X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-117-21318"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-117-21318
 
| Well ID: 37-117-21318
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.8935, -77.410291 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.8935, -77.410292 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Tioga County, Pennsylvania|Tioga]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Chatham Township, Tioga County, Pennsylvania|Chatham Township]]
+
| State: Pennsylvania
 +
|-
 +
| County: [[Tioga_County,_Pennsylvania|Tioga]]
 +
|-
 +
| Municipality: [[Chatham Township,_Tioga_County,_Pennsylvania|Chatham Township]]
 
|-
 
|-
 
| Operator Name: [[SWEPI LP]]
 
| Operator Name: [[SWEPI LP]]
 
|-
 
|-
| Well Pad ID: [[149542|149542]]
+
| Well Pad ID: [[149542]]
 
|-
 
|-
 
| Farm/Lease Name: WATKINS V 820 5HS
 
| Farm/Lease Name: WATKINS V 820 5HS
 
|-
 
|-
| First Permit Date: 2011-09-28
+
| License Status: Active
|-
 
| Last Permit Date: 2011-09-28
 
|-
 
| Spud Date: 2011-10-04
 
 
|-
 
|-
| Unconventional: Yes
+
| Spud Date: 10/04/2011
 
|-
 
|-
| Horizontal: Yes
+
| Permit Date: 9/28/2011
 
|-
 
|-
| Well Status: ACTIVE
+
| Unconventional Well: Y
 
|-
 
|-
| Violations: 0
+
| Configuration: Horizontal Well
 
|-
 
|-
 
| Latitude: 41.8935
 
| Latitude: 41.8935
 
|-
 
|-
| Longitude: -77.410291
+
| Longitude: -77.410292
|-
 
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2011-0
+
| 2011
| style="text-align:right;" | 0.0
+
| style="text-align: right;" |
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" |  
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" |  
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" |  
 
|-
 
|-
 +
| 2012
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 159,347.24
 +
| style="text-align: right;" | 322
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-1
+
| 2013
| style="text-align:right;" | 64566.48
+
| [[SWEPI LP]]
| style="text-align:right;" | 138.0
+
| style="text-align: right;" | 158,817.61
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 300
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2014
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 88,374.07
 +
| style="text-align: right;" | 193
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-2
+
| 2015
| style="text-align:right;" | 94780.76
+
| [[SWEPI LP]]
| style="text-align:right;" | 184.0
+
| style="text-align: right;" | 54,784.76
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 41
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2016
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 105,414.67
 +
| style="text-align: right;" | 138
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2013-1
+
| 2017
| style="text-align:right;" | 79883.5
+
| [[SWEPI LP]]
| style="text-align:right;" | 152.0
+
| style="text-align: right;" | 89,199.48
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 130
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
|-
+
| style="text-align: right;" | 0
 
|-
 
|-
| 2013-2
+
| 2018
| style="text-align:right;" | 78934.11
+
| [[SWEPI LP]]
| style="text-align:right;" | 148.0
+
| style="text-align: right;" | 80,523.26
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 133
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
+
| 2019
| 2014-1
+
| [[SWEPI LP]]
| style="text-align:right;" | 56368.3
+
| style="text-align: right;" | 16,967.94
| style="text-align:right;" | 88.0
+
| style="text-align: right;" | 27
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
|-
 
|-
 
| 2014-2
 
| style="text-align:right;" | 32005.77
 
| style="text-align:right;" | 105.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-02
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-01
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-03
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =Oil and Gas Production Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Waste Type
!scope="col" | QUANTITY
+
!scope="col" | Quantity
!scope="col" | UNITS
+
!scope="col" | Disposal Method
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
 
| 2012-1
 
| 2012-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 8.0
+
| style="text-align: right;" | 8,656.17 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2012-2
 
| 2012-2
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 713.1
+
| style="text-align: right;" | 713.10 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR119
 
| WMGR119
| EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT
 
| WILLIAMSPORT
 
| PA
 
|-
 
 
|-
 
|-
 
| 2012-2
 
| 2012-2
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 386.9
+
| style="text-align: right;" | 386.90 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| WMGR0123
+
| WMGR123
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
|-
 
 
|-
 
|-
 
| 2012-2
 
| 2012-2
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 7.0
+
| style="text-align: right;" | 7,577.45 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2012-2
 
| 2012-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 55.95
+
| style="text-align: right;" | 55.95 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| WMGR0123
+
| WMGR123
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
|-
 
 
|-
 
|-
 
| 2012-2
 
| 2012-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 170.0
+
| style="text-align: right;" | 170.00 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 182.8
+
| style="text-align: right;" | 182.80 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR119
 
| WMGR119
| EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT
 
| WILLIAMSPORT
 
| PA
 
|-
 
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 460.91
+
| style="text-align: right;" | 460.91 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR0123
+
| WMGR123
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
|-
 
