If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
| Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-059-26140 | | Well ID: 37-059-26140 | ||
| − | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="14" | {{#display_map: 39.986367, -80.137689 | width=100% | height=100% }} |
|- | |- | ||
| − | | | + | | Country: United States |
|- | |- | ||
| − | | | + | | State: Pennsylvania |
|- | |- | ||
| − | | | + | | County: [[Greene_County,_Pennsylvania|Greene]] |
|- | |- | ||
| − | | | + | | Municipality: [[Washington Township,_Greene_County,_Pennsylvania|Washington Township]] |
|- | |- | ||
| − | | | + | | Operator Name: [[EQT PROD CO]] |
|- | |- | ||
| − | | | + | | Well Pad ID: [[145143]] |
|- | |- | ||
| − | | | + | | Farm/Lease Name: SANDERS 591573 |
| − | |||
| − | |||
|- | |- | ||
| − | | | + | | License Status: Active |
|- | |- | ||
| − | | | + | | Spud Date: 06/11/2013 |
|- | |- | ||
| − | | | + | | Permit Date: 3/26/2013 |
|- | |- | ||
| − | | | + | | Unconventional Well: Y |
|- | |- | ||
| − | | | + | | Configuration: Horizontal Well |
|- | |- | ||
| − | | | + | | Latitude: 39.986367 |
|- | |- | ||
| + | | Longitude: -80.137689 | ||
|} | |} | ||
| + | For data sources see<ref>{{cite web | ||
| + | | title = Permits Issued Detail Report | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-05-20 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
| + | | title = Spud Data Report | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-04-30 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
| + | | title = Oil and Gas Well Pad Report | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-05-20 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-21 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
| − | !scope="col" | | + | !scope="col" | Period |
| − | !scope="col" | | + | !scope="col" | Operator Name |
| − | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
| − | !scope="col" | | + | !scope="col" | Gas Production Days |
| − | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
| − | !scope="col" | | + | !scope="col" | Oil Production Days |
| − | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
| − | + | !scope="col" | Water Production Days | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| − | | | + | | 2013 |
| − | | | + | | [[EQT PROD CO]] |
| − | + | | style="text-align: right;" | 0.00 | |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| − | + | | style="text-align: right;" | 0 | |
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | | style="text-align:right;" | 0. | ||
| − | | style="text-align:right;" | | ||
| − | |||
|- | |- | ||
| + | | 2014 | ||
| + | | [[EQT PROD CO]] | ||
| + | | style="text-align: right;" | 1,661,111.00 | ||
| + | | style="text-align: right;" | 216 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| − | | 2015 | + | | 2015 |
| − | | style="text-align:right;" | | + | | [[EQT PROD CO]] |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 1,243,658.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 353 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| + | | 2016 | ||
| + | | [[EQT PROD CO]] | ||
| + | | style="text-align: right;" | 879,893.00 | ||
| + | | style="text-align: right;" | 366 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| − | | | + | | 2017 |
| − | | style="text-align:right;" | | + | | [[EQT PROD CO]] |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 624,094.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 352 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| + | | 2018 | ||
| + | | [[EQT PROD CO]] | ||
| + | | style="text-align: right;" | 505,925.00 | ||
| + | | style="text-align: right;" | 351 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| − | | | + | | 2019 |
| − | | style="text-align:right;" | | + | | [[EQT PROD CO]] |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 108,929.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 90 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| − | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
| − | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
| − | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
| − | + | | date = 2019-03-31 | |
| − | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
| − | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
| − | !scope="col" | | + | !scope="col" | Period |
| − | !scope="col" | | + | !scope="col" | Waste Type |
| − | !scope="col" | | + | !scope="col" | Quantity |
| − | !scope="col" | | + | !scope="col" | Disposal Method |
| − | !scope="col" | | + | !scope="col" | Waste Facility ID |
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| 2013-1 | | 2013-1 | ||
| − | | | + | | Drilling Fluid Waste (in Barrels) |
| − | | style="text-align:right;" | 112. | + | | style="text-align: right;" | 112.00 Bbl |
| − | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
| − | | | + | | Drilling Fluid Waste (in Barrels) |
