If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 34-167-27924 | | Well ID: 34-167-27924 | ||
− | | style="height=100%; align=center" rowspan="15" | {{#display_map: 39. | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 39.54976646, -81.50614406 | width=100% | height=100% }} |
|- | |- | ||
− | | County: | + | | County: [[Washington County, Ohio|Washington]] |
|- | |- | ||
− | | Municipality: | + | | Municipality: |
|- | |- | ||
− | | Operator Name: | + | | Operator Name: [[BENATTY CORP |
+ | ]] | ||
|- | |- | ||
− | | Well Pad ID: | + | | Well Pad ID: |
|- | |- | ||
− | | Farm/Lease Name: | + | | Farm/Lease Name: |
|- | |- | ||
− | | First Permit Date: | + | | First Permit Date: |
|- | |- | ||
− | | Last Permit Date: | + | | Last Permit Date: |
|- | |- | ||
| Spud Date: 1985-01-24 | | Spud Date: 1985-01-24 | ||
|- | |- | ||
− | | Unconventional: | + | | Unconventional: No |
|- | |- | ||
− | | | + | | Configuration: Vertical |
|- | |- | ||
− | | Producing | + | | Well Status: Producing |
|- | |- | ||
− | | Violations: | + | | Violations: 0 |
|- | |- | ||
− | | Latitude: 39. | + | | Latitude: 39.54976646 |
|- | |- | ||
− | | Longitude: -81. | + | | Longitude: -81.50614406 |
|- | |- | ||
|} | |} | ||
Line 43: | Line 44: | ||
!scope="col" | OIL QUANTITY | !scope="col" | OIL QUANTITY | ||
!scope="col" | OIL PRODUCTION DAYS | !scope="col" | OIL PRODUCTION DAYS | ||
+ | |- | ||
+ | | 1986-0 | ||
+ | | style="text-align:right;" | 30418.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1987-0 | ||
+ | | style="text-align:right;" | 17917.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1988-0 | ||
+ | | style="text-align:right;" | 10059.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1989-0 | ||
+ | | style="text-align:right;" | 6780.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1990-0 | ||
+ | | style="text-align:right;" | 4771.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1991-0 | ||
+ | | style="text-align:right;" | 3026.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1992-0 | ||
+ | | style="text-align:right;" | 2537.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1993-0 | ||
+ | | style="text-align:right;" | 2080.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1994-0 | ||
+ | | style="text-align:right;" | 1745.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1995-0 | ||
+ | | style="text-align:right;" | 2297.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1996-0 | ||
+ | | style="text-align:right;" | 81.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1998-0 | ||
+ | | style="text-align:right;" | 198.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2003-0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2004-0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2005-0 | ||
+ | | style="text-align:right;" | 145.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2006-0 | ||
+ | | style="text-align:right;" | 658.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2007-0 | ||
+ | | style="text-align:right;" | 440.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2008-0 | ||
+ | | style="text-align:right;" | 961.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2009-0 | ||
+ | | style="text-align:right;" | 211.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2010-0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2011-0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2012-0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2013-0 | ||
+ | | style="text-align:right;" | 16.0 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2014-0 | ||
+ | | style="text-align:right;" | 435.0 | ||
+ | | style="text-align:right;" | 365.0 | ||
+ | | | ||
+ | | | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 365.0 | ||
+ | |- | ||
|} | |} | ||
− | + | For data sources see<ref>{{cite web | |
− | + | | title = Ohio Department of Natural Resources RBDMS | |
− | + | | publisher = [http://oilandgas.ohiodnr.gov/] | |
− | + | | date = 2015-06-19 | |
− | + | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production | |
− | + | | accessdate = 2015-06-20 }}</ref> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
== Inspection Data == | == Inspection Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 64: | Line 275: | ||
!scope="col" | VIOLATION ID | !scope="col" | VIOLATION ID | ||
!scope="col" | VIOLATION CODE | !scope="col" | VIOLATION CODE | ||
− | !scope="col" | | + | !scope="col" | VIOLATION COMMENT |
|- | |- | ||
| -1041193210 | | -1041193210 | ||
| 2010-10-04 | | 2010-10-04 | ||
− | | | + | | |
| Inspection this day found well with jack, valves shut. ID's at tank, no chart in meter. | | Inspection this day found well with jack, valves shut. ID's at tank, no chart in meter. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1041193210 |
− | | | + | | 2010-10-04 |
− | | | + | | |
− | + | | Inspection this day found well with jack, valves shut. ID's at tank, no chart in meter. | |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1041193210 |
− | | | + | | 2010-10-04 |
− | | | + | | |
