gas discovered on any of the vents at time of inspection. No violations were noted at time of inspection.
 +
|-
 +
| 2776879
 +
| Primary Facility
 +
| 2018-09-19
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Seven wells staged for production phase. Seven each water separators within containment. Dump lines wrapped in insulating blanket. No leaks detected from production equipment. No violations noted.
 +
|-
 +
|}
 +
==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
| 2605770
 +
| 788471
 +
| 2017-06-20
 +
| 2018-03-14
 +
| OGA3211(F1)
 +
| Administrative
 +
| Well was intentionally drilled at a Surface Hole Location (SHL) other than the approved SHL on the well permit, resulting in the actual SHL being approximately 65 feet from the permitted SHL.
 +
|-
 +
| 2605770
 +
| 788472
 +
| 2017-06-20
 +
| 2018-03-14
 +
| 78a12
 +
| Administrative
 +
| The well was not drilled in accordance with the approved well permit.  The actual SHL is approximately 65 feet from the permitted SHL.  The maximum True Vertical Depth (TVD) reported in the deviation survey (8,147 feet) exceeds the permitted anticipated TVD (7,806 feet) by 341 feet.  The Bottom Hole
 +
|-
 +
|}
 +
==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
| 788471
 +
| 354437
 +
| NOV - Notice of Violation
 +
|
 +
|
 +
| 2018-03-14
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| 788472
 +
| 354437
 +
| NOV - Notice of Violation
 
|  
 
|  
 
|  
 
|  
 +
| 2018-03-14
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =Oil and Gas Compliance Report
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-05-20
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 01:40, 17 May 2020

Well Details

Well ID: 37-081-21191
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Upper Fairfield Township
Operator Name: INFLECTION ENERGY (PA) LLC
Well Pad ID: 145466
Farm/Lease Name: NATURE BOY SOUTH YODER 1H
License Status:
Spud Date:
Permit Date: 2013-06-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.312447
Longitude: -76.889442

For data sources see[1][2][3]

Well History

Date Event
2013-06-21 New Permit Application
2013-11-21 Performed Spud Operation
2018-03-14 MOD

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-12-28 2014-01-01 8,579 5,474,360 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 AI-301 U.S. Well Services Acid Corrosion Inhibitors Hydrogen Chloride 7647-01-0 10 0.0001 49.3394
Diethylene Glycol 111-46-6 30 0.00028 142.787
Polyethylene polyamine 68603-67-8 10 0.00008000 42.8317
Coco amine 61791-14-8 5 0.00004000 19.5656
Methenamine 100-97-0 20 0.00022 113.14
Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 11.2281 5,791,360.0
WFRA-405e U.S. Well Services Friction Reducer Petroleum Distillates 64742-47-8 20 0.00987 5090.33
Sodium Chloride 7647-14-5 20 0.01233 6361.33
AP One U.S. Well Services Gel Breakers Ammonium Persulfate 7727-54-0 100 0.00021 106
WFRA-405 U.S. Well Services Friction Reducer Ammonium Chloride 12125-02-9 5 0.00033 168.051
Petroleum Distillates 64742-47-8 22 0.00115 595.237
Anionic Polyacrylamide 62649-23-4 40 0.00261 1344.41
Water 7732-18-5 40 0.00261 1344.41
Ethoxylate Alcohol 68551-12-2 5 0.00033 168.051
HCL Acid (12.6%-17.5%) U.S. Well Services, LLC Bulk Acid Water 7732-18-5 87.4 0.17884 92242.9
Hydrogen Chloride 7647-01-0 17.5 0.07439 38369.3
SI-1100 U.S. Well Services Scale Inhibitor Di Water 7732-18-5 80 0.0138 7119.02
2-Phosphonobutane 1,2,4 tricarboxylic salt 37971-36-1 10 0.00223 1147.94
bis (hexamethylene) tramine penta
(methylene phosphonic acid) - phosphate acid
40623-75-4 10 0.00198 1023.36
hexamethylenediamine tetra (methylene phosphonic acid) 38820-59-6 10 0.00216 1112.35
Copolymer of Maleic and Acrylic acid 26677-99-6 10 0.00204 1050.06
Acrylic polymer 52255-49-9 5 0.00086 444.939
Potassium salt of diethylene triamine
penta (methylene phosphonic acid)
15827-60-8 10 0.00233 1201.34
Ethylene Glycol 107-21-1 40 0.0078 4022.25
Water Inflection Energy Base Fluid Water 7732-18-5 100 88.4279 45,610,500.0
K-BAC 1020 U.S. Well Services Anti-Bacterial Agent Water 7732-18-5 20 0.00367 1891.51
2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.00899 4636.1
Polyethylene Glycol 25322-68-3 50 0.01027 5296.23
LGC-15 U.S. Well Services Gelling Agents Petroleum Distillates 64742-47-8 60 0.00381 1965.77
Surfactant 68439-51-0 3 0.00024 124.54
Guar Gum 9000-30-0 50 0.00047 244
Suspending agent (solid) 14808-60-7 3 0.00003000 14.64