| − | | style="text-align:right;" | 850. | + | | style="text-align: right;" | 850.00 Bbl |
| − | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| − | |||
| − | |||
| − | |||
| | | | ||
| − | |||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
| − | | | + | | Fracing Fluid Waste (in Barrels) |
| − | | style="text-align:right;" | 25. | + | | style="text-align: right;" | 25.00 Bbl |
| − | |||
| CENT WASTE TRT FAC NPDES DISCHARGE | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
| EPA ID: 748-163 | | EPA ID: 748-163 | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
| − | | | + | | Fracing Fluid Waste (in Barrels) |
| − | | style="text-align:right;" | 8. | + | | style="text-align: right;" | 8,480.00 Bbl |
| − | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
| − | | | + | |- |
| − | | | + | | 2014-1 |
| + | | Drilling Fluid Waste (in Barrels) | ||
| + | | style="text-align: right;" | 260.00 Bbl | ||
| + | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
| − | |||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
| − | | | + | | Fracing Fluid Waste (in Barrels) |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 14,211.00 Bbl |
| − | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| − | |||
| − | |||
| − | |||
| | | | ||
| − | |||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
| − | | | + | | Fracturing Fluid Waste (in Tons) |
| − | | style="text-align:right;" | 24.28 | + | | style="text-align: right;" | 24.28 Tons |
| − | |||
| LANDFILL | | LANDFILL | ||
| 100419 | | 100419 | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
| − | | | + | | Fracturing Fluid Waste (in Tons) |
| − | | style="text-align:right;" | 3.76 | + | | style="text-align: right;" | 3.76 Tons |
| − | |||
| LANDFILL | | LANDFILL | ||
| SWF 1032-WV0109 | | SWF 1032-WV0109 | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| + | | 2014-1 | ||
| + | | Produced Fluid (in Barrels) | ||
| + | | style="text-align: right;" | 819.00 Bbl | ||
| + | | INJECTION DISPOSAL WELL | ||
| + | | 34-031-27177 | ||
| + | |- | ||
| + | | 2014-1 | ||
| + | | Produced Fluid (in Barrels) | ||
| + | | style="text-align: right;" | 564.00 Bbl | ||
| + | | INJECTION DISPOSAL WELL | ||
| + | | 34-059-24202 | ||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
| − | | | + | | Produced Fluid (in Barrels) |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 4,055.00 Bbl |
| − | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
| − | | REUSE | + | |- |
| + | | 2014-2 | ||
| + | | Fracing Fluid Waste (in Barrels) | ||
| + | | style="text-align: right;" | 1,073.00 Bbl | ||
| + | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
| + | |- | ||
| + | | 2014-2 | ||
| + | | Produced Fluid (in Barrels) | ||
| + | | style="text-align: right;" | 2,769.00 Bbl | ||
| + | | INJECTION DISPOSAL WELL | ||
| + | | 34-031-27177 | ||
| + | |- | ||
| + | | 2014-2 | ||
| + | | Produced Fluid (in Barrels) | ||
| + | | style="text-align: right;" | 290.00 Bbl | ||
| + | | INJECTION DISPOSAL WELL | ||
| + | | 34-059-24202 | ||
| + | |- | ||
| + | | 2014-2 | ||
| + | | Produced Fluid (in Barrels) | ||
| + | | style="text-align: right;" | 80.00 Bbl | ||
| + | | INJECTION DISPOSAL WELL | ||
| + | | 34-155-21438 | ||
| + | |- | ||
| + | | 2014-2 | ||
| + | | Produced Fluid (in Barrels) | ||
| + | | style="text-align: right;" | 199.00 Bbl | ||
| + | | INJECTION DISPOSAL WELL | ||
| + | | 34-157-25511 | ||
| + | |- | ||
| + | | 2014-2 | ||
| + | | Produced Fluid (in Barrels) | ||
| + | | style="text-align: right;" | 11,800.00 Bbl | ||
| + | | REUSE OTHER THAN ROAD SPREADING | ||
| + | | | ||
| + | |- | ||
| + | | 2015-1 | ||
| + | | Fracing Fluid Waste (in Barrels) | ||
| + | | style="text-align: right;" | 1,786.00 Bbl | ||
| + | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
| + | | 2015-1 | ||
| + | | Fracturing Fluid Waste (in Tons) | ||
| + | | style="text-align: right;" | 36.00 Tons | ||
| + | | LANDFILL | ||
| + | | SWF 1032-WV0109 | ||
|- | |- | ||
| − | | | + | | 2015-1 |
| − | | | + | | Produced Fluid (in Barrels) |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 90.00 Bbl |
| − | | Bbl | + | | INJECTION DISPOSAL WELL |
| + | | 34-059-24202 | ||
| + | |- | ||
| + | | 2015-1 | ||
| + | | Produced Fluid (in Barrels) | ||
| + | | style="text-align: right;" | 350.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| − | | 34- | + | | 34-157-25511 |
| − | |||
| − | |||
| − | |||
|- | |- | ||
| + | | 2015-1 | ||
| + | | Produced Fluid (in Barrels) | ||
| + | | style="text-align: right;" | 110.00 Bbl | ||
| + | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| + | | WMGR123SW005 | ||
|- | |- | ||
| − | | | + | | 2015-1 |
| − | | | + | | Produced Fluid (in Barrels) |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 7,863.00 Bbl |
| − | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
| − | | REUSE | + | |- |
| + | | 2015-2 | ||
| + | | Produced Fluid (in Barrels) | ||
| + | | style="text-align: right;" | 2,390.00 Bbl | ||
| + | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
| + | |- | ||
| + | | 2016-1 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 706.00 Bbl | ||
| + | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
| + | | 2016-1 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 2,363.00 Bbl | ||
| + | | REUSE OTHER THAN ROAD SPREADING | ||
| + | | | ||
|- | |- | ||
| − | | | + | | 2016-2 |
| − | | | + | | Other Oil & Gas Wastes (in Barrels) RWC 899 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 75.00 Bbl |
| − | + | | RESIDUAL WASTE PROCESSING FACILITY | |
| − | | | + | | WMGR123SW005 |
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| + | | 2016-2 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 322.00 Bbl | ||
| + | | REUSE OTHER THAN ROAD SPREADING | ||
| + | | | ||
|- | |- | ||
| − | | | + | | 2016-2 |
| − | | | + | | Produced Fluid (in Barrels) RWC 802 |
| − | | style="text-align:right;" | 1. | + | | style="text-align: right;" | 1,730.00 Bbl |
| − | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
| − | | REUSE | + | |- |
| + | | 2017-01 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 410.00 Bbl | ||
| + | | RESIDUAL WASTE PROCESSING FACILITY | ||
| + | | WMGR123SW005 | ||
| + | |- | ||
| + | | 2017-01 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 100.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2017-01 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 110.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2017-02 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 440.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2017-02 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 210.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| | | | ||
| + | |- | ||
| + | | 2017-03 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 410.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
| + | | 2017-03 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 110.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
|- | |- | ||
| − | | | + | | 2017-04 |
| − | | | + | | Other Oil & Gas Wastes (in Barrels) RWC 899 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 110.00 Bbl |
| − | | Bbl | + | | REUSE (AT WELL PAD) |
| + | | | ||
| + | |- | ||
| + | | 2017-04 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 660.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2017-05 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 110.00 Bbl | ||
| + | | RESIDUAL WASTE PROCESSING FACILITY | ||
| + | | WMGR123SW005 | ||
| + | |- | ||
| + | | 2017-06 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 325.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2017-07 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 130.00 Bbl | ||
| + | | RESIDUAL WASTE PROCESSING FACILITY | ||
| + | | WMGR123SW010 | ||
| + | |- | ||
| + | | 2017-07 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 260.00 Bbl | ||
| + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| + | | | ||
| + | |- | ||
| + | | 2017-08 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 60.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2017-08 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 720.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2017-10 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 65.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2017-11 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 130.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2017-12 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 130.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-01 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 260.00 Bbl | ||
| + | | RESIDUAL WASTE PROCESSING FACILITY | ||
| + | | WMGR123SW005 | ||
| + | |- | ||
| + | | 2018-01 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 65.00 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-02 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 11.49 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| − | | 34- | + | | 34-009-23823 |
| − | | | + | |- |
| − | | | + | | 2018-02 |
| − | | | + | | Produced Fluid (in Barrels) RWC 802 |
| + | | style="text-align: right;" | 34.47 Bbl | ||
| + | | RESIDUAL WASTE PROCESSING FACILITY | ||
| + | | WMGR123SW005 | ||
| + | |- | ||
| + | | 2018-02 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 22.98 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-03 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 11.12 Bbl | ||
| + | | RESIDUAL WASTE PROCESSING FACILITY | ||
| + | | WMGR123SW005 | ||
| + | |- | ||