− | + | | Inspection this day found well with jack, valves shut. ID's at tank, no chart in meter. | |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | | + | | 1090647921 |
− | | | + | | 2006-03-16 |
− | | | + | | |
− | + | | Well still was producing - had an NOV against it and not certain of it's status. | |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | 1193106680 |
− | | | + | | 2014-11-18 |
− | | | + | | |
− | | | + | | Upon inspection, it was observed that this well is now equipped for production and is producing. A new counterweight stack and electric motor have been fitted on the pumping unit and there is newly ran electrical service to the motor. The valve on the 2 production tubing is in the open position and is running to a mechanical separator and into a 210 bbl production tank. There is a significant gas leak on a 1.25 plastic flow line near the mechanical separator. I spoke with Mr. Carl West over the phone and told him about the leak. I also told Mr. West that I would write the compliance notice off for this well if he fixes the leak and posts ID's at the production tank and the well head. Mr. West stated he would have the leak fixed and new ID's up by the end of the week. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1202961335 |
− | | | + | | 2003-08-14 |
− | | | + | | |
− | | Inspection this day found no change | + | | Inspection this day found well in violation, not producing, gas venting from well due to equipment failure, landowner complaint 12/6/2004 - no change - well still not producing - 2 rolls of poly line pipe laying by the well - guys have said they are having trouble getting into a line - EOG has line but won't let them in |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1317710532 |
− | | | + | | 2011-10-24 |
− | | | + | | |
− | | | + | | FOLLOW UP TO NOV # 1319537965 Inspection this day found well is idle. It was in a similar state when I last visited site. This well is equipped with a pumping unit. There is no meter in the separator/meter run and no production has been reported since 2009. No identification is posted at either the well or the tank battery. I met with landowner, who was questioning the wells status. Owner must produce, plug or place this well in Temporary Inactive status and post the proper identification. |
− | + | | | |
− | + | | | |
− | + | | | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | | ||
− | | | ||
|- | |- | ||
|- | |- | ||
| 1319537965 | | 1319537965 | ||
| 2011-10-24 | | 2011-10-24 | ||
− | | | + | | |
| Inspection this day found well is idle. It was in a similar state when I last visited site. This well is equipped with a pumping unit. There is no meter in the separator/meter run and no production has been reported since 2009. No identification is posted at either the well or the tank battery. I met with landowner, who was questioning the wells status. Owner must produce, plug or place this well in Temporary Inactive status and post the proper identification. | | Inspection this day found well is idle. It was in a similar state when I last visited site. This well is equipped with a pumping unit. There is no meter in the separator/meter run and no production has been reported since 2009. No identification is posted at either the well or the tank battery. I met with landowner, who was questioning the wells status. Owner must produce, plug or place this well in Temporary Inactive status and post the proper identification. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | -1372012502 |
− | | | + | | 2003-07-25 |
− | | | + | | |
− | | Inspection this day found well | + | | Inspection this day found well not producing, not hooked into sales line, leaking gas from 4 1/2 casing at collar? Called operator - told him of problem and told him to fix immediately - said he would. Landowner felt he was in no immediate danger but had been occuring for some time and only getting worse. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1407360428 | | 1407360428 | ||
| 2014-08-06 | | 2014-08-06 | ||
− | | | + | | |
| Upon inspection, it was observed that no changes have been made to this well location since the last inspection on 6/10/2014. The pumping unit still has no counterweights and there is no power run to the electric motor. The valve on the production tubing is in the closed position, and the valve on the annulus of the tubing is open and supplying domestic gas. I will contact Mr. Carl West and inquire about plans for working on this well. | | Upon inspection, it was observed that no changes have been made to this well location since the last inspection on 6/10/2014. The pumping unit still has no counterweights and there is no power run to the electric motor. The valve on the production tubing is in the closed position, and the valve on the annulus of the tubing is open and supplying domestic gas. I will contact Mr. Carl West and inquire about plans for working on this well. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1428128611 | | 1428128611 | ||
| 2003-08-07 | | 2003-08-07 | ||
− | | | + | | |
