X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-007-20412"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-007-20412
 
| Well ID: 37-007-20412
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.760197, -80.167083 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 40.760197, -80.167083 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Beaver County, Pennsylvania|Beaver]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[New Sewickley Township, Beaver County, Pennsylvania|New Sewickley Township]]
+
| State: Pennsylvania
 +
|-
 +
| County: [[Beaver_County,_Pennsylvania|Beaver]]
 +
|-
 +
| Municipality: [[New Sewickley Township,_Beaver_County,_Pennsylvania|New Sewickley Township]]
 
|-
 
|-
 
| Operator Name: [[PENNENERGY RESOURCES LLC]]
 
| Operator Name: [[PENNENERGY RESOURCES LLC]]
 
|-
 
|-
| Well Pad ID: [[150486|150486]]
+
| Well Pad ID: [[150486]]
 
|-
 
|-
 
| Farm/Lease Name: B3 PER B3-2H
 
| Farm/Lease Name: B3 PER B3-2H
 
|-
 
|-
| First Permit Date: 2013-11-12
+
| License Status: Active
 
|-
 
|-
| Last Permit Date: 2013-11-12
+
| Spud Date: 04/10/2014
 
|-
 
|-
| Spud Date: 2014-04-10
+
| Permit Date: 11/12/2013
 
|-
 
|-
| Unconventional: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Configuration: Horizontal
+
| Configuration: Horizontal Well
|-
 
| Well Status: ACTIVE
 
|-
 
| Violations: 0
 
 
|-
 
|-
 
| Latitude: 40.760197
 
| Latitude: 40.760197
 
|-
 
|-
 
| Longitude: -80.167083
 
| Longitude: -80.167083
|-
 
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
|-
+
!scope="col" | Water Production Days
| 2014-1
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2014-2
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-02
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-01
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-03
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 16-Jan
 
| style="text-align:right;" | 85681.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 366.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 15-Aug
 
| style="text-align:right;" | 121538.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 756.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 15DECU
 
| style="text-align:right;" | 96287.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 392.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 15JULU
 
| style="text-align:right;" | 12309.0
 
| style="text-align:right;" | 5.0
 
| style="text-align:right;" | 112.0
 
| style="text-align:right;" | 5.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 15MAYU
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 15OCTU
 
| style="text-align:right;" | 33607.0
 
| style="text-align:right;" | 8.0
 
| style="text-align:right;" | 528.0
 
| style="text-align:right;" | 8.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 15OCTU
 
| style="text-align:right;" | 33607.0
 
| style="text-align:right;" | 8.0
 
| style="text-align:right;" | 528.0
 
| style="text-align:right;" | 8.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 15SEPU
 
| style="text-align:right;" | 799.0
 
| style="text-align:right;" | 1.0
 
| style="text-align:right;" | 5.0
 
| style="text-align:right;" | 1.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 16APRU
 
| style="text-align:right;" | 72699.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 346.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 16FEBU
 
| style="text-align:right;" | 75767.0
 
| style="text-align:right;" | 29.0
 
| style="text-align:right;" | 387.0
 
| style="text-align:right;" | 29.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 16MARU
 
| style="text-align:right;" | 78284.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 415.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2014-1
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2014-2
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-04
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-02
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-01
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-06
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-03
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-05
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-08
 
| style="text-align:right;" | 121538.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 756.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-12
 
| style="text-align:right;" | 96287.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 392.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-07
 
| style="text-align:right;" | 12309.0
 
| style="text-align:right;" | 5.0
 
| style="text-align:right;" | 112.0
 
| style="text-align:right;" | 5.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-11
 
| style="text-align:right;" | 112715.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 720.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-10
 
| style="text-align:right;" | 33607.0
 
| style="text-align:right;" | 8.0
 
| style="text-align:right;" | 528.0
 
| style="text-align:right;" | 8.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-09
 
| style="text-align:right;" | 799.0
 
| style="text-align:right;" | 1.0
 
| style="text-align:right;" | 5.0
 
| style="text-align:right;" | 1.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-04
 
| style="text-align:right;" | 72699.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 346.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-08
 
| style="text-align:right;" | 68733.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 273.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-12
 
| style="text-align:right;" | 65077.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 302.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-02
 
| style="text-align:right;" | 75767.0
 
| style="text-align:right;" | 29.0
 
| style="text-align:right;" | 387.0
 
| style="text-align:right;" | 29.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-01
 
| style="text-align:right;" | 85681.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 366.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-07
 
| style="text-align:right;" | 69580.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 263.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-06
 
| style="text-align:right;" | 69854.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 352.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-03
 
| style="text-align:right;" | 78284.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 415.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-05
 
| style="text-align:right;" | 74096.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 422.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-11
 
| style="text-align:right;" | 61774.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 360.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-10
 
| style="text-align:right;" | 65822.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 232.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2016-09
 
| style="text-align:right;" | 65030.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 252.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-12
 
| style="text-align:right;" | 48814.0
 
| style="text-align:right;" | 27.0
 
| style="text-align:right;" | 222.0
 
| style="text-align:right;" | 27.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-02
 
| style="text-align:right;" | 54533.0
 
| style="text-align:right;" | 28.0
 
| style="text-align:right;" | 277.0
 
| style="text-align:right;" | 28.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-07
 
| style="text-align:right;" | 30318.0
 
| style="text-align:right;" | 15.0
 
| style="text-align:right;" | 111.0
 
| style="text-align:right;" | 15.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-06
 
| style="text-align:right;" | 55049.0
 
| style="text-align:right;" | 29.0
 
| style="text-align:right;" | 197.0
 
| style="text-align:right;" | 29.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-10
 
| style="text-align:right;" | 33562.0
 
| style="text-align:right;" | 17.0
 
| style="text-align:right;" | 168.0
 
| style="text-align:right;" | 17.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-09
 
| style="text-align:right;" | 50687.0
 
| style="text-align:right;" | 28.0
 
| style="text-align:right;" | 240.0
 
| style="text-align:right;" | 28.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-04
 
| style="text-align:right;" | 58116.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 223.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-05
 
| style="text-align:right;" | 58524.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 246.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-11
 
| style="text-align:right;" | 54592.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 260.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-08
 