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 2.0
+
| style="text-align: right;" | 2,320.26 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2013-2
 
| 2013-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 1,543.34 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 549.69
+
| style="text-align: right;" | 549.69 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 301358
 
| 301358
| PHOENIX RESOURCES LANDFILL
 
| WELLSBORO
 
| PA
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| DRILLING FLUID WASTE
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 17.43
+
| style="text-align: right;" | 194.03 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR123NC010
+
| WMGR123
| HYDRO RECOVERY LP ANTRIM FACILITY
 
| WELLSBORO
 
| PA
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| DRILLING FLUID WASTE
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 194.03
+
| style="text-align: right;" | 17.43 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR0123
+
| WMGR123NC010
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| DRILLING FLUID WASTE
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 439.6
+
| style="text-align: right;" | 439.60 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 90.0
+
| style="text-align: right;" | 90.00 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 646.19
+
| style="text-align: right;" | 646.19 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 323.85
+
| style="text-align: right;" | 323.85 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 301358
 
| 301358
| PHOENIX RESOURCES LANDFILL
 
| WELLSBORO
 
| PA
 
|-
 
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| DRILLING FLUID WASTE
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 33.6
+
| style="text-align: right;" | 33.60 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
 
|  
 
|  
 
|-
 
|-
 +
| 2014-2
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 82.72 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 0.63
+
| style="text-align: right;" | 0.63 Bbl
| Bbl
 
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| 7-3115-00193
 
| 7-3115-00193
| ENVIRONMENTAL PRODUCTS & SERVICES OF VERMONT, INC.
 
| SYRACUSE
 
| NY
 
 
|-
 
|-
 +
| 2014-2
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 3,056.42 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 82.72
+
| style="text-align: right;" | 33.44 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR0123
+
| WMGR123
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
 
|-
 
|-
 +
| 2014-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 16.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 3.0
+
| style="text-align: right;" | 95.94 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
+
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 261.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC010
 +
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 3,459.20 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2015-2
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 0.20 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 239.85 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123
 
|-
 
|-
| 2014-2
+
| 2015-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 16.0
+
| style="text-align: right;" | 1,305.72 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123NC018
 
| WMGR123NC018
| EUREKA RESOURCES STANDING STONE TWP FACILITY
+
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 2,451.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016-1
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 2,404.60 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| PA
 
 
|-
 
|-
 +
| 2016-2
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 40.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC018
 
|-
 
|-
| 2014-2
+
| 2016-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 33.44
+
| style="text-align: right;" | 2,375.00 Bbl
| Bbl
+
| REUSE OTHER THAN ROAD SPREADING
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
|
| WMGR0123
+
|-
| HYDRO RECOVERY LP BLOSSBURG FACILITY
+
| 2016-2
| BLOSSBURG
+
| Waste Water Treatment Sludge (in Tons) RWC 804
| PA
+
| style="text-align: right;" | 4.94 Tons
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 
|-
 
|-
 +
| 2017-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 60.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 
|-
 
|-
| 2014-2
+
| 2017-01
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 95.94
+
| style="text-align: right;" | 260.00 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
+
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 264.20 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 +
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 40.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 +
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 480.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 256.80 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
|}
+
| 2017-04
For data sources see<ref>{{cite web
+
| Waste Water Treatment Sludge (in Tons) RWC 804
| title = Oil and Gas Historical Waste Report
+
| style="text-align: right;" | 2.26 Tons
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| RESIDUAL WASTE PROCESSING FACILITY
| date = 2015-05-26
+
| WMGR123
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
|-
| accessdate = 2015-05-26 }}</ref>
+
| 2017-05
== Inspection Data ==
+
| Produced Fluid (in Barrels) RWC 802
{| class="wikitable sortable" width="95%"
+
| style="text-align: right;" | 240.00 Bbl
!scope="col" | INSPECTION ID
+
| RESIDUAL WASTE PROCESSING FACILITY
!scope="col" | DATE
+
| WMGR123NC022
!scope="col" | DESCRIPTION
 
!scope="col" | COMMENT
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
| 2036096
+
| 2017-05
| 2012-01-18
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 40.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 20.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 80.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 240.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 58.31 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 2059645
+
| 2017-09
| 2012-04-12
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 20.00 Bbl
|  
+
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 +
|-
 +
| 2017-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 128.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 381.20 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-10
 +
| Waste Water Treatment Sludge (in Tons) RWC 804
 +
| style="text-align: right;" | 0.57 Tons
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 +
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 100.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 +
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 20.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 20.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 
|-
 
