If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-059-25650 | | Well ID: 37-059-25650 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="14" | {{#display_map: 39.961542, -80.030747 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | Municipality: [[Jefferson Township, | + | | State: Pennsylvania |
+ | |- | ||
+ | | County: [[Greene_County,_Pennsylvania|Greene]] | ||
+ | |- | ||
+ | | Municipality: [[Jefferson Township,_Greene_County,_Pennsylvania|Jefferson Township]] | ||
|- | |- | ||
| Operator Name: [[CHEVRON APPALACHIA LLC]] | | Operator Name: [[CHEVRON APPALACHIA LLC]] | ||
|- | |- | ||
− | | Well Pad ID: [[ | + | | Well Pad ID: [[148678]] |
|- | |- | ||
| Farm/Lease Name: KIEFFER UNIT 3H | | Farm/Lease Name: KIEFFER UNIT 3H | ||
|- | |- | ||
− | | | + | | License Status: Active |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | Spud Date: 03/07/2011 |
|- | |- | ||
− | | | + | | Permit Date: 12/27/2010 |
|- | |- | ||
− | | Well | + | | Unconventional Well: Y |
|- | |- | ||
− | | | + | | Configuration: Horizontal Well |
|- | |- | ||
− | | Latitude: 39. | + | | Latitude: 39.961542 |
|- | |- | ||
| Longitude: -80.030747 | | Longitude: -80.030747 | ||
− | |||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator Name |
− | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
− | !scope="col" | | + | !scope="col" | Gas Production Days |
− | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
− | !scope="col" | | + | !scope="col" | Oil Production Days |
− | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
+ | !scope="col" | Water Production Days | ||
|- | |- | ||
− | | 2010 | + | | 2010 |
− | | style="text-align:right;" | 0. | + | | [[ATLAS RESOURCES LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2011 | ||
+ | | [[ATLAS RESOURCES LLC]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2012 |
− | | style="text-align:right;" | | + | | [[CHEVRON APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 374,784.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 153 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2013 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 577,326.00 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2014 |
− | | style="text-align:right;" | | + | | [[CHEVRON APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 345,543.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 334 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2015 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 248,947.00 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2016 |
− | | style="text-align:right;" | | + | | [[CHEVRON APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 207,116.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 366 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2017 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 176,516.00 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2018 |
− | | style="text-align:right;" | | + | | [[CHEVRON APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 146,938.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 334 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[CHEVRON APPALACHIA LLC]] | |
− | + | | style="text-align: right;" | 36,334.00 | |
− | + | | style="text-align: right;" | 90 | |
− | + | | style="text-align: right;" | 0.00 | |
− | + | | style="text-align: right;" | 0 | |
− | + | | style="text-align: right;" | 0.00 | |
− | + | | style="text-align: right;" | 0 | |
− | |||
− | |||
− | | | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Waste Type |
− | !scope="col" | | + | !scope="col" | Quantity |
− | !scope="col" | | + | !scope="col" | Disposal Method |
− | !scope="col" | | + | !scope="col" | Waste Facility ID |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-2 | | 2011-2 | ||
− | | | + | | Drilling Fluid Waste (in Barrels) |
− | | style="text-align:right;" | 7. | + | | style="text-align: right;" | 7,475.00 Bbl |
− | |||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-2 | | 2011-2 | ||
− | | | + | | Fracing Fluid Waste (in Barrels) |
− | | style="text-align:right;" | 6. | + | | style="text-align: right;" | 6,435.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2012-1 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 1,840.00 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | WMGR123SW001 | ||
+ | |- | ||
+ | | 2012-1 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 2,430.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
+ | |- | ||
+ | | 2012-2 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 403.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
+ | | 2012-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 1,372.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2013-1 |
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,831.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2013-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 1,205.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
+ | |- | ||
+ | | 2014-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 631.67 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | |- | + | | 2014-2 |
− | | | + | | Fracing Fluid Waste (in Barrels) |
− | + | | style="text-align: right;" | 16.67 Bbl | |
− | | style="text-align:right;" | | + | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) |
− | |||
− | | | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 465.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2015-1 |