− | | Inspection this day found well not fixed - had a | + | | Inspection this day found well not fixed - had a strap put around the collar at leak but still leaking just as bad or worse. Talked with landowner and told him to keep me informed of status or any worsening. Called Operator and told him it MUST be fixed correctly immediately. Operator came out on 8/8/2003 and tied well into line, but still found it leaking at meter run - Triad knows nothing about it going into their line. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1448522022 | ||
+ | | 2014-12-03 | ||
+ | | | ||
+ | | Upon inspection, it was obserevd that this well is not being used for annular disposal purposes. The leaking flow line has been fixed and there is now legible and correct identification information posted at the well head and the tank battery. The well is now producing and was pumped very recently. No violations were observed. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1501294323 | | 1501294323 | ||
| 2013-12-13 | | 2013-12-13 | ||
− | | | + | | |
| Received phone call from Mr. Carl West of Northwood Energy at 9:46 am. He stated that he and his workers went out to the site and planned where to put flow line and replace the gate to the lease. He also had his electrician out to fit the pumping unit with a new electric motor. He plans to put counterweights on the pumping unit as well. | | Received phone call from Mr. Carl West of Northwood Energy at 9:46 am. He stated that he and his workers went out to the site and planned where to put flow line and replace the gate to the lease. He also had his electrician out to fit the pumping unit with a new electric motor. He plans to put counterweights on the pumping unit as well. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1526475426 | | 1526475426 | ||
| 2014-06-10 | | 2014-06-10 | ||
− | | | + | | |
− | | Upon inspection, it was observed that this well is producing gas on the 1.5 | + | | Upon inspection, it was observed that this well is producing gas on the 1.5 production tubing. The pumping unit for this well currently has no counterweight and there is no motor. I spoke with Mr. Carl West about this well via telephone, and he stated that the pumping unit will have weights and a motor by the end of the month. He also stated that legible and correct I.D. will be placed at the tank and at the well head by the end of the month. I will check back in a couple of weeks to ensure that these activities have been done. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1838795380 | ||
+ | | 2004-12-06 | ||
+ | | | ||
+ | | Inspection this day found no change in status. 2 rolls of poly pipe laying at wellhead - well no longer leaking but still idle. S & S reports can't get in ESI's line so will have to lay new line and tie-in - are working on it but idea when done. Will go ahead and forward for C.O.'s. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -185298711 | ||
+ | | 2005-05-09 | ||
+ | | | ||
+ | | Well now in production - NOV resolved | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1884621416 | | 1884621416 | ||
| 2003-08-15 | | 2003-08-15 | ||
− | | | + | | |
| Inspection this day found well still leaking at meter run, contacted operator and he said coming out 8/14/2003 to look at it - he called 8/15/2003 and said it had been leaking at meter run - flapper was open - and had corrected the problem - still trying to get work-over unit to fix it correctly - also states in the process of selling all his wells, including this one. Will give NOV. | | Inspection this day found well still leaking at meter run, contacted operator and he said coming out 8/14/2003 to look at it - he called 8/15/2003 and said it had been leaking at meter run - flapper was open - and had corrected the problem - still trying to get work-over unit to fix it correctly - also states in the process of selling all his wells, including this one. Will give NOV. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 2043130286 | | 2043130286 | ||
| 2013-12-05 | | 2013-12-05 | ||
− | | | + | | |
| Well has a pumping unit on it with no motor or counterweights. Polish rod is dry and oxidized. There is one 210 barrel tank, a separator and a meter run in the tank battery. There is no chart on the gas meter. No pollution or contamination observed. Production records show that the well has not produced anything in the past 4 years. Spoke with Mr. Carl West about this well and he stated that he will be working on getting a motor and counterweights within the next two weeks. | | Well has a pumping unit on it with no motor or counterweights. Polish rod is dry and oxidized. There is one 210 barrel tank, a separator and a meter run in the tank battery. There is no chart on the gas meter. No pollution or contamination observed. Production records show that the well has not produced anything in the past 4 years. Spoke with Mr. Carl West about this well and he stated that he will be working on getting a motor and counterweights within the next two weeks. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 43928586 | | 43928586 | ||
| 2014-03-27 | | 2014-03-27 | ||
− | | | + | | |