|-
| 2060157
+
| 2017-12
| 2012-04-16
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 200.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 200.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-01
 +
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811
 +
| style="text-align: right;" | 0.01 Tons
 +
| RESIDUAL WASTE TRANSFER FACILITY
 +
| 7-3115-00193
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 240.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 +
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 40.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 +
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 10.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 186.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 185.91 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2018-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 19.67 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 2202075
+
| 2018-06
| 2013-09-03
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 60.00 Bbl
| An inspection of the Watkins 820 site in Chatham Township, Tioga County was conducted on September 3, 2013.  The last inspection conducted on behalf of the operator was on August 12, 2013.  These inspection are required weekly or following a significant rain event.  The Watkins V 820 5H and Watkins V 820 5HS wells was drilled.  The Watkins 820 25H well's permit status is Active, but not yet drilled.  The status of the permits for the Watkins 820 2H, 3H, 4H, 5H and 6H wells are listed as "Operator Reported Not Drilled". No puddles exhibiting elevated conductivity were observed at this time.  The site was well vegetated and no erosion issues were noted.  No violations were cited during this inspection
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-06
 +
| Waste Water Treatment Sludge (in Tons) RWC 804
 +
| style="text-align: right;" | 1.13 Tons
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 +
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 100.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 60.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-08
 +
| Waste Water Treatment Sludge (in Tons) RWC 804
 +
| style="text-align: right;" | 2.26 Tons
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 
|-
 
|-
| 2206873
+
| 2018-09
| 2013-09-24
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 180.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 38.87 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 +
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 113.40 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2018-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 144.65 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2018-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 0.25 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 +
|-
 +
| 2018-11
 +
| Waste Water Treatment Sludge (in Tons) RWC 804
 +
| style="text-align: right;" | 2.83 Tons
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 +
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 77.50 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 +
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 100.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 350.25 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 387.25 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 19.50 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 40.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
| 2242849
+
| 2036096
| 2014-02-04
+
| Primary Facility
 +
| 01/18/2012
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2059645
 +
| Primary Facility
 +
| 04/12/2012
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2060157
 +
| Primary Facility
 +
| 04/16/2012
 +
| Follow-up Inspection
 +
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2202075
 +
| Primary Facility
 +
| 09/03/2013
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
| An inspection of the Watkins 820 site in Chatham Township, Tioga County was conducted on September 3, 2013.  The last inspection conducted on behalf of the operator was on August 12, 2013.  These inspection are required weekly or following a significant rain event.  The Watkins V 820 5H and Watkins V 820 5HS wells was drilled.  The Watkins 820 25H well's permit status is Active, but not yet drilled.  The status of the permits for the Watkins 820 2H, 3H, 4H, 5H and 6H wells are listed as "Operator Reported Not Drilled".  No puddles exhibiting elevated conductivity were observed at this time.  The site was well vegetated and no erosion issues were noted.  No violations were cited during this inspection
 +
|-
 +
| 2206873
 +
| Primary Facility
 +
| 09/24/2013
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
 +
| 2242849
 +
| Primary Facility
 +
| 02/04/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 
|-
 
|-
 
| 2252288
 
| 2252288
| 2014-02-12
+
| Primary Facility
 +
| 02/12/2014
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2258280
 +
| Primary Facility
 +
| 03/24/2014
 +
| Drilling/Alteration
 +
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2313020
 +
| Primary Facility
 +
| 10/15/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2316973
 +
| Primary Facility
 +
| 10/29/2014
 +
| Complaint Inspection
 +
| No Violations Noted
 +
| The Department inspected the Watkins 820, permit# ESX11-117-0019, in Chatham Twp., Tioga Co. on 10/29/14 @ 1110 hours in response to a water supply complaint. The weather was 52 degrees and overcast. Present onsite were Jonathan Pennings, DEP WQS and Mike Parker, OSR Swepi LP. No oil and gas activity was taking place onsite during the inspection. A hydro excavator was onsite looking for utility lines buried beneath the pad surface. Mr. Parker stated staged fracking had been completed on the Watkins 820 23H and 25H wells, both Utica wells, between 9/28/14 and 10/18/14. They were hoping to frack the Watkins 21H in the next few days, also a Utica well. He also stated the two Marcellus wells, the Watkins 5H and 5HS were “shut in”. The Watkins 2H through 6H wells were listed as “operator reported not drilled”.
 +
|-
 +
| 2328182
 +
| Primary Facility
 +
| 12/08/2014
 +
| Incident- Response to Accident or Event
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
 +
| 2484928
 +
| Primary Facility
 +
| 2016-05-17
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The SWEPI, LP Watkins 820 site in Chatham Twp., Tioga Co. was inspected by the Department @ 1300 hours on 5/17/16. The weather was 59°, cloudy, winds WSW 8 mph.  A valid site ID sign was observed at the entrace to the access road. The PPC Plan, onsite inspection log, well permits and a copy of the E&S plan were observed in the mailbox. The site was last inspected by company personnel on 5/11/2016 with “no change” noted in the comments.
 +
 +
During the onsite inspection, fluid was osberved in the the containment surrounding the 500-barrel- tanks. The fluid was screened for conductivity using an Oakton Multi-Parameter PCSTestr 35. The field conductivity was measured at 2.98 mS/cm. A puddle was observed on the pad surface adjacent to the tank containment. This puddle measured 7.34 mS/cm. An additional puddle (it was not clear in the field if the two were connected) was also screened and the field conductivity measured 6.77 mS/cm. A sampled of the puddle measuring 7.34 mS/cm was obtained and submitted to the lab in
 +
|-
 +
| 2494020
 +
| Primary Facility
 +
| 2016-05-17
 +
| Administrative/File Review
 +
| No Violations Noted
 +
| An administrative report was generated for the SWEPI LP – Watkins 820 site in Chatham Twp., Tioga Co. (ESX11-117-0019). Sample results collected 5/17/2016 indicate the presence of a pollution substance on the ground outside of containment. This constitutes a violation of 25 Pa. Code 78.45 (relating to Oil and Gas Wells) against the Watkins 820 23H well, permit #117-21676, based on the laboratory sample results. In accordance with S 78.54 the well operator shall control and dispose of fluids, residual waste and rill cuttings, including tophole water, brines, drilling fluids, drilling muds, stimulation fluids, well servicing fluids, oil, production fluids and drill cuttings in a manner that prevents pollution of the waters of this Commonwealth and in accordance with §§ 78.55-78.58 and 78.60-78.63 and with the statutes under which this chapter is promulgated.
 +
 +
No violations were cited against eh ESCGP or remaining well permit numbers.
 
