X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-129-28804"

m
m
Line 391: Line 391:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
 
  | accessdate = 2015-05-27 }}</ref>
 
  | accessdate = 2015-05-27 }}</ref>
 +
[[Category:Has Chemical Data]]
 +
==Chemical Data==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | HF Fluid Concentration
 +
!scope="col" | Ingredient
 +
!scope="col" | Additive Concentration
 +
!scope="col" | Trade Name
 +
!scope="col" | Purpose
 +
!scope="col" | CAS number
 +
!scope="col" | Supplier
 +
|-
 +
| 0.00075576
 +
| Ethylene Glycol
 +
| 30.0
 +
| Scale Inhibitor A
 +
| Scale Inhibitor
 +
| 107-21-1
 +
| Nalco
 +
|-
 +
|-
 +
| 0.00340537
 +
| Hydrotreated Light Distillite
 +
| 30.0
 +
| Unislik ST 50
 +
| Friction Reducer
 +
| 64742-47-8
 +
| CESI
 +
|-
 +
|-
 +
| 0.00012821
 +
| Dibromoacetonitrile
 +
| 5.0
 +
| EC 6116a
 +
| Biocide
 +
| 3252-43-5
 +
| Nalco
 +
|-
 +
|-
 +
| 30.0
 +
| 1
 +
| 10222.0
 +
| EC 6116a
 +
| Biocide
 +
|  1-Dibromo-3-nitrilo
 +
| Nalco
 +
|-
 +
|-
 +
| 0.00153848
 +
| Polyethylene Glycol
 +
| 60.0
 +
| EC 6116a
 +
| Biocide
 +
| 25322-68-3
 +
| Nalco
 +
|-
 +
|-
 +
| 0.00954237
 +
| Hydrochloric Acid
 +
| 15.0
 +
| 15% Hcl Acid
 +
| Used to open perfs
 +
| 7647-01-0
 +
| Reagent/PPG
 +
|-
 +
|-
 +
| 8.68e-06
 +
| Ethylene Glycol
 +
| 60.0
 +
| GBL
 +
| Gel Breaker
 +
| 107-21-1
 +
| Clearwater
 +
|-
 +
|-
 +
| 0.00071283
 +
| Ethylene Glycol
 +
| 30.0
 +
| Iron Control A
 +
| Iron Control
 +
| 107-21-1
 +
| Nalco
 +
|-
 +
|-
 +
| 91.33
 +
| H20
 +
| 100.0
 +
| Clean Volume
 +
|  LLC
 +
| 7732-18-5
 +
| Chevron Applachia
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web | title = FracFocus Chemical Disclosure Registry |publisher = [http://www.fracfocusdata.org/DisclosureSearch/]| date = 2015-08-10 | url = http://wellwiki.org/wiki/Well_Chemicals_Data_Sources | accessdate = 2015-08-10 }}</ref>
 
== References ==
 
== References ==
 
{{reflist}}
 
{{reflist}}
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Wells]]
 
[[Category:Wells]]

Revision as of 20:28, 19 August 2015

Well Details

Well ID: 37-129-28804
Loading map...
County: Westmoreland
Municipality: South Huntingdon Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 149234
Farm/Lease Name: SABATINE-SMOUSE UNIT 1H
First Permit Date: 2012-12-07
Last Permit Date: 2012-12-07
Spud Date: 2013-01-24
Unconventional: Yes
Horizontal: Yes
Well Status: ACTIVE
Violations: 0
Latitude: 40.213222
Longitude: -79.706452

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2013-1 0.0 0.0 0.0 0.0 0.0 0.0
2013-2 0.0 0.0 0.0 0.0 0.0 0.0
2014-1 120656.0 28.0 0.0 0.0 0.0 0.0
2014-2 500566.0 184.0 0.0 0.0 0.0 0.0
2015-02 53203.0 28.0 0.0 0.0 0.0 0.0
2015-01 62388.0 31.0 0.0 0.0 0.0 0.0
2015-03 56816.0 31.0 0.0 0.0 0.0 0.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2013-2 DRILL CUTTINGS 983.76 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2013-2 DRILLING FLUID WASTE 6.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2013-2 FRACING FLUID WASTE 1.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 DRILL CUTTINGS 1.25 Tons LANDFILL 100592 SOUTH HILLS LANDFILL SOUTH HILLS PA
2014-1 FLOWBACK FRACTURING SAND 31.33 Tons LANDFILL 100172 ARDEN LANDFILL WASHINGTON PA
2014-1 FRACING FLUID WASTE 12.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 FRACING FLUID WASTE 1.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-2 FLOWBACK FRACTURING SAND 9.05 Tons LANDFILL 100663 KELLEY RUN LANDFILL ELIZABETH PA
2014-2 FLOWBACK FRACTURING SAND 86.66 Tons RESIDUAL WASTE TRANSFER FACILITY MID074259565 US ECOLOGY DETROIT MI
2014-2 FRACING FLUID WASTE 25.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-2 FRACING FLUID WASTE 2.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001 RONCO WASTE PROCESSING FACILITY MASONTOWN PA
2014-2 PRODUCED FLUID 1.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
2134599 2013-01-24 No Violations Noted Horiaontal Marcellus