| style="text-align:right;" | 60067.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 205.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-01
 
| style="text-align:right;" | 61913.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 288.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2017-03
 
| style="text-align:right;" | 59871.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 289.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-04
 
| style="text-align:right;" | 46368.0
 
| style="text-align:right;" | 27.0
 
| style="text-align:right;" | 253.0
 
| style="text-align:right;" | 27.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-02
 
| style="text-align:right;" | 46458.0
 
| style="text-align:right;" | 28.0
 
| style="text-align:right;" | 267.0
 
| style="text-align:right;" | 28.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-11
 
| style="text-align:right;" | 46228.0
 
| style="text-align:right;" | 29.0
 
| style="text-align:right;" | 155.0
 
| style="text-align:right;" | 29.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-10
 
| style="text-align:right;" | 38711.0
 
| style="text-align:right;" | 22.0
 
| style="text-align:right;" | 125.0
 
| style="text-align:right;" | 22.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-09
 
| style="text-align:right;" | 43601.0
 
| style="text-align:right;" | 28.0
 
| style="text-align:right;" | 138.0
 
| style="text-align:right;" | 28.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-01
 
| style="text-align:right;" | 51079.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 257.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-06
 
| style="text-align:right;" | 49627.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 168.0
 
| style="text-align:right;" | 30.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-08
 
| style="text-align:right;" | 49125.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 137.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-12
 
| style="text-align:right;" | 47696.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 184.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-07
 
| style="text-align:right;" | 50298.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 149.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-03
 
| style="text-align:right;" | 52292.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 278.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2018-05
 
| style="text-align:right;" | 52192.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 209.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2019-02
 
| style="text-align:right;" | 40799.0
 
| style="text-align:right;" | 23.0
 
| style="text-align:right;" | 159.0
 
| style="text-align:right;" | 23.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2019-01
 
| style="text-align:right;" | 40474.0
 
| style="text-align:right;" | 24.0
 
| style="text-align:right;" | 169.0
 
| style="text-align:right;" | 24.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2019-03
 
| style="text-align:right;" | 46510.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 197.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title = Oil and Gas Historical Production Report
 
| publisher = [[Pennsylvania Department of Environmental Protection]]
 
| date = 2015-05-26
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
 
| accessdate = 2015-05-27 }}</ref>
 
== Inspection Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | INSPECTION ID
 
!scope="col" | DATE
 
!scope="col" | DESCRIPTION
 
!scope="col" | COMMENT
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION COMMENT
 
 
|-
 
|-
| 2307359
+
| 2014
| 2014-09-11
+
| [[PENNENERGY RESOURCES LLC]]
| No Violations Noted
+
| style="text-align: right;" | 0.00
| PATTERSON 259 DRILLING HORIZONTAL LEG AT 10
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 0.00
|  
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2015
 +
| [[PENNENERGY RESOURCES LLC]]
 +
| style="text-align: right;" | 377,255.00
 +
| style="text-align: right;" | 105
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 2,513.00
 +
| style="text-align: right;" | 105
 
|-
 
|-
| 2350395
+
| 2016
| 2015-01-20
+
| [[PENNENERGY RESOURCES LLC]]
| No Violations Noted
+
| style="text-align: right;" | 852,397.00
|  
+
| style="text-align: right;" | 366
|  
+
| style="text-align: right;" | 0.00
|  
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 3,970.00
 +
| style="text-align: right;" | 366
 
|-
 
|-
 +
| 2017
 +
| [[PENNENERGY RESOURCES LLC]]
 +
| style="text-align: right;" | 626,046.00
 +
| style="text-align: right;" | 327
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 2,726.00
 +
| style="text-align: right;" | 327
 
|-
 
|-
| 2361481
+
| 2018
| 2015-04-10
+
| [[PENNENERGY RESOURCES LLC]]
| No Violations Noted
+
| style="text-align: right;" | 573,675.00
|  
+
| style="text-align: right;" | 349
|  
+
| style="text-align: right;" | 0.00
|  
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 2,320.00
|-
+
| style="text-align: right;" | 349
|-
 
| 2365873
 
| 2015-04-28
 
| No Violations Noted
 
|  
 
|
 
|
 
|  
 
|-
 
 
|-
 
|-
| 2372368
+
| 2019
| 2015-04-02
+
| [[PENNENERGY RESOURCES LLC]]
| No Violations Noted
+
| style="text-align: right;" | 127,783.00
| THIS WELL HAS BEEN PRESURE TESTED BUT NOT FRACED. AN ABOVE GROUND TANK HAS BEEN CONSTRUCTED
+
| style="text-align: right;" | 78
|  
+
| style="text-align: right;" | 0.00
|  
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 525.00
 +
| style="text-align: right;" | 78
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =Oil and Gas Production Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Waste Type
!scope="col" | QUANTITY
+
!scope="col" | Quantity
!scope="col" | UNITS
+
!scope="col" | Disposal Method
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
|-
 
| 2014-2
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align:right;" | 745.0
 
| Bbl
 
| CENT WASTE TRT FAC NPDES DISCHARGE
 
| EPA ID: 748-163
 
| PATRIOT WATER TREATMENT
 
| WARREN
 
| OH
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
| style="text-align:right;" | 158.49
+
| style="text-align: right;" | 158.49 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| CID # 28726
 
| CID # 28726
| CARBON LIMESTONE LANDFILL - BFI
 
| LOWELLVILLE
 
| OH
 
|-
 
 
|-
 
|-
 
| 2014-2
 
| 2014-2
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
| style="text-align:right;" | 410.27
+
| style="text-align: right;" | 410.27 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| CID # 28726
 
| CID # 28726
| CARBON LIMESTONE LANDFILL - BFI
 
| LOWELLVILLE
 
| OH
 
 
|-
 
|-
 +
| 2014-2
 +
| Drilling Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 745.00 Bbl
 +
| CENT WASTE TRT FAC NPDES DISCHARGE
 +
| EPA ID: 748-163
 
|-
 
|-
| 2015-2
+
| 2015-1
| Servicing Fluid (in Barrels)
+
| Fracturing Fluid Waste (in Tons)
| style="text-align:right;" | 12.0
+
| style="text-align: right;" | 61.17 Tons
| Bbl
 
 
| LANDFILL
 
| LANDFILL
 
| CID # 28726
 
| CID # 28726
| CARBON LIMESTONE LANDFILL - BFI
 
| LOWELLVILLE
 
| OH
 
 
|-
 
|-
|-
+
| 2015-2
| 2015-1
+
| Servicing Fluid (in Barrels)
| Fracturing Fluid Waste (in Tons)
+
| style="text-align: right;" | 12.00 Bbl
| style="text-align:right;" | 61.17
 