| Spoke with Mr. Carl West via telephone. He stated that he has a contractor scheduled for next week to outfit the pumping unit with weights and a motor. He also explained his setbacks with working on the well. | | Spoke with Mr. Carl West via telephone. He stated that he has a contractor scheduled for next week to outfit the pumping unit with weights and a motor. He also explained his setbacks with working on the well. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 947457566 | | 947457566 | ||
| 2014-03-27 | | 2014-03-27 | ||
− | | | + | | |
| Status of well has not changed. There is still no motor or counter weights on the pumping unit. There was a chart in the sale meter, but it was not current. It was a 7 day chart that was put in there on 12/12/13. I called Carl West and left a voicemail asking him to call me in regards to this well. | | Status of well has not changed. There is still no motor or counter weights on the pumping unit. There was a chart in the sale meter, but it was not current. It was a 7 day chart that was put in there on 12/12/13. I called Carl West and left a voicemail asking him to call me in regards to this well. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| PL1631 | | PL1631 | ||
− | | | + | | |
− | | | + | | |
| Preliminary Restoration done information from Data Point | | Preliminary Restoration done information from Data Point | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Ohio Department of Natural Resources RBDMS | ||
+ | | publisher = [http://oilandgas.ohiodnr.gov/] | ||
+ | | date = 2015-06-19 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection | ||
+ | | accessdate = 2015-06-20 }}</ref> | ||
+ | == References == | ||
+ | {{reflist}} | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Wells]] | [[Category:Wells]] |
Well ID: 34-167-27924 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.54976646,"lon":-81.50614406,"icon":""}]} |
County: Washington | |
Municipality: | |
Operator Name: [[BENATTY CORP
]] | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1985-01-24 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Producing | |
Violations: 0 | |
Latitude: 39.54976646 | |
Longitude: -81.50614406 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
1986-0 | 30418.0 | 0.0 | ||||
1987-0 | 17917.0 | 0.0 | ||||
1988-0 | 10059.0 | 0.0 | ||||
1989-0 | 6780.0 | 0.0 | ||||
1990-0 | 4771.0 | 0.0 | ||||
1991-0 | 3026.0 | 0.0 | ||||
1992-0 | 2537.0 | 0.0 | ||||
1993-0 | 2080.0 | 0.0 | ||||
1994-0 | 1745.0 | 0.0 | ||||
1995-0 | 2297.0 | 0.0 | ||||
1996-0 | 81.0 | 0.0 | ||||
1998-0 | 198.0 | 0.0 | ||||
2003-0 | 0.0 | 0.0 | ||||
2004-0 | 0.0 | 0.0 | ||||
2005-0 | 145.0 | 0.0 | ||||
2006-0 | 658.0 | 0.0 | ||||
2007-0 | 440.0 | 0.0 | ||||
2008-0 | 961.0 | 0.0 | ||||
2009-0 | 211.0 | 0.0 | ||||
2010-0 | 0.0 | 0.0 | ||||
2011-0 | 0.0 | 0.0 | ||||
2012-0 | 0.0 | 0.0 | ||||
2013-0 | 16.0 | 0.0 | ||||
2014-0 | 435.0 | 365.0 | 0.0 | 365.0 |
For data sources see[1]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
-1041193210 | 2010-10-04 | Inspection this day found well with jack, valves shut. ID's at tank, no chart in meter. | Compliance Notice | |||
-1041193210 | 2010-10-04 | Inspection this day found well with jack, valves shut. ID's at tank, no chart in meter. | Compliance Notice | |||
-1041193210 | 2010-10-04 | Inspection this day found well with jack, valves shut. ID's at tank, no chart in meter. | Compliance Notice | |||
1090647921 | 2006-03-16 | Well still was producing - had an NOV against it and not certain of it's status. | ||||
1193106680 | 2014-11-18 | Upon inspection, it was observed that this well is now equipped for production and is producing. A new counterweight stack and electric motor have been fitted on the pumping unit and there is newly ran electrical service to the motor. The valve on the 2 production tubing is in the open position and is running to a mechanical separator and into a 210 bbl production tank. There is a significant gas leak on a 1.25 plastic flow line near the mechanical separator. I spoke with Mr. Carl West over the phone and told him about the leak. I also told Mr. West that I would write the compliance notice off for this well if he fixes the leak and posts ID's at the production tank and the well head. Mr. West stated he would have the leak fixed and new ID's up by the end of the week. | ||||
-1202961335 | 2003-08-14 | Inspection this day found well in violation, not producing, gas venting from well due to equipment failure, landowner complaint 12/6/2004 - no change - well still not producing - 2 rolls of poly line pipe laying by the well - guys have said they are having trouble getting into a line - EOG has line but won't let them in | ||||
-1317710532 | 2011-10-24 | FOLLOW UP TO NOV # 1319537965 Inspection this day found well is idle. It was in a similar state when I last visited site. This well is equipped with a pumping unit. There is no meter in the separator/meter run and no production has been reported since 2009. No identification is posted at either the well or the tank battery. I met with landowner, who was questioning the wells status. Owner must produce, plug or place this well in Temporary Inactive status and post the proper identification. | ||||