| + | | 2018-03 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 11.12 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-04 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 9.29 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-04 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 32.76 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-05 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 269.71 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-06 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 20.01 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-07 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 55.71 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-07 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 42.67 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-08 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 8.80 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-09 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 10.38 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
| + | |- | ||
| + | | 2018-10 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 8.48 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
|- | |- | ||
| + | | 2018-11 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 0.63 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
|- | |- | ||
| − | | | + | | 2018-12 |
| − | | | + | | Produced Fluid (in Barrels) RWC 802 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 40.08 Bbl |
| − | + | | RESIDUAL WASTE PROCESSING FACILITY | |
| − | | | + | | WMGR123SW005 |
| − | |||
| − | |||
| − | |||
| − | | | ||
|- | |- | ||
| + | | 2018-12 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 63.55 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
|- | |- | ||
| − | | | + | | 2019-01 |
| − | | | + | | Other Oil & Gas Wastes (in Barrels) RWC 899 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 25.00 Bbl |
| − | + | | REUSE (AT WELL PAD) | |
| − | | | + | | |
| − | |||
| − | |||
| − | | | ||
| − | |||
|- | |- | ||
| + | | 2019-01 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 212.37 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
|- | |- | ||
| − | | | + | | 2019-02 |
| − | | | + | | Other Oil & Gas Wastes (in Barrels) RWC 899 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 8.57 Bbl |
| − | + | | REUSE (AT WELL PAD) | |
| − | | REUSE | ||
| | | | ||
| − | | | + | |- |
| + | | 2019-02 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 46.30 Bbl | ||
| + | | RESIDUAL WASTE PROCESSING FACILITY | ||
| | | | ||
| + | |- | ||
| + | | 2019-02 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 54.64 Bbl | ||
| + | | RESIDUAL WASTE PROCESSING FACILITY | ||
| + | | WMGR123SW005 | ||
| + | |- | ||
| + | | 2019-02 | ||
| + | | Produced Fluid (in Barrels) RWC 802 | ||
| + | | style="text-align: right;" | 9.11 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
| + | | 2019-03 | ||
| + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| + | | style="text-align: right;" | 61.43 Bbl | ||
| + | | REUSE (AT WELL PAD) | ||
| + | | | ||
|- | |- | ||
| − | | | + | | 2019-03 |
| − | | | + | | Produced Fluid (in Barrels) RWC 802 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 10.14 Bbl |
| − | + | | REUSE (AT WELL PAD) | |
| − | | | + | | |
| − | |||
| − | |||
| − | | | ||
| − | |||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
| − | | title = Oil and Gas | + | | title =Oil and Gas Waste Reports |
| − | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
| − | + | | date = 2019-03-31 | |
| − | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
| − | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Inspection Data == | == Inspection Data == | ||
| + | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
| − | !scope="col" | | + | !scope="col" | Inspection ID |
| − | !scope="col" | | + | !scope="col" | Inspection Category |
| − | !scope="col" | | + | !scope="col" | Inspection Date |
| − | !scope="col" | | + | !scope="col" | Inspection Type |
| − | !scope="col" | | + | !scope="col" | Inspection Result |
| − | + | !scope="col" | Inspection Comments | |
| − | !scope="col" | | ||
|- | |- | ||
| 2173034 | | 2173034 | ||
| − | | | + | | Primary Facility |
| + | | 06/06/2013 | ||
| + | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| Pre-operation inspection requested by the Operator on 5/30/2013. At the time of inspection the erosion and sedimentation plan was on site. All perimeter BMPs appear to installed and functioning properly. No observation of accelerated erosion or sedimentation in relation to the well pad or access road at the time of inspection. The Department suggests the Operator continue to inspect the site weekly and after significant precipitation event to ensure the stability of the site in maintained. | | Pre-operation inspection requested by the Operator on 5/30/2013. At the time of inspection the erosion and sedimentation plan was on site. All perimeter BMPs appear to installed and functioning properly. No observation of accelerated erosion or sedimentation in relation to the well pad or access road at the time of inspection. The Department suggests the Operator continue to inspect the site weekly and after significant precipitation event to ensure the stability of the site in maintained. | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| 2184980 | | 2184980 | ||