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 343.33 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2015-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 363.33 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
+ | |- | ||
+ | | 2016-1 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 310.67 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
+ | | 2016-2 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 268.68 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | WMGR123SW019 | ||
|- | |- | ||
− | | | + | | 2016-2 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 33.33 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | | + | |- |
− | | | + | | 2017-01 |
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 24.67 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2017-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 43.77 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2017-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 3,220.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2017-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 41.67 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-157-25511 | ||
|- | |- | ||
− | | | + | | 2017-08 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 36.67 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | REUSE | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2017-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 68.33 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2017-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
|- | |- | ||
+ | | 2018-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 76.33 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
|- | |- | ||
− | | | + | | 2018-02 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 73.33 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | REUSE | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2018-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 16.67 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2018-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 33.33 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2018-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2018-07 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 38.33 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | REUSE | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2018-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 35.00 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
+ | |- | ||
+ | | 2018-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 36.67 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
|- | |- | ||
+ | | 2018-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 33.33 Bbl | ||
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2019-01 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 80.00 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | | + | | |
− | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | |- | + | | 2019-03 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | + | | style="text-align: right;" | 80.00 Bbl | |
− | | style="text-align:right;" | | + | | REUSE (AT WELL PAD) |
− | |||
− | | REUSE | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Waste Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Inspection Data == | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Inspection ID |
− | !scope="col" | | + | !scope="col" | Inspection Category |
− | !scope="col" | | + | !scope="col" | Inspection Date |
− | !scope="col" | | + | !scope="col" | Inspection Type |
− | !scope="col" | | + | !scope="col" | Inspection Result |
− | + | !scope="col" | Inspection Comments | |
− | !scope="col" | | ||
|- | |- | ||
| 1964159 | | 1964159 | ||
− | | | + | | Primary Facility |
+ | | 04/04/2011 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 1970195 | | 1970195 | ||
− | | | + | | Primary Facility |
+ | | 03/09/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1974942 | | 1974942 | ||
− | | | + | | Primary Facility |
+ | | 03/29/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The Operator is currently drilling top-hole on site. The site contains 1 drilling pit at this time. The Operator plans on constructing another pit and 2 additional impoundments for frac water. The pit that is half completed on site does contain water and groundwater is a concern. The pit/impoundments need to be constructed 20 inches above the seasonal high groundwater table. The Department may want to observe the pit that is being used at this time to hold cuttings after the liner is removed to be sure groundwater was not impacted. | | The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The Operator is currently drilling top-hole on site. The site contains 1 drilling pit at this time. The Operator plans on constructing another pit and 2 additional impoundments for frac water. The pit that is half completed on site does contain water and groundwater is a concern. The pit/impoundments need to be constructed 20 inches above the seasonal high groundwater table. The Department may want to observe the pit that is being used at this time to hold cuttings after the liner is removed to be sure groundwater was not impacted. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1974962 | | 1974962 | ||
− | | | + | | Primary Facility |