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 INFLECTION ENERGY LLC 0.00 0 0.00 0 0.00 0
2014 INFLECTION ENERGY (PA) LLC 1,324,840.00 327 0.00 0 0.00 0
2015 INFLECTION ENERGY (PA) LLC 928,242.41 356 0.00 0 0.00 0
2016 INFLECTION ENERGY (PA) LLC 739,817.71 360 0.00 0 0.00 0
2017 INFLECTION ENERGY (PA) LLC 804,807.00 364 0.00 0 0.00 0
2018 INFLECTION ENERGY (PA) LLC 611,381.00 354 0.00 0 0.00 0
2019 INFLECTION ENERGY (PA) LLC 527,333.04 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 INFLECTION ENERGY LLC Drilling Fluid Waste 864.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014 INFLECTION ENERGY (PA) LLC Drill Cuttings 3.17 Tons LANDFILL 301626
2014 INFLECTION ENERGY (PA) LLC Produced Fluid 2,816.66 Bbl REUSE OTHER THAN ROAD SPREADING
2014 INFLECTION ENERGY LLC Drilling Fluid Waste 864.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2015 INFLECTION ENERGY (PA) LLC Produced Fluid 1,275.90 Bbl REUSE OTHER THAN ROAD SPREADING
2016 INFLECTION ENERGY (PA) LLC Produced Fluid 1,070.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 INFLECTION ENERGY (PA) LLC Produced Fluid 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016 INFLECTION ENERGY (PA) LLC Waste Water Treatment Sludge 4.83 Tons LANDFILL 301626
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 113.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 172.65 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 458.75 Bbl REUSE (AT WELL PAD)
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 386.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 56.31 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 685.81 Bbl REUSE OTHER THAN ROAD SPREADING
2018 INFLECTION ENERGY (PA) LLC Produced Fluid 591.59 Bbl REUSE (AT WELL PAD)
2018 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 290.84 Bbl REUSE (AT WELL PAD)
2018 INFLECTION ENERGY (PA) LLC Produced Fluid 37.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 INFLECTION ENERGY (PA) LLC Synthetic Liner Materials 4.41 Tons
2019 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 2.57 Tons LANDFILL 100955
2019 INFLECTION ENERGY (PA) LLC Synthetic Liner Materials 1.26 Tons LANDFILL 100955
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 3.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 89.42 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 INFLECTION ENERGY (PA) LLC Synthetic Liner Materials 4.41 Tons BENEFICIAL REUSE ?PERMIT
2019 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 57.14 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 404.00 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 20.00 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 60.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 18.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2230430 Primary Facility 2013-12-18 Routine/Complete Inspection No Violations Noted
2266766 Primary Facility 2014-04-11 Drilling/Alteration No Violations Noted
2445329 Primary Facility 2016-01-26 Routine/Complete Inspection No Violations Noted
2475900 Primary Facility 2016-04-07 Routine/Complete Inspection No Violations Noted Inspection to evaluate the FWI de-watering plan submitted on 3/29/2016. Plan indicates water will be discharged to the well pad surface then flow off the pad down a rock lined ditch and discharge into a small vegetated area down the slope. Erosion is a concern at several locations on the site. Along the access road and cut slope, the steep slopes are eroding. The fill slope is not stabilized and it is evident topsoil has been lost at the surface. Water flowing off the pad surface and down the fill slope has caused erosion down the fill slope east of the rock-lined ditch. The site is not permanently stabilized and has rather extensive erosion. It appears that the proposed discharge area does not meet Pa Code § 78.60(5) because the discharge area is not an undisturbed, vegetated area capable of absorbing the water. Also, the erosion caused by water flowing off the well pad raises the concern that Pa Code § 78.53 will not be met during the discharge. The Department does not recommend that the discharge
2489719 Primary Facility 2016-06-02 Routine/Complete Inspection No Violations Noted Routine Inspection; 6/2/2016.