|-
 
|-
| 2313020
+
| 2494151
| 2014-10-15
+
| Primary Facility
 +
| 2016-06-08
 +
| Follow-up Inspection
 +
| No Violations Noted
 +
| The Department of Environmental Protection (DEP) conducted an onsite Follow-up inspection at the SWEPI LP – Watkins 820 well site in Chatham Twp., Tioga Co. (ESX11-117-0019) on 6/8/2016 @ 1010 hours. The weather was 50° and raining. The DEP was notified SWEPI would be conducting additional remediation efforts to remove soil with an elevated conductivity related to an unknown/unreported release on 6/8/2016.
 +
 
 +
Background: A violation of 25 PA. Code 78.54 was issued 5/17/2016 based on sample results, collected from a puddle outside containment by the DEP, showing elevated chlorides and conductivity
 +
.
 +
On 5/18/2016 SWEPI investigated the DEP’s findings. Mr. Bernethy stated he found areas of elevated conductivity and sent a vacuum truck to the site to clean up the puddles. SWEPI was investigating the secondary containment and the reason no spill was reported.
 +
 
 +
As of today’s inspection, SWEPI has removed material from the affected area. Approximately ½ a roll-off waste container of material was removed. Please pr
 +
|-
 +
| 2523510
 +
| Primary Facility
 +
| 2016-09-22
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The Department of Environmental Protection (DEP) inspected the Wakins 820 site in Chatham Twp., Tioga Co. on 9/22/2016 @1245 hours. The valid site ID sign is located at the entrance to the access road. The site was last inspected by company personnel on 9/10/2016 with “erosion on lease road. Erosion on back side of pad by frac tanks and gravel.” recorded in the comments section.
 +
No puddles were observed on the pad surface. Standing water was observed in the secondary containment surrounding the roll off tanks. The field conductivity was measured at 800µS/cm.  Erosion was observed on the access road as noted in the E&S log. An area on the back side of the tank pad appears to have a mound of sawdust like material. Shredded ECB matting is visible on top of it. No vegetation was observed, but the pile does not appear to be eroding. All E&S controls appear to be functional. No violations are noted at this time. I departed the site @ 1330 hours.
 +
This inspection report references the following well permits –
 +
117-
 +
|-
 +
| 2548027
 +
| Primary Facility
 +
| 2016-12-28
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2557551
 +
| Primary Facility
 +
| 2017-02-01
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The Department of Environmental Protection (DEP) inspected the SWEPI LP Watkins 820 well site in Chatham Twp., Tioga Co. on 2/1/2017. The weather was partly sunny, 30°, fresh snow accumulation of ~3". No activity was observed onsite. No puddles observed on the pad surface. No vegetation was observed, but the site appears to be stable. Erosion and sediment controls were not observed due to snow cover, but no issues were detected. No violations were issued during this inspection. Please contact me with any questions.
 +
|-
 +
| 2633462
 +
| Primary Facility
 +
| 2017-09-06
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
| EC readings with Oakton PCSTestr 35 (mS/cm):  containment--0.27, pad--0.22.
 +
|-
 +
| 2722369
 +
| Primary Facility
 +
| 2018-04-24
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The Department of Environmental Protection inspected the Watkins 820 Well Site located in Chatham Twp, Tioga Co. on 4/25/2018 @ 1415 hours. The weather was 60 degrees and partly sunny . No activity was observed onsite.
 +
 +
There are five producing wells onsite. Production fluids are contained in Highland tanks. Water was observed in the secondary containment surrounding the Rolloff tank. The water exhibited conductivity within normal range. Two puddles on the pad service were also screened for conductivity and found to be within normal range.
 +
 +
No violations were noted. I departed the site at 1315 hours.
 +
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 12/27/2011
 +
| 12/27/2011
 +
| style="text-align: right;" | 3808.00
 +
| style="text-align: right;" | 4,523,568.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="20"| 1
 +
| rowspan="1"| FR-900
 +
| rowspan="1"| Nalco
 +
| rowspan="1"| Scale Inhibitor
 +
| not classified as hazardous
 