+ | | 04/01/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The Operator is currently drilling top-hole on site. The Department met on site with the Operator and a Gateway Engineer to discuss the ESCGP-1 and the impoundment. The Engineer was on site to make sure the contractors were following the construction standards of 3:1 slopes and also checking the 8 inch lifts. The contractors were installing drains on site so the springs did no impact the well pad. The Department also mentioned the drill pits and the concern that they may be close to the seasonal high groundwater table. | | The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The Operator is currently drilling top-hole on site. The Department met on site with the Operator and a Gateway Engineer to discuss the ESCGP-1 and the impoundment. The Engineer was on site to make sure the contractors were following the construction standards of 3:1 slopes and also checking the 8 inch lifts. The contractors were installing drains on site so the springs did no impact the well pad. The Department also mentioned the drill pits and the concern that they may be close to the seasonal high groundwater table. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2001312 | | 2001312 | ||
− | | | + | | Primary Facility |
+ | | 05/17/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 2027493 | | 2027493 | ||
− | | | + | | Primary Facility |
+ | | 09/06/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 2036447 | | 2036447 | ||
− | | | + | | Primary Facility |
+ | | 01/09/2012 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2120626 | | 2120626 | ||
− | | | + | | Primary Facility |
+ | | 11/15/2012 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| Wells drilled and in production. Site restored and greater than 70% growth. Site in overall good condition. | | Wells drilled and in production. Site restored and greater than 70% growth. Site in overall good condition. | ||
+ | |- | ||
+ | | 2195702 | ||
+ | | Primary Facility | ||
+ | | 08/12/2013 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | Routine inspection. Well cmpliant at time of inspection. | ||
+ | |- | ||
+ | | 2314873 | ||
+ | | Primary Facility | ||
+ | | 06/19/2014 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | On 9/16/2014, I performed an inspection of Chevron Kieffer well pad site. The site is located in Dunkard Twp., Greene County. The inspection was performed as a restoration inspection and request by operator for a termination of the ESCGP permit. | ||
+ | |- | ||
+ | | 2318076 | ||
+ | | Primary Facility | ||
+ | | 08/28/2014 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | Well in production. Well in compliance. | ||
+ | |- | ||
+ | | 2488227 | ||
+ | | Primary Facility | ||
+ | | 2016-05-19 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | HORIZONTAL MARCELLUS, Routine Inspection all looks good. | ||
+ | |- | ||
+ | | 2509265 | ||
+ | | Primary Facility | ||
+ | | 2016-08-09 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
| | | | ||
+ | |||
+ | On 08/09/16 at approximately 1430 hours I conducted a routine complete inspection of the Chevron Appalachia LLC Kieffer well site. The Act 9 sign was in place and all required documents were present at the site. The well pad was fenced, gated, and locked at the time of inspection. | ||
+ | |||
+ | Chevron had recently submitted a minor modification and Environmental Engineering Specialist Mohamed Sam found that the last major modification for the site was approved on 12/21/2010. As a result, the ESCGP-1 expired on 12/20/2015 with no record of an extension being requested or approved. An NOT was completed by WQS Ben Dillie on 10/09/2014 and in the report Dillie indicated the NOT was denied due to the well pad having not been reclaimed to post construction design. A violation of 102.7(c) has occurred for failure to terminate or renew the ESCGP. | ||
+ | |||
+ | An overlay exhibit submitted with the minor modification shows that the access road was not built in the permitted location. This is a violation of 102.5(m)(4). Additionally, an u | ||
+ | |- | ||
+ | |} | ||
+ | <!--==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Violation Date | ||
+ | !scope="col" | Date Resolved | ||
+ | !scope="col" | Violation Code | ||
+ | !scope="col" | Violation Type | ||
+ | !scope="col" | Violation Comments | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Penalties Applied ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Penalty ID | ||
+ | !scope="col" | Penalty Code | ||
+ | !scope="col" | Penalty Status | ||
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
+ | |- | ||
+ | |}--> | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Compliance Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 01/18/2012 | ||
+ | | 01/18/2012 | ||
+ | | style="text-align: right;" | 6785.00 | ||
+ | | style="text-align: right;" | 2,592,713.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="12"| 1 | ||
+ | | rowspan="1"| Iron Control A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Iron Control | ||
+ | | Ethylene glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.00659000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| Biocide EC 6116A | ||
+ | | rowspan="3"| Nalco | ||
+ | | rowspan="3"| Biocide | ||
+ | | 2,2-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.00692000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Polyethylene glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 60.00 | ||
