Well Details

Well ID: 37-005-30402
Loading map...
Operator Name: XTO ENERGY INC
First Permit Date: 2009-07-06
Last Permit Date: 2009-07-06
Spud Date: 2010-03-25
Unconventional: No
Horizontal: No
Violations: 1
Latitude: 40.85572
Longitude: -79.253336

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2013-0 6611.0 365.0 0.0 0.0 0.0 0.0
2012-0 7593.0 366.0 0.0 0.0 0.0 0.0
2011-0 6376.0 345.0 0.0 0.0 0.0 0.0
2010-0 3250.0 246.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2012-0 PRODUCED FLUID 76.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443 HART RESOURCE TECHNOLOGIES, INC. - CREEKSIDE CREEKSIDE PA
2010-0 PRODUCED FLUID 21.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAR000519462 ADVANCED WASTE SERVICES OF PA (NEW CASTLE) NEW CASTLE PA
2010-0 PRODUCED FLUID 3.0 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0026310 CLEARFIELD MUNICIPAL SEWAGE TREATMENT PLANT CLEARFIELD PA
2010-0 PRODUCED FLUID 2.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443 HART RESOURCE TECHNOLOGIES, INC. - CREEKSIDE CREEKSIDE PA
2010-0 PRODUCED FLUID 1.0 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0026034 JOHNSTOWN SEWAGE TREATMENT PLANT JOHNSTOWN PA
2010-0 PRODUCED FLUID 3.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273 PA BRINE TRT INC - JOSEPHINE PLT, INDIANA COUNTY JOSEPHINE PA
2010-0 PRODUCED FLUID 1.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0020346 PUNXSUTAWNEY BORO STP PUNXSUTAWNEY PA
2010-0 PRODUCED FLUID 1.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472 TUNNELTON LIQUIDS COMPANY SALTSBURG PA
2012-0 PRODUCED FLUID 76.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443 HART RESOURCE TECHNOLOGIES, INC. - CREEKSIDE CREEKSIDE PA
2013-0 PRODUCED FLUID 55.0 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273 FLUID RECOVERY SERVICE JOSEPHINE FACILITY JOSEPHINE PA

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
1874526 2010-04-02 Violation(s) Noted Drilling appeared to have been completed at the time of the inspection. Below grade pit located onsite and it had more than the required two feet of lined freeboard. Noted that the silt fence implemented as an erosion control below the site had been compromised. Specifically the fence had been undercut from the runoff flow below the well pad closest to where the access road enters the site. This resulted in an off-site transport of sediment.to an unnamed tributary of the North Branch of South Fork Pine Creek. Additionally the runoff/spring flow form the opposite side of the site had overtopped the silt fence and hay bales implemented as reinforcement resulting in an off-site transport of sediment to the same UNT. For this site a collection ditch and subsequent sediment trap would have been a more effective erosion control BMP. 584436
1877332 2010-04-14 No Violations Noted Drilling was completed at the time of the inspection. Noted that all of the issues noted and cited as violations in the 04/02/10 inspection had not been addressed.
1884108 2010-05-13 No Violations Noted Drilling appeared to have been completed at the time of the inspection. Met onsite with operator representative Tom Baun. Well was equipped for & in production. Brine tank located onsite and appeared to be in sound condition. Site had been regraded, however it had no as of yet been seeded and mulched. Observed that the erosion ditch that had been formed had been backfilled in, and the runoff flows had been eliminated. The silt fencing had been restablished and no accelerated erosion & sedimentation issues were observed in relation to the access road or well-site. Mr. Baun stated that the site would be seeded and mulched within the next few weeks. The operator should continue to monitor the site for accelerated erosion & sedimentation and to insure that the 70% uniform coverage criteria is achieved.

References