|  
 
|  
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.10
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Plexgel Breaker
 +
| rowspan="1"| Chemplex
 +
| rowspan="1"| Enzyme Breaker
 +
| not classified as hazardous
 
|  
 
|  
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00019000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Hydrochloric Acid
 +
| rowspan="2"| Reagent Chemical & Research
 +
| rowspan="2"|
 +
| Water
 
|  
 
|  
 +
| style="text-align: right;" | 85.00
 +
| style="text-align: right;" | 0.31
 +
| style="text-align: right;" |
 
|-
 
|-
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.05
 +
| style="text-align: right;" |
 
|-
 
|-
| 2316973
+
|- valign="top"
| 2014-10-29
+
| rowspan="1"| Water
| No Violations Noted
+
| rowspan="1"| Shell
| The Department inspected the Watkins 820
+
| rowspan="1"|
 +
|  
 
|  
 
|  
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 93.44
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand
 +
| rowspan="1"| Badger Mining Co.
 +
| rowspan="1"| Proppant
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 99.90
 +
| style="text-align: right;" | 6.00
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| MSI-7
 +
| rowspan="1"| National Petrochemical
 +
| rowspan="1"| Scale Inhibitor
 +
| Hydorgen Chloride
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| FE-4
 +
| rowspan="2"| Univar
 +
| rowspan="2"| Iron Control/Reducer
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 50.00
 +
| style="text-align: right;" | 0.00056000
 +
| style="text-align: right;" |
 +
|-
 +
| Citric acid
 +
| 77-92-9
 +
| style="text-align: right;" | 50.00
 +
| style="text-align: right;" | 0.00056000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| PetroFlow
 +
| rowspan="1"| Bio-Cide International
 +
| rowspan="1"| Biocide
 +
| Sodium chlorite
 +
| 7758-19-2
 +
| style="text-align: right;" | 8.35
 +
| style="text-align: right;" | 0.00413000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="9"| I-22
 +
| rowspan="9"| Nalco
 +
| rowspan="9"| Acid Corrosion Inhibitor
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" |
 +
|-
 +
| Aromatic aldehyde
 
|  
 
|  
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00011000
 +
| style="text-align: right;" |
 
|-
 
|-
 +
| Formic acid
 +
| 64-18-6
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00022000
 +
| style="text-align: right;" |
 +
|-
 +
| Quaternary ammonium compounds
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" |
 
|-
 
|-
| 2328182
+
| Haloalkyl heteropolycycle salt
| 2014-12-08
 
| No Violations Noted
 
 
|  
 
|  
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00011000
 +
| style="text-align: right;" |
 +
|-
 +
| Benzyl chloride
 +
| 100-44-7
 +
| style="text-align: right;" | 1.00
 +
| style="text-align: right;" | 0.00001000
 +
| style="text-align: right;" |
 +
|-
 +
| Oxyalkylated Fatty Acid
 
|  
 
|  
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00011000
 +
| style="text-align: right;" |
 +
|-
 +
| Organic sulfur compounds
 
|  
 
|  
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" |
 +
|-
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Plex 907
 +
| rowspan="1"| Chemplex
 +
| rowspan="1"| Gelling Agent/Thickener
 +
| vegetable gums
 
|  
 
|  
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
==References==
== References ==
+
<references/>
{{reflist}}
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 12:28, 15 July 2019

Well Details

Well ID: 37-117-21318
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Chatham Township
Operator Name: SWEPI LP
Well Pad ID: 149542
Farm/Lease Name: WATKINS V 820 5HS
License Status: Active
Spud Date: 10/04/2011
Permit Date: 9/28/2011
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.8935
Longitude: -77.410292