+ | | style="text-align: right;" | 0.01 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5.00 | ||
+ | | style="text-align: right;" | 0.00115000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| GBL | ||
+ | | rowspan="1"| Clearwater International | ||
+ | | rowspan="1"| Gel Breaker | ||
+ | | Ethylene glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 60.00 | ||
+ | | style="text-align: right;" | 0.00002000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| CMHPG | ||
+ | | rowspan="1"| Ashland | ||
+ | | rowspan="1"| Water Viscosifier | ||
+ | | Carboxymethylhydroxyporoyl guar blend | ||
| | | | ||
− | | | + | | style="text-align: right;" | 100.00 |
+ | | style="text-align: right;" | 0.00127000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Unislik ST 50 | ||
+ | | rowspan="1"| CESI Chemical | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Distillates, petroleum, hydrotreated light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.03 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Scale Inhibitor A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.00684000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| ASP 900 | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Ammonium sulfate | ||
+ | | 7783-20-2 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 7.5 Hcl Acid | ||
+ | | rowspan="1"| | ||
+ | | rowspan="1"| Used to open perfs | ||
+ | | Hydrochloric acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 7.50 | ||
+ | | style="text-align: right;" | 0.26 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| Proppant (lbs) |
− | | | + | | rowspan="1"| |
− | | | + | | rowspan="1"| Proppant |
+ | | | ||
| | | | ||
+ | | style="text-align: right;" | 10.05 | ||
+ | | style="text-align: right;" | 11.20 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Clean Volume (gals) | ||
+ | | rowspan="1"| | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
| | | | ||
| | | | ||
+ | | style="text-align: right;" | 89.95 | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = | + | | title =FracFocus Fracking Chemicals Database |
− | + | | date = 2019-04-02 | |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | accessdate = 2019-06-19 }}</ref> |
− | | accessdate = | + | ==References== |
− | == References == | + | <references/> |
− | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
+ | [[Category:FracFocus]] |
Well ID: 37-059-25650 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.961542,"lon":-80.030747,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Jefferson Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 148678 | |
Farm/Lease Name: KIEFFER UNIT 3H | |
License Status: Active | |
Spud Date: 03/07/2011 | |
Permit Date: 12/27/2010 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.961542 | |
Longitude: -80.030747 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | ATLAS RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | ATLAS RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 374,784.00 | 153 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 577,326.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 345,543.00 | 334 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 248,947.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 207,116.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 176,516.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 146,938.00 | 334 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 36,334.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2011-2 | Drilling Fluid Waste (in Barrels) | 7,475.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2011-2 | Fracing Fluid Waste (in Barrels) | 6,435.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-1 | Fracing Fluid Waste (in Barrels) | 1,840.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012-1 | Fracing Fluid Waste (in Barrels) | 2,430.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-2 | Fracing Fluid Waste (in Barrels) | 403.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-2 | Produced Fluid (in Barrels) | 1,372.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-1 | Produced Fluid (in Barrels) | 1,831.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-2 | Produced Fluid (in Barrels) | 1,205.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Produced Fluid (in Barrels) | 631.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-2 | Fracing Fluid Waste (in Barrels) | 16.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-2 | Produced Fluid (in Barrels) | 465.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-1 | Produced Fluid (in Barrels) | 343.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-2 | Produced Fluid (in Barrels) | 363.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 310.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 268.68 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 24.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 43.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 3,220.00 Bbl | REUSE (AT WELL PAD) | |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 41.67 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 68.33 Bbl | REUSE (AT WELL PAD) | |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 76.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | REUSE (AT WELL PAD) | |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 16.67 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 38.33 Bbl | REUSE (AT WELL PAD) | |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 35.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 80.00 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 80.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1964159 | Primary Facility | 04/04/2011 | Drilling/Alteration | No Violations Noted | |