| − | | | + | | Primary Facility |
| + | | 07/11/2013 | ||
| + | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| CONDUCTOR SET. WAITING FOR RIG TO SKID AND COMMENCE DRILLING OF TOP HOLE. | | CONDUCTOR SET. WAITING FOR RIG TO SKID AND COMMENCE DRILLING OF TOP HOLE. | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| 2206187 | | 2206187 | ||
| − | | | + | | Primary Facility |
| + | | 09/03/2013 | ||
| + | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| VERTICAL SECTION OF WELL DRILLED TO COMPLETION. WAITING FOR HORIZONTAL RIG TO MOVE IN AND COMPLETE DRILLING OF WELL. | | VERTICAL SECTION OF WELL DRILLED TO COMPLETION. WAITING FOR HORIZONTAL RIG TO MOVE IN AND COMPLETE DRILLING OF WELL. | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| 2213100 | | 2213100 | ||
| − | | | + | | Primary Facility |
| + | | 10/09/2013 | ||
| + | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| DRILLING OF WELL COMPLETE. WELL READY FOR STIMULATION. | | DRILLING OF WELL COMPLETE. WELL READY FOR STIMULATION. | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| + | | 2294914 | ||
| + | | Primary Facility | ||
| + | | 06/16/2014 | ||
| + | | Routine/Complete Inspection | ||
| + | | No Violations Noted | ||
| + | | Well in compliance. | ||
|- | |- | ||
| 2350925 | | 2350925 | ||
| − | | 2015- | + | | Primary Facility |
| + | | 01/29/2015 | ||
| + | | Routine/Complete Inspection | ||
| + | | No Violations Noted | ||
| + | | Well drilled, and in production. | ||
| + | |- | ||
| + | | 2403372 | ||
| + | | Primary Facility | ||
| + | | 08/28/2015 | ||
| + | | Complaint Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| − | | | + | | 14 wells drilled and equipped for production. 14 upright tanks and 7 skid tanks onsite. Id sign and e&s ok. |
| − | | | + | |- |
| − | | | + | | 2418796 |
| − | | | + | | Primary Facility |
| + | | 10/15/2015 | ||
| + | | Routine/Complete Inspection | ||
| + | | No Violations Noted | ||
| + | | On 10/15/15, I conducted a routine complete inspection of the Sanders site and made the following observations: | ||
|- | |- | ||
|} | |} | ||
| + | <!--==== Violations Commited ==== | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Inspection ID | ||
| + | !scope="col" | Violation ID | ||
| + | !scope="col" | Violation Date | ||
| + | !scope="col" | Date Resolved | ||
| + | !scope="col" | Violation Code | ||
| + | !scope="col" | Violation Type | ||
| + | !scope="col" | Violation Comments | ||
| + | |- | ||
| + | |}--> | ||
| + | <!--==== Penalties Applied ==== | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Violation ID | ||
| + | !scope="col" | Penalty ID | ||
| + | !scope="col" | Penalty Code | ||
| + | !scope="col" | Penalty Status | ||
| + | !scope="col" | Penalty Date | ||
| + | !scope="col" | Enforcement Date | ||
| + | !scope="col" | Penalty Amount | ||
| + | !scope="col" | Amount Collected | ||
| + | |- | ||
| + | |}--> | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
| − | | title = Oil and Gas | + | | title =Oil and Gas Compliance Report |
| − | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
| − | + | | date = 2019-05-20 | |
| − | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
| − | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
| − | + | == Fracking Activities == | |
| − | == | + | ==== Fracking Jobs ==== |
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Job Number | ||
| + | !scope="col" | Job Start Date | ||
| + | !scope="col" | Job End Date | ||
| + | !scope="col" | True Vertical Depth (ft) | ||
| + | !scope="col" | Total Water Volume (gal) | ||
| + | !scope="col" | Total Non-Water Volume (gal) | ||
| + | |- | ||
| + | | 1 | ||
| + | | 02/09/2014 | ||
| + | | 02/16/2014 | ||
| + | | style="text-align: right;" | 8047 | ||
| + | | style="text-align: right;" | 7,821,450.0 | ||
| + | | style="text-align: right;" | 0 | ||
| + | |- | ||
| + | |} | ||
| + | ==== Fluid Composition Data ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
| − | !scope="col" | | + | !scope="col" | Job Number |
| − | |||
| − | |||
!scope="col" | Trade Name | !scope="col" | Trade Name | ||
| + | !scope="col" | Supplier | ||
!scope="col" | Purpose | !scope="col" | Purpose | ||
| − | !scope="col" | CAS | + | !scope="col" | Ingredient Name |
| − | !scope="col" | | + | !scope="col" | CAS Number |
| + | !scope="col" | Additive Percentage by Mass | ||
| + | !scope="col" | Job Percentage by Mass | ||
| + | !scope="col" | Mass Used (lb) | ||
|- | |- | ||
| − | | | + | |- valign="top" |
| + | | rowspan="9"| 1 | ||
| + | | rowspan="1"| Hydrochloric Acid (15%) | ||
| + | | rowspan="1"| Halliburton | ||
| + | | rowspan="1"| Acidizing | ||
| Hydrochloric Acid | | Hydrochloric Acid | ||
| − | |||
| − | |||
| − | |||
| 7647-01-0 | | 7647-01-0 | ||
| − | | | + | | style="text-align: right;" | 15 |
| + | | style="text-align: right;" | 0.0257613 | ||
| + | | style="text-align: right;" | 18751.2 | ||
|- | |- | ||
| + | |- valign="top" | ||