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| CID # 28726
 
| CID # 28726
| CARBON LIMESTONE LANDFILL - BFI
 
| LOWELLVILLE
 
| OH
 
|-
 
 
|-
 
|-
| 2017-06
+
| 2016-1
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 144.5
+
| style="text-align: right;" | 9,140.50 Bbl
| Bbl
+
| REUSE OTHER THAN ROAD SPREADING
| REUSE (AT WELL PAD)
 
|
 
| W15 (Well Pad Id: 150675)
 
 
|  
 
|  
| PA
 
 
|-
 
|-
 +
| 2016-2
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 209.81 Bbl
 +
| CENT WASTE TRT FAC NPDES DISCHARGE
 +
| EPA ID: 748-163
 
|-
 
|-
| 2017-03
+
| 2016-2
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 100.0
+
| style="text-align: right;" | 870.31 Bbl
| Bbl
+
| INJECTION DISPOSAL WELL
| REUSE (AT WELL PAD)
+
| 34-155-22403
|
 
| PER B11 (Well Pad Id: 152367)
 
|
 
| PA
 
 
|-
 
|-
 +
| 2016-2
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 853.45 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23196
 
|-
 
|-
| 2017-07
+
| 2016-2
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 68.05
+
| style="text-align: right;" | 393.90 Bbl
| Bbl
+
| INJECTION DISPOSAL WELL
| REUSE (AT WELL PAD)
+
| 34-155-23223
|
 
| W69 (Well Pad Id: 150802)
 
|
 
| PA
 
|-
 
 
|-
 
|-
| 2017-07
+
| 2016-2
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 65.98
+
| style="text-align: right;" | 2,994.36 Bbl
| Bbl
+
| REUSE OTHER THAN ROAD SPREADING
| REUSE (AT WELL PAD)
 
|
 
| W15 (Well Pad Id: 150675)
 
 
|  
 
|  
| PA
 
|-
 
 
|-
 
|-
 
| 2017-01
 
| 2017-01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 490.81
+
| style="text-align: right;" | 490.81 Bbl
| Bbl
 
| REUSE (AT WELL PAD)
 
|
 
| B2 (Well Pad Id: 145779)
 
|
 
| PA
 
|-
 
|-
 
| 2017-02
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align:right;" | 355.02
 
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| BEAVER PAD 8 (Well Pad Id: 151931)
 
|
 
| PA
 
|-
 
 
|-
 
|-
 
| 2017-02
 
| 2017-02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 26.55
+
| style="text-align: right;" | 355.02 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B11 (Well Pad Id: 152367)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2017-03
| 2017-12
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 129.1
+
| style="text-align: right;" | 329.00 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER W22 WELL PAD (Well Pad Id: 154293)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2017-04
| 2017-12
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 54.8
+
| style="text-align: right;" | 14.30 Bbl
| Bbl
+
| INJECTION DISPOSAL WELL
| REUSE (AT WELL PAD)
+
| 34-155-23196
|
 
| PER B39 (Well Pad Id: 153852)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2017-04
| 2017-12
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 24.0
+
| style="text-align: right;" | 315.00 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B15 (Well Pad Id: 153337)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2017-05
| 2017-08
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 224.6
+
| style="text-align: right;" | 379.00 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| W69 (Well Pad Id: 150802)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2017-06
| 2017-08
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 49.4
+
| style="text-align: right;" | 144.50 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B15 (Well Pad Id: 153337)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2017-07
| 2017-04
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 315.0
+
| style="text-align: right;" | 68.05 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B37 (Well Pad Id: 153038)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2017-08
| 2017-04
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 91.0
+
| style="text-align: right;" | 224.60 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B11 (Well Pad Id: 152367)
 
|
 
| PA
 
|-
 
 
|-
 
|-
 
| 2017-09
 
| 2017-09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 232.29
+
| style="text-align: right;" | 232.29 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B15 (Well Pad Id: 153337)
 
|
 
| PA
 
|-
 
 
|-
 
|-
 
| 2017-10
 
| 2017-10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 51.93
+
| style="text-align: right;" | 51.93 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B15 (Well Pad Id: 153337)
 
|
 
| PA
 
|-
 
 
|-
 
|-
 
| 2017-11
 
| 2017-11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 202.49
+
| style="text-align: right;" | 202.49 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B39 (Well Pad Id: 153852)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2017-12
| 2017-11
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 25.66
+
| style="text-align: right;" | 129.10 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B15 (Well Pad Id: 153337)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2018-01
| 2017-05
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 379.0
+
| style="text-align: right;" | 258.51 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B37 (Well Pad Id: 153038)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2018-02
| 2017-03
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 329.0
+
| style="text-align: right;" | 27.02 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| BEAVER PAD 8 (Well Pad Id: 151931)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2018-03
| 2017-06
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 174.6
+
| style="text-align: right;" | 24.76 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| W69 (Well Pad Id: 150802)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2018-04
| 2017-03
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 52.0
+
| style="text-align: right;" | 238.88 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B37 (Well Pad Id: 153038)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2018-05
| 2017-06
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 50.6
+
| style="text-align: right;" | 162.64 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B37 (Well Pad Id: 153038)
 
|
 
| PA
 
|-
 
|-
 
| 2017-04
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align:right;" | 14.3
 
| Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-155-23196
 
| NATALE #1 (SWIW #28)
 