1970195 | Primary Facility | 03/09/2011 | Routine/Complete Inspection | No Violations Noted | |
1974942 | Primary Facility | 03/29/2011 | Routine/Complete Inspection | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The Operator is currently drilling top-hole on site. The site contains 1 drilling pit at this time. The Operator plans on constructing another pit and 2 additional impoundments for frac water. The pit that is half completed on site does contain water and groundwater is a concern. The pit/impoundments need to be constructed 20 inches above the seasonal high groundwater table. The Department may want to observe the pit that is being used at this time to hold cuttings after the liner is removed to be sure groundwater was not impacted. |
1974962 | Primary Facility | 04/01/2011 | Routine/Complete Inspection | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The Operator is currently drilling top-hole on site. The Department met on site with the Operator and a Gateway Engineer to discuss the ESCGP-1 and the impoundment. The Engineer was on site to make sure the contractors were following the construction standards of 3:1 slopes and also checking the 8 inch lifts. The contractors were installing drains on site so the springs did no impact the well pad. The Department also mentioned the drill pits and the concern that they may be close to the seasonal high groundwater table. |
2001312 | Primary Facility | 05/17/2011 | Routine/Complete Inspection | No Violations Noted | |
2027493 | Primary Facility | 09/06/2011 | Routine/Complete Inspection | No Violations Noted | |
2036447 | Primary Facility | 01/09/2012 | Routine/Complete Inspection | No Violations Noted | |
2120626 | Primary Facility | 11/15/2012 | Routine/Complete Inspection | No Violations Noted | Wells drilled and in production. Site restored and greater than 70% growth. Site in overall good condition. |
2195702 | Primary Facility | 08/12/2013 | Routine/Complete Inspection | No Violations Noted | Routine inspection. Well cmpliant at time of inspection. |
2314873 | Primary Facility | 06/19/2014 | Routine/Complete Inspection | No Violations Noted | On 9/16/2014, I performed an inspection of Chevron Kieffer well pad site. The site is located in Dunkard Twp., Greene County. The inspection was performed as a restoration inspection and request by operator for a termination of the ESCGP permit. |
2318076 | Primary Facility | 08/28/2014 | Routine/Complete Inspection | No Violations Noted | Well in production. Well in compliance. |
2488227 | Primary Facility | 2016-05-19 | Routine/Complete Inspection | No Violations Noted | HORIZONTAL MARCELLUS, Routine Inspection all looks good. |
2509265 | Primary Facility | 2016-08-09 | Routine/Complete Inspection | No Violations Noted |
On 08/09/16 at approximately 1430 hours I conducted a routine complete inspection of the Chevron Appalachia LLC Kieffer well site. The Act 9 sign was in place and all required documents were present at the site. The well pad was fenced, gated, and locked at the time of inspection. Chevron had recently submitted a minor modification and Environmental Engineering Specialist Mohamed Sam found that the last major modification for the site was approved on 12/21/2010. As a result, the ESCGP-1 expired on 12/20/2015 with no record of an extension being requested or approved. An NOT was completed by WQS Ben Dillie on 10/09/2014 and in the report Dillie indicated the NOT was denied due to the well pad having not been reclaimed to post construction design. A violation of 102.7(c) has occurred for failure to terminate or renew the ESCGP. An overlay exhibit submitted with the minor modification shows that the access road was not built in the permitted location. This is a violation of 102.5(m)(4). Additionally, an u |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 01/18/2012 | 01/18/2012 | 6785.00 | 2,592,713.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Iron Control A | Nalco | Iron Control | Ethylene glycol | 107-21-1 | 30.00 | 0.00659000 | |
Biocide EC 6116A | Nalco | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00692000 | ||
Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | |||||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00115000 | |||||
GBL | Clearwater International | Gel Breaker | Ethylene glycol | 107-21-1 | 60.00 | 0.00002000 | ||
CMHPG | Ashland | Water Viscosifier | Carboxymethylhydroxyporoyl guar blend | 100.00 | 0.00127000 | |||
Unislik ST 50 | CESI Chemical | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.03 | ||
Scale Inhibitor A | Nalco | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00684000 | ||
ASP 900 | Nalco | Friction Reducer | Ammonium sulfate | 7783-20-2 | 30.00 | |||
7.5 Hcl Acid | Used to open perfs | Hydrochloric acid | 7647-01-0 | 7.50 | 0.26 | |||
Proppant (lbs) | Proppant | 10.05 | 11.20 | |||||
Clean Volume (gals) | Carrier/Base Fluid | 89.95 | 100.00 |
For data sources see[7]