| + | | rowspan="1"| Water | ||
| + | | rowspan="1"| Halliburton | ||
| + | | rowspan="1"| Carrier/Base Fluid | ||
| + | | Water | ||
| + | | 7732-18-5 | ||
| + | | style="text-align: right;" | 100 | ||
| + | | style="text-align: right;" | 89.6711 | ||
| + | | style="text-align: right;" | 65,270,000.0 | ||
|- | |- | ||
| − | | | + | |- valign="top" |
| + | | rowspan="1"| MC MX 5-2402 | ||
| + | | rowspan="1"| Halliburton | ||
| + | | rowspan="1"| Sodium Nitrate Brine | ||
| Sodium nitrate | | Sodium nitrate | ||
| − | |||
| − | |||
| − | |||
| 7631-99-4 | | 7631-99-4 | ||
| − | | | + | | style="text-align: right;" | 60 |
| − | | | + | | style="text-align: right;" | 0.0580182 |
| − | |- | + | | style="text-align: right;" | 42230.5 |
| − | | | ||
| − | | | ||
| − | | | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | |- | + | |- valign="top" |
| − | | | + | | rowspan="1"| BA-40L |
| + | | rowspan="1"| Halliburton | ||
| + | | rowspan="1"| Buffering agent | ||
| Potassium carbonate | | Potassium carbonate | ||
| − | |||
| − | |||
| − | |||
| 584-08-7 | | 584-08-7 | ||
| − | | | + | | style="text-align: right;" | 60 |
| + | | style="text-align: right;" | 0.00002058 | ||
| + | | style="text-align: right;" | 14.981 | ||
|- | |- | ||
| − | |- | + | |- valign="top" |
| − | | | + | | rowspan="1"| FR-66 |
| + | | rowspan="1"| Halliburton | ||
| + | | rowspan="1"| Friction reducer | ||
| Hydrotreated Petroleum Distillate | | Hydrotreated Petroleum Distillate | ||
| − | |||
| − | |||
| − | |||
| 64742-47-8 | | 64742-47-8 | ||
| − | | | + | | style="text-align: right;" | 30 |
| + | | style="text-align: right;" | 0.0522122 | ||
| + | | style="text-align: right;" | 38004.3 | ||
|- | |- | ||
| + | |- valign="top" | ||
| + | | rowspan="1"| Sand (Proppant) | ||
| + | | rowspan="1"| Halliburton | ||
| + | | rowspan="1"| Proppant | ||
| + | | Silica Substrate | ||
| + | | 14808-60-7 | ||
| + | | style="text-align: right;" | 100 | ||
| + | | style="text-align: right;" | 9.84498 | ||
| + | | style="text-align: right;" | 7,165,990.0 | ||
|- | |- | ||
| − | | | + | |- valign="top" |
| − | | | + | | rowspan="1"| LGC-36 UC |
| − | | | + | | rowspan="1"| Halliburton |
| − | | | + | | rowspan="1"| Gel |
| − | | | + | | Guar Gum, Naphtha |
| − | | | + | | 9000-30-0 |
| − | | | + | | style="text-align: right;" | 100 |
| − | |- | + | | style="text-align: right;" | 0.00350862 |
| + | | style="text-align: right;" | 2553.86 | ||
|- | |- | ||
| − | | | + | |- valign="top" |
| + | | rowspan="1"| LP-65 | ||
| + | | rowspan="1"| Halliburton | ||
| + | | rowspan="1"| Scale inhibitor | ||
| Ammonium Chloride | | Ammonium Chloride | ||
| − | |||
| − | |||
| − | |||
| 12125-02-9 | | 12125-02-9 | ||
| − | | | + | | style="text-align: right;" | 10 |
| + | | style="text-align: right;" | 0.00375265 | ||
| + | | style="text-align: right;" | 2731.49 | ||
|- | |- | ||
| − | |- | + | |- valign="top" |
| − | | | + | | rowspan="1"| SP Breaker |
| − | | | + | | rowspan="1"| Halliburton |
| − | | | + | | rowspan="1"| Breaker |
| − | | | + | | Sodium Persulfate |
| − | | | + | | 7775-27-1 |
| − | | | + | | style="text-align: right;" | 100 |
| − | | | + | | style="text-align: right;" | 0.00041076 |
| − | |- | + | | style="text-align: right;" | 298.985 |
| − | |- | ||
| − | | | ||
| − | | | ||
| − | | | ||
| − | |||
| − | |||
| − | | | ||
| − | | | ||
|- | |- | ||
|} | |} | ||
| − | For data sources see<ref>{{cite web | title = FracFocus | + | For data sources see<ref>{{cite web |
| − | == References == | + | | title =FracFocus Fracking Chemicals Database |
| − | + | | date = 2019-04-02 | |
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-06-19 }}</ref> | ||
| + | ==References== | ||
| + | <references/> | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
| − | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
| + | [[Category:FracFocus]] | ||
| Well ID: 37-059-26140 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.986367,"lon":-80.137689,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Greene | |
| Municipality: Washington Township | |
| Operator Name: EQT PROD CO | |
| Well Pad ID: 145143 | |
| Farm/Lease Name: SANDERS 591573 | |
| License Status: Active | |
| Spud Date: 06/11/2013 | |
| Permit Date: 3/26/2013 | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Latitude: 39.986367 | |
| Longitude: -80.137689 |
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2013 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2014 | EQT PROD CO | 1,661,111.00 | 216 | 0.00 | 0 | 0.00 | 0 |
| 2015 | EQT PROD CO | 1,243,658.00 | 353 | 0.00 | 0 | 0.00 | 0 |
| 2016 | EQT PROD CO | 879,893.00 | 366 | 0.00 | 0 | 0.00 | 0 |
| 2017 | EQT PROD CO | 624,094.00 | 352 | 0.00 | 0 | 0.00 | 0 |
| 2018 | EQT PROD CO | 505,925.00 | 351 | 0.00 | 0 | 0.00 | 0 |
| 2019 | EQT PROD CO | 108,929.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
| Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|