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 0.00 0.00 0.00
2012 SWEPI LP 159,347.24 322 0.00 0 0.00 0
2013 SWEPI LP 158,817.61 300 0.00 0 0.00 0
2014 SWEPI LP 88,374.07 193 0.00 0 0.00 0
2015 SWEPI LP 54,784.76 41 0.00 0 0.00 0
2016 SWEPI LP 105,414.67 138 0.00 0 0.00 0
2017 SWEPI LP 89,199.48 130 0.00 0 0.00 0
2018 SWEPI LP 80,523.26 133 0.00 0 0.00 0
2019 SWEPI LP 16,967.94 27 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-1 Produced Fluid (in Barrels) 8,656.17 Bbl REUSE OTHER THAN ROAD SPREADING
2012-2 Fracing Fluid Waste (in Barrels) 713.10 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012-2 Fracing Fluid Waste (in Barrels) 386.90 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012-2 Fracing Fluid Waste (in Barrels) 7,577.45 Bbl REUSE OTHER THAN ROAD SPREADING
2012-2 Produced Fluid (in Barrels) 55.95 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012-2 Produced Fluid (in Barrels) 170.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Produced Fluid (in Barrels) 182.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013-1 Produced Fluid (in Barrels) 460.91 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013-1 Produced Fluid (in Barrels) 2,320.26 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Produced Fluid (in Barrels) 1,543.34 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Drill Cuttings (in Tons) 549.69 Tons LANDFILL 301358
2014-1 Drilling Fluid Waste (in Barrels) 194.03 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-1 Drilling Fluid Waste (in Barrels) 17.43 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014-1 Drilling Fluid Waste (in Barrels) 439.60 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Fracing Fluid Waste (in Barrels) 90.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 646.19 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Drill Cuttings (in Tons) 323.85 Tons LANDFILL 301358
2014-2 Drilling Fluid Waste (in Barrels) 33.60 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Fracing Fluid Waste (in Barrels) 82.72 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-2 Fracing Fluid Waste (in Barrels) 0.63 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2014-2 Fracing Fluid Waste (in Barrels) 3,056.42 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 33.44 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-2 Produced Fluid (in Barrels) 16.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014-2 Produced Fluid (in Barrels) 95.94 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 261.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-1 Produced Fluid (in Barrels) 3,459.20 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Fracing Fluid Waste (in Barrels) 0.20 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 239.85 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-2 Produced Fluid (in Barrels) 1,305.72 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015-2 Produced Fluid (in Barrels) 2,451.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 2,404.60 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Produced Fluid (in Barrels) RWC 802 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016-2 Produced Fluid (in Barrels) RWC 802 2,375.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Waste Water Treatment Sludge (in Tons) RWC 804 4.94 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-01 Produced Fluid (in Barrels) RWC 802 60.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-01 Produced Fluid (in Barrels) RWC 802 260.00 Bbl REUSE (AT WELL PAD)
2017-02 Produced Fluid (in Barrels) RWC 802 264.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-03 Produced Fluid (in Barrels) RWC 802 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-03 Produced Fluid (in Barrels) RWC 802 480.00 Bbl REUSE (AT WELL PAD)
2017-04 Produced Fluid (in Barrels) RWC 802 256.80 Bbl REUSE (AT WELL PAD)
2017-04 Waste Water Treatment Sludge (in Tons) RWC 804 2.26 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-05 Produced Fluid (in Barrels) RWC 802 240.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-05 Produced Fluid (in Barrels) RWC 802 40.00 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 20.00 Bbl REUSE (AT WELL PAD)
2017-07 Produced Fluid (in Barrels) RWC 802 80.00 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 240.00 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 58.31 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-09 Produced Fluid (in Barrels) RWC 802 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-09 Produced Fluid (in Barrels) RWC 802 128.00 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 381.20 Bbl REUSE (AT WELL PAD)
2017-10 Waste Water Treatment Sludge (in Tons) RWC 804 0.57 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-11 Produced Fluid (in Barrels) RWC 802 100.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-11 Produced Fluid (in Barrels) RWC 802 20.00 Bbl REUSE (AT WELL PAD)
2017-12 Produced Fluid (in Barrels) RWC 802 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-12 Produced Fluid (in Barrels) RWC 802 200.00 Bbl REUSE (AT WELL PAD)
2018-01 Produced Fluid (in Barrels) RWC 802 200.00 Bbl REUSE (AT WELL PAD)
2018-01 Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 0.01 Tons RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2018-02 Produced Fluid (in Barrels) RWC 802 240.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-03 Produced Fluid (in Barrels) RWC 802 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-03 Produced Fluid (in Barrels) RWC 802 10.00 Bbl REUSE (AT WELL PAD)
2018-04 Produced Fluid (in Barrels) RWC 802 186.00 Bbl REUSE (AT WELL PAD)
2018-05 Produced Fluid (in Barrels) RWC 802 185.91 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-06 Produced Fluid (in Barrels) RWC 802 19.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-06 Produced Fluid (in Barrels) RWC 802 60.00 Bbl REUSE (AT WELL PAD)
2018-06 Waste Water Treatment Sludge (in Tons) RWC 804 1.13 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-07 Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE (AT WELL PAD)
2018-08 Produced Fluid (in Barrels) RWC 802 60.00 Bbl REUSE (AT WELL PAD)
2018-08 Waste Water Treatment Sludge (in Tons) RWC 804 2.26 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-09 Produced Fluid (in Barrels) RWC 802 180.00 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 38.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-10 Produced Fluid (in Barrels) RWC 802 113.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-11 Produced Fluid (in Barrels) RWC 802 144.65 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-11 Produced Fluid (in Barrels) RWC 802 0.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-11 Waste Water Treatment Sludge (in Tons) RWC 804 2.83 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-12 Produced Fluid (in Barrels) RWC 802 77.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-12 Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE (AT WELL PAD)
2019-01 Produced Fluid (in Barrels) RWC 802 350.25 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 387.25 Bbl REUSE (AT WELL PAD)
2019-03 Produced Fluid (in Barrels) RWC 802 19.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019-03 Produced Fluid (in Barrels) RWC 802 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2036096 Primary Facility 01/18/2012 Routine/Complete Inspection No Violations Noted
2059645 Primary Facility 04/12/2012 Routine/Complete Inspection No Violations Noted
2060157 Primary Facility 04/16/2012 Follow-up Inspection No Violations Noted
2202075 Primary Facility 09/03/2013 Routine/Partial Inspection No Violations Noted An inspection of the Watkins 820 site in Chatham Township, Tioga County was conducted on September 3, 2013. The last inspection conducted on behalf of the operator was on August 12, 2013. These inspection are required weekly or following a significant rain event. The Watkins V 820 5H and Watkins V 820 5HS wells was drilled. The Watkins 820 25H well's permit status is Active, but not yet drilled. The status of the permits for the Watkins 820 2H, 3H, 4H, 5H and 6H wells are listed as "Operator Reported Not Drilled". No puddles exhibiting elevated conductivity were observed at this time. The site was well vegetated and no erosion issues were noted. No violations were cited during this inspection
2206873 Primary Facility 09/24/2013 Routine/Complete Inspection No Violations Noted
2242849 Primary Facility 02/04/2014 Routine/Complete Inspection No Violations Noted
2252288 Primary Facility 02/12/2014 Routine/Complete Inspection No Violations Noted
2258280 Primary Facility 03/24/2014 Drilling/Alteration No Violations Noted
2313020 Primary Facility 10/15/2014 Routine/Complete Inspection No Violations Noted
2316973 Primary Facility 10/29/2014 Complaint Inspection No Violations Noted The Department inspected the Watkins 820, permit# ESX11-117-0019, in Chatham Twp., Tioga Co. on 10/29/14 @ 1110 hours in response to a water supply complaint. The weather was 52 degrees and overcast. Present onsite were Jonathan Pennings, DEP WQS and Mike Parker, OSR Swepi LP. No oil and gas activity was taking place onsite during the inspection. A hydro excavator was onsite looking for utility lines buried beneath the pad surface. Mr. Parker stated staged fracking had been completed on the Watkins 820 23H and 25H wells, both Utica wells, between 9/28/14 and 10/18/14. They were hoping to frack the Watkins 21H in the next few days, also a Utica well. He also stated the two Marcellus wells, the Watkins 5H and 5HS were “shut in”. The Watkins 2H through 6H wells were listed as “operator reported not drilled”.
2328182 Primary Facility 12/08/2014 Incident- Response to Accident or Event No Violations Noted
2484928 Primary Facility 2016-05-17 Routine/Complete Inspection No Violations Noted The SWEPI, LP Watkins 820 site in Chatham Twp., Tioga Co. was inspected by the Department @ 1300 hours on 5/17/16. The weather was 59°, cloudy, winds WSW 8 mph. A valid site ID sign was observed at the entrace to the access road. The PPC Plan, onsite inspection log, well permits and a copy of the E&S plan were observed in the mailbox. The site was last inspected by company personnel on 5/11/2016 with “no change” noted in the comments.