| WARREN
 
| OH
 
|-
 
 
|-
 
|-
 
| 2018-06
 
| 2018-06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 111.17
+
| style="text-align: right;" | 111.17 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B34 WELL PAD (Well Pad Id: 153349)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2018-07
| 2018-06
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 188.9
+
| style="text-align: right;" | 27.96 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B24 (Well Pad Id: 154382)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2018-08
| 2018-03
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 24.76
+
| style="text-align: right;" | 168.69 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B39 (Well Pad Id: 153852)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2018-09
| 2018-03
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 298.78
+
| style="text-align: right;" | 26.84 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PAD W9 (Well Pad Id: 152144)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2018-10
| 2018-05
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 162.64
+
| style="text-align: right;" | 27.61 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B39 (Well Pad Id: 153852)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2018-11
| 2018-05
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 165.36
+
| style="text-align: right;" | 27.38 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B34 WELL PAD (Well Pad Id: 153349)
 
|
 
| PA
 
 
|-
 
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 28.50 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23223
 
|-
 
|-
| 2018-09
+
| 2018-12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 26.84
+
| style="text-align: right;" | 55.64 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B9 (Well Pad Id: 154521)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2019-01
| 2018-04
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 238.88
+
| style="text-align: right;" | 192.84 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B39 (Well Pad Id: 153852)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2019-02
| 2018-08
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 253.62
+
| style="text-align: right;" | 137.15 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B9 (Well Pad Id: 154521)
 
|
 
| PA
 
 
|-
 
|-
|-
+
| 2019-03
| 2018-12
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 55.64
+
| style="text-align: right;" | 277.23 Bbl
| Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
| PER B17 (Well Pad Id: 154383)
 
|
 
| PA
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 +
|-
 +
| 2260622
 +
| Primary Facility
 +
| 04/08/2014
 +
| Preoperation Inspection
 +
| No Violations Noted
 +
| This preoperational inspection satisfies operator's obligation as outlined under Title 58 , Ch 32 § 3258 a. 1.
 +
|-
 +
| 2267279
 +
| Primary Facility
 +
| 04/21/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The conductor was set for this well targeting the either the Genesee or the Marcellus layer. The inspection for this well was conducted concurrently with the inspection for site number 776908 (inspection report # 2267205).  The water impoundment was under construction at time of inspection. All E&S controls appeared to be installed according to plan and sufficient to prevent off-site transfer of sediment. No erosion or sedimentation issues were noted.
 +
|-
 +
| 2274999
 +
| Primary Facility
 +
| 04/16/2014
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| THE CONDUCTOR IS IN. A SOUND WALL IS BEING BUILT. STILL WORKING ON THE PAD.
 +
|-
 +
| 2275010
 +
| Primary Facility
 +
| 05/06/2014
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| HIGHLANDS 7 COMPLETED TOP HOLE AT 2,278'. THE SITE IS OK.
 +
|-
 +
| 2275014
 +
| Primary Facility
 +
| 04/23/2014
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| ROCKY MOUNTAIN DRILLING HAS INSTALLED 40' OF 20" CONDUCTOR PIPE. THE SITE IS OK.
 +
|-
 +
| 2276862
 +
| Primary Facility
 +
| 05/23/2014
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| TOP HOLE COMPLETE. RIG HAS MOVED FROM THE SITE.
 +
|-
 +
| 2276911
 +
| Primary Facility
 +
| 06/03/2014
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| TOP HOLE COMPLETE. ALL EQUIPTMENT REMOVED. PROTECTIVE COVER IS STILL DOWN.
 +
|-
 +
| 2288975
 +
| Primary Facility
 +
| 06/12/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The tophole was drilled for this well targeting the Genesee layer. The inspection for this well was conducted concurrently with the inspection for site number 776908.  The water impoundment was constructed but not lined at time of inspection. All E&S controls appeared to be installed according to plan and sufficient to prevent off-site transfer of sediment. A moderate slip was noted on the topsoil pile but adequate vegetative growth and E&S controls appeared to prevent off-site transport of sediment.
 
|-
 
|-
| 2018-12
+
| 2297592
| Produced Fluid (in Barrels) RWC 802
+
| Primary Facility
| style="text-align:right;" | 82.18
+
| 08/22/2014
| Bbl
+
| Routine/Complete Inspection
| REUSE (AT WELL PAD)
+
| No Violations Noted
|  
+
| The well targets the Genesee layer. The inspection for this well was conducted concurrently with the inspection for site number 776908.  Well was properly labeled. Topsoil pile had adequate vegetative growth. E&S controls were sufficient to prevent off-site transport of sediment. Damp area was noted at corner of containment. Department requests operator ensure containment is adequate to contain residual waste.
| PER W32 (Well Pad Id: 154389)
 
|
 
| PA
 
 
|-
 
|-
 +
| 2307359
 +
| Primary Facility
 +
| 09/11/2014
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| PATTERSON 259 DRILLING HORIZONTAL LEG AT 10,344'.
 
|-
 
|-
| 2018-02
+
| 2350395
| Produced Fluid (in Barrels) RWC 802
+
| Primary Facility
| style="text-align:right;" | 27.02
+
| 01/20/2015
| Bbl
+
| Complaint Inspection
| REUSE (AT WELL PAD)
+
| No Violations Noted
 
|  
 
|  
| PER B39 (Well Pad Id: 153852)
+
|-
 +
| 2361481
 +
| Primary Facility
 +
| 04/10/2015
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
| PA
 
 
|-
 
|-
|-
+
| 2365873
| 2018-02
+
| Primary Facility
| Produced Fluid (in Barrels) RWC 802
+
| 04/28/2015
| style="text-align:right;" | 29.56
+
| Routine/Complete Inspection
| Bbl
+
| No Violations Noted
| REUSE (AT WELL PAD)
 
|  
 
| PAD W9 (Well Pad Id: 152144)
 
 
|  
 
|  
| PA
 
 
|-
 
|-
 +
| 2372368
 +
| Primary Facility
 +
| 04/02/2015
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| THIS WELL HAS BEEN PRESURE TESTED BUT NOT FRACED. AN ABOVE GROUND TANK HAS BEEN CONSTRUCTED, AND A FRESH WATER IMPOUNDMENT IS NEARLY FULL.
 