Rocky Mountain Drilling getting set up to spud.

2134656 2013-01-25 No Violations Noted Horiaontal Marcellus

Rocky Mountain Drilling setting cellar and conductor.

2148871 2013-03-18 No Violations Noted E&S inspection. Blue-White water found in the drill cuttyings pit.
2164816 2013-04-23 No Violations Noted 4/23/2013 keane rig drilling on the 3H.
2166017 2013-05-13 Pending At the time of inspection the drill rig was onsite and placed on containment. The erosion and sedimentation plan was onsite, however the department notes several areas surrounding the well pad, on the fill side of the pad that need routine maintenance, specifically regraded seeded and mulched. the Department observed multiple areas that accelerated erosion cut channels and is transporting sediment toward the LOD and perimeter controls. The perimeter controls appear to sound however the areas contributing to the accelerated erosion are in need of attention. The Department suggest the Operator address the erosion channels and regrade, seed and mulch the affected areas. The various pit located onsite appear to be in sound condition and appear to have the required 2' of freeboard. The Department also suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site maintained.
2166019 2013-05-14 Pending Follow up inpsection and meeting onsite with Operator in response to phone call regarding the previous days inspection. The Operator and Department inspected the site and the Operator agreed to address the affected areas. The Department notes that the Operator request of a two week time frame to begin work bacause the issues noted were currently not in danger of over topping permiter BMPs. The Department aggreed to a two week time frame and request a phone call notification the day work would begin.
2167512 2013-05-14 No Violations Noted 5/14/2013 Keane rig skidding from 2-H
2189370 2013-07-18 No Violations Noted 7/18/2013 Keane rig drilling on the 2H well.
2194944 2013-08-06 No Violations Noted 8/6/2013 moving rig off of pad.
2216367 2013-10-24 No Violations Noted At the time of inspection the well was in the process of bring stimulated. The E&S plan was onsite and appeared to be installed as outlined in the plan. No sign of accelerated erosion and sedimentation in relation to the well pad or access road at the time of inspection. The Department notes that the drill pit located onsite has been back filled and the stock pile from which the material came to backfill the pit has been hydro seeded and appears to be stable. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2228545 2013-11-11 No Violations Noted At the time of inspection the well was stimulated. The E&S plan was onsite and appeared to be installed as outlined in the plan. No sign of accelerated erosion and sedimentation in relation to the well pad or access road at the time of inspection. The Department also suggests the Operator add the approved OG071 to the mail box on site. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure the stability of the site is maintained.
2326218 2014-11-25 No Violations Noted At the time of inspection well appeared to be drilled

For data sources see[3]

Chemical Data

HF Fluid Concentration Ingredient Additive Concentration Trade Name Purpose CAS number Supplier
0.00075576 Ethylene Glycol 30.0 Scale Inhibitor A Scale Inhibitor 107-21-1 Nalco
0.00340537 Hydrotreated Light Distillite 30.0 Unislik ST 50 Friction Reducer 64742-47-8 CESI
0.00012821 Dibromoacetonitrile 5.0 EC 6116a Biocide 3252-43-5 Nalco
30.0 1 10222.0 EC 6116a Biocide 1-Dibromo-3-nitrilo Nalco
0.00153848 Polyethylene Glycol 60.0 EC 6116a Biocide 25322-68-3 Nalco
0.00954237 Hydrochloric Acid 15.0 15% Hcl Acid Used to open perfs 7647-01-0 Reagent/PPG
8.68e-06 Ethylene Glycol 60.0 GBL Gel Breaker 107-21-1 Clearwater
0.00071283 Ethylene Glycol 30.0 Iron Control A Iron Control 107-21-1 Nalco
91.33 H20 100.0 Clean Volume LLC 7732-18-5 Chevron Applachia

For data sources see[4]