During the onsite inspection, fluid was osberved in the the containment surrounding the 500-barrel- tanks. The fluid was screened for conductivity using an Oakton Multi-Parameter PCSTestr 35. The field conductivity was measured at 2.98 mS/cm. A puddle was observed on the pad surface adjacent to the tank containment. This puddle measured 7.34 mS/cm. An additional puddle (it was not clear in the field if the two were connected) was also screened and the field conductivity measured 6.77 mS/cm. A sampled of the puddle measuring 7.34 mS/cm was obtained and submitted to the lab in

2494020 Primary Facility 2016-05-17 Administrative/File Review No Violations Noted An administrative report was generated for the SWEPI LP – Watkins 820 site in Chatham Twp., Tioga Co. (ESX11-117-0019). Sample results collected 5/17/2016 indicate the presence of a pollution substance on the ground outside of containment. This constitutes a violation of 25 Pa. Code 78.45 (relating to Oil and Gas Wells) against the Watkins 820 23H well, permit #117-21676, based on the laboratory sample results. In accordance with S 78.54 the well operator shall control and dispose of fluids, residual waste and rill cuttings, including tophole water, brines, drilling fluids, drilling muds, stimulation fluids, well servicing fluids, oil, production fluids and drill cuttings in a manner that prevents pollution of the waters of this Commonwealth and in accordance with §§ 78.55-78.58 and 78.60-78.63 and with the statutes under which this chapter is promulgated.