|-
 
|-
| 2018-02
+
| 2374344
| Produced Fluid (in Barrels) RWC 802
+
| Primary Facility
| style="text-align:right;" | 237.48
+
| 05/26/2015
| Bbl
+
| Routine/Complete Inspection
| REUSE (AT WELL PAD)
+
| No Violations Noted
 
|  
 
|  
| PER W22 WELL PAD (Well Pad Id: 154293)
+
|-
 +
| 2381764
 +
| Primary Facility
 +
| 06/19/2015
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
| PA
 
 
|-
 
|-
 +
| 2383239
 +
| Primary Facility
 +
| 06/29/2015
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| THIS WELL IS FRACED AND SHUT-IN.
 +
|-
 +
| 2396615
 +
| Primary Facility
 +
| 08/04/2015
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| FLOWBACK IS COMPLETE. THE PAD IS COVERED AND IN GOOD CONDITION.
 
|-
 
|-
| 2018-01
+
| 2436856
| Produced Fluid (in Barrels) RWC 802
+
| Primary Facility
| style="text-align:right;" | 258.51
+
| 12/29/2015
| Bbl
+
| Routine/Complete Inspection
| REUSE (AT WELL PAD)
+
| No Violations Noted
|  
 
| PER W22 WELL PAD (Well Pad Id: 154293)
 
 
|  
 
|  
| PA
 
 
|-
 
|-
 +
| 2449371
 +
| Primary Facility
 +
| 2016-01-20
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| THIS WELL IS DRILLED, FRACED, AND PRODUCING.
 +
THE SITE AND PRODUCTION EQUIPTMENT ARE IN GOOD CONDITION.
 
|-
 
|-
| 2018-07
+
| 2481819
| Produced Fluid (in Barrels) RWC 802
+
| Primary Facility
| style="text-align:right;" | 250.5
+
| 2016-04-26
| Bbl
+
| Routine/Complete Inspection
| REUSE (AT WELL PAD)
+
| No Violations Noted
|
+
| THIS WELL HAS BEEN COMPLETED AND IS NOW PRODUCING.
| PER B24 (Well Pad Id: 154382)
+
THE SITE IS IN GOOD CONDITION.
|
 
| PA
 
 
|-
 
|-
 +
| 2561316
 +
| Primary Facility
 +
| 2017-02-14
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| On 2/14/2017, WQS Brian MacQuarrie onsite at unconventional well site. Act 9 sign installed and maintained. Freshwater impoundment installed and fenced in. Four wells in production. Two four hundred bbl tanks installed and maintained within secondary steel containment structure. Erosion and Sedimentation Best Management practices installed and maintained. Site stabilized in previously disturbed areas around pad and access road with vegetative growth. No apparent E/S issues.
 
|-
 
|-
| 2018-11
+
| 2665297
| Produced Fluid (in Barrels) RWC 802
+
| Primary Facility
| style="text-align:right;" | 240.2
+
| 2017-11-29
| Bbl
+
| Routine/Complete Inspection
| REUSE (AT WELL PAD)
+
| No Violations Noted
|  
+
| Site had been constructed as outlined in the E&S plan contained within the ESCGP.  All site and access road erosion controls had been implemented and properly maintained.  There was no observed accelerated erosion or sedimentation in relation to the site or access road.  All disturbed areas had been stabilized with vegetation attaining 70% uniform vegetative cover.  Well appeared to be equipped for production.  Two produced fluid tanks were located onsite within secondary containment.  Both the tanks and containment appeared to be in sound condition.  Freshwater impoundment located onsite and it contained what appeared to be freshwater.
| ZAHN PAD (Well Pad Id: 154656)
 
|
 
| PA
 
 
|-
 
|-
 +
| 2686192
 +
| Primary Facility
 +
| 2018-01-12
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Site had been constructed as outlined within the E&S Plan contained within the ESCGP.  All erosion controls had been implemented and maintained properly.  There was no observed accelerated erosion or sedimentation in relation to the site or access road.  Well appeared to be equipped for production.  Two brine tanks located onsite within secondary containment.  Both the tanks and containment appeared to be in sound condition.  Well development impoundment located onsite and it contained fluids.
 
|-
 
|-
| 2018-10
+
| 2856223
| Produced Fluid (in Barrels) RWC 802
+
| Primary Facility
| style="text-align:right;" | 27.61
+
| 2019-03-20
| Bbl
+
| Routine/Complete Inspection
| REUSE (AT WELL PAD)
+
| No Violations Noted
|  
+
| At the time of inspection well equipped for production. Two brine tanks within secondary containment and appears structurally sound. GPUs within secondary containment. No E&S issues.
| ZAHN PAD (Well Pad Id: 154656)
 
|
 
| PA
 
 
|-
 
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 
|-
 
|-
| 2018-12
+
|}-->
| Produced Fluid (in Barrels) RWC 802
+
<!--==== Penalties Applied ====
| style="text-align:right;" | 110.68
+
{| class="wikitable sortable" width="95%"
| Bbl
+
!scope="col" | Violation ID
| REUSE (AT WELL PAD)
+
!scope="col" | Penalty ID
|  
+
!scope="col" | Penalty Code
| ZAHN PAD (Well Pad Id: 154656)
+
!scope="col" | Penalty Status
|  
+
!scope="col" | Penalty Date
| PA
+
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 
|-
 
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|-
| 2018-11
+
| 1
| Produced Fluid (in Barrels) RWC 802
+
| 05/04/2015
| style="text-align:right;" | 27.38
+
| 05/15/2015
| Bbl
+
| style="text-align: right;" | 5301
| REUSE (AT WELL PAD)
+
| style="text-align: right;" | 10,448,700.0
|  
+
| style="text-align: right;" | 0
| PER B22 (Well Pad Id: 154384)
 
|
 
| PA
 
 
|-
 
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 2018-10
+
|- valign="top"
| Produced Fluid (in Barrels) RWC 802
+
| rowspan="17"| 1
| style="text-align:right;" | 69.25
+
| rowspan="1"| Scale Hib A
| Bbl
+
| rowspan="1"| Nalco
| REUSE (AT WELL PAD)
+
| rowspan="1"| Scale Inhibitor
|  
+
| Ethylene Glycol
| PER B22 (Well Pad Id: 154384)
+
| 107-21-1
|  
+
| style="text-align: right;" | 30
| PA
+
| style="text-align: right;" | 0.00313408
 +
| style="text-align: right;" | 3246.14
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand (Proppant)
 +
| rowspan="1"| Sargent
 +
| rowspan="1"| Proppant
 +
| Silica
 +
| 14808-60-7
 +
| style="text-align: right;" | 99.9
 +
| style="text-align: right;" | 12.1214
 +
| style="text-align: right;" | 12,554,800.0
 