1319537965 | 2011-10-24 | Inspection this day found well is idle. It was in a similar state when I last visited site. This well is equipped with a pumping unit. There is no meter in the separator/meter run and no production has been reported since 2009. No identification is posted at either the well or the tank battery. I met with landowner, who was questioning the wells status. Owner must produce, plug or place this well in Temporary Inactive status and post the proper identification. | ||||
-1372012502 | 2003-07-25 | Inspection this day found well not producing, not hooked into sales line, leaking gas from 4 1/2 casing at collar? Called operator - told him of problem and told him to fix immediately - said he would. Landowner felt he was in no immediate danger but had been occuring for some time and only getting worse. | ||||
1407360428 | 2014-08-06 | Upon inspection, it was observed that no changes have been made to this well location since the last inspection on 6/10/2014. The pumping unit still has no counterweights and there is no power run to the electric motor. The valve on the production tubing is in the closed position, and the valve on the annulus of the tubing is open and supplying domestic gas. I will contact Mr. Carl West and inquire about plans for working on this well. | ||||
1428128611 | 2003-08-07 | Inspection this day found well not fixed - had a strap put around the collar at leak but still leaking just as bad or worse. Talked with landowner and told him to keep me informed of status or any worsening. Called Operator and told him it MUST be fixed correctly immediately. Operator came out on 8/8/2003 and tied well into line, but still found it leaking at meter run - Triad knows nothing about it going into their line. | ||||
-1448522022 | 2014-12-03 | Upon inspection, it was obserevd that this well is not being used for annular disposal purposes. The leaking flow line has been fixed and there is now legible and correct identification information posted at the well head and the tank battery. The well is now producing and was pumped very recently. No violations were observed. | ||||
1501294323 | 2013-12-13 | Received phone call from Mr. Carl West of Northwood Energy at 9:46 am. He stated that he and his workers went out to the site and planned where to put flow line and replace the gate to the lease. He also had his electrician out to fit the pumping unit with a new electric motor. He plans to put counterweights on the pumping unit as well. | ||||
1526475426 | 2014-06-10 | Upon inspection, it was observed that this well is producing gas on the 1.5 production tubing. The pumping unit for this well currently has no counterweight and there is no motor. I spoke with Mr. Carl West about this well via telephone, and he stated that the pumping unit will have weights and a motor by the end of the month. He also stated that legible and correct I.D. will be placed at the tank and at the well head by the end of the month. I will check back in a couple of weeks to ensure that these activities have been done. | ||||
-1838795380 | 2004-12-06 | Inspection this day found no change in status. 2 rolls of poly pipe laying at wellhead - well no longer leaking but still idle. S & S reports can't get in ESI's line so will have to lay new line and tie-in - are working on it but idea when done. Will go ahead and forward for C.O.'s. | ||||
-185298711 | 2005-05-09 | Well now in production - NOV resolved | ||||
1884621416 | 2003-08-15 | Inspection this day found well still leaking at meter run, contacted operator and he said coming out 8/14/2003 to look at it - he called 8/15/2003 and said it had been leaking at meter run - flapper was open - and had corrected the problem - still trying to get work-over unit to fix it correctly - also states in the process of selling all his wells, including this one. Will give NOV. | ||||
2043130286 | 2013-12-05 | Well has a pumping unit on it with no motor or counterweights. Polish rod is dry and oxidized. There is one 210 barrel tank, a separator and a meter run in the tank battery. There is no chart on the gas meter. No pollution or contamination observed. Production records show that the well has not produced anything in the past 4 years. Spoke with Mr. Carl West about this well and he stated that he will be working on getting a motor and counterweights within the next two weeks. | ||||
43928586 | 2014-03-27 | Spoke with Mr. Carl West via telephone. He stated that he has a contractor scheduled for next week to outfit the pumping unit with weights and a motor. He also explained his setbacks with working on the well. | ||||
947457566 | 2014-03-27 | Status of well has not changed. There is still no motor or counter weights on the pumping unit. There was a chart in the sale meter, but it was not current. It was a 7 day chart that was put in there on 12/12/13. I called Carl West and left a voicemail asking him to call me in regards to this well. | ||||
PL1631 | Preliminary Restoration done information from Data Point |
For data sources see[2]