No violations were cited against eh ESCGP or remaining well permit numbers.

2494151 Primary Facility 2016-06-08 Follow-up Inspection No Violations Noted The Department of Environmental Protection (DEP) conducted an onsite Follow-up inspection at the SWEPI LP – Watkins 820 well site in Chatham Twp., Tioga Co. (ESX11-117-0019) on 6/8/2016 @ 1010 hours. The weather was 50° and raining. The DEP was notified SWEPI would be conducting additional remediation efforts to remove soil with an elevated conductivity related to an unknown/unreported release on 6/8/2016.

Background: A violation of 25 PA. Code 78.54 was issued 5/17/2016 based on sample results, collected from a puddle outside containment by the DEP, showing elevated chlorides and conductivity . On 5/18/2016 SWEPI investigated the DEP’s findings. Mr. Bernethy stated he found areas of elevated conductivity and sent a vacuum truck to the site to clean up the puddles. SWEPI was investigating the secondary containment and the reason no spill was reported.

As of today’s inspection, SWEPI has removed material from the affected area. Approximately ½ a roll-off waste container of material was removed. Please pr
2523510 Primary Facility 2016-09-22 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the Wakins 820 site in Chatham Twp., Tioga Co. on 9/22/2016 @1245 hours. The valid site ID sign is located at the entrance to the access road. The site was last inspected by company personnel on 9/10/2016 with “erosion on lease road. Erosion on back side of pad by frac tanks and gravel.” recorded in the comments section.

No puddles were observed on the pad surface. Standing water was observed in the secondary containment surrounding the roll off tanks. The field conductivity was measured at 800µS/cm. Erosion was observed on the access road as noted in the E&S log. An area on the back side of the tank pad appears to have a mound of sawdust like material. Shredded ECB matting is visible on top of it. No vegetation was observed, but the pile does not appear to be eroding. All E&S controls appear to be functional. No violations are noted at this time. I departed the site @ 1330 hours. This inspection report references the following well permits – 117-

2548027 Primary Facility 2016-12-28 Routine/Complete Inspection No Violations Noted
2557551 Primary Facility 2017-02-01 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the SWEPI LP Watkins 820 well site in Chatham Twp., Tioga Co. on 2/1/2017. The weather was partly sunny, 30°, fresh snow accumulation of ~3". No activity was observed onsite. No puddles observed on the pad surface. No vegetation was observed, but the site appears to be stable. Erosion and sediment controls were not observed due to snow cover, but no issues were detected. No violations were issued during this inspection. Please contact me with any questions.
2633462 Primary Facility 2017-09-06 Routine/Partial Inspection No Violations Noted EC readings with Oakton PCSTestr 35 (mS/cm): containment--0.27, pad--0.22.
2722369 Primary Facility 2018-04-24 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection inspected the Watkins 820 Well Site located in Chatham Twp, Tioga Co. on 4/25/2018 @ 1415 hours. The weather was 60 degrees and partly sunny . No activity was observed onsite.

There are five producing wells onsite. Production fluids are contained in Highland tanks. Water was observed in the secondary containment surrounding the Rolloff tank. The water exhibited conductivity within normal range. Two puddles on the pad service were also screened for conductivity and found to be within normal range.

No violations were noted. I departed the site at 1315 hours.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 12/27/2011 12/27/2011 3808.00 4,523,568.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-900 Nalco Scale Inhibitor not classified as hazardous 100.00 0.10
Plexgel Breaker Chemplex Enzyme Breaker not classified as hazardous 100.00 0.00019000
Hydrochloric Acid Reagent Chemical & Research Water 85.00 0.31
Hydrochloric acid 7647-01-0 15.00 0.05
Water Shell 100.00 93.44
Sand Badger Mining Co. Proppant Quartz 14808-60-7 99.90 6.00
MSI-7 National Petrochemical Scale Inhibitor Hydorgen Chloride 0.01
FE-4 Univar Iron Control/Reducer Water 7732-18-5 50.00 0.00056000
Citric acid 77-92-9 50.00 0.00056000
PetroFlow Bio-Cide International Biocide Sodium chlorite 7758-19-2 8.35 0.00413000
I-22 Nalco Acid Corrosion Inhibitor Methanol 67-56-1 5.00 0.00002000
Aromatic aldehyde 30.00 0.00011000
Formic acid 64-18-6 60.00 0.00022000
Quaternary ammonium compounds 5.00 0.00002000
Haloalkyl heteropolycycle salt 30.00 0.00011000
Benzyl chloride 100-44-7 1.00 0.00001000
Oxyalkylated Fatty Acid 30.00 0.00011000
Organic sulfur compounds 5.00 0.00002000
Isopropanol 67-63-0 5.00 0.00002000
Plex 907 Chemplex Gelling Agent/Thickener vegetable gums 100.00 0.01

For data sources see[7]