|-
 
|-
| 2018-09
+
|- valign="top"
| Produced Fluid (in Barrels) RWC 802
+
| rowspan="1"| Iron Control A
| style="text-align:right;" | 134.42
+
| rowspan="1"| Nalco
| Bbl
+
| rowspan="1"| Iron Control
| REUSE (AT WELL PAD)
+
| Ethylene Glycol
|  
+
| 107-21-1
| PER B22 (Well Pad Id: 154384)
+
| style="text-align: right;" | 30
|  
+
| style="text-align: right;" | 0.00313544
| PA
+
| style="text-align: right;" | 3247.54
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"| PennEnergy Resources
 +
| rowspan="1"| Carrier/Base Fluid
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 85.7841
 +
| style="text-align: right;" | 88,851,200.0
 
|-
 
|-
| 2018-08
+
|- valign="top"
| Produced Fluid (in Barrels) RWC 802
+
| rowspan="1"| LEB 10X
| style="text-align:right;" | 168.69
+
| rowspan="1"| Weatherford
| Bbl
+
| rowspan="1"| Gel Breaker
| REUSE (AT WELL PAD)
+
| Ethylene Glycol
|  
+
| 107-21-1
| PER B22 (Well Pad Id: 154384)
+
| style="text-align: right;" | 40
|  
+
| style="text-align: right;" | 0.00001219
| PA
+
| style="text-align: right;" | 12.624
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="3"| EC6116A
 +
| rowspan="3"| Nalco
 +
| rowspan="3"| Biocide
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00577223
 +
| style="text-align: right;" | 5978.61
 
|-
 
|-
| 2018-07
+
| Polyethylene Glycol
| Produced Fluid (in Barrels) RWC 802
+
| 25322-68-3
| style="text-align:right;" | 27.96
+
| style="text-align: right;" | 60
| Bbl
+
| style="text-align: right;" | 0.0115445
| REUSE (AT WELL PAD)
+
| style="text-align: right;" | 11957.2
|  
 
| PER B22 (Well Pad Id: 154384)
 
|  
 
| PA
 
 
|-
 
|-
 +
| Dibromoacetonitrile
 +
| 3252-43-5
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.000962038
 +
| style="text-align: right;" | 996.435
 
|-
 
|-
| 2018-12
+
|- valign="top"
| Produced Fluid (in Barrels) RWC 802
+
| rowspan="1"| Unislik ST50
| style="text-align:right;" | 28.5
+
| rowspan="1"| CESI
| Bbl
+
| rowspan="1"| Friction Reducer
| INJECTION DISPOSAL WELL
+
| Petroleum Distillates, Hydrotreated Light
| 34-155-23223
+
| 64742-47-8
| NATALE #2 (SWIW #29)
+
| style="text-align: right;" | 30
| VIENNA
+
| style="text-align: right;" | 0.0235688
| OH
+
| style="text-align: right;" | 24411.5
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="6"| Unihib G
 +
| rowspan="6"| GeoSafe
 +
| rowspan="6"| Acid Corrosion Inhibitor
 +
| Thiourea
 +
| 62-56-6
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.00000652
 +
| style="text-align: right;" | 6.752
 
|-
 
|-
| 2019-02
+
| Glycol Ether
| Produced Fluid (in Barrels) RWC 802
+
| 112-34-5
| style="text-align:right;" | 28.1
+
| style="text-align: right;" | 60
| Bbl
+
| style="text-align: right;" | 0.000391132
| REUSE (AT WELL PAD)
+
| style="text-align: right;" | 405.116
|  
 
| PER W32 (Well Pad Id: 154389)
 
|  
 
| PA
 
 
|-
 
|-
 +
| Ethoxylated Alcohol
 +
| 68002-97-1
 +
| style="text-align: right;" | 35
 +
| style="text-align: right;" | 0.00022816
 +
| style="text-align: right;" | 236.318
 
|-
 
|-
| 2019-03
+
| Methanol
| Produced Fluid (in Barrels) RWC 802
+
| 67-56-1
| style="text-align:right;" | 277.23
+
| style="text-align: right;" | 5
| Bbl
+
| style="text-align: right;" | 0.00003259
| REUSE (AT WELL PAD)
+
| style="text-align: right;" | 33.76
|  
 
| PER W32 (Well Pad Id: 154389)
 
|  
 
| PA
 
 
|-
 
|-
 +
| Formaldehyde
 +
| 50-00-0
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.00000652
 +
| style="text-align: right;" | 6.752
 
|-
 
|-
| 2019-01
+
| Acetophenone
| Produced Fluid (in Barrels) RWC 802
+
| 98-86-2
| style="text-align:right;" | 192.84
+
| style="text-align: right;" | 1
| Bbl
+
| style="text-align: right;" | 0.00000652
| REUSE (AT WELL PAD)
+
| style="text-align: right;" | 6.752
|  
 
| PER B17 (Well Pad Id: 154383)
 
|  
 
| PA
 
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Hydrochloric Acid (7.5%)
 +
| rowspan="1"| Axiall
 +
| rowspan="1"| Acidizing
 +
| Hydrogen Chloride
 +
| 7647-01-0
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 0.784691
 +
| style="text-align: right;" | 812747
 
|-
 
|-
| 2019-02
+
|- valign="top"
| Produced Fluid (in Barrels) RWC 802
+
| rowspan="1"| WGA-3
| style="text-align:right;" | 137.15
+
| rowspan="1"| PfP Technology
| Bbl
+
| rowspan="1"| Water Viscosifier
| REUSE (AT WELL PAD)
+
| Guar Gum
|  
+
| 9000-30-0
| PER B17 (Well Pad Id: 154383)
+
| style="text-align: right;" | 100
|
+
| style="text-align: right;" | 0.00120685
| PA
+
| style="text-align: right;" | 1250
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-26 }}</ref>
+
==References==
== References ==
+
<references/>
{{reflist}}
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 18:23, 13 July 2019