| 2013-1 | Drilling Fluid Waste (in Barrels) | 112.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013-2 | Drilling Fluid Waste (in Barrels) | 850.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013-2 | Fracing Fluid Waste (in Barrels) | 25.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
| 2013-2 | Fracing Fluid Waste (in Barrels) | 8,480.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014-1 | Drilling Fluid Waste (in Barrels) | 260.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014-1 | Fracing Fluid Waste (in Barrels) | 14,211.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014-1 | Fracturing Fluid Waste (in Tons) | 24.28 Tons | LANDFILL | 100419 |
| 2014-1 | Fracturing Fluid Waste (in Tons) | 3.76 Tons | LANDFILL | SWF 1032-WV0109 |
| 2014-1 | Produced Fluid (in Barrels) | 819.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
| 2014-1 | Produced Fluid (in Barrels) | 564.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
| 2014-1 | Produced Fluid (in Barrels) | 4,055.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014-2 | Fracing Fluid Waste (in Barrels) | 1,073.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014-2 | Produced Fluid (in Barrels) | 2,769.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
| 2014-2 | Produced Fluid (in Barrels) | 290.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
| 2014-2 | Produced Fluid (in Barrels) | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
| 2014-2 | Produced Fluid (in Barrels) | 199.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
| 2014-2 | Produced Fluid (in Barrels) | 11,800.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015-1 | Fracing Fluid Waste (in Barrels) | 1,786.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015-1 | Fracturing Fluid Waste (in Tons) | 36.00 Tons | LANDFILL | SWF 1032-WV0109 |
| 2015-1 | Produced Fluid (in Barrels) | 90.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
| 2015-1 | Produced Fluid (in Barrels) | 350.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
| 2015-1 | Produced Fluid (in Barrels) | 110.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
| 2015-1 | Produced Fluid (in Barrels) | 7,863.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015-2 | Produced Fluid (in Barrels) | 2,390.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016-1 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 706.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016-1 | Produced Fluid (in Barrels) RWC 802 | 2,363.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016-2 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 75.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
| 2016-2 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 322.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016-2 | Produced Fluid (in Barrels) RWC 802 | 1,730.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2017-01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 410.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
| 2017-01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 100.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-01 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 440.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-02 | Produced Fluid (in Barrels) RWC 802 | 210.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 410.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-03 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 110.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-04 | Produced Fluid (in Barrels) RWC 802 | 660.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-05 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
| 2017-06 | Produced Fluid (in Barrels) RWC 802 | 325.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-07 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
| 2017-07 | Produced Fluid (in Barrels) RWC 802 | 260.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
| 2017-08 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 60.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-08 | Produced Fluid (in Barrels) RWC 802 | 720.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-10 | Produced Fluid (in Barrels) RWC 802 | 65.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-11 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | REUSE (AT WELL PAD) | |
| 2017-12 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | REUSE (AT WELL PAD) | |
| 2018-01 | Produced Fluid (in Barrels) RWC 802 | 260.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
| 2018-01 | Produced Fluid (in Barrels) RWC 802 | 65.00 Bbl | REUSE (AT WELL PAD) | |
| 2018-02 | Produced Fluid (in Barrels) RWC 802 | 11.49 Bbl | INJECTION DISPOSAL WELL | 34-009-23823 |
| 2018-02 | Produced Fluid (in Barrels) RWC 802 | 34.47 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
| 2018-02 | Produced Fluid (in Barrels) RWC 802 | 22.98 Bbl | REUSE (AT WELL PAD) | |