I entered the site off Tallman Hollow Road at 09:02 and began the inspection. At the time of the inspection, the Nature Boy East Yoder 1H (081-20920), Nature Boy East Unit 2H (081-20921), Nature Boy East Yoder 1V (081-21080), Nature Boy East Yoder 2V (081-21081), Nature Boy East Yoder 3V (081-21082), Nature Boy South Yoder 1H (081-21191), and Nature Boy South Yoder 2H (081-21192) were all in production.

A contractor was onsite scarifying, seeding, and stabilizing areas onsite which lacked vegetative cover or showed signs of erosion. The contractor was also re-grading the well pad so that water flows into the rock-lined ditch as designed and not over the fill slope. A sprinkler was set up on the north side of the well pad and had been watering a small section of the cut slope as indicated in the dewatering plan for the Fresh Water Impoundment. No Violations Noted.

2605770 Primary Facility 2017-06-20 Administrative/File Review Violation(s) Noted Administrative Inspection entered for the purpose of entering an Enforcement Record (NOV).

VIOLS closed (CRCTD) 3/14/2018 upon issuance of permit modification.

2643332 Primary Facility 2017-10-03 Routine/Complete Inspection No Violations Noted Arrived at 15:00. Weather: sunny,nice. 7 producing wells onsite. Routine inspection. No violations observed at this time.
2699738 Primary Facility 2018-03-01 Routine/Complete Inspection No Violations Noted Weather was 47° and cloudy with a slight wind at time of inspection. Well has a digital gauge attached to the tubing and the production casing. The gauge on the tubing read 326 psi and the gauge on the casing read 492 psi at time of inspection. There were three anulus vents plumbed to surface. Two of the annulus vents were labeled 20 and 13 and the third annulus vent was unlabeled. There was 0% combustible gas discovered on any of the vents at time of inspection. No violations were noted at time of inspection.
2776879 Primary Facility 2018-09-19 Routine/Complete Inspection No Violations Noted Seven wells staged for production phase. Seven each water separators within containment. Dump lines wrapped in insulating blanket. No leaks detected from production equipment. No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2605770 788471 2017-06-20 2018-03-14 OGA3211(F1) Administrative Well was intentionally drilled at a Surface Hole Location (SHL) other than the approved SHL on the well permit, resulting in the actual SHL being approximately 65 feet from the permitted SHL.
2605770 788472 2017-06-20 2018-03-14 78a12 Administrative The well was not drilled in accordance with the approved well permit. The actual SHL is approximately 65 feet from the permitted SHL. The maximum True Vertical Depth (TVD) reported in the deviation survey (8,147 feet) exceeds the permitted anticipated TVD (7,806 feet) by 341 feet. The Bottom Hole

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
788471 354437 NOV - Notice of Violation 2018-03-14
788472 354437 NOV - Notice of Violation 2018-03-14

For data sources see[8]

References