Well Details

Well ID: 37-007-20412
Loading map...
Country: United States
State: Pennsylvania
County: Beaver
Municipality: New Sewickley Township
Operator Name: PENNENERGY RESOURCES LLC
Well Pad ID: 150486
Farm/Lease Name: B3 PER B3-2H
License Status: Active
Spud Date: 04/10/2014
Permit Date: 11/12/2013
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.760197
Longitude: -80.167083

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 PENNENERGY RESOURCES LLC 0.00 0 0.00 0 0.00 0
2015 PENNENERGY RESOURCES LLC 377,255.00 105 0.00 0 2,513.00 105
2016 PENNENERGY RESOURCES LLC 852,397.00 366 0.00 0 3,970.00 366
2017 PENNENERGY RESOURCES LLC 626,046.00 327 0.00 0 2,726.00 327
2018 PENNENERGY RESOURCES LLC 573,675.00 349 0.00 0 2,320.00 349
2019 PENNENERGY RESOURCES LLC 127,783.00 78 0.00 0 525.00 78

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2014-1 Drill Cuttings (in Tons) 158.49 Tons LANDFILL CID # 28726
2014-2 Drill Cuttings (in Tons) 410.27 Tons LANDFILL CID # 28726
2014-2 Drilling Fluid Waste (in Barrels) 745.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE EPA ID: 748-163
2015-1 Fracturing Fluid Waste (in Tons) 61.17 Tons LANDFILL CID # 28726
2015-2 Servicing Fluid (in Barrels) 12.00 Bbl LANDFILL CID # 28726
2016-1 Produced Fluid (in Barrels) RWC 802 9,140.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Produced Fluid (in Barrels) RWC 802 209.81 Bbl CENT WASTE TRT FAC NPDES DISCHARGE EPA ID: 748-163
2016-2 Produced Fluid (in Barrels) RWC 802 870.31 Bbl INJECTION DISPOSAL WELL 34-155-22403
2016-2 Produced Fluid (in Barrels) RWC 802 853.45 Bbl INJECTION DISPOSAL WELL 34-155-23196
2016-2 Produced Fluid (in Barrels) RWC 802 393.90 Bbl INJECTION DISPOSAL WELL 34-155-23223
2016-2 Produced Fluid (in Barrels) RWC 802 2,994.36 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Produced Fluid (in Barrels) RWC 802 490.81 Bbl REUSE (AT WELL PAD)
2017-02 Produced Fluid (in Barrels) RWC 802 355.02 Bbl REUSE (AT WELL PAD)
2017-03 Produced Fluid (in Barrels) RWC 802 329.00 Bbl REUSE (AT WELL PAD)
2017-04 Produced Fluid (in Barrels) RWC 802 14.30 Bbl INJECTION DISPOSAL WELL 34-155-23196
2017-04 Produced Fluid (in Barrels) RWC 802 315.00 Bbl REUSE (AT WELL PAD)
2017-05 Produced Fluid (in Barrels) RWC 802 379.00 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 144.50 Bbl REUSE (AT WELL PAD)
2017-07 Produced Fluid (in Barrels) RWC 802 68.05 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 224.60 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 232.29 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 51.93 Bbl REUSE (AT WELL PAD)
2017-11 Produced Fluid (in Barrels) RWC 802 202.49 Bbl REUSE (AT WELL PAD)
2017-12 Produced Fluid (in Barrels) RWC 802 129.10 Bbl REUSE (AT WELL PAD)
2018-01 Produced Fluid (in Barrels) RWC 802 258.51 Bbl REUSE (AT WELL PAD)
2018-02 Produced Fluid (in Barrels) RWC 802 27.02 Bbl REUSE (AT WELL PAD)
2018-03 Produced Fluid (in Barrels) RWC 802 24.76 Bbl REUSE (AT WELL PAD)
2018-04 Produced Fluid (in Barrels) RWC 802 238.88 Bbl REUSE (AT WELL PAD)
2018-05 Produced Fluid (in Barrels) RWC 802 162.64 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 111.17 Bbl REUSE (AT WELL PAD)
2018-07 Produced Fluid (in Barrels) RWC 802 27.96 Bbl REUSE (AT WELL PAD)
2018-08 Produced Fluid (in Barrels) RWC 802 168.69 Bbl REUSE (AT WELL PAD)
2018-09 Produced Fluid (in Barrels) RWC 802 26.84 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 27.61 Bbl REUSE (AT WELL PAD)
2018-11 Produced Fluid (in Barrels) RWC 802 27.38 Bbl REUSE (AT WELL PAD)
2018-12 Produced Fluid (in Barrels) RWC 802 28.50 Bbl INJECTION DISPOSAL WELL 34-155-23223
2018-12 Produced Fluid (in Barrels) RWC 802 55.64 Bbl REUSE (AT WELL PAD)
2019-01 Produced Fluid (in Barrels) RWC 802 192.84 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 137.15 Bbl REUSE (AT WELL PAD)
2019-03 Produced Fluid (in Barrels) RWC 802 277.23 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2260622 Primary Facility 04/08/2014 Preoperation Inspection No Violations Noted This preoperational inspection satisfies operator's obligation as outlined under Title 58 , Ch 32 § 3258 a. 1.
2267279 Primary Facility 04/21/2014 Routine/Complete Inspection No Violations Noted The conductor was set for this well targeting the either the Genesee or the Marcellus layer. The inspection for this well was conducted concurrently with the inspection for site number 776908 (inspection report # 2267205). The water impoundment was under construction at time of inspection. All E&S controls appeared to be installed according to plan and sufficient to prevent off-site transfer of sediment. No erosion or sedimentation issues were noted.
2274999 Primary Facility 04/16/2014 Drilling/Alteration No Violations Noted THE CONDUCTOR IS IN. A SOUND WALL IS BEING BUILT. STILL WORKING ON THE PAD.
2275010 Primary Facility 05/06/2014 Drilling/Alteration No Violations Noted HIGHLANDS 7 COMPLETED TOP HOLE AT 2,278'. THE SITE IS OK.
2275014 Primary Facility 04/23/2014 Drilling/Alteration No Violations Noted ROCKY MOUNTAIN DRILLING HAS INSTALLED 40' OF 20" CONDUCTOR PIPE. THE SITE IS OK.
2276862 Primary Facility 05/23/2014 Drilling/Alteration No Violations Noted TOP HOLE COMPLETE. RIG HAS MOVED FROM THE SITE.
2276911 Primary Facility 06/03/2014 Drilling/Alteration No Violations Noted TOP HOLE COMPLETE. ALL EQUIPTMENT REMOVED. PROTECTIVE COVER IS STILL DOWN.
2288975 Primary Facility 06/12/2014 Routine/Complete Inspection No Violations Noted The tophole was drilled for this well targeting the Genesee layer. The inspection for this well was conducted concurrently with the inspection for site number 776908. The water impoundment was constructed but not lined at time of inspection. All E&S controls appeared to be installed according to plan and sufficient to prevent off-site transfer of sediment. A moderate slip was noted on the topsoil pile but adequate vegetative growth and E&S controls appeared to prevent off-site transport of sediment.
2297592 Primary Facility 08/22/2014 Routine/Complete Inspection No Violations Noted The well targets the Genesee layer. The inspection for this well was conducted concurrently with the inspection for site number 776908. Well was properly labeled. Topsoil pile had adequate vegetative growth. E&S controls were sufficient to prevent off-site transport of sediment. Damp area was noted at corner of containment. Department requests operator ensure containment is adequate to contain residual waste.
2307359 Primary Facility 09/11/2014 Drilling/Alteration No Violations Noted PATTERSON 259 DRILLING HORIZONTAL LEG AT 10,344'.
2350395 Primary Facility 01/20/2015 Complaint Inspection No Violations Noted
2361481 Primary Facility 04/10/2015 Routine/Complete Inspection No Violations Noted
2365873 Primary Facility 04/28/2015 Routine/Complete Inspection No Violations Noted
2372368 Primary Facility 04/02/2015 Drilling/Alteration No Violations Noted THIS WELL HAS BEEN PRESURE TESTED BUT NOT FRACED. AN ABOVE GROUND TANK HAS BEEN CONSTRUCTED, AND A FRESH WATER IMPOUNDMENT IS NEARLY FULL.
2374344 Primary Facility 05/26/2015 Routine/Complete Inspection No Violations Noted
2381764 Primary Facility 06/19/2015 Routine/Complete Inspection No Violations Noted
2383239 Primary Facility 06/29/2015 Drilling/Alteration No Violations Noted THIS WELL IS FRACED AND SHUT-IN.
2396615 Primary Facility 08/04/2015 Drilling/Alteration No Violations Noted FLOWBACK IS COMPLETE. THE PAD IS COVERED AND IN GOOD CONDITION.
2436856 Primary Facility 12/29/2015 Routine/Complete Inspection No Violations Noted
2449371 Primary Facility 2016-01-20 Routine/Complete Inspection No Violations Noted THIS WELL IS DRILLED, FRACED, AND PRODUCING.