| 2018-03 | Produced Fluid (in Barrels) RWC 802 | 11.12 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
| 2018-03 | Produced Fluid (in Barrels) RWC 802 | 11.12 Bbl | REUSE (AT WELL PAD) | |
| 2018-04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 9.29 Bbl | REUSE (AT WELL PAD) | |
| 2018-04 | Produced Fluid (in Barrels) RWC 802 | 32.76 Bbl | REUSE (AT WELL PAD) | |
| 2018-05 | Produced Fluid (in Barrels) RWC 802 | 269.71 Bbl | REUSE (AT WELL PAD) | |
| 2018-06 | Produced Fluid (in Barrels) RWC 802 | 20.01 Bbl | REUSE (AT WELL PAD) | |
| 2018-07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 55.71 Bbl | REUSE (AT WELL PAD) | |
| 2018-07 | Produced Fluid (in Barrels) RWC 802 | 42.67 Bbl | REUSE (AT WELL PAD) | |
| 2018-08 | Produced Fluid (in Barrels) RWC 802 | 8.80 Bbl | REUSE (AT WELL PAD) | |
| 2018-09 | Produced Fluid (in Barrels) RWC 802 | 10.38 Bbl | REUSE (AT WELL PAD) | |
| 2018-10 | Produced Fluid (in Barrels) RWC 802 | 8.48 Bbl | REUSE (AT WELL PAD) | |
| 2018-11 | Produced Fluid (in Barrels) RWC 802 | 0.63 Bbl | REUSE (AT WELL PAD) | |
| 2018-12 | Produced Fluid (in Barrels) RWC 802 | 40.08 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
| 2018-12 | Produced Fluid (in Barrels) RWC 802 | 63.55 Bbl | REUSE (AT WELL PAD) | |
| 2019-01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 25.00 Bbl | REUSE (AT WELL PAD) | |
| 2019-01 | Produced Fluid (in Barrels) RWC 802 | 212.37 Bbl | REUSE (AT WELL PAD) | |
| 2019-02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 8.57 Bbl | REUSE (AT WELL PAD) | |
| 2019-02 | Produced Fluid (in Barrels) RWC 802 | 46.30 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
| 2019-02 | Produced Fluid (in Barrels) RWC 802 | 54.64 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
| 2019-02 | Produced Fluid (in Barrels) RWC 802 | 9.11 Bbl | REUSE (AT WELL PAD) | |
| 2019-03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 61.43 Bbl | REUSE (AT WELL PAD) | |
| 2019-03 | Produced Fluid (in Barrels) RWC 802 | 10.14 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2173034 | Primary Facility | 06/06/2013 | Routine/Complete Inspection | No Violations Noted | Pre-operation inspection requested by the Operator on 5/30/2013. At the time of inspection the erosion and sedimentation plan was on site. All perimeter BMPs appear to installed and functioning properly. No observation of accelerated erosion or sedimentation in relation to the well pad or access road at the time of inspection. The Department suggests the Operator continue to inspect the site weekly and after significant precipitation event to ensure the stability of the site in maintained. |
| 2184980 | Primary Facility | 07/11/2013 | Drilling/Alteration | No Violations Noted | CONDUCTOR SET. WAITING FOR RIG TO SKID AND COMMENCE DRILLING OF TOP HOLE. |
| 2206187 | Primary Facility | 09/03/2013 | Drilling/Alteration | No Violations Noted | VERTICAL SECTION OF WELL DRILLED TO COMPLETION. WAITING FOR HORIZONTAL RIG TO MOVE IN AND COMPLETE DRILLING OF WELL. |
| 2213100 | Primary Facility | 10/09/2013 | Drilling/Alteration | No Violations Noted | DRILLING OF WELL COMPLETE. WELL READY FOR STIMULATION. |
| 2294914 | Primary Facility | 06/16/2014 | Routine/Complete Inspection | No Violations Noted | Well in compliance. |
| 2350925 | Primary Facility | 01/29/2015 | Routine/Complete Inspection | No Violations Noted | Well drilled, and in production. |
| 2403372 | Primary Facility | 08/28/2015 | Complaint Inspection | No Violations Noted | 14 wells drilled and equipped for production. 14 upright tanks and 7 skid tanks onsite. Id sign and e&s ok. |
| 2418796 | Primary Facility | 10/15/2015 | Routine/Complete Inspection | No Violations Noted | On 10/15/15, I conducted a routine complete inspection of the Sanders site and made the following observations: |
For data sources see[6]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 02/09/2014 | 02/16/2014 | 8047 | 7,821,450.0 | 0 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | Hydrochloric Acid (15%) | Halliburton | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0257613 | 18751.2 |
| Water | Halliburton | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 89.6711 | 65,270,000.0 | |
| MC MX 5-2402 | Halliburton | Sodium Nitrate Brine | Sodium nitrate | 7631-99-4 | 60 | 0.0580182 | 42230.5 | |
| BA-40L | Halliburton | Buffering agent | Potassium carbonate | 584-08-7 | 60 | 0.00002058 | 14.981 | |
| FR-66 | Halliburton | Friction reducer | Hydrotreated Petroleum Distillate | 64742-47-8 | 30 | 0.0522122 | 38004.3 | |
| Sand (Proppant) | Halliburton | Proppant | Silica Substrate | 14808-60-7 | 100 | 9.84498 | 7,165,990.0 | |
| LGC-36 UC | Halliburton | Gel | Guar Gum, Naphtha | 9000-30-0 | 100 | 0.00350862 | 2553.86 | |
| LP-65 | Halliburton | Scale inhibitor | Ammonium Chloride | 12125-02-9 | 10 | 0.00375265 | 2731.49 | |
| SP Breaker | Halliburton | Breaker | Sodium Persulfate | 7775-27-1 | 100 | 0.00041076 | 298.985 |
For data sources see[7]