THE SITE AND PRODUCTION EQUIPTMENT ARE IN GOOD CONDITION.

2481819 Primary Facility 2016-04-26 Routine/Complete Inspection No Violations Noted THIS WELL HAS BEEN COMPLETED AND IS NOW PRODUCING.

THE SITE IS IN GOOD CONDITION.

2561316 Primary Facility 2017-02-14 Routine/Complete Inspection No Violations Noted On 2/14/2017, WQS Brian MacQuarrie onsite at unconventional well site. Act 9 sign installed and maintained. Freshwater impoundment installed and fenced in. Four wells in production. Two four hundred bbl tanks installed and maintained within secondary steel containment structure. Erosion and Sedimentation Best Management practices installed and maintained. Site stabilized in previously disturbed areas around pad and access road with vegetative growth. No apparent E/S issues.
2665297 Primary Facility 2017-11-29 Routine/Complete Inspection No Violations Noted Site had been constructed as outlined in the E&S plan contained within the ESCGP. All site and access road erosion controls had been implemented and properly maintained. There was no observed accelerated erosion or sedimentation in relation to the site or access road. All disturbed areas had been stabilized with vegetation attaining 70% uniform vegetative cover. Well appeared to be equipped for production. Two produced fluid tanks were located onsite within secondary containment. Both the tanks and containment appeared to be in sound condition. Freshwater impoundment located onsite and it contained what appeared to be freshwater.
2686192 Primary Facility 2018-01-12 Routine/Complete Inspection No Violations Noted Site had been constructed as outlined within the E&S Plan contained within the ESCGP. All erosion controls had been implemented and maintained properly. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Well appeared to be equipped for production. Two brine tanks located onsite within secondary containment. Both the tanks and containment appeared to be in sound condition. Well development impoundment located onsite and it contained fluids.
2856223 Primary Facility 2019-03-20 Routine/Complete Inspection No Violations Noted At the time of inspection well equipped for production. Two brine tanks within secondary containment and appears structurally sound. GPUs within secondary containment. No E&S issues.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 05/04/2015 05/15/2015 5301 10,448,700.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Scale Hib A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00313408 3246.14
Sand (Proppant) Sargent Proppant Silica 14808-60-7 99.9 12.1214 12,554,800.0
Iron Control A Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00313544 3247.54
Water PennEnergy Resources Carrier/Base Fluid Water 7732-18-5 100 85.7841 88,851,200.0
LEB 10X Weatherford Gel Breaker Ethylene Glycol 107-21-1 40 0.00001219 12.624
EC6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00577223 5978.61
Polyethylene Glycol 25322-68-3 60 0.0115445 11957.2
Dibromoacetonitrile 3252-43-5 5 0.000962038 996.435
Unislik ST50 CESI Friction Reducer Petroleum Distillates, Hydrotreated Light 64742-47-8 30 0.0235688 24411.5
Unihib G GeoSafe Acid Corrosion Inhibitor Thiourea 62-56-6 1 0.00000652 6.752
Glycol Ether 112-34-5 60 0.000391132 405.116
Ethoxylated Alcohol 68002-97-1 35 0.00022816 236.318
Methanol 67-56-1 5 0.00003259 33.76
Formaldehyde 50-00-0 1 0.00000652 6.752
Acetophenone 98-86-2 1 0.00000652 6.752
Hydrochloric Acid (7.5%) Axiall Acidizing Hydrogen Chloride 7647-01-0 40 0.784691 812747
WGA-3 PfP Technology Water Viscosifier Guar Gum 9000-30-0 100 0.00120685 1250

For